Nortec® 500 Series

Flaw Detectors

Features

■■ 50 Hz - 12 MHz frequency range

■■ Preamplifier (0 or 14dB)

■■ Single Li-Ion battery, Choice of two


battery configurations: 2.4 Ahr or 8.8 Ahr

■■ Lightweight, 2.8 lbs to 3.8 lbs


(1.2 kg to 1.7 kg) depending on battery
configuration

■■ 6.5” (165 mm) full VGA color LCD


(640 x 480 resolution)

■■ On-board storage of up to 200 programs

Eddy Current Flaw Detectors


■■ On-screen reference memory for go
no/go applications

The Nortec 500 Series, Olympus NDT’s The optional remote-null adapter adds ■■ Internal balance loads for single coil
newest eddy current flaw detectors convenience by allowing the probe to be probe support
incorporate a full range of features: internal nulled and the instrument screen erased
balance coils, VGA output connector from the probe. ■■ Display Freeze to hold flaw signals
(for heads up displays, monitors, and Where weight is critical, the smaller ■■ PowerLink™ technology - automatic
projectors), and a USB interface for rapid battery lightens the instrument to 2.8
information transfer. The Nortec 500 also probe recognition and instrument set-up
lbs (1.2 kg) while keeping the full VGA
includes PowerLink™, for automatic probe resolution and display size. ■■ Foreign Object Debris (FOD) free case
recognition and program set-up.
The Nortec 500 delivers basic single design
The Nortec 500 improves on previous frequency eddy current inspection
Nortec eddy current instruments and is including external outputs. ■■ VGA output
available in four configurations. Each
configuration includes USB port and The Nortec 500C adds digital conductivity
increased resolution with reduced noise. and coating thickness measurement
Internal balance coils allow use of capability in addition to basic single
inexpensive absolute probes without the frequency eddy current inspection.
need for external balance coil adapters. The Nortec 500S builds on the foundation
A built-in preamp adds extra gain when of the N500C and adds the ability to use
needed for difficult tests. VGA output rotating scanners.
allows for the addition of a optional “heads
The Nortec 500D adds dual frequency
up display” allowing hands free operation.
capabilities to all the functions of the 500S.

