Professional Documents
Culture Documents
PRODUCT
100 gpm
380 L/min
6.25
900 psi
OPTIONAL
DRAIN
3.13 DIRT ALARM
PLUG
D5C
3.13
Ø 4.62
1K=14.95
2K=24.36
3K=33.76
6.25
IN OUT
(STD.) (STD.)
2.81
SERIES W.P. PSI
5.63
ELEMENT
BYPASS VALVE PSI
MAX
OPTIONAL
4.50
DIRT ALARM
OR ELECTRIC
SWITCH
OUT 2.79
IN
5.59
1.31
Metric dimensions in ( ).
Model No. of filter in photograph is K91KZ5BP20NP20ND5C.
Filter Flow Rating: Up to 100 gpm (380 L/min) for 150 SUS (32 cSt) fluids
Housing Max. Operating Pressure: 900 psi (60 bar)
Specifications Min. Yield Pressure: 3200 psi (220 bar)
Rated Fatigue Pressure: Contact factory
Temp. Range: -20°F to 225°F (-29°C to 107°C)
Bypass Setting: Cracking: 40 psi (2.8 bar)
Bypass Setting: Full Flow: 80 psi (5.5 bar)
Porting Base & Cap: Cast Aluminum
Element Case: Steel
Weight of K9-1K: 19 lbs. (8.6 kg)
Weight of K9-2K: 30 lbs. (13.6 kg)
Weight of K9-3K: 41 lbs. (18.6 kg)
Element Change Clearance: 8.50” (215 mm)
Element Absolute Rating Per ISO 4572 / NFPA T3.10.8.8 Abs. Rating wrt ISO 16889
Using automated particle counter (APC) calibrated per ISO 4402 Using APC calibrated per ISO 11171 Dirt Holding
Performance Element ßx ≥ 75 ßx ≥ 100 ßx ≥ 200 ßx(c) ≥ 200 ßx(c) ≥ 1000 Capacity gm
Information K3 6.8 7.5 10.0 N/A N/A 54
K10 15.5 16.2 18.0 N/A N/A 44
KZ1 <1.0 <1.0 <1.0 <4.0 4.2 112
KZ3 <1.0 <1.0 <2.0 4.7 5.8 115
KZ5 2.5 3.0 4.0 6.5 7.5 86
KZ10 7.4 8.2 10.0 10.0 12.7 108
KZ25 18.0 20.0 22.5 19.0 24.0 93
Element Collapse Rating: 150 psid (10 bar)
Flow Direction: Outside In
Element Nominal Dimensions: 4.0” (100 mm) O.D. x 9.0” (230 mm) long
gpm 0 20 40 60 80 100
Flow RT
(L/min) 0 50 150 250 380
Shown above are the elements most commonly used in this housing. requires 2” porting (P32) RTD
∆Pfilter = ∆Phousing + ∆Pelement ∆Phousing ∆Pelement Pressure KFT
Exercise:
K9 ∆Phousing for fluids with sp gr = 0.86: ∆Pelement = flow x element ∆P factor Drop
Determine ∆P at 80 gpm (303 L/min) for x viscosity factor
K93KZ3BP20NP20ND5C using 200 SUS Information LRT
Flow (L/min) El. ∆P factors @ 150 SUS (32 cSt):
(44 cSt) fluid. (50) (150) (250) (350) Based on
10 1K 2K 3K
Flow Rate BFT
Solution: K3 .25 .12 .08
8
K10 .09 .05 .03 and Viscosity
∆Phousing = 6.0 psi [.41 bar] (0.50)
K25 .02 .01 .01
∆P psi
Accessories
∆P (bar)
6
∆Pelement = 80 x .03 x (200÷150) = 3.2 psi KZ1 .20 .10 .05
or KZ3 .10 .05 .03 for Tank-
4
∆Pelement = [303 x (.03÷54.9) x (44÷32) = (0.25) KZ5 .08 .04 .02 Mounted
.23 bar] 2 KZ10 .05 .03 .02 Filters
KZ25 .04 .02 .01
∆Ptotal = 6.0 + 3.2 = 9.2 psi 0 If working in units of bars & L/min,
or 0 20 40 60 80 100 divide above factor by 54.9. PAF1
Flow gpm
∆Pelement = [.41 + .23 = .64 bar] Viscosity factor:
sp gr = specific gravity Divide viscosity by 150 SUS (32 cSt).
MAF1
Sizing of elements should be based on element flow information provided in the Element Selection chart above.
MF2
“In” Porting “Out” Porting Dirt Alarm** Filter TF1
Filter No. of Element Seal Port 1 Port 2 Port 3 Port 4 Port (See Appendix A for
Series Elements Model No. Material (STD) (OPT) (STD) (OPT) Size complete list of options) Model
K3
K10
Number TF3
K25* Selection
KZ1 N N N = None
KZ3 KF3
1 N P16 N P16 P16 = 1” NPTF
KZ5 P20 = 11⁄4” NPTF
KZ10 P20 P20
K9 2 P16 P24 P16 P24 P24 = 11⁄2” NPTF LF1
KZ25 D5 = Cartridge
B = Buna N P20 P20
KM10 P24 S16 P24 S16 S16 = SAE-16 D5C = Cartridge
KM25 S20 S20 S20 = SAE-20 in Cap
3 KM60 H = EPR S16 S24 = SAE-24 LF1—2"
S24 S16 S24
KM150 S20
KM260 F16 S20 F16 F16 = 1” Flange Electric Cartridge:
S24
V = Viton F20 S24 F20 F20 = 11⁄4” Flange SRLT
F24 = 11⁄2” Flange MS5AC/DC/LC Family
KW B16 F24 B16 F24
Porting Options B20
B20 B16 = 1-11 BSPP
B24 B16
B24
B16 TRLT
4 OUT
B20 B20 B20 = 11⁄4-11 BSPP
OUT
B24 B24 B24 = 11⁄2-11 BSPP
IN
1 3 RLT
2 IN