Professional Documents
Culture Documents
Air Cooled Chiller Datasheet
Air Cooled Chiller Datasheet
Description
A GENERAL INFORMATION
1 Item description
2 Make
3 Model
4 Outdoor design condition
5 Summer DBT/WBT °C
6 Monsoon DBT/WBT °C
7 Winter DBT/WBT °C
8 Type of duty operation hrs
9 Installation location
10 Altitude m above MSL
11 Refrigerant Type
12 Refrigerant Charge kg
13 Number of chillers
14 Noise pressure level dB
15 VFD compatible
16 Certification
B CAPACITY OF UNIT
1 Total capacity TR
2 Minimum capacity % Loading Range
3 kW/Ton at full load
4 Capacity control
C COMPRESSOR
1 Manufacturer
2 Model Number
3 Type
4 Number of compressors Nos.
Capacity of compressors (indicate capacity of
5 each) TR/TR/TR
6 Number of stages Nos.
7 Maximum speed RPM
8 Minimum speed RPM
9 Arrangement
10 Suction Pressure Pa
11 Discharge Pressure Pa
12 Suction Temperature Deg. F
13 Discharge Temperature Deg. F
14 Oil type
15 Oil charge ltrs
Compressor suction & discharge isolation
16 valves
17 Compressor casing material
18 Compressor shaft material
19 Compressor suction valve material
20 Type of thrust bearings
21 Type of radial bearings
D COMPRESSOR MOTOR
1 Make
2 Model
3 Type
4 Enclosure type
5 Cooling method
6 Power (indicate capacity of each) kW/kW/kW
7 Speed RPM
8 Volts / Phase / frequency
9 Insulation class
10 Protection
11 Efficiency Class
12 VFD output A
E EVAPORATOR
1 Model
2 Evaporator type
3 Chilled water flow rate- peak USGPM
4 Chilled water flow rate- minimum USGPM
5 Chilled water temperature - Inlet Deg. C
6 Chilled water temperature - Outlet Deg. C
7 Chilled water pressure drop m of WC
8 Refrigerant boiling temperature Deg. F
9 Fouling factor Sq.ft. Deg.F. Hr/BTU
10 Tube passes Nos.
11 Tube Material
12 Diameter of tube mm
13 Number of tubes
14 Tubes length mm
15 Tube thickness at fin root inches
16 Tube surface - internal / external
17 External tube heat transfer surface Sq.ft
F CONDENSER
1 Model
2 Condenser Type
3 Number of fans
4 Total flow rate across condenser CFM
5 Refrigerant condensing temperature Deg. F
6 Air temperature rise across condenser Deg. F
7 Tube passes Nos.
8 Tube Material
9 Tube coating
10 Diameter of tube mm
11 Tube thickness mm
12 Tube surface - internal / external
13 External tube heat transfer surface Sq.ft
14 Fin Material
15 Fin Thickness mm
16 Number of fins per unit length FPI
17 Fin coating
G FAN MOTOR
1 Make
2 Model
3 Type
4 Power (indicate capacity of each) kW/kW/kW
5 Speed RPM
6 Volts / Phase / frequency
7 Insulation class
8 Protection
9 Efficiency Class
H ACCESSORIES
1 Hot gas bypass
2 Chilled water flow switch
3 Vibration isolators
4 Expansion valve
5 Soft starter
6 Oil heater
7 Oil heater quantity
8 Oil heater power supply details Ø/V/Hz
9 BMS connectivity
10 Flow switch
11 Control panel
12 Chiller package insulation
I SENSORS/INTERLOCKS
1 Undervoltage & phase protection
H DIMENSIONAL DETAILS
1 Maximum length mm
2 Maximum width mm
3 Maximum height mm
4 Tube replacement length mm
5 Static weight kg
6 Operating weight kg
I SCOPE OF WORK
J ANALYSIS
1 SP. POWER CONSUMPTION KW/TR
2 100% load
3 75% load
4 50% load
5 25% load
6 Minimum load
NOTE -
1 Vendor to submit GA drawing & to take approval from DSG prior manufacturing.
2 Final chiller dimension, weight & size should be as per final GA drawing.
3 Vendor to dispatch chiller as per agreed dispatch schedule.
OOLED CHILLER DATASHEET
Vendor to specify
Vendor to specify
Vendor to specify
Vendor to specify
Vendor to specify
Vendor to specify
R-134a/R407 Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify
Max 75 dB @ 1m dist. Vendor to specify
Yes/No Vendor to specify
AHRI 550/590 Vendor to confirm
Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Stepless/In Steps Vendor to specify
10 Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Flanged/Victaulic Vendor to specify
Steel Vendor to specify
Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Copper Vendor to specify
Hydrophilic coating/NA
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Enhanced Vendor to specify
Vendor to specify Vendor to specify
Aluminium Vendor to specify
Vendor to specify Vendor to specify
Vendor to specify Vendor to specify
Hydrophilic coating/NA Vendor to specify
G prior manufacturing.
GA drawing.