Windows ECUpdate SOP 1.5 Eng
Windows ECUpdate SOP 1.5 Eng
b. Make sure the AC/DC adapter is plugged-in (AC Mode) before updating the EC. If the
adapter is not plugged-in, a warning message will appear and it will automatically quit the
program.
c. The system will prompt a warning message prompting you to close all the other
applications before continuing to run the ECWinFlash. It will also prompt for the
corresponding EC size, 64K or 128K.
d. After pressing the OK button, the ECWinFlash window will appear.
h. After shutdown, please re-plug the AC/DC adapter and reboot to complete the EC update
process.
b. Run the ECFLASH.bat, the system will automatically update the EC program.
c. If the model type and the EC file project name to be updated are different, the system will
prompt a warning message and automatically quit the update program.
d. When the EC update is completed, the system will automatically shut down.
e. After shutdown, please removing AC adapter and plug in AC adapter again and than
waiting for the AC power indicator light up orange
Note1: replug the AC/CD adapter for an interval of 3 seconds or more (the time period
differs depending on the model type).