9. TEST RECORD GROSS HEAT RATE

9.1. TEST RESULT OF HEAT RATE AT GENERATOR TERMINAL 11 KV

 Engine Set No. 1


Date : 20 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 18.35 WIB kWh 770590 793270 801460

2 Active Energy Export at 20.35 WIB kWh 790090 800590 806430

3 Gross Power Output kWh 19500 7320 4970

4 Gas Consumption at 18.35 WIB kg 126020 129707 131085

5 Gas Consumption at 20.35 WIB kg 129179 130934 131954

6 Gas Consumption kg 3159 1227 869

7 LHV kJ/kg 48354.05 48354.05 48354.05

8 Gross Heat Rate kJ/kWh 7837.56 8105.25 8610.58

9 Gross Heat Rate BTU/kWh 7431.03 7682.29 8161.26

10 Gross Heat Rate -3% tolerance BTU/kWh 7208.09 7451.82 7916.42

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 59 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
60 of 103
 
9.2. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 2


Date : 20 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 18.35 WIB kWh 785180 807910 816080

2 Active Energy Export at 20.35 WIB kWh 804650 815210 820950

3 Gross Power Output kWh 19470 7300 4870

4 Gas Consumption at 18.35 WIB kg 126383 129707 131371

5 Gas Consumption at 20.35 WIB kg 129491 130934 132216

6 Gas Consumption kg 3108 1227 845

7 LHV kJ/kg 48354.05 48354.05 48354.05

8 Gross Heat Rate kJ/kWh 7722.91 7955.23 8389.97

9 Gross Heat Rate BTU/kWh 7322.32 7540.10 7952.16

10 Gross Heat Rate -3% tolerance BTU/kWh 7102.65 7313.90 7713.59

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 60 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
61 of 103
 
9.3. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 3


Date : 21 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 02.14 kWh 810630 779190 784930

2 Active Energy Export at 01.14 kWh 800850 771890 780070

3 Gross Power Output kWh 9780 7300 4860

4 Gas Consumption at 02.14 kg 132107 126914 127924

5 Gas Consumption at 01.14 kg 130531 125699 127066

6 Gas Consumption kg 1576 1215 858

7 LHV kJ/kg 48354.05 48354.05 48354.05

8 Gross Heat Rate kJ/kWh 7796.20 8047.96 8536.57

9 Gross Heat Rate BTU/kWh 7391.82 7628.00 8091.11

10 Gross Heat Rate -3% tolerance BTU/kWh 7170.06 7399.16 7848.38

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 61 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
62 of 103
 
9.4. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 4


Date : 20 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 18.35 WIB kWh 800200 822990 831190

2 Active Energy Export at 20.35 WIB kWh 819710 830310 836070

3 Gross Power Output kWh 19510 7320 4880

4 Gas Consumption at 18.35 WIB kg 127432 131030 132366

5 Gas Consumption at 20.35 WIB kg 130504 132219 133197

6 Gas Consumption kg 3072 1189 831

7 LHV kJ/kg 48354.05 48354.05 48354.05

8 Gross Heat Rate kJ/kWh 7613.72 7854.23 8234.06

9 Gross Heat Rate BTU/kWh 7218.79 7444.37 7804.38

10 Gross Heat Rate -3% tolerance BTU/kWh 7002.22 7221.04 7570.25

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 62 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
63 of 103
 
9.5. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No.5


Date : 20 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 18.35 WIB kWh 802820 825540 833370

2 Active Energy Export at 20.35 WIB kWh 822270 832850 838600

3 Gross Power Output kWh 19450 7310 5230

4 Gas Consumption at 18.35 WIB kg 132345 136056 137446

5 Gas Consumption at 20.35 WIB kg 135508 137290 138323

6 Gas Consumption kg 3111 1234 877

7 LHV kJ/kg 48354.05 48354.05 48354.05

8 Gross Heat Rate kJ/kWh 7863.43 8162.63 8707.70

9 Gross Heat Rate BTU/kWh 7455.56 7736.68 8253.30

10 Gross Heat Rate -3% tolerance BTU/kWh 7231.89 7504.58 8005.70

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 63 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
64 of 103
 
