Bloque 61 Facilities & Construction Electrical Basis of Design PETROADAZONAS ‘spesiteation DOE No S1Gris8AGP Ta roa [Pea DOCUMENTOS ANEXOS DOCUMENTOS DE REFERENCIA Speciicaon Number 36585608 Electra Basis of Design - Rov 0 MATIVO ona om aa — ee ee eerie ae Set enn by a ° 9007 Tose oweago Bloque 61 Facilities & Construction w Electrical Basis of Design | PETROAMAZONAS. ‘Specification OE: Ne s1onTAGP TSR Tao Pia? CONTENTS 410 GENERAL 20 ELECTRICAL EQUIPMENT 30 LIGHTING SYSTEM 40. WIRING METHOD 50 WIRES AND CABLES 60. GROUNDING SYSTEM AND CATHODIC PROTECTION 7.0 DRAWINGS 10 ‘Speoifestion a fir Pia. GENERAL, ry 42 13 _ Bloque 61 Facilities & Construction Electrical Basis of Design PETROANZONAS ‘Scope This specication covers the minimum requirements forthe Design of electrical power Aistbution, centro, ighting, communication, and grounding yetems 14a 142 143 For the purposes of this document, Contracior shall be defined as Company's Engines forthe project facies Design, or is appointed authority, For the purposes of this document, Vendor shall be defined ae the [Manufacturer or Supplier of purchased equipment. For the purposes of tis document, Company shall be defined as Occidental Exploration and Production Company andlor i duly authorized agents. Code Regulations, and Standards 424 122 Except where indicated otherwise in this specification, the design and instalation ofthe electrical systom shall comply with th latast requirements of the folowing codes, regulations, and standards NEC The Nationa Electial Code NESC The National Electrical Safety Code INEPA Standard 70, 497M and 496 API American Petroleum institute RP 500, RP 540, STO 541 ‘OSHA Occupational Safety and Health Standard NEMA MG-1 IES" tluminating Engineering Society Local Eectrical Codes Packaged equipment shall comply withthe requirements ofthe specication for ‘lectrical and instrumentation tems on packaged equipment, Clasificaton ol Azeas 434 492 133 134 ‘The limts of hazardous and non-hazardous areas shal be selected in general ‘accordance with the appropriate sections of API Standard RP-600 and shall bs ‘pectcaly defined on a drawing, In defining the type of instalation for a given acatdous ane, elec sh bbe made fo Article 500 through 803 ofthe National Eleccal Code (NFPA 70) ‘and NFPA Standars No. 497M “The Contractor shall determine the appropriate electrical area cassification(s) for the project. ‘The Contractor shall prepare an area classifcation drawing, or drawings, detailing the areas covered by this design package. The drawing(s) shal be sufficient to identi full all areas and changes in type or level of hazard, a ee Bloque 61 Facilities & Construction wy Electrical Basis of Design | PETROAMAZONAS ‘Specification [rie | 1.35 Where areas are determined by process coraions to be corrosive (highly ‘acidic, caustic, et), the area classification drawing shal also define these ‘areas. Special condhit and equipment requirements wil be enforced for these 1.368 Construton drawings shall show the locations of al sal fitings, which are required. This shall include all seal ftingsrequred bythe NEC in condult runs passing through area classication boundaries. 113.7 Outdoc instalation shall be designed for atmospheric conditions per Company Standard. Al outdoor devioes shall have enclosures meeting NEMA 4X requirement as a minimum, 1.38 Enclosures for electrical equipment and devices shall be in accordance with hazardous area classification 1.2.9 The corr room(s) and electrical equipment room(s) shal be located ouside of the Cassiied area if possible. Ii s not possible to do this, a postive Pressure heating/air condoning system shall be designed with the following onsiderations &—Aminimum pressure of 0.10" up to.a maximum of 0.25" of water (25 to 152 Pa), within the space shall be maintained a all imes. b. Design shall be adequate to allow for 600-13 air volume through ‘openings. (For praccal purposes, assume one door open at atime) © An automatic alarm shal be Instaled to signal any pressure drop below 10.40" of water (25 Pa, ‘Alarm annuncaton for remote electical equipment rooms shall be provided inthe nearest corral room where practical. time delay of 30, Seconds plus 10 seconds per door to a maxomum of 1-1/2 minutes shall be Incorporated into the alarm system to allow