You are on page 1of 21
NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT tems PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. Project: Geotechnical Investigation work under Jal Jeevan Mission-SWSM Water Supply Project at Kanpur Dehat District in Uttar Pradesh ULRNO €902520000000369F Date of Sampling: 03/04/2022 ‘Type of Sample Soil Sample Date of Report issue: 12/04/2022 District KANPUR DEHAT Date of Lab Test Start: 04/04/2022 Block & Village JALIHAPUR (JHINJHAK) Date of Lab Test Complete: 12/04/2022 Location Mark : Latitude : 26.553453 Longitude : 79.801318 Client State Water And Sanitation Mission (SWSM)/UPJN Submitted to M/s GVPR ENGINEERS LIMITED Village Name "AMAULI THAKURAN- TANK CAPACITY 250 KL Registered Office:- K-2/2239, Shastri Nagar, Meerut (UP) 250004 ‘Address:- F-21, Shukh Shant Complex, Mangal Pandey Nagar, Behind Sale Tax Office, Tejgarhi, Meerut (UP) 250001 Contact:- 0121-3550219, 7017231183 | email: pranvi.ac@amail.com PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT ACKNOWLEDGEMENT WE ARE GRATEFUL TO M/S. GVPR ENGINEERS LIMITED FOR PROVIDING US THE OPPORTUNITY TO CARRAY OUT THESE SOIL INVESTIGATION FOR DETERMINATION OF SAFE BEARING PRESSURE ON PROPOSED CONSTRUCTION OF OVERHEAD TANK (OHT) AT SITE: VILL. — JALIHAPUR, BLOCK- JHINJHAK, DISTT.- KANPUR DEHAT IN UTTAR PRADESH. PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT INDEX 1.Introduction: 1 2.Objective..... 1 3.Scope of Work 1-2 4,Ground Water...... 5 Regional Geology..... 6.Topography of Area, 7.Seismic Zone....... 8 Site Stratigraphy... 9.Bearing Capacity Calculation....... 10.Safe Bearing Capacity Recommendations. 9 11.Lab Data Sheet 10-13 12.List of IS Codes and Notation. 14 13.Field Borelog Sheet...... 15-16 14.NABL Certificate. 7 15.Site Photogtaphs...-.reeeeeere PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. (P) NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT ems 1- INTRODUCTION Mis. GVPR Engineers Limited has proposal for the construction of Over Head Tank (OHT) under “State Water and Sanitation Mission District Kanpur Dehat in Uttar Pradesh at site JALIHAPUR, Block- Jhinjhak, District- KANPUR DEHAT in Uttar Pradesh region. For the purpose of construction it is required to have the soil investigation data to identify the geology of the soil and to identify the type of proposed foundation based on the reports. The work of geotechnical investigation for the above said project was entrusted to M/s. Pranvi Infra Projects and Quality Control Pvt. Ltd, Meerut, Uttar Pradesh. ‘The report presented herein deals with the analysis of field and laboratory test results, type and depth of foundation and recommendations based on the type of soil and its safe bearing capacity of soil. 2. OBJECTIVES OF INVESTIGATION ‘The purpose and objectives of investigation was to obtain the sub surface conditions at the site so as to evaluate the soil parameter which are required for evaluating the safe bearing capacity of soil for the design and suitability of the foundation for the proposed structure. The knowledge of general geotechnical subsoil characteristics, compressibility and information about ground water table is an essential requirement for the geotechnical engineer, which would assist the designer to design the foundation system. 