You are on page 1of 4
Controlled OMEGA METER MODEL 600 SMD System Description: PROMPTING DISPLAY — The system display prompis all ‘ala entries in simple commands to the operator. and provides a continuing presentation of changing test measurements. SYSTEM PRINTER — White the testis in progress, a dot matrix printer develops a hard-copy ‘chart of the contamination curve Data points are plotted every ten seconds. At test termination, the final contamination level, test parameters, and passfal status Of the test sample are printed. Provision is also made to print ‘out the data bank. NON-VOLATILE DATA BANK — Memory is available to store dala on up to 30 samples including Sample Code Number, Customer Identification Number, and Sample Surface Area’ The system also retains the most recently entered test solution ‘concentration, HEATED TEST SOLUTION — Heating the test solution is a key factor in the overall performance of the Model 600 SMD. ‘Omega Meter. The dissolution of all contaminants is accelerated mary times by raising the operating temperature to 110" 125 °F. ‘The system is preset at 120°F and employs a fan cooled pe 2 rave excessive neat rsuting fam fi ton in ie Pump and test cell. An insulated stainless steel reservoir is. provided with an external low watt-density heating element and 8 very sensitive overtemp protect circuit preset at 130'F. System warm-up requires approximately 45 minutes and the actual operating temperature wil ange from 110 -125°F depending upon the size of test cell being used and the ambient temperature of ar surrounding the instrument, ELECTRICAL VERIFICATION — No electronic calibration is Necessary. This procedure permits veriication of the resistivity ‘measuring circu accuracy. Should this crculry fail to operate properly the system stops and an approprate falure notice appears on the display CHEMICAL VERIFICATION — This procedure allows Confirmation of performance oi all system components, from the ‘measurement probe to the system printer AUTOMATIC TEST TERMINATION — The operator can specily the test cycle time, or if selected, the system will terminate automatically when the contamination level stabilzes ‘and remains unchanged for a steady 4 minute period RS-282-C DATA TRANSFER PORT — An I8M-compatible ‘serial port's provided on the rear of the instrument for periodic transfer of test dala. Memory is provided to store approximately 20 ten minute tests belore an actual transler is required Software for driving the host computer and the Omega Metet, aa the por, is supplied with the system on a floppy disk. Only dala transfer can be accomplished via the port as the systems will not be interactive INTERCHANGEABLE TEST CELLS — Four different test cell sizes (6°x8", 12°12", 12x18", 18x18") allow for optimized test solution to board surface area ratio. Ideal performance is achieved at a ratio of 36 cc/sq, inch, however, very accurate results are also achieved at ratios as high as 100 ‘ec/5q. inch. All test cells are equipped with submerged spray jets to improve penetration under components and to control the rapid flushing action within the test cell An intake manifold along the entire bottom of the test cels further disibutes and Ccolumnizes the 10 - 18 GPM flow rate of the test solution. Actual ‘changing of the calls involves loosening 3 base clamps and replacing one test cell with another. An average of 10 minutes is required for this procedure. SOLUTION VOLUME INDICATOR — The system reservoir incorporates a calibrated sight panel which allows a direct reading of total eystern solution volume. Theory Of Operation: The Omega Meter Model 600 SMD determines the quantity {1 ionic contamination on a specimen under test by montoring the resistivity of a fixed amount of heated test solution used to extract and dissolve contaminants The system detects and records the amount of contamination in the test call at the beginning