for normal enty and ext 4. Dare. shall be exercised in selecing the location of the tot {uncontaminated) outside air source. This source shall be above or butside the classified area. For uncongested sites, @ vertical sack of ufficent height to reach an unclassified area is permissible. In some Sangested installations, it may be necessary to run horizontally fo an ‘nclaseiid area forthe tres air source, ©. ‘Whore possible, the fresh air duct shall bo postvely prossured to minimize duct leakage inwardly and contamination of the fresh sr. The pressurzation fan shall be independent from any al crcuation fan() 1. Tiremolor starter, role, el conto fo le pressure fas tal be suitable orth area in the absence of postive pressure ventlaton. AN ‘tomate standby source of power should be provided for the pressurization f 19. The mechenical equipment design shall be such that the noise evel in the contol room shall meet the requirements of Nose Standard V-1 fh. The purging system shall comply withthe above requirements and the requarements of the National Fite Protection Associaton, Code No. 496. \oe Bloque 61 Facilities & Construction w Electrical Basis of Design| PETROAMAZONAS: Speoification Revo Tre =] 18 16 7 Drawings and Specifications 1441 An electrical construction specification and an electrical constuction test ‘speciation outing requirements which shall be expanded of modited 10 meet poject requirements subject to Company approval, shall be given to all field electrical personne! to inform them of projet requirements. 142 Design drawings shall be prepared for use by construction and shall include area classication, grounding, ighiring protection, power and contol lighting, ‘one lines, schematic, wing, condult and cable schedties, 1443 Vendordranings shal be provided for purchased electrical equipment. Vendor srawings shall be used as is and shall not be redravin. Vendor prints shal be ho larger than 11,69" x 16.53" (AS). Final Vendor drawings shall become ‘Company property atthe end ofthe project. 41.44 Vendors shall furnish cerifed elementary and interconnection drawings, Materials and italian 1.51 The design effort includes specing the appropriate materials and equipment in accordance wit these design craria and cluded equipment specications, 41,52 All materials and equipment shall be new and free of defects and shall be the best quality of thor respective kinds. Materials Iisted and classtied by UL or FM shal be approved by UL of FM for the requied service, Materials shall be Uiictod types when avaiable fr the application, 1.53 Where several approved manufacturers are show for one type of materia, a ‘materia ofthat fype are to be ofthe same manufacturer, 1.54 Electrical equipment shall be of the Iype of construction specie in these spectiations and shall conform to the standards of the National Electrical Manufacturers Association, the American National Standards Insitute, and the Insitute of Electrical and Electronics Engineer. Werk Under Special Conditions Design shall be mad on the basis thatthe construction shall normally be done when ‘reuits arecisconnected and safe. Finshing| Equipment shal be finshed with ANSI 61 (indoor) or ANSI 70 (outdoor ght gray or manufacturers standard fnish and color when approved by Company. Equipment designated for outdoor service shall be painted with an outdoor palnt system In accordance with Company Specification, a 18 19 Bloque 64 ies & Construction Electrical Basis of Design PETROAMZONAS ‘Specification Revo [Pee | Identiiction 1.8.1. Each ibm of electical equipment shall be provided with an identfication tag showing Is tem number and service. The klenifcaion tag shall be three-py laminated plastic material engraved to show black lelleing on a wie background. motor dentifeaton tag shall be located beside the contol Stations at the motors and shall give the motor-driven equipment number and 41182 Unless otherwise noted, all felt.nstalled identification tags shall be securely fatiached utizing sianioss stool shouldered machine ‘screws. Adhesive ‘material alone isnot acceptable Power Supply and Distribution 41.9.1. The characteristics of the power supply with regard to main distribution voltage, utzon valtages, and system arcangement shall be generally as outined on the onerine aiagram() 1.92 The distbution system shall be designed on the basis of a simple radial distrouion. Transter of secondary bus tes shall be manual 1.93 Main Power and Key Power generation shall be connected to the main substaton bus. 41.94 Utlization substations shall be single ended with one transtomer. 