9.6. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 6


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 982020 992100 997950

2 Active Energy Export at 15.00 kWh 962490 984770 993060

3 Gross Power Output kWh 19530 7330 4890

4 Gas Consumption at 17.00 kg 157634 159318 160351

5 Gas Consumption at 15.00 kg 154466 158087 159484

6 Gas Consumption kg 3168 1231 867

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7820.23 8114.26 8311.57

9 Gross Heat Rate BTU/kWh 7414.60 7690.83 7877.85

10 Gross Heat Rate -3% tolerance BTU/kWh 7162.16 7460.11 7641.52

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 64 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
65 of 103
 
9.7. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 7


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 1020780 1030870 1036730

2 Active Energy Export at 15.00 kWh 1001240 1023530 1031830

3 Gross Power Output kWh 19540 7340 4900

4 Gas Consumption at 17.00 kg 164253 165947 166988

5 Gas Consumption at 15.00 kg 161082 164710 166114

6 Gas Consumption kg 3171 1237 874

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7823.63 8142.70 8329.10

9 Gross Heat Rate BTU/kWh 7417.82 7717.79 7894.47

10 Gross Heat Rate BTU/kWh 7195.28 7486.26 7657.63

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 65 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
66 of 103
 
9.8. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 8


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 1022780 1032840 1038690

2 Active Energy Export at 15.00 kWh 1003270 1025530 1033810

3 Gross Power Output kWh 19510 7310 4880

4 Gas Consumption at 17.00 kg 163377 165057 166084

5 Gas Consumption at 15.00 kg 160222 163831 165224

6 Gas Consumption kg 3155 1226 860

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7796.13 8103.41 8163.48

9 Gross Heat Rate BTU/kWh 7391.74 7680.55 7737.49

10 Gross Heat Rate -3% tolerance BTU/kWh 7169.98 7450.13 7505.36

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 66 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
67 of 103
 
9.9. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 9


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 1011820 1021900 1027760

2 Active Energy Export at 15.00 kWh 992300 1014580 1022870

3 Gross Power Output kWh 19520 7320 4890

4 Gas Consumption at 17.00 kg 162512 164210 165256

5 Gas Consumption at 15.00 kg 159345 162971 164379

6 Gas Consumption kg 3167 1239 877

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7821.77 8178.15 8259.94

9 Gross Heat Rate BTU/kWh 7416.06 7751.39 7828.91

10 Gross Heat Rate -3% tolerance BTU/kWh 7193.57 7518.85 7594.05

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 67 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
68 of 103
 
9.10. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 10


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 1001400 1011480 1017330

2 Active Energy Export at 15.00 kWh 981900 1004160 1012450

3 Gross Power Output kWh 19500 7320 4880

4 Gas Consumption at 17.00 kg 157501 159159 160170

5 Gas Consumption at 15.00 kg 154390 157950 159324

6 Gas Consumption kg 3111 1209 846

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7691.34 7980.13 7937.03

9 Gross Heat Rate BTU/kWh 7292.39 7563.70 7522.85

10 Gross Heat Rate -3% tolerance BTU/kWh 7073.61 7336.79 7297.16

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 68 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
69 of 103
 
9.11. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 11


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 841570 851560 857380

2 Active Energy Export at 15.00 kWh 822070 844250 852510

3 Gross Power Output kWh 19500 7310 4870

4 Gas Consumption at 17.00 kg 133763 135430 136452

5 Gas Consumption at 15.00 kg 130616 134205 135592

6 Gas Consumption kg 3147 1225 860

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7780.35 8096.80 8532.26

9 Gross Heat Rate BTU/kWh 7376.78 7674.29 8087.02

10 Gross Heat Rate -3% tolerance BTU/kWh 7155.47 7444.06 7844.41

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 69 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
70 of 103
 
9.12. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 12


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 844960 854980 860810

2 Active Energy Export at 15.00 kWh 825450 847660 855930

3 Gross Power Output kWh 19510 7320 4880

4 Gas Consumption at 17.00 kg 134320 135989 137015

5 Gas Consumption at 15.00 kg 131166 134764 136153

6 Gas Consumption kg 3154 1225 862

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7793.66 8085.74 8534.58

9 Gross Heat Rate BTU/kWh 7389.40 7663.80 8089.22

10 Gross Heat Rate -3% tolerance BTU/kWh 7168.71 7433.89 7846.54

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 70 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
71 of 103
 