of the test to establish a base line. Subsequent calculations represent only the amount of ‘contamination added to the extract solution during the test A state of equilibrium 's attained when all the contaminants have disolved inio the extract test solution. Typical time for this equilibrium to occur is trom § to 10 minutes on thrushole ‘boards and 30 to 45 minutes on SMD boards At the conclusion of the test, the final contamination level, in equivalent merograms of NaCl / sq. in. is printed along with the fest parameters and a passfall situs of the test sample based on predetermined entra, Belore running another test, he solution is regenerated through a bultin deorizing system to estabish a clean solution and a new base line for the next test. The Omega Meter 600 SMD Advances Technology ‘The Omega Meter 600 SMD System is a seltcontained, mictoprocessorcontrolled instrument designed 10 perform now destructive tests for ionic contamination levels on printed circul boards and related components. By measuring the change in, Sw resistivity of test solution the system determines the ‘amount of contamination bbeing removed from the test specimen, This SMD version Of Alpha Metais’ Omega Meter 600 takes proven technology a step further By heating the test solution to approximately 120° F and ‘adding submerged spray jets at strategc points in the test cell, cleaning efficiency is raised to an impressive 90-95% on high density SMD circuit board assembles. Special Features: ‘+ MICROPROCESSOR-CONTROLLED * ALL DATA ENTRIES PROMPTED FROM DISPLAY FOR SIMPLE, USER FRIENDLY OPERATION * DATA BANK STORAGE FOR UP TO 30 SAMPLES ‘* PRINTOUT OF CONTAMINATION CURVE AND ALL TEST PARAMETERS + AUTOMATIC TEST TERMINATION ‘* HEATED TEST SOLUTION FOR IMPROVED ‘SOLUBILITY OF CONTAMINANTS ‘+ SUBMERGED SPRAY JETS IN TEST CELL FOR INCREASED PENETRATION ‘* RAPID PUMPING RATE OF TEST SOLUTION (SOLUTION TURN—OVER 3 TO 5 TIMES / MIN) ACCELERATES IONIC EXTRACTION * INTERCHANGEABLE TEST CELLS ALLOW TESTING OF VERY LARGE AND VERY SMALL SAMPLES — CHOOSE FROM 4 TEST CELLS: 8x8", 12x12", 12x18", 18x18" + RS-232-C PORT WITH MEMORY — IBM COMPATIBLE ‘STORES 299 MINUTES OF TEST DATA * ENGLISH / METRIC SWITCHABLE Applications: The Omega Meter Mode 600 SMO serves as an effective and practical quality assurance tool for a wide range of commercial applications In miltary applications, the Omega Meter systom provides an accurate, repeatable and rapid method for determining compliance with cleanliness standards required by Miltary Specitication MIL-P-28808. ‘The Omega Meter Model 600 SMD can also be used to: ‘© DETERMINE COMPLIANCE WITH MIL-P-55110, MILITARY SPECIFICATION — PRINTED WIRING ASSEMBLIES © DETERMINE THE QUALITY OF ELECTRONIC COMPONENTS AND PRINTED WIRING BOARDS DURING INCOMING INSPECTION * EVALUATE VARIOUS SOLDERING FLUXES OR DEVELOP DATA TO DETERMINE A * EVALUATE THE CLEANING CAPABILITIES OF VARIOUS DEFLUXING SOLVENTS OR SAPONIFIERS ‘© CHECK THE FINAL CLEANLINESS OF SURFACES PRIOR TO THE APPLICATION OF CONFORMAL COATINGS AND POTTING COMPOUNDS Physical Data: ‘System Dimensions: 38" wide x 29" deep x 54" high Power Requirements: 230 volts, 60 hz., 10 amps Shipping Dimensions: ‘44” wide x 33" deep x 76" high POSSIBLE SWITCH TO MORE EFFECTIVE Shipping Weight: CLEANING METHODS 600 Pound’ Website : www.eastco-hk.com iG wT A al EASTCO LIMITED HONGKONG HEAD OFFICE SHENZHEN OFFICE SHANGHA OFFICE Flat 25,2, Thriving nd. Cert, 26.38 Sa Teui Rod, Tsuen Wan, IN, Hong Kong “el: (952)2456 1823, Fax: (852) 2460 1767 mal nfo@oasio hk com © enact: Ras EASTCO INSTRUMENT (SHENZHEN) CO.,LTD Rm 1810, 18, 701 HutalRoad, iF, SOTEC Bldg, Road Bagua 4 Bagualing, ‘Shenzhen China Postal Code 518029 “Tol: (85-755) 8241 3800 Fax (86-755) 8241 3857 mai: shenzhen@eastco-h.com ‘Shanghai, PR. China| Petal Code : 200072 Tel: 86-21) 5659 6311 Fx: (86-21) 5553 6309 malt shanghal@eestoo hk com

You might also like