You are on page 1of 20
NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT roms PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. Project: Geotechnical Investigation work under Jal Jeevan Mission-SWSM Water Supply Project at Kanpur Dehat District in Uttar Pradesh ULRNO 7€902520000000389F Date of Sampling: 07/04/2022 ‘Type of Sample Soil Sample Date of Report issue: 16/04/2022 District KANPUR DEHAT Date of Lab Test Start: 09/04/2022 Block & Village NUNARI BAHADURPUR Date of Lab Test Complete: 16/04/2022 (MAITHA) Location Mark : Latitude : 26.627752 Longitude : 79.953352 Client State Water And Sanitation Mission (SWSM)/UPJN Submitted to M/s GVPR ENGINEERS LIMITED Village Name NUNARI BAHADURPUR Registered Office:- K-2/2239, Shastri Nagar, Meerut (UP) 250004 Address:- F-21, Shukh Shant Complex, Mangal Pandey Nagar, Bohind Sale Tax Offi 250001 Contact:- 0121-3550219, 7017231183 | em: fejgarhi, Meerut (UP) pranvi,ge@amail,com PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT ACKNOWLEDGEMENT WE ARE GRATEFUL TO M/S. GVPR ENGINEERS LIMITED FOR PROVIDING US THE OPPORTUNITY TO CARRAY OUT THESE SOIL INVESTIGATION FOR DETERMINATION OF SAFE BEARING PRESSURE ON PROPOSED CONSTRUCTION OF OVERHEAD TANK (OHT) AT SITE: VILL. -NUNARI BAHADURPUR, BLOCK- MAITHA, DISTT.- KANPUR DEHAT IN UTTAR PRADESH. PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT INDEX 1.Introduction: 1 2.Objective..... 1 3.Scope of Work 1-2 4,Ground Water...... 5.Regional Geology..... 6.Topography of Area, 7.Seismic Zone....... 8 Site Stratigraphy... 9.Bearing Capacity Calculation....... 10.Safe Bearing Capacity Recommendations. 9 11.Lab Data Sheet 10-13 12.List of IS Codes and Notation. 14 13.Field Borelog Shect....... 14.NABL Certificate. 16 16.Site Photogtaphs........ 2 ATAD PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. (P) NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT ems 1- INTRODUCTION Mis. GVPR Engineers Limited has proposal for the construction of Over Head Tank (OHT) under “State Water and Sanitation Mission District Kanpur Dehat in Uttar Pradesh at site NUNARI BAHADURPUR, Block- MAITHA, District- KANPUR DEHAT in Uttar Pradesh region. For the purpose of construction it is required to have the soil investigation data to identify the geology of the soil and to identify the type of proposed foundation based on the reports. The work of geotechnical investigation for the above said project was entrusted to M/s. Pranvi Infra Projects and Quality Control Pvt. Ltd, Meerut, Uttar Pradesh. The report presented herein deals with the analysis of field and laboratory test results, type and depth of foundation and recommendations based on the type of soil and its safe bearing capacity of soil. 2. OBJECTIVES OF INVESTIGATION ‘The purpose and objectives of investigation was to obtain the sub surface conditions at the site so as to evaluate the soil parameter which are required for evaluating the safe bearing capacity of soil for the design and suitability of the foundation for the proposed structure. The knowledge of general geotechnical subsoil characteristics, compressibility and information about ground water table is an essential requirement for the geotechnical engineer, which would assist the designer to design the foundation system. 3+ SCOPE OF WORK The detailed scope of work of geotechnical investigation for the project was limited to the following: Mobilization of equipment and personnel to the project site, setting up the equipment and carrying out the field investigation and demobilization of the same after completion of fieldwork. * Drilling of One bore hole (BH-1) 150mm diameter of boring at specified locatic mentioned. As per the work order it was requested to go with the manual boring up to.a depth of 10.0M bore or N >100 achieved, whichever occurs earlier. * Conducting standard penetration test at regular depth intervals of 1.50m or at every change of strata whichever illustrates earlier and collect samples for further