3+ SCOPE OF WORK The detailed scope of work of geotechnical investigation for the project was limited to the following: Mobilization of equipment and personnel to the project site, setting up the equipment and carrying out the field investigation and demobilization of the same after completion of fieldwork. * Drilling of One bore hole (BH-1) 150mm diameter of boring at specified locatic mentioned. As per the work order it was requested to go with the manual boring up to a depth of 10.0M bore or N >100 achieved, whichever occurs earlier. * Conducting standard penetration test at regular depth intervals of 1.50m or at every change of strata whichever illustrates earlier and collect samples for further testing. Page Tot 18 PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT roms * Collection of the undisturbed soil samples at every change of the strata. ‘+ Recording the depth of ground water table (If observed). ‘+ Conducting all necessary and relevant laboratory tests on representative soil sample limited to following Natural moisture content Grain Size analysis (Sieve) Liquid and Plastic limits Specific gravity Bulk and Dry density Laboratory testing for evaluating SBC as per latest IS codes. Submission of soil testing report Which includes interpretation of test results and suggesting recommendations for net safe bearing capacity of soll 4- GROUND WATER Based on our measurement in the completed bore hole, water table is not encountered at at the time of our exploration in the borehole. Fluctuation may takes place due to surface evaporation rates and variation in seasonal rainfall, so that water table at 10.00 meter below NGL has been adopted for calculations only. Bore Hole No- 1 NOT MET 5- REGIONAL GEOLOGY ‘The Kanpur Nagar district lies in middle of Uttar Pradesh State. It lies between 25°55" and 27° North latitude and 79°30’ and 80°35" East longitudes in Survey of India Toposheet No. 54N and 63B. The total geographical area of the district is 3155 sq.km. with three number of Tehsil and the numbers of blocks viz. Kalyanpur, Bidhnu, Sarsaul, Bilahaur, Kakawan, Sivrajpur, Chaubepur, Patara, Bhitrgaon and Ghatampur. The major arts of the area is almost a flat plain with some minor undulations. The river Ganga and Yamuna with their tributaries form the drainage system (Dendritic type). Page 20018 © PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT 6- SEISMIC ZONE District Kanpur Dehat falls under moderate damage risk zone-IIl. UTFAR PRADESH EARTHQUAKE ONES - 7- SITE STRATIGRAPHY: Based on our investigation in field and laboratory, it is revealed that the soil al site is: BH-1 : Consists of both cohesive as well as non-cohesive soil throughout the borehole ‘explored. The cohesive type soil found is comprising of Silty Clay soil of low Compressibility and plasticity belonging to ‘CL’ type soil group of IS classification. However Non-cohesive type soil found is consisting of silty sand type soil belonging to SM’ type soil group of IS classification. Page ot 18 PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT Disturbed samples were collected from the split spoon after conducting SPT. The samples are preserved in transparent polythene bags. UDS were collected by driving 75 mm diameter thin walled tubes using a 63.5 kg hammer in accordance with IS : 2132. The tubes are sealed with wax at both ends to minimize loss of moisture. All samples Were transported to our laboratory for further examination and testing 8- BEARING CAPACITY CALCULATIONS. The Safe Bearing Capacity of the foundation of a building / structure without any distress or failure can be determined from the consideration of the following two criteria. (a) Shear Failure Criteria The soil beneath the foundation shall be safe from risk of shear failure. () Settlement Failure Criteria The foundation shall not settle or deflect to an extent causing damage to the structure or impair its usefulness. The Bearing Capacity calculations for a foundation on shallow footing shall be governed by LS, 1904:1986, 1.8, 6403:1981 and I.S. 8009:1976 on the basis of available information regarding the proposed design and have been done in the following sxantinont [ot foae ferent et oye ponte a BOREHOLE Ot nel ed cakahice |e lary ua [SS JAS |S S| ALE [tle segcpetets foe yoru wt Ye