You are on page 1of 82

PRODUCT DATASHEET

www.high-accuracy.com
Product Data Sheet
April 2017
00813-0200-4952, Rev DB

Rosemount™ 114C Thermowells

 Wide variety of industry standard process connections including flanged, threaded, welded, and Van
Stone.

 Large selection of thermowell materials to ensure proper process compatibility from stainless steel to
exotic materials such as duplex and alloy C-276.

 Additional thermowell options and certificates available.


Rosemount 114C April 2017

Contents
Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Rosemount 114C Van Stone Thermowells . . . . . . . . . . .31
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Van Stone thermowell overview . . . . . . . . . . . . . . . . .32
Rosemount 114C Threaded Thermowells . . . . . . . . . . . . 6 Van Stone ordering information . . . . . . . . . . . . . . . . .34
Threaded thermowell overview . . . . . . . . . . . . . . . . . . . 7 Van Stone thermowell drawings . . . . . . . . . . . . . . . . .41
Threaded ordering information . . . . . . . . . . . . . . . . . . . 7 Rosemount 114C Welded Thermowells . . . . . . . . . . . . .43
Threaded thermowell drawings . . . . . . . . . . . . . . . . . . 15 Welded thermowell overview . . . . . . . . . . . . . . . . . . .44
Rosemount 114C Flanged Thermowells . . . . . . . . . . . . 17 Welded ordering information . . . . . . . . . . . . . . . . . . .46
Flanged thermowell overview . . . . . . . . . . . . . . . . . . . 18 Weld-in Type 4 thermowells according to DIN 43772 .51
Flanged ordering information . . . . . . . . . . . . . . . . . . . 20 Welded thermowell drawings . . . . . . . . . . . . . . . . . . .54
Flanged thermowell drawings . . . . . . . . . . . . . . . . . . . 28 Ordering information detail . . . . . . . . . . . . . . . . . . . . . . .56

2 Emerson.com/Rosemount
April 2017 Rosemount 114C

Rosemount 114C Thermowell


Product overview
Temperature sensors are rarely inserted directly into an industrial process. They are installed into a thermowell to isolate them from the
potentially damaging process conditions of flow-induced stresses, high pressure, and corrosive chemical effects. Thermowells are
closed-end metal tubes or barstock installed into the process vessel or piping and become an integral pressure-tight part of the process
vessel or pipe. They permit the sensor to be quickly and easily removed from the process for calibration or replacement without requiring
a process shutdown and possible drainage of the pipe or vessel.
The Rosemount 114C Thermowell is made from solid barstock to ensure strength and integrity. The Rosemount 114C was designed to
accommodate a host of industry standard configurations, but has the flexibility to adapt to special configurations for different types of
applications.

Flexible design modifiers accommodate many process requirements


 Different sizes of root (A), tip (B), and bore (d) diameters
 Different tip (t) thickness as required
A B d
 Numerous combinations for various industrial applications
 Meet ASME PTC 19.3 TW-2016 standard with flexible design
t

Thermowell calculations ensure thermowell design


is compatible with process conditions
 Thermowells inserted into any process are subjected to forces
Figure 1. Thermowell Calculation Report (R21)
from the fluid flow.
 ASME released design standard PTC 19.3 TW that defines a
series of qualitative calculations to determine design suitability
to withstand process conditions.
 Calculations are based on process conditions, process fluid,
installation method, thermowell geometry and material.
 The thermowell calculation tool from Emerson™ is designed to
meet the ASME standard.
 The free online software version can be used for preliminary
calculations. Click here to access the tool.
 Formal calculations by our expert team of engineers are
available prior to order placement to ensure design is
acceptable.
 Recommendations are also made if thermowell design is found
to be unacceptable for the application.
 Order Thermowell Calculation option (R21) to receive a formal
report with product shipment.

