@% VERTIV.
Liebert®
1S)
from 10 to 60 kw
Optimized and integrated three-phase
Seon ane icacy
Pec aeicrron)Pals} ae Co Ce AY
Liebert’ EXS from 10 to 60 kVA
Compact design and improved
performances
The new Liebert® EXS is
a monolithic transformer-free UPS
which brings exceptional features
for mission-critical applications. its
extraordinary double conversion
efficiency up to 96.2% ensures
remarkable operational cost
savings, reducing both the Total
Cost of Ownership (TCO) and the
environmental impact.
‘At the same time, with its unity
‘output power factor and high power
density, Liebert EXS is able to
provide the utmost active power
possible in a compact footprint. In
fact, its improved design reduces its
footprint to 8 minimum, providing
continuous power protection with
optimized internal runtime in
a standalone solution, making the
Liebert EXS perfect for both IT
installations and other mission
cr ppplications, such as
transportation, emergency lighting,
healthcare, retail and government
facilities.
a UNS)
eae WUE ota
+ Output power factor up to 1
+ Double conversion
efficiency up to 96.2%
+ ECO mode efficiency up to
99.3%
+ Compact footprint with
multiple internal runtime
configurations
+ Available in 3/3 and 3/1
versions (10-20 KVA)
+ Integrated maintenance:
bypass
+ Integrated input and output
breakers/switches
+ Parallel capability for
capacity and redundancy
+ Lithium-ion battery,
‘compatible
970%.
650%
96.00%
9550%
95,00%
94.50%
94.00%,
20%
— oh
40% 50% 60% 70% 80% 90% 100%
Liebert EXS 10-60 kVA efficiency curve
Energy
Ww Verified
CENTRAL POWER SUPPLY SYSTEM
(CPSs)
Liebert EXS can be used for CPSS applications* as
defined in the EN 50171 standard, and is hence
capable of supplying the necessary emergency
power to essential safety equipment. In fact, the
unit can be used to power emergency escape lighting
in case of normal supply failure and may also be
suitable for powering other safety systems such as
automatic fire extinguishing installations, signaling
safety installations and smoke extraction equipment.
* Subjact to additional prescriptions
RAILWAYS APPLICATIONS
Liebert EXS can be used for railways applications as
defined in the EN 50121 standard, and it's hence
capable of supplying power to specific systems in
urban stations and ensure high reliability to critical
buildings. In fact, the unit can be used to power on
passenger information panels, safety signaling
equipment, ticket machines as well as IT rooms and
administration and control offices.@% vertiv.
Flexibility
To ensure superior protection f
critical loads, the Liebert® EXS
range has been designed to
optimize specific rating
requirements, thus enhancing
flexibility ang installation spay
needs.
iebert EXS's flexibility is further
enhanced through:
+ Single and three phase output
configurations up to 20 kVA
+ Integrated parallel capability up
to 4 units
+ Common or distributed battery
bank
+ Internal and external battery
ations for optimized
Up time management
sters for easy UP:
repositioning
Output Configuration
Liebert EXS models up to 20 kVA
can be configured on-site to deliver
three (3/3) or single 3/1) phase
output giving it the flexibility to
adapt to changes in installation
environments,
READY FOR
rent)
Integrated Autonomy
Liebert EXS provides an optimized
tegrated autonomy which
ults in back up times in a
compact footprint
its intemal architecture is able to
house up to four battery strings,
‘urther optimizing integrated
autonomy and delivering the
added advantage of virtually
eliminating the need for an external
battery cabinet
This furthermore reduces
installation costs and minimizes
the demand on physical Ine
addition, Liebert EXS's powerful
battery charger ensures rapid
recharge, increasing its ability to
manage longer back up times.
ery stings
1600]
Full Galvanic Isolation
fers integrated full
ng that an
isolation transformer may be
housed inside the UPS cabinet.
This greatly reduces the system
nus providing space
roviding
ill galvanic isolation fo
medical and other critical
applic
installation with two
independent input sources (with
different neutrals)
installation in distribution
without neutral
x8 604A wth uot four
atogrted bate sngLIEBERT’ EXS from 10 to 60 kVA.