at | a Page 40018 EB PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. fe \) i ey ) (P) NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 ROY ‘SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) 7 \\. ‘STRUCTURAL CONSULTANT ress SETTLEMENT CALCULATION AS PERS 6009 (PART 1) 1976 Teh fe Tea 7 BOREHOLE 1 SETTLEMENT CALCULATION AS PERS 8009 (PART 3) 976 Th oe BOREHOLE 1 IZATION AS PERI 6009 [PART 1): 1976 ‘wh fe [anne eee [oa BOREHOLE 2 1 [| [ow [em | 30 | a0 | on Depth of foundton Page Sot 18 NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 e SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) < ‘STRUCTURAL CONSULTANT ems PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. (a ‘BEARING CAPACITY CALCULATIONS AS PER IS: 6403-1961 soreHoLe 1 be “ wn inp Prot Shening Retr Promters No = Ee E = Page 6 ot 18 NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 ROW, ‘SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) 7 \\. ‘STRUCTURAL CONSULTANT ems @ PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. e) SETTLEMENT CALCULATION AS PERTS 8009 (PART) 1576 Tee [ose 0 fb oa BOREHOLE 1 SETTLEMENT CALCULATION AS PER IS 6009 [PART 1): 1976) a rao lose 7 BOREHOLE 1 1 [aw | oo | 100 | 100 | aa ‘a8 Depth tfourdaon ‘SETTLEMENT CALCULATION AS PER IS BO09 [PART 1): 1976 Tete [tose Tao [re ee 7 BOREHOLE 1 1 [cw | 00 | aso | as | aan aa Depth ffoundston Page Tat 18 EB PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. fe \) i ey ) (P) NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 ROY ‘SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) 7 \\. ‘STRUCTURAL CONSULTANT ress SETTLEMENT CALCULATION AS PERS 6009 (PART 1) 1976 twat [8 re Twn a a rca | afd Tier [oa BOREHOLE 1 SETTLEMENT CALCULATION AS PERS 6009 (PART 1) 1976 tee [tae free ne recor —[ BOREHOLE 1 soo fm fm | [ome vom [wes | om wom [tem | om SETTLEMENT CALCULATION AS PERS 8009 (PART 1):1976 Te [a 7a oa BOREHOLE 1 Page Bot 18 PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT Recommendations eorehole | typeot | goer Tsung __Sesatpontn TNS sertement no. | strucure | Foundation tenets | wien | Sethe | reduced (m) im) im) Tonne/sqm (mm) 0 to pao 7 7154 1.00 2.00 200 7.30 314 motu oa BH Pumptiowe 450 | oyeeance | 200 | 100 2 | "andstat | st a aH Gueres | 150 wae [300 | 200 ; 200 io) a0 |) Ba 200 20 | 20] 7B Borehote | Typeat | ,22Pthot | shapeat | SueotFooting | NetSHfe | sruemen No. | suucure | Foundation | poouing | Outer | toner | Bearing | “produced (m) (m) (m)__| Tonne/sam | _(mm) ANNAULAR 10.76 69.67 2.00 WAUAR | 900 | 300 ANNAULAR 11.61 69.35 1 | om | 250 NAUAR | oo | 300 ANNAULAR 11.39 63.63 3.00 wurak T soo | 300 DECLARATIO! 1.The recommendation are based on the field investigation data results and the laboratory tests results of the samples collected from the test locations at particular point and our experience in this regards. 2.The sub-soil condition may differ at other point. 3.lf the actual sub-soil conditions during excavation for the foundations differ from that has been reported, a reference should be made to us for suggestions. 4 Further, the recommendations are based on the assumptions as mentioned in the report and the designer of the structure should take into consideration all the factors required as per codes. 