Emerson.com/Rosemount 3
Rosemount 114C April 2017

Wide range of thermowell options and certificates for any application


 Options for special testing requirements, such as External Hydrostatic Pressure Test (Q5) and Dye Penetration Test (Q73)
 Options to ensure material traceability or compatibility, including Positive Material Identification or PMI (Q76), Material
Certification (Q8), Thermowell X-ray/Radiograph (Q81), and NACE® Approval (Q35)
 Options for special processing requirements such as Electropolishing (R20)

Experience global consistency and local support from numerous worldwide


Emerson manufacturing sites
 World-class manufacturing provides globally consistent product
from every factory and the capacity to fulfill the needs of any
project, large or small.
 Experienced Instrumentation Consultants help select the right
product for any temperature application and offer advice on best
installation practices.
 An extensive global network of Emerson service and support
personnel can be on-site when and where they are needed.

Explore the benefits of a Complete Point Solution™ from Emerson


 An “Assemble Sensor to Specific Transmitter” and “Assemble Sensor to Specific Thermowell” option enables Emerson to provide a
Complete Point Solution for measuring temperature, delivering an installation-ready transmitter, sensor, and thermowell
assembly.
 Emerson has a complete portfolio of Single Point and Multi-Input Temperature Measurement solutions, allowing effective
measurement and process control with reliable Rosemount products.

4 Emerson.com/Rosemount
April 2017 Rosemount 114C

Selection guide
Ensure sensor fits thermowell
Rosemount 114C Head length (H) + Immersion length (U) = Rosemount 214C Sensor insertion length (L).
H U

Basic selection guide


Selecting the proper thermowell for an application is an important activity as it impacts plant safety and measurement efficiency.
Thermowells are considered a wetted part; they physically become part of the pressure retaining system.
The four major factors to consider when selecting a thermowell for an application are described below:

Thermowell length
There is no standard formula to determine thermowell immersion length. However, there are a few common practices that the
process industry follows along with good engineering judgment. Ideally the thermowell tip should be located near the centerline in
turbulent flow conditions because this represents the most accurate process temperature.
To ensure optimal performance, a general guideline for immersion length into a pipe is as follows:
 10⫻ the thermowell root diameter for air or gas
 5⫻ the thermowell root diameter for liquids

Another guideline is at least one-third the way into the pipe for any measurement. The American Petroleum Institute (API) has a
specific recommendation of using an immersion length of the sensing element plus 50 mm (2-in.).

Mounting configuration
Consider how the thermowell is mounted on the pipe or tank. The process designer typically specifies what mating connection will
be used and the thermowell selected should match that connection. Temperature, pressure, and material are usually taken into
consideration to ensure the process connection will be adequate for the application. Welded, threaded, flanged, and Van Stone are
standard mounting configuration options.

Thermowell stem profile


Factors to be considered when selecting a stem style include the process pressure, required response speed of the measurement,
drag force of the fluid flow on the well, and the wake frequency. The stem or shank is the part of a thermowell inserted into the
process piping or vessel. Straight, stepped and tapered stem styles are available. Each profile has its advantages depending on the
need and situation.

Thermowell material
Rosemount Thermowells are supplied in most materials required for industrial applications. Standard materials are 316/316L
Stainless Steel, 304/304L Stainless Steel, and A105 Carbon Steel. For corrosive environments, special materials such as Alloy C-276
and Alloy 600 are also available. See the ordering table for a complete listing of standard materials. Contact your local Emerson
representative for additional material availability.

Emerson.com/Rosemount 5
Rosemount 114C April 2017

Rosemount 114C Threaded Thermowells

6 Emerson.com/Rosemount
April 2017 Rosemount 114C

Threaded thermowell overview


Threaded thermowells are threaded into a process pipe or tank, allowing for easy installation and removal when necessary. While this
is a common mounting method, it has the lowest pressure rating of all mounting configuration options.