Features 500 500C 500S 500D


Single Frequency Capabilities P P P P
Digital Conductivity P P P
Coating Thickness Measurement P P P
Rotating Scanner Suport P P
Spilt Screen Display P P
Dual Frequency Capabilities P 920-079B-EN
Nortec 500, 500C, 500S and 500D Specifications*
Frequency Range: 50 Hz - 12 MHz General Conductivity
Gain: 0 - 90 dB in 0.1 dB steps. The hori- Dimensions: (Nortec 500C, 500S & Nortec 500D only)
zontal and vertical gains may be adjusted 8.5” L x 5.5” H x 2.4” D Frequency: 60 kHz or 480 kHz
separately or together. 216 mm x 140 mm x 61 mm Digital Conductivity Specification:
Rotation: Variable 0º - 359º in 1º steps Weight: 2.8 to 3.8 lbs. (1.2 to 1.7 kg), Digital conductivity display from 0.9% to
Sweep: Variable from 0.005 - 4 seconds per depending upon configuration 110% IACS or 0.5 to 64 MS/m. Accuracy
division Display: 5.25” x 3.9”, 6.5” diagonal within +/- 0.5% IACS from 0.9% to 65% IACS
Low Pass Filter: 10 - 500 Hz and wide band (133 mm x 99 mm, 165 mm) full VGA color and within +/- 1.0% of values over 62%.
High Pass Filter: Off or 2 to 500 Hz, 2 pole LCD (640 x 480 pixels) Meets or exceeds BAC 5651 specifications.
response Operating Temperature: Non-Conductive Coating Thickness: Can
Built-in Preamplifier: 5X (14 dB) additional 14º to 131º F (-10º to 55º C), measure non-conductive coating thickness
gain. depending on configuration from 0” to 0.015” (0 to 0.38 mm).
Probe Drive: 2, 6, 12 volts Storage Temperature: Accuracy of +/- 0.001” (0.025 mm) over 0.00
-60º to 160º F (-51º to 71º C), to 0.015” (0 to 0.38 mm) range
Variable Persistence: 0.1 - 5 seconds
depending on configuration
Probe Types: Absolute and differential in
Humidity: 5 to 95%
Scanners
either bridge or reflection configuration. The (Nortec 500S and Nortec 500D only)
instrument is fully compatible with Nortec Classification: Based on Class 2
Scanner Compatibility: Will operate all
PowerLink™ probes. specifications from the MIL-PRF-28800F
Nortec scanners and many other commer-
Alarms: Can be set to trigger on positive or handbook
cially available scanners
negative box, polar, or sweep alarm settings Altitude: Maximum operating and
Waterfall Display: 60 sweeps per hole and
Alarm Modes: 1-3 box gates, polar, sweep, non-operating altitude- 15,000 ft. (4600 m)
includes an on screen readout of the distance
conductivity, and coating thickness Hazardous Area Operation: Safe to the defect from the start of the scan (PS-5
Trace Storage: Up to 400 traces can be stored operation as defined by Class I, Division 2, only)
for recall. The traces can be static or frozen Group D, as found in the National Fire
and can contain up to 60 seconds of move- Association Code (NFPA 70), Section 500, Dual Frequency
ment. The traces are stored with the date and and tested using MIL-STD-810F, Method (Nortec 500D only)
time of capture. 511.4, Procedure 1 Frequency Extension: 50 Hz to 12 MHz
Program Storage: Up to 200 instrument set- Power Second Frequency: 25 Hz to 6 MHz, 2nd
ups may be stored and recalled. The date and Power Requirements: 85 to 240 volts, 50- frequency is an exact division of the first
time of storage is recorded with each set-up. 60 Hz. Battery can be charged within the frequency in ratios of: 1/2 (F1 < 6 MHz), 1/4,
Print Out: Provides a custom configurable instrument or in an external charger. Charge 1/8, 1/16, 1/32 .
report header containing the display screen typically takes 4 hours. Display: Frequency 1 (F1) only, Frequency 2
data and probe parameters including serial Available batteries: 2.4Ahr Li-Ion or 8.8Ahr (F2) only, sum of F1 and F2, difference
numbers (PowerLink™ probes only). Li-Ion between F1 and F2, split screen with
selected combinations of F1 and F2 and
Inputs / Outputs Low Battery Protection: Display bar graph
“gas gauge” indicates approximate operating
mixed frequencies
Power: 2-pin connector to charge the internal High Pass Filter: Available in Frequency (F1)
batteries and operate the instrument from AC time. A low battery annunciator indicates
when approximately 10 minutes of operation only
power
time is left.
USB Port: Allows interface with PC
and printers Battery Operating Time: 3 - 8 hours nominal
depending on configuration and scanner
Probe Connector: 16-pin LEMO and BNC
usage.
Analog Outputs: Horizontal and vertical
outputs of both F1 and F2. +/- 5 volts, 1 volt
per division (four outputs)
Alarm Outputs: 15-pin analog and alarm
output connector
VGA Output: 15-pin connector

www.olympusNDT.com
info@olympusNDT.com

Olympus NDT
48 Woerd Avenue • Waltham, MA 02453 • USA
Tel.: (1) 781-419-3900 • Fax: (1) 781-419-3980
12569 Gulf Freeway • Houston, TX 77034 • USA
Tel.: (1) 281-922-9300 • Fax: (1) 952-487-8877
Olympus NDT U.K. LTD.
12 Nightingale Close • Rotherham, South Yorkshire S60 2AB • UK
Olympus Singapore PTE. LTD.
491B River Valley Road 12-01/04, Valley Point Office Tower, 248373 • Singapore
Olympus Australia PTY. LTD.
PO Box 985 • Mount Waverley, VIC 3149 • Australia

Copyright © 2007 by Olympus NDT. All brands are trademarks or registered trademarks of their respective owners.
*All specifications are subject to change without notice.