9.13. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 13


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 868530 878540 884350

2 Active Energy Export at 15.00 kWh 849060 871230 879490

3 Gross Power Output kWh 19470 7310 4860

4 Gas Consumption at 17.00 kg 137972 139639 140664

5 Gas Consumption at 15.00 kg 134827 138417 139803

6 Gas Consumption kg 3145 1222 861

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7787.38 8076.97 8559.76

9 Gross Heat Rate BTU/kWh 7383.45 7655.49 8113.09

10 Gross Heat Rate -3% tolerance BTU/kWh 7161.94 7425.83 7869.69

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 71 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
72 of 103
 
9.14. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 14


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 883730 893750 899950

2 Active Energy Export at 15.00 kWh 864230 886440 894710

3 Gross Power Output kWh 19500 7310 5240

4 Gas Consumption at 17.00 kg 141656 143343 144380

5 Gas Consumption at 15.00 kg 138478 142107 143509

6 Gas Consumption kg 3178 1236 871

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7856.99 8169.51 8623.69

9 Gross Heat Rate BTU/kWh 7449.45 7743.20 8173.68

10 Gross Heat Rate -3% tolerance BTU/kWh 7225.96 7510.90 7928.47

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 72 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
73 of 103
 
9.15. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 15


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 844340 854390 860250

2 Active Energy Export at 15.00 kWh 824820 847060 855350

3 Gross Power Output kWh 19520 7330 4900

4 Gas Consumption at 17.00 kg 134489 136169 137202

5 Gas Consumption at 15.00 kg 131330 134939 136334

6 Gas Consumption kg 3159 1230 868

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7802.01 8107.67 8558.91

9 Gross Heat Rate BTU/kWh 7397.32 7684.58 8112.28

10 Gross Heat Rate -3% tolerance BTU/kWh 7175.40 7454.05 7868.91

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 73 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
74 of 103
 
9.16. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 16


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 844730 854740 860570

2 Active Energy Export at 15.00 kWh 825250 847440 855700

3 Gross Power Output kWh 19480 7300 4870

4 Gas Consumption at 17.00 kg 133720 135382 136398

5 Gas Consumption at 15.00 kg 130586 134165 135546

6 Gas Consumption kg 3134 1217 852

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7756.16 8054.94 8452.89

9 Gross Heat Rate BTU/kWh 7353.85 7634.61 8011.80

10 Gross Heat Rate -3% tolerance BTU/kWh 7133.23 7405.57 7771.44

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 74 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
75 of 103
 
9.17. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 17


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 858410 868430 874260

2 Active Energy Export at 15.00 kWh 838940 861130 869390

3 Gross Power Output kWh 19470 7300 4870

4 Gas Consumption at 17.00 kg 137415 139102 140138

5 Gas Consumption at 15.00 kg 134247 137867 139269

6 Gas Consumption kg 3168 1235 569

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7844.33 8174.08 8621.55

9 Gross Heat Rate BTU/kWh 7437.45 7747.53 8171.66

10 Gross Heat Rate -3% tolerance BTU/kWh 7214.32 7515.11 7926.51

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 75 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
76 of 103
 
9.18. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 18


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 925320 935350 941180

2 Active Energy Export at 15.00 kWh 905840 928040 936310

3 Gross Power Output kWh 19480 7310 4870

4 Gas Consumption at 17.00 kg 146000 147657 148668

5 Gas Consumption at 15.00 kg 142872 146445 147821

6 Gas Consumption kg 3128 1212 847

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7741.31 8010.88 8403.29

9 Gross Heat Rate BTU/kWh 7339.77 7592.84 7964.78

10 Gross Heat Rate -3% tolerance BTU/kWh 7119.57 7365.06 7725.84

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 76 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
77 of 103
 
9.19. TEST RECORD OF HEAT RATE AT GENERATOR TERMINAL 11 kV

 Engine Set No. 19


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Active Energy Export at 17.00 kWh 915750 925790 931620