Figure 2. Standard Offering–Threaded


Model Units Immersion Mounting Process Stem Thermowell Head Instrument Options
length (U) style connection style material length (H) connection threads
1 1 4 C X X X X X T X X X X X X X X X XX, XXX, XX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

(16-18) Head length (H) Common options

(5) Units (10) Mounting style (13) Stem style XXX 1.75- to 11.25-in. (E) Q5 External pressure test
Example: 1.75.in = 017, Q35 NACE approval
English (E) Threaded (T) 1 Straight stem 10-in. = 100
R21 Thermowell
Metric (M) 2 Tapered stem XXX 40 to 225mm (M) calculation
Example: 40 mm = 040,
3 Stepped stem 225 mm =225 Q8 Material certification
(6-9) Immersion length (U)
XXXX 1- to 42-in. (E) (11-12) Process connections (14-15) Thermowell material (19) Instrument connection
Example: 2-in. = 0020,
42-in. =0420 AA ½-14 NPT SC 316/316L SST A ½-14 NPT
XXXX 25 to 1165 mm (M) AB ¾-14 NPT SF 304/304L SST B ½-14 NPSM
Example: 25 mm = 0025,
AC 1-11.5 NPT CS Carbon steel D M18 x 1.5p
1165 mm =1165
DA M20 x 1.5p E M20 x 1.5p
DB M24 x 1.5p F M24 x 1.5p
DE ½-in. BSPF (G½)

The common options shown in Figure 2 represent a partial offering; reference the Rosemount 114C Threaded Ordering Information
for a full list of available options.

Figure 3. Threaded Thermowell Components


Tapered threads Parallel threads

H U H U

A A
B B

A. Instrument connection H. Head length


B. Process connection U. Immersion length

Note
Wetted surface includes engaged threads and immersion length (U).

Emerson.com/Rosemount 7
Rosemount 114C April 2017

Use the form below to record your model code:


Immersion Mounting Process Stem Thermowell Instrument
Model Units Head length (H) Options
length (U) style connection style material connection

1 1 4 C T
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 XXXXX

8 Emerson.com/Rosemount
April 2017 Rosemount 114C

Threaded ordering information


Figure 4. Model Number Ordering Example
Immersion Mounting Process Stem Thermowell Instrument
Model Units Head length (H) Options
length (U) style connection style material connection

WR5,
1 1 4 C E 0 0 6 0 T A A 1 S C 0 5 0 A
Q76...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 XXXXX

The numbers below the model number ordering example correlate to the character place numbers in the second column of the
ordering table.
Table 1. Rosemount 114C Threaded Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.

Place #s Ref.
Model Details
1-4 page
Barstock temperature Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip wall
★ 114C N/A
thermowell thickness of 0.25-in. (6.4 mm)

Place #
Dimension units
5
★ E English units (inches) 56
Specifies whether length units will be in inches (in) or millimeters (mm)
★ M Metric units (mm) 56

Tapered threads Parallel threads

Place #s U U

Immersion length (U)


6-9

xxx.x-in., 1.00 to 100 inches in 1/4-in. increments (when ordered with dimension units code E)
★ xxxx 56
Example of a 6.25-in. length where the second decimal is dropped off: 0062

xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
★ xxxx 56
Example of a 50 mm length: 0050

Place #
Mounting style
10
★ T Threaded N/A

Place #s
Process connection
11-12
★ AA / –14 NPT
1 2 Tapered threads N/A
★ AB / –14 NPT
3 4 Tapered threads N/A
★ AC 1–11.5 NPT Tapered threads N/A
★ AD 11/2–11.5 NPT Tapered threads N/A
★ AE / -in. BSPT
1 2 Tapered threads N/A

Emerson.com/Rosemount 9
Rosemount 114C April 2017

Table 1. Rosemount 114C Threaded Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.

★ AF / -in. BSPT
3 4 Tapered threads N/A
★ AG 1-in. BSPT Tapered threads N/A
★ DA M20 ⫻ 1.5p Parallel threads N/A
★ DB M24 ⫻ 1.5p Parallel threads N/A
★ DC M27 ⫻ 2p Parallel threads N/A

DD M33 ⫻ 2p Parallel threads N/A


★ DE / -in. BSPF (G1/2)
1 2 Parallel threads N/A
★ DF / -in. BSPF (G3/4)
3 4 Parallel threads N/A
★ DG 1-in. BSPF (G1) Parallel threads N/A