5.The recommendations should be taken as guidelines for the designer. For Pranvi Infra Projects and Quality Control Pvt. Ltd. Authorized Signatory Ravish Kumar CS Sy Page Sot 18 PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT 3 )3) a 1 WATER SUPPLY PROJECT A JALIAPUR OISTT-RONPUR DEAT CONTROL PvT. LTD. Materia P855i°8 aeweargume] F 7, tleye Sew | 1B sive i 2] F | E| s [cnmacensies| § Depth of Bore els i s/2@/s]ar, a Hol gla|sie fle i g\3le}3| i aE SEE] Ss] Sfufmjal es i a) a)e)3|3 : Eis i8|e | 2 5 gals 3 & ae my ory w ca ls] ray | earasal cw] 16a) 1 zpeps pe]? fete pe, pe 14 ep pepe] bat 2 Tas os ear we ee ee Toa er ee THT [awa] Toe [2a ORSO| Oa | eT 150-195 [SP whee 7a aes | os [ool oe es fe ee Ta [ao] 1a [sofa Os | 300+ 345 | SPT =a [ae TE ase OS rea eo we ae ee Ta ea TE E50 495 | SPT ae ae Sas Spo] os [oo wo] we [oF [ORT | SH Te ema 1s [asso] oar S00 6.45 | SPT eee a THE TSO] OS eo [OO] aT | NONFASTE | Teese T= Tat 795 | Ser 7 ame | a8 Tas ao] os [on [oo] we |e [ROAST | SH Ta ema] se = Tod = a.a5 [SPT [ee | Tas Ta one os Der eo as ae STE Se Page Tot 18 PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT tems DEPTH OF BOREHOLE 10.00 IVILLAGE NAME JAUHAPUR WATER TABLE NOT MET BH NO- 1 VARIATION OF N VALUE FIELD AND CORRECTED WITH DEPTH ©-Seriest © Series2 10 9 2»® e 18 2n® 7 w 6 & o . u u@ 4 9 3 2@0@ 2 v Bo C 1 ° ° 5 10 15 20 2s NVALUE Page Tt of 18 PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT Min Pra stress Set Bea Seea Stet 2100 Rasa: sens StresySqem) Stem. See 3 dovongsqem seme tear Srey Sqm) J cout i i gear aaey fag itm RESTS S| i L141 4 a Norma Stes gSqem) Page Zale © PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT ra a inka Vid Ratio =06500, 0.60 A dex C=0.06195 00 Bere Hole No:BLL 0.30 Lt I pPrecsureKpSqem) Page ore PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT tems LIST OF REFERRED IS CODES FOR FIELD WORK IS: 1892-1974 Code of practice for subsurface investigations for foundations. IS: 2132-1986 Code of practice for thin walled tube sampling of soils. IS: 2131-1981 Method of standard penetration tests for soils. FOR ALL LABORATORY TEST IS: 2720-1983(Partl) Methods of tests for soils: Preparation of dry soil samples for various tests (second revision ). IS + 2720-1980 (Part-2) Methods of test for soils: Determination of water content (second revision) Amendment 1 IS: 2720-1980(Part-3/Secl) Method of test for soil : Determination of specific gravity Fine grained soils IS: 1980(Part-3/Sec2) Method of test for soil : Determination of specific gravity : Fine mediumé& coarse grained soils.(First revision) IS: 2720-1985 (Part-4) Methods of test for soils: Grain size analysis (Second revision). IS: 2720-1985 (Part-6) Methods of test for soils: Determination of liquid and plastic limit (Second revision). IS :1498-1970 Classification and identification of soils for general engineering purposes( first revision)Amendment2 FOR BEARING CAPACITY ANLYSIS, 5. IS: 6403-1981 Code of practice for determination of bearing capacity of shallow foundations. 6. 1S: 8009(Part 1)-1976 Code of practice for calculation of settlements of foundations. 7. IS: 1904-1986- Code of practice for design and construction of foundation in soils: General requirements (Third revision), Page 14 of 8 PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT (Nl ata Page Sole PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT Page 1601S PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT Mies Pine ale | Page 17 ore PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT National Accreditation Board for Testing and Calibration Laboratories Nal CERTIFICATE OF ACCREDITATION PRANVI INFRA PROJECTS AND QUALITY CONTROL PVT. LTD. thas heen assessed and accredited in accordance with the standard ISO/IEC 17025:2017 "General Requirements for the Competence of Testing & Calibration Laboratories" for its facilities at 2 SUKH SHANT COMPLEX, MEFRUT, UTTAR PRADESH, INDIA, in the field of TESTING CCetifeae Nuambcr: TC-9025 Tose Date: orm ‘aia Wnt stone ‘This cetifcate remains valid (or the Scope of Accreditation as specified i the annexure subject to continued satisfactory compliance tothe above standard & the reevaut requirements of NABL. Signed for and on behalf of NABL, Rateteim— N. Venkateswara (Chet Executive Officer Page Tot 8

You might also like