2 Active Energy Export at 15.00 kWh 896280 918480 926750

3 Gross Power Output kWh 19470 7310 4870

4 Gas Consumption at 17.00 kg 146847 148537 149576

5 Gas Consumption at 15.00 kg 143671 147301 148705

6 Gas Consumption kg 3176 1236 871

7 LHV kJ/kg 48316.45 48316.45 48316.45

8 Gross Heat Rate kJ/kWh 7864.14 8169.51 8641.40

9 Gross Heat Rate BTU/kWh 7456.23 7743.20 8190.46

10 Gross Heat Rate -3% tolerance BTU/kWh 7232.54 7510.90 7944.75

11 Heat Rate Guarantee BTU/kWh 7263 7493 7913

Page 77 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
78 of 103
 
10. TEST RECORD OF HEAT RATE AT ENGINE COUPLING

10.1. TEST RECORD OF HEAT RATE AT ENGINE COUPLING


 

 Engine Set No. 1


Date : 20 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19500 7320 4880

2 Gas Consumption at 17.00 kg 129178 130934 131954

3 Gas Consumption at 15.00 kg 126020 129707 131085

4 Gas Consumption kg 3158 1227 869

5 LHV kJ/kg 48354.05 48354.05 48354.05

6 Gross Heat Rate kJ/kWh 7830.87 7935.03 8395.32

7 Gross Heat Rate BTU/kWh 7422.23 7520.96 7957.23

8 Gross Heat Rate -3% tolerance BTU/kWh 7199.56 7295.33 7718.51

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 78 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
79 of 103
 
10.2. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 2


Date : 20 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19470 7300 4870

2 Gas Consumption at 17.00 kg 129491 131223 132216

3 Gas Consumption at 15.00 kg 126383 130022 131371

4 Gas Consumption kg 3108 1201 845

5 LHV kJ/kg 48354.05 48354.05 48354.05

6 Gross Heat Rate kJ/kWh 7718.76 7788.17 8180.22

7 Gross Heat Rate BTU/kWh 7315.97 7381.76 7753.35

8 Gross Heat Rate -3% tolerance BTU/kWh 7096.49 7160.31 7520.75

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 79 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
80 of 103
 
10.3. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 3


Date : 21 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 9780 7300 4860

2 Gas Consumption at 02.14 kg 132107 126914 127924

3 Gas Consumption at 01.14 kg 130531 125699 127066

4 Gas Consumption kg 1576 1215 858

5 LHV kJ/kg 48354.05 48354.05 48354.05

6 Gross Heat Rate kJ/kWh 7636.18 7878.96 8323.16

7 Gross Heat Rate BTU/kWh 7240.09 7467.81 7888.83

8 Gross Heat Rate -3% tolerance BTU/kWh 7022.89 7243.77 7652.17

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 80 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
81 of 103
 
10.4. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 4


Date : 20 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19510 7320 4880

2 Gas Consumption at 17.00 kg 159345 132219 133197

3 Gas Consumption at 15.00 kg 162512 131030 132366

4 Gas Consumption kg 3167 1189 831

5 LHV kJ/kg 48354.05 48354.05 48354.05

6 Gross Heat Rate kJ/kWh 7849.16 7689.29 8028.20

7 Gross Heat Rate BTU/kWh 7439.57 7288.04 7609.27

8 Gross Heat Rate -3% tolerance BTU/kWh 7216.38 7069.40 7380.99

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 81 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
82 of 103
 
10.5. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 5


Date : 20 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19450 7310 4870

2 Gas Consumption at 17.00 kg 154390 137290 138323

3 Gas Consumption at 15.00 kg 157501 136056 137446

4 Gas Consumption kg 3111 1234 877

5 LHV kJ/kg 48354.05 48354.05 48354.05

6 Gross Heat Rate kJ/kWh 7734.16 7991.22 8490.00

7 Gross Heat Rate BTU/kWh 7330.57 7574.21 8046.97

8 Gross Heat Rate -3% tolerance BTU/kWh 7110.65 7346.99 7805.56

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 82 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
83 of 103
 