Place # Ref.
Stem style Details Image
13 page
Minimum immersion length
★ 1 Straight 1-in. (25 mm) - Tapered threads 57
1.75-in. (45 mm) - Parallel threads
Minimum immersion length
★ 2 Tapered 1-in. (25 mm) - Tapered threads 57
1.75-in. (45 mm) - Parallel threads
Minimum immersion length
★ 3 Stepped 3-in. (75 mm) - Tapered threads 57
3.75-in. (95 mm) - Parallel threads

Place #s
Thermowell material Details
14-15
★ SC 316/316L dual rated 58

SD 316/316L dual rated (NORSOK) Must order the Q8 Material Certificate to get NORSOK documentation 59
★ SF 304/304L dual rated 58
★ CS Carbon steel (A-105) 58
SG 316Ti SST 58

SL 310 SST 58

SM 321 SST 58

AB Alloy B3 58

AC Alloy C-276 58

AG Alloy 20 59

AH Alloy 400 58

AK Alloy 600 58

MO Molybdenum 58
Chrome-Moly Grade B-11/F-11
CA 58
Class II

10 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 1. Rosemount 114C Threaded Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.

Chrome-Moly Grade B-22/ F-22


CB 58
Class III
CC Chrome-Moly Grade F-91 58

NK Nickel 200 58

TT Titanium Grade 2 58

DS Super duplex SST Grade F-53 58


Super duplex SST Grade F-53 –
DT Must order the Q8 Material Certificate to get NORSOK documentation 59
NORSOK
DU Duplex 2205 Grade F51 58
Duplex 2205 Grade F51 –
DV Must order the Q8 Material Certificate to get NORSOK documentation 59
NORSOK

Tapered threads Parallel threads


Place # H H Ref.
Head length (H)
16-18 page

xx.x-in., 1.75 to 11.25 inches in 1/4-in. increments (when ordered with dimension units code E)
★ xxx 60
Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 1.75-in.)

xxx mm, 40 to 225 mm in 5 mm increments (when ordered with dimension units code M)
★ xxx 60
Example of a 50 mm length: 050 (default head length = 45 mm)

Place #
Instrument connection Details Image
19
★ A / –14 NPT
1 2 61
★ B / –14 NPSM
1 2 61
C / –14 NPT
3 4 61

D M18 ⫻ 1.5p 61
E M20 ⫻ 1.5p 61
Female threads
F M24 ⫻ 1.5p 61

G G 1/2-in. (BSPF) 61

H G 3/4-in. (BSPF) 61

J M27 ⫻ 2p 61

K M14 ⫻ 1.5p 61

Emerson.com/Rosemount 11
Rosemount 114C April 2017

Table 1. Rosemount 114C Threaded Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.

Options (include with selected model number)


Sensor/thermowell assemble to Ref.
Details
options page
Hand tight assembly of sensor
★ XT Ensures sensor is threaded into thermowell but only hand tightened 62
and thermowell
Process-ready assembly of Ensures sensor is threaded into thermowell and torqued for process-ready
★ XW 62
sensor and thermowell installation

Extended product warranty


★ WR3 3-year limited warranty This warranty option extends manufacturer’s warranty to three or five years 62
★ WR5 5-year limited warranty for manufacturer related defects 62

Thermowell calculation
★ R21 Thermowell calculation Set of calculations to ensure thermowells are safe in certain process conditions 63

NACE approval
★ Q35 NACE approval Meets MR0175/ISO 15156 and MR0103 requirements 63

PMI testing
Q76 PMI testing Verifies chemical composition of material 64

Material certification
Certificate for material conformance and traceability in accordance with EN
★ Q8 Material certification 64
10204 type 3.1

Material tests
M01 Low temperature Charpy Test Measures the low temperature ductility of the material 64
M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 65

Surface finish
Q16 Certification Certificate showing measured surface finish values 65

R14 Finish < Ra 0.3 μm (12 μin) Improves surface roughness of thermowell 65

Electropolish
R20 Electropolish Improve smoothness and surface quality 65

Hydrostatic pressure test


Verifies structural quality and checks for leaks at thermowell process
★ Q5 External pressure test 66
connection and stem
★ Q85 Internal pressure test Verifies internal structural integrity of thermowell 66

Canadian Registration Number


Q17 Canadian Registration Number Canadian approvals for all provinces (Approved materials in reference section) 67

12 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 1. Rosemount 114C Threaded Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.