testing. PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT roms * Collection of the undisturbed soil samples at every change of the strata. + Recording the depth of ground water table (If observed). ‘+ Conducting all necessary and relevant laboratory tests on representative soil sample limited to following Natural moisture content Grain Size analysis (Sieve) Liquid and Plastic limits Specific gravity Bulk and Dry density Laboratory testing for evaluating SBC as per latest IS codes. Submission of soil testing report which includes interpretation of test results and suggesting recommendations for net safe bearing capacity of soll 4. GROUND WATER Based on our measurement in the completed bore hole, water table is encountered at 3.00 meter during the time of our exploration in the borehole. Fluctuation may takes place due to surface evaporation rates and variation in seasonal rainfall, so that water table at 1.00 meter below NGL has been adopted for calculations only. Bore Hole No- 1 3.00 meter below NGL 5- REGIONAL GEOLOGY ‘The Kanpur Nagar district lies in middle of Uttar Pradesh State. It lies between 25°55" and 27° North latitude and 79°30’ and 80°35" East longitudes in Survey of India Toposheet No. 54N and 63B. The total geographical area of the district is 3155 sq.km. with three number of Tehsil and the numbers of blocks viz. Kalyanpur, Bidhnu, Sarsaul, Bilahaur, Kakawan, Sivrajpur, Chaubepur, Patara, Bhitrgaon and Ghatampur. The major Parts of the area is almost a flat plain with some minor undulations. The river Ganga and Yamuna with their tributaries form the drainage system (Dendritic type). PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT 6- SEISMIC ZONE District Kanpur Dehat falls under moderate damage risk zone-IIl. UTFAR PRADESH EARTHQUAKE ONES - 7+ SITE STRATIGRAPHY: Based on our investigation in field and laboratory, it is revealed that the soil at site is: BH-1 : Consists of both cohesive as well as non-cohesive soil throughout the borehole ‘explored. The cohesive type soil found is comprising of Silty Clay soil of low Compressibility and plasticity belonging to ‘CL’ type soil group of IS classification. However Non-cohesive type soil found is consisting of silty sand type soil belonging to SM’ type soil group of IS classification. PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT Disturbed samples were collected from the split spoon after conducting SPT. The samples are preserved in transparent polythene bags. UDS were collected by driving 75 mm diameter thin walled tubes using a 63.5 kg hammer in accordance with IS : 2132. The tubes are sealed with wax at both ends to minimize loss of moisture. All samples were transported to our laboratory for further examination and testing 8- BEARING CAPACITY CALCULATIONS. The Safe Bearing Capacity of the foundation of a building / structure without any distress or failure can be determined from the consideration of the following two criteria. (a) Shear Failure Criteria The soil beneath the foundation shall be safe from risk of shear failure. () Settlement Failure Criteria The foundation shall not settle or deflect to an extent causing damage to the structure or impair its usefulness. ‘The Bearing Capacity calculations for a foundation on shallow footing shall be governed by LS, 1904:1986, 1.8. 6403:1981 and I.S. 8009:1976 on the basis of available information regarding the proposed design and have been done in the following paragraphs. BEARING CAPACITY CALCULATION HET AS ER 5 8-1981 tito |4000 | ree frermaviesetce wot) aap cts ue BOREHOLE OY Powis Jy fravtnaieneriwin | 20 qi prot] vo fic sr eS Pon] en |i cs teen fa tee Tenet | Cod eae a fnew fm ore [et be EB PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. fe \) i a ) (P) NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 ROY SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) 7 \\. ‘STRUCTURAL CONSULTANT ress SETTLEMENT CALCULATION AS PERS 8009 (PART 1) 1576 ow Tara [vie esr [a BOREHOLE 1 SETTLEMENT