h d
Per ACI 318-05 Code:
2*dc
Es = 29000 ksi As
Ec = 3738 ksi dc
n= 7.76 n = Es/Ec One-Way Slab
fs = 904.99 ksi
fs(used) = 40.00 ksi (lesser of 'fs' and 2/3*fy)
s(max) = 10.31 in. >= s = 8 in., O.K.
dc = 1.5000 in.
z= 132.08 k/in.
z(allow) = 145.00 k/in. >= z = 132.08 k/in., O.K.