Ref.
Dye penetration test Details
page
★ Q73 Dye penetration test Checks quality of material 67

Wall thickness test


Q83 Ultrasonic test Checks the bore concentricity of the thermowell 68

Special cleaning
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 68

Thermowell markings
External marking of the thermowell for specific tests (see reference page for
R40 Test markings on thermowell 68
list of tests)

Spherical tip
R60 Spherical tip Changes the flat tip to spherical 69

Vent hole
Allows for the venting of a thermowell and for indication that thermowell
R11 Vent hole 70
structural integrity has been compromised

Thermowells with wrench flats


Converts the two wrench flats to hex wrench flats; only applies to exotic
R37 Thermowells with wrench flats 75
materials

A
Root diameter (A)

x.xx-in., 0.36 to 3.15 inches in 0.01-in. increments (when ordered with dimension units code E)
Axxx 76
Examples: Code A040 = 0.4-in., Code A315 = 3.15-in.
xx.xx mm, 10 to 80 mm in 0.5 mm increments (when ordered with dimension units code M)
Axxx 76
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm

B
Tip diameter (B)

x.xx-in., 0.36 to 1.83 inches in 0.01-in. increments (when ordered with dimension units code E)
Bxxx 77
Examples: Code B040 = 0.4-in., Code B180 = 1.80-in.

xx.xx mm, 10 to 46 mm in 0.5-mm. increments (when ordered with dimension units code M)
Bxxx 77
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm

Emerson.com/Rosemount 13
Rosemount 114C April 2017

Table 1. Rosemount 114C Threaded Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.

Ref.
Non-standard bore diameter (d) Details Image
page
D01 0.276-in./7.0 mm 78
d
D03 0.138-in./3.5 mm 78

D04 0.386- in./9.8 mm Default = 0.26-in. (6.5 mm) 78

D05 0.354-in./9.0 mm 78

D06 0.433-in./11.0 mm 78

Non-standard tip thickness (t)


T01 0.197-in./5.0 mm 78

Default = 0.25-in. (6.4 mm)


T02 0.236-in./6.0 mm 78
t

Threaded installation
Threaded thermowells are screwed into the process using a threaded fitting or directly into a tapped pipe if there is sufficient wall
thickness. Tapered threads will deform to each other to create a seal. Thread sealant and appropriate torque should be applied to
reduce risk of leaks.

Figure 5. Installation Components


A

B
C C

A. Thermowell
B. Threaded fitting
C. Weld
D. Process

14 Emerson.com/Rosemount
April 2017 Rosemount 114C

Threaded thermowell drawings


Figure 6. Thread Mount Thermowell Drawings (Tapered Thread)(1)
Straight Tapered Stepped

E N

.75 (19)

A
A

2.5 (63.5)

B B B

A. Root diameter N. Instrument connection


B. Tip diameter P. Process connection
C. Total length (U + H) U. Immersion length
E. Wrench allowance d. Bore diameter
F. Thread allowance t. Tip thickness
H. Head length

Table 2. Thread Mount Thermowells (Tapered Thread)(1)


Code T, threaded
Wrench flat size “G”
mounting style Root diameter Root diameter Tip diameter Root diameter Thread
Code
Process Metric units English units stepped stem tapered stem tapered stem straight stem specification
connection “P” (code M) (code E)
AA 1/2–14 NPT 1.18 (30) 11/8 (28.6) 0.67 (17) 0.67 (17) 0.50 (12.7) 0.669 (17)
AB 3/4–14 NPT 1.18 (30) 11/8 (28.6) 0.75 (19) 0.89 (22.5) 0.63 (16) 0.71 (18) NPT per SAE -AS
71051
AC 1–11.5 NPT 1.34 (34) 11/4 (31.8) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18) (reference PS-71)
AD 11/2–11.5 NPT 1.89 (48) 13/4 (44.5) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18)
AE 1/2-in. BSPT 1.18 (30) 11/8 (28.6) 0.67 (17) 0.67 (17) 0.50 (12.7) 0.669 (17)
3/4-in. BSPT THD per ISO 7/1 (BS
AF 1.18 (30) 11/8 (28.6) 0.75 (19) 0.89 (22.5) 0.63 (16) 0.71 (18)
21)
AG 1-in. BSPT 1.34 (34) 11/4 (31.8) 0.85 (21.5) 1.04 (26.5) 0.71 (18) 0.71 (18)