10.6. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 6


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19530 7330 4890

2 Gas Consumption at 17.00 kg 157634 159318 160351

3 Gas Consumption at 15.00 kg 154466 158087 159484

4 Gas Consumption kg 3168 1231 867

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7837.50 7943.86 8352.37

7 Gross Heat Rate BTU/kWh 7428.52 7529.32 7916.52

8 Gross Heat Rate -3% tolerance BTU/kWh 7205.66 7303.45 7679.02

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 83 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
84 of 103
 
10.7. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 7


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19540 7340 4900

2 Gas Consumption at 17.00 kg 164253 165947 166988

3 Gas Consumption at 15.00 kg 161082 164710 166114

4 Gas Consumption kg 3171 1237 874

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7847.01 7971.70 8402.62

7 Gross Heat Rate BTU/kWh 7437.53 7555.72 7964.15

8 Gross Heat Rate -3% tolerance BTU/kWh 7214.40 7329.04 7725.22

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 84 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
85 of 103
 
10.8. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 8


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19510 7310 4880

2 Gas Consumption at 17.00 kg 163377 165057 166084

3 Gas Consumption at 15.00 kg 160222 163831 165224

4 Gas Consumption kg 3155 1226 860

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7813.34 7933.24 8301.91

7 Gross Heat Rate BTU/kWh 7405.62 7519.26 7868.69

8 Gross Heat Rate -3% tolerance BTU/kWh 7183.45 7293.68 7632.63

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 85 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
86 of 103
 
10.9. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 9


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE

VALUE (75%) (50%)

(100%)

1 Gross Power Output kWh 19520 7320 4890

2 Gas Consumption at 17.00 kg 162512 164210 165256

3 Gas Consumption at 15.00 kg 159345 162971 164379

4 Gas Consumption kg 3167 1239 877

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7845.14 8006.41 8448.70

7 Gross Heat Rate BTU/kWh 7435.76 7588.61 8007.83

8 Gross Heat Rate -3% tolerance BTU/kWh 7212.68 7360.95 7767.59

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 86 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
87 of 103
 
10.10. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 10


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19500 7320 4880

2 Gas Consumptions at 17.00 kg 157501 159159 160170

3 Gas Consumption at 15.00 kg 154390 157950 159324

4 Gas Consumption kg 3111 1209 846

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7708.33 7812.55 8166.76

7 Gross Heat Rate BTU/kWh 7306.08 7404.87 7740.60

8 Gross Heat Rate -3% tolerance BTU/kWh 7086.89 7182.72 7508.38

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 87 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
88 of 103
 
10.11. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 11


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19500 7310 4870

2 Gas Consumption at 17.00 kg 133763 135430 136452

3 Gas Consumption at 15.00 kg 130616 134205 135592

4 Gas Consumption kg 3147 1225 860

5 LHV kJ/kg 48316.45  48316.45  48316.45 

6 Gross Heat Rate kJ/kWh 7803.60 7926.77 8318.96

7 Gross Heat Rate BTU/kWh 7396.38 7513.13 7884.85

8 Gross Heat Rate -3% tolerance BTU/kWh 7174.48 7287.73 7648.30

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 88 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
89 of 103
 
10.12. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 12


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19510 7320 4880

2 Gas Consumption at 17.00 kg 134320 135989 137015

3 Gas Consumption at 15.00 kg 131166 134764 136153

4 Gas Consumption kg 3154 1225 862

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7810.87 7915.94 8321.22

7 Gross Heat Rate BTU/kWh 7403.27 7502.86 7886.99

8 Gross Heat Rate -3% tolerance BTU/kWh 7181.17 7277.78 7650.38

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 89 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
90 of 103
 
10.13. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 13


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19470 7310 4860

2 Gas Consumption at 17.00 kg 137972 139639 140664

3 Gas Consumption at 15.00 kg 134827 138417 139803

4 Gas Consumption kg 3145 1222 861

5 LHV kJ/kg 48316.45 48316.45  48316.45 

6 Gross Heat Rate kJ/kWh 7810.65 7907.36 8345.77

7 Gross Heat Rate BTU/kWh 7403.07 7494.73 7910.26

8 Gross Heat Rate -3% tolerance BTU/kWh 7180.97 7269.88 7672.95

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 90 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
91 of 103
 