CALCULATION AS PERS 8009 (PART 1) 1576 = ft ow BOREHOLE 1 ‘SETTLEMENT CALCULATION AS PERS 8009 (PART): 1976 = te yer [a BOREHOLE 1 NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 we SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT ems @ PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. a) ‘BEARING CAPACITY CALCULATIONS AS PER IS: 6403-1981 Tepttona | 1020 Jute fraesee ns a pe, a ‘BOREHOLE Ot tra une or fsures sort morsonrse ne =| fe a Tiana apa arate Steiger a | a fo hae Jn) |e | encnenratn arena] comncen | an [Bort] nae oh TEE NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 ROW, SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) 7 \\. ‘STRUCTURAL CONSULTANT ems @ PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. ) SETTLEMENT CALCULATION AS PERS 6008 [PARTS] 1576 Torr [6 fo 10 fie a BOREHOLE 1 so [mf mm [me ‘ae | owt | ton otf em | eer > | aa | 000 | 100 tat aa Dept ffoundaton ‘SETTLEMENT CALCULATION AS PERS 8005 (PART) 1976 Tere [aa fee a0 fe a BOREHOLE 1 1 [ew] om fio lamfan]- | - 288 Depth ffoundaton ‘SETTLEMENT CALCULATION AS PERS 8009 (PART) :1976 Taras [8 foes fi oa BOREHOLE 1 + | aa | ooo | iso | sso | tan 1086 Depth tfoundaton @ PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. ) NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 ROY SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) 7 \\. ‘STRUCTURAL CONSULTANT ress SETTLEMENT CALCULATION AS PERS 005 [PARTI]: 176 Ta [ase enn eprennion [tain = oa BOREHOLE 1 2 [aw | oo | 250 | as0 | 1 1086 Depth of foundton ‘SETTLEMENT CALCULATION AS PERS 8009 (PART I): 1976 = we oa BOREHOLE 1 we fm pm | m [owe wai [ee | en 2 [cw | oe | 200 | 200 | 10: as, Depth foundation ‘SETTLEMENT CALCULATION AS PERS 8005 [PART]: 176 Tee [aa fn oa BOREHOLE 1 2 [aw | om | 200 | 2m | 18: ne Depth of foundton PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT RECOMMENDATIONS Depth of wzeotFooting | NSS" | catsumeme | Safe Borehole | Typeot | Foundation | TypectFooting | S**°F2°tE | gearing | Settlement | aowable . below Tenath [wath] _Capacty Pressure (m) (m) (m) Tonne/sqm (mm) Tonne/sqm_ 100 x00 | ao) 8S) ra |e 00 700) a0 | 7S) SE PUMP 150 1.00 1.00 9.00 26.90 857 iolated nec 1 HOUSE/STAFF ‘QUARTERS 1.50 Square 200 | 200 8.09, 42.98 707 2.00 1.00 | 1.00 9.86 26.08 8.43 200 x00 | 20) 88 ae aa 5 t sae Borehole | Type of Depth of Shape of Size of Footing Net Safe Settlement No. Structure | Foundation Footin, Outer | Inner Bearing Produced | Allowable ‘ below GL e Dia Dia Capacity Pressure (my (m) (m)__| Tonne/sqm (mm) __| Tonne/sam ANNAULAR 9.12 101.29 8.97 2.00 NAUIAR | 909 | 3.00 TARNAUIAR oss) 08 : 1 | om 250 NAUIAR | 909 | 3.00 ANNAULAR 11.47 106.49 10.55 3.00 mae | sco | 3.00 | DECLARATION:: 1.The recommendation are based on the field investigation data results and the laboratory tests results of the samples collected from the test locations at particular point and our experience in this regards. 2.The sub-soil condition may differ at other point. .If the actual sub-soil conditions during excavation for the foundations differ from that has been reported, a reference should be made to us for suggestions. 4.Further, the recommendations are based on the assumptions as mentioned in the report and the designer of the structure should take into consideration all the factors required as per codes. 5.The recommendations should be taken as guidelines for the designer. For Pranvi Infra Projects and Quality Control Pvt. Ltd Authorized Signatory Ravish Kumar (QM) PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT TEST RESULTS Bore Hoe No. [wim No —Yo909520000000968F Depth of Water Level (mbgh] 3.00 1 ane of post GEOTECHNICAL NVESIGATION WORK UNDER IAL JEEVAN MISSIN-SwSHt | PRANV! NFRA PROJECTS & QUALITY WATER SUPPLY PROJECT AT NUNARIGAHADURPUR DISTT: KANPUR DEHAT netwrgunts] felis]? ]é > Shear] : ewtwatinns| E | Hala F | 2 [characteristics] § Depth of Bore |g ele ai] é | 3 elit s |s..