In The Field
Parallel Ready
Liebert EXS Automatic AC Bypass
ware settings, a
sstem to be customized for
anfiguration. The
nection used in
Intelligent Paralleling Feature
Activating the Intelligent Paralle
ficiency at partial
omatically adapt c
meet immediate load ri
by switching excess units to
standby mode, while ensuring
operate in
standby mot same
amount of time, ensuring an equal
life span of module components.Communication
t? EXS features a multi
LCD user interfa
| and m
These communi
make Liebert EX:
with any building management
system.
Software Connectivity
iv™ shutdown software
power losses and initiating sa
shutdown of operating systems if
required, Vertiv Nform™ network
munications system enables
customers to leverage the
distributed monitoring ca
lites
providing centralized mar
of distributed systems,
VERTIV™ TRELLIS™
Vertiv Trelis platform is a rea
time infrastructure optimization
platform
Unified manag}
center IT and faclities
infrastructure
The V
software
track inver
visualize con
and calculate energy usage, and
optimize cooling and power
equipment as well as enable for
virtualization
The Ver
ities orga
nter running at peak
formance. This unified and
mplete solution, delivers the
ower to see the real situation
data center, make the
n and take action
Serviceability
re of the Lie!
optimize inst
and simplify service with its
vable power assembly
tecture considerably
EXS
lation
sily
serviceability, Liebert EXS
comes equipped with caste
eloLIEBERT* EXS from 10 to 60 kVA
VERTIV™ LIFE™ Services Remote Diagnostic and Preventive Monitoring
Vertiv's service program is,
designed to ensure that your
critical power protection system is
maintained in an optimum state of
readiness at all times,
‘The Vertiv LIFE™ Services remote
diagnostic and preventive
monitoring service provides early
warning of UPS conditions and out
of tolerances. This allows ¢ ective
proactive maintenance, fast
incident response and remote
troubleshooting, giving customers
complete security and peace of
mind. With Vertiv LIFE Services
you will benefit from:
Uptime Assurance
Constant monitoring of UPS
parameters, thus maximizing the
system's availability.
First Time Fix Rate
Pro-active monitoring and data
‘measuring ensure that when our
customer engineers are
dispatched on-site, they arrive
prepared for first time resolution,
Proactive Analysis
From Vertiv LIFE Service centers,
our experts proactively analyze the
data and trends of your equipment,
to recommend actions to ensure
their best performance,
Minimized Total Cost of
Ownership of Your Equipment
The continuous monitoring of all
relevant parameters in turn
maximizes unit performance,
reduces on-site maintenance and
extends the life of your equipment,
Fast Incident Response
Vertiv LIFE Services allow for
immediate definition of the best
course of action, as a result of the
regular communication between
your Liebert APM system and our
Vertiv LIFE Service centers
Reporting
You will eceive a comprehensive
report detailing the working order
of your equipment and its
‘operational performance,Liebert® EXS Specifications
fu
Nominal input vege
ONCOHIS Chea: phase +N + PED
Honan sore
vt eure sown
oto fact ed ce) owe
core Hen THOR ae
Pe const
ET
Voltage temperature compensation (m¥CiCeld
BBO/4OO)S Ghvee-phase » N PE) or720/230/240
ge phasa SN SBS sKOOILI Aves phase + N+ PE)
Nominal output voltage 6)
Nominal output equeney ie) 0/60
Maru active pomec CN) ” ® 2 30 40 0
“TDW at fulinear load C0 2
nvr nln e2oneny 0% fr GO mK Sin SOR me EOKtor TOR" mn SR OMe SOR rm OR
CO made eticency C3)" Uptosesx
335x650 100 (andar version) 00250
Dimensions xD xt Rm 40x 0 x1800 ase
Net weight Gxcading baton) ko esteanced verson)
(GENERAL
Noise atm Ce8A9
Maximum ane 15007 without dering rx 9000 0)
Operating Temperturecc) 1950" voteso
Protection el 00529) vr20
ner ans sey roqureronts for UPS EMC EN/ECiAs 020401
recuiroent fo UPS ENMECIAS 620402
UPS classifesion scoring toIECENG2040-3 vss.
“condone soo@% VERTIV.