10.14. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 14


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19500 7310 4880

2 Gas Consumption at 17.00 kg 141656 143343 144380

3 Gas Consumption at 15.00 kg 138478 142107 143509

4 Gas Consumption kg 3178 1236 871

5 LHV kJ/kg 48316.45 48316.45  48316.45 

6 Gross Heat Rate kJ/kWh 7874.34 7997.95 8408.10

7 Gross Heat Rate BTU/kWh 7463.43 7580.59 7969.34

8 Gross Heat Rate -3% tolerance BTU/kWh 7239.52 7353.17 7730.26

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 91 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
92 of 103
 
10.15. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 15


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19520 7330 4900

2 Gas Consumption at 17.00 kg 134489 136169 137202

3 Gas Consumption at 15.00 kg 131330 134939 136334

4 Gas Consumption kg 3159 1230 868

5 LHV kJ/kg 48316.45 48316.45  48316.45 

6 Gross Heat Rate kJ/kWh 7825.33 7937.41 8344.94

7 Gross Heat Rate BTU/kWh 7416.98 7523.21 7909.47

8 Gross Heat Rate -3% tolerance BTU/kWh 7194.47 7297.51 7672.19

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 92 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
93 of 103
 
10.16. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 16


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19480 7300 4870

2 Gas Consumption at 17.00 kg 133720 135382 136398

3 Gas Consumption at 15.00 kg 130586 134165 135546

4 Gas Consumption kg 3134 1217 852

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7773.29 7885.79 8241.57

7 Gross Heat Rate BTU/kWh 7367.66 7474.29 7811.50

8 Gross Heat Rate -3% tolerance BTU/kWh 7146.63 7250.06 7577.16

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 93 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
94 of 103
 
10.17. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 17


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19470 7300 4870

2 Gas Consumption at 17.00 kg 137415 139102 140138

3 Gas Consumption at 15.00 kg 134247 137867 139269

4 Gas Consumption kg 3168 1235 869

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7867.77 8002.42 8406.02

7 Gross Heat Rate BTU/kWh 7457.21 7584.83 7967.37

8 Gross Heat Rate -3% tolerance BTU/kWh 7233.49 7357.29 7728.34

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 94 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
95 of 103
 
10.18. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 18


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19480 7310 4870

2 Gas Consumption at 17.00 kg 146000 147657 148668

3 Gas Consumption at 15.00 kg 142872 146445 147821

4 Gas Consumption kg 3128 1212 847

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7758.41 7842.65 8193.20

7 Gross Heat Rate BTU/kWh 7353.55 7433.39 7765.66

8 Gross Heat Rate -3% tolerance BTU/kWh 7132.94 7210.39 7532.69

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 95 of 103 
 
GAS ENGINE POWER PLANT 184 MW

ARUN LOCATION
PT. WIJAYA KARYA (PERSERO) Tbk. PT.PLN (Persero)

Document No. Rev. 0


TEST RECORD OF
Page Number
WIKA-12NE12-20-REP-0100-012 PERFORMANCE TEST
96 of 103
 
10.19. TEST RECORD OF HEAT RATE AT ENGINE COUPLING
 

 Engine Set No. 19


Date : 15 December 2015

NO PARAMETER UNIT VALUE VALUE VALUE

(100%) (75%) (50%)

1 Gross Power Output kWh 19470 7310 4870

2 Gas Consumption at 17.00 kg 146847 148537 149576

3 Gas Consumption at 15.00 kg 143671 147301 148705

4 Gas Consumption kg 3176 1236 871

5 LHV kJ/kg 48316.45 48316.45 48316.45

6 Gross Heat Rate kJ/kWh 7887.64 7997.95 8425.36

7 Gross Heat Rate BTU/kWh 7476.04 7580.59 7985.70

8 Gross Heat Rate -3% tolerance BTU/kWh 7251.75 7353.17 7746.13

9 Heat Rate Guarantee BTU/kWh 7059 7285 7662

Page 96 of 103 
 