| 28 Hole 2/8 /8/ 2) Slujejn| e |e yale Tila 5 Ele|sfsfs : eifz |? é 3 8 = em ry yl [We N Ne foward @ (@) | ee) 1 a | 5 [16 fe] | 0 [ata ECS] SI OD o To = a5 ow [oe [we | we |S [so fe |e Tar | es0) ToT [zer lowes oa | fa 150-195 | SPT 7 [336 [a8 20-285 | 0s [roo [reo] os ww [ooo ras [70] ss [zat fora ose |_| = 300-845 [SPT 5 [aia | et iB = 480 | 0S [Too [Too] o> | 26 RONEASTE | SW Tat rao) Te T= 450-435 | Ser 6 | 272 | TT Sa = emo OS [Too [Too] wear ep] a5 | Taa0] 15 [zat foro ose | S| = 600-645 | Ser 5 [ras | 7a Tis 750] 0S [too [wo we we ewe [a 788 [1690] 156 —[=T= 750-795 | SPT a peat te Bas 800 | OS [roo [roo] we [we Pea eo a6 | Ta0) T= 300-945 | ser ee | ae 3a woo os Pool or Pere eee PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT tems DEPTH OF NUNARI BOREHOLE 10.00 [VILAGE NAME BAHADURPUR WATER TABLE 3.00 BH NO- 1 VARIATION OF N VALUE FIELD AND CORRECTED WITH DEPTH © Seriest ©-Series2 10 18 ° 2 4 6 8 0 2 B20 NVALUE PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 ‘SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT q Typeot ewe Ue . 4 “Major Pricipal stress — Set 1 by pan } ieee} | e-foths ee! 7 fariksasm — GuRgagcn stan 2Songsqem seme Simple Ne ba a eee ops | Hames a SSSR Sina trestkaem) a PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. (P) NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT a Void Ratio “0.668. oso t tcc tt ° | i | ps ae $ oa EERO BBs aoa 3 a ox ox 2 pPressureySy0m) PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT roms LIST OF REFERRED IS CODES FOR FIELD WORK IS: 1892-1974 Code of practice for subsurface investigations for foundations. IS: 2132-1986 Code of practice for thin walled tube sampling of soils. IS: 2131-1981 Method of standard penetration tests for soils. FOR ALL LABORATORY TEST IS: 2720-1983(Partl) Methods of tests for soils: Preparation of dry soil samples for various tests (second revision ). IS + 2720-1980 (Part-2) Methods of test for soils: Determination of water content (second revision) Amendment 1 IS: 2720-1980(Part-3/Secl) Method of test for soil : Determination of specific gravity Fine grained soils IS: 1980(Part-3/Sec2) Method of test for soil : Determination of specific gravity : Fine mediumé& coarse grained soils.(First revision) IS: 2720-1985 (Part-4) Methods of test for soils: Grain size analysis (Second revision). IS: 2720-1985 (Part-6) Methods of test for soils: Determination of liquid and plastic limit (Second revision). IS :1498-1970 Classification and identification of soils for general engineering purposes(first revision)Amendment2 FOR BEARING CAPACITY ANLYSIS, 5. IS: 6403-1981 Code of practice for determination of bearing capacity of shallow foundations. 6. 1S: 8009(Part 1)-1976 Code of practice for calculation of settlements of foundations. 7. IS: 1904-1986- Code of practice for design and construction of foundation in soils: General requirements (Third revision), PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. @ NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) STRUCTURAL CONSULTANT ® PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. SITE PHOTOGRAPHS PRANVI INFRA PROJECTS & QUALITY CONTROL PVT. LTD. NABL Accredited Laboratory ISO/IEC 17025:2017, TC-9025 SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING) ‘STRUCTURAL CONSULTANT National Accreditation Board for Testing and Calibration Laboratories Nal CERTIFICATE OF ACCREDITATION PRANVI INFRA PROJECTS AND QUALITY CONTROL PVT. LTD. thas heen assessed and accredited in accordance with the standard ISO/IEC 17025:2017 "General Requirements for the Competence of Testing & Calibration Laboratories" for its facilities at 2 SUKH SHANT COMPLEX, MEFRUT, UTTAR PRADESH, INDIA, in the field of TESTING CCetifeae Nuambcr: TC-9025 Tose Date: orm ‘aia Wnt stone ‘This cetifcate remains valid (or the Scope of Accreditation as specified i the annexure subject to continued satisfactory compliance tothe above standard & the reevaut requirements of NABL. Signed for and on behalf of NABL, Rateteim— N. Venkateswara (Chet Executive Officer

You might also like