41.85 The min substation shal house the 13.8 KV Switchgear Ineup, 4.18 kV motor contol, and 480-vol motor contol fr the generator aulianies and othr loads as outined in the onedine diagrams. Generaior control panels may be Included in the substation bulling Ifa practical and functional layout can be dovelored. 4.96 Substatons equipment shall be enclosed in a site constructed block type bulding, when practeal, with motor canal cantrs located indoors and power transformers cutdoors.' The transformers shall be connecied 10 Indoor ‘equpmant using cabie in condult or cable tay. Consideration shall be given 10 ‘tha doef cable bus or bus duc, when practi 1.8.7. The main substation and the utiization substations shall be equipped with separate force at HVAC systems (Each sys shall be oly eee ard ‘Szed to maintain BOF) The HVAC system shall be designed In accordance with Sestion 1.3.8 of tis specication I applicable, 1.88 The elestical equipment buiding, and areas shal be equipped with fluorescent lighting, convenience receptaces, parc hardware on the door, and adequate escape routes with emergency egress ightng 4.9.9 Tre man abstain and the ulilzation substations shal be sized o allow room for Company-fumished equipment. ‘Space shall be Included forthe addon of oe Bloque 61 ] Facilities & Construction w Electrical Basis of Design| PETROAMAZONAS ‘Specification [Reve [Pie 7 future starters (atleast 10% future), and a minimum of two vertical sections here switchgear is involved 1.910 Module constructon shall be of such design thet they can be expanded in cher dvection, were practical 1.9.11 Lighining surge protection shall be provided where required. When instal MOVAvpe arresters shal be uiized, 19.12 A Diesel engine-tiven standby-startup generator shall be provided, ‘directed by the Company. Equipment connected to the gonerator sh Essental process equipment and instrumentation, Standby ighting ‘AIG for contol room Prosswzation aystom for control roem and electrical equipment rooms (here required). “The generator KVA ating shall be lager than required to slat and run the Connected load. The equipment shall be furnished in accoréance with the Diesel Engine Generator Package Specfieaion 1.9.13 Motor Contol- General a. Motor control shall be reduced voltage, variable speed or full votage starting b. As a minimum, motor control equipment shall provide over current and shor-cicut.protecion plus three-phase temperature-compensated Dverload protection. & local momentary “Start-Stop” contol station wth Save contol shall 2e provided at each motor unless contol conditions demand another “ype of contol station, such as a local H-O-A, Motor contrl operation wil be per existing CPF design unless noted and approved by COMPANY. 4. Typical motor protection schemes shall be as folows: onesie faaest seca teen tete tos Seca tes cetera caieoae aed Shalem sseh teams ea a cates Sk Ca lin ame ae 2 Tama e tarteee nacre eu des ttiatae eeardee eee ee aioe ara ease patentee ne Se ee eet eae ee ape tt acta hns ‘Over temperature overload. Instantaneous over current Timelcurrent overload ce Bloque 61 Facilities & Construction w Electrical Basis of Design | PETROAMAZONAS. ‘Specification Revo Pia 8 Ground faut Phase unbalance Phase reversal. Beating over temperature, Open phase, Vibration 1.9.14 The system available fault curent wil be reviewer, and faut curent wil be limited elt through the use of added impedance to the transformers or through the use of current limiting fuses integral withthe MCC main breakers 1.9.19 Electrical equipment shall be designed for operation on the systems Isted below: 8. Formotors 1/2 to 800 HP non-neusive: 480 vols, 3 phases, 60 Hertz b. Formotors fom 500 HP inclusive and above: 4,160 volts, 3 phases, 60 Hertz, as spected, [Exceptions to this shall be reviewed and approved by COMPANY © Forffacional horsepower motors below 1/2 HP. 120Y, 1 phase, 60 Herz Process sence: Explosion proof enclosure. "Non-process service offce/shop): Open-

You might also like