You are on page 1of 2
Intrinsically Safe Multimeters MX 51 Ex €) LCIE approved! Group | Group | and II Group II Sila lil ba Reman) iui ae Intrinsically Safe Multimeter MX 51 Ex + LCIE approvals : - Group 192. C8003 X; category EEx ib | - Group Il 91. C6063 X; category EEX ib (zone 1) IICT6 + 5000 count resolution ; 0.1% basic accuracy + Autoranging operation + Bargraph with zoom (0.4% resolution) and LIVE TREND MEMORY MODE + 50mADC range features 0.1% accuracy for 4-20 mA current loop measurements + Relative and MIN/MAX recording modes * Logic level detection mode + Memory to store five readings + IP 66 waterproof housing + Protected by 500 mA intrinsically safe and 10 AHBC fuses (both are user replaceable) ‘The MX 51 Ex series are intrinsically safe mutimeters which are approved for use in potentially explosive atmospheres in hazardous areas. The approval covers measurements of votage up to60V, current up to 500 mA and resistance. Also, continuity and diode tests, plus logic level detection In addition to these intrinsic safety features, the MX 51 Ex ‘muitimeters include all the advantages offered by the ASYC. ‘Advanced Safety Concept. irement rate : 2/sec digital, 10/sec bargraph ‘Series mode rejection : 60 dB ‘Common mode rejection 420 dB AG/DC - 60 dB AG/AC Reference range : +18'C to +28°C ‘Operating range : -10°C to +50°C; < 40°C inthe Ex safe area (operation at 40°C for 20 minutes provided unit started at 20°C) Storage :- 40°C to + 80°C (without battery) Relative humidity : 010 80% (Oto 40°C) 0t070% (40°C to 50°C) Temperature coefficient : 0.1 x specific accuracy/ °C Sealing/Shock : 1P 687 and MIL T 28600-2 ‘ADP (Adaptor) : 500 mV DC range for use external accessories, Safety class I: IEC 348 , VDE 0411, BS 4743 ‘Three versions cover differnt Gas Groups : |, lor and I Technical Specifications MX 51 Ex Version A B ] Cc | a omer | armpit | crmpt | tesson | cui Display St er ($9 ln pon oon +8 cro Son ignsie “Swiowvom tae ania meee cont aa ane ® view ed Ne ey. kaa a8 ay em ag Pe ag Fs Baar sy wT ome (sr [vonage protection peak 0 70 GAREY ALERT hud arn trnge needed ©. wom sitintas EE storarging {| Vac aoe | Enmane [Resistance ‘Ranges ‘Resolution Test yoltage [Peet weGernnesg 018 comm | SEP oan Sn shpat Sa cullen Stoo ‘ausenn cme [Grea range ie 20 ow gunn tone ‘omen oan S00 gh heqane toe Resistance protection [ADP (adaptor) input (a eter Diode test z Electromagnetic Compatibility Interference : VDE 871 cl, B and MIL STD 461 REO2 Susceptability: IEC 801 and MIL STD 461 RSO3 Intrinsic safety : EN 50020 and EN 50014 Power supply :9V6LF22 battery; Auto switch off ater 30 mins. Battery lite: > 500 hours Dimensions : 40 x 82x 189mm ‘Weight : 400 g Housing colour : Safety yellow ‘Supplied with type AE 193 carrying case. Specifications are subject to change without notice Distributed by me FTTComposants et Instruments Division Instruments Metrix Chemin de la Cro Rouge - 8, 30 F 74010 Annecy Cedex ‘Tel. 505281 02 - Fax 50.51 7093, ITT Instruments 346 Edinburgh Avenue ‘ough, Berks SLI 4TU Tel. (0753) 51799 - Fax (0758) 694063, TAS EXS1 938

You might also like