1. Dimensions are in inches (millimeters).

1. Total length = U+ H.

Emerson.com/Rosemount 15
Rosemount 114C April 2017

Figure 7. Thread Mount Thermowell Drawings (Parallel Thread)(1)


Straight Tapered Stepped
N

A A

C U
F

2.50 [63,5]
STEP LENGTH

B B B

A. Root diameter N. Instrument connection


B. Tip diameter P. Process connection
C. Total length (U + H) U. Immersion length
F. Hex size d. Bore diameter
H. Head length t. Tip thickness

Table 3. Thread Mount Thermowells (Parallel Thread)(1)


Code T, threaded mounting Tip diameter tapered
style Root diameter Root diameter Thread
Code Hex size “F” stem and straight
stepped stem tapered stem specification
Process connection “P” stem

DA M20 ⫻ 1.5 1.18 (30) 0.67 (17) 0.67 (17) 0.5 (12.7)
DB M24 ⫻ 1.5 1.18 (30) 0.75 (19) 0.75 (19) 0.5 (12.7)
Thread per BS3643
DC M27 ⫻ 2 1.26 or 1.42 (32 or 36) 0.75 (19) 0.75 (19) 0.5 (12.7)
DD M33 ⫻ 2 1.61 (41) 0.85 (21.5) 1.04 (26.5) 0.71 (18)
DE 1/2-in. BSPF (G1/2) 1.06 (27) 0.67 (17) 0.67 (17) 0.5 (12.7)
3/4-in. BSPF (G3/4) Thread per ISO 228/1
DF 1.26 (32) 0.75 (19) 0.75 (19) 0.5 (12.7)
(BS 2779)
DG 1-in. BSPF (G1) 1.61 (41) 0.85 (21.5) 1.04 (26.5) 0.71 (18)

1. Dimensions are in inches (millimeters).

Note
Hex size will be different depending on units selected (english and metric).
Wrench flats are used on exotic materials instead of hex flats. For hex flats on exotic materials, select option R37.
Additional root and tip diameters available.

1. Total length = U+ H.

16 Emerson.com/Rosemount
April 2017 Rosemount 114C

Rosemount 114C Flanged Thermowells

Emerson.com/Rosemount 17
Rosemount 114C April 2017

Flanged thermowell overview


All Rosemount flanged thermowells are manufactured in accordance with ANSI B16.5. The flange to stem weld is in accordance to
ASME Section IX. There is also full traceability with material certifications available on request. Rosemount flanged thermowells are
available in two manufacturing configurations: full and partial penetration welds.
Full penetration weld (F) Partial penetration weld (P) Forged, no welds (G)
 Stronger weld  Adequate for  Highest fatigue
joint per ASME most process resistance per
PTC 19.3 applications ASME PTC 19.3
TW-2016  Weld withstands TW 2016
 Used for heavy same pressure  Eliminates weld
duty applications and temperature rating as flange qualifications and failures
 Emerson recommended option  Lower cost than full penetration weld  Used in extreme process applications

Figure 8. Standard Offering–Flanged


Model Units Immersion Mounting Process Stem Thermowell Head Instrument Options
length (U) style connection style material length (H) connection threads
1 1 4 C X X X X X X X X X X X X X X X XX, XXX, XX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Common options
(16-18) Head length (H)
Q5 External pressure test
(10) Mounting style
(5) Units (13) Stem style XXX 2.25- to 11.25-in. (E) Q35 NACE approval
F Full penetration weld Example: 2.25-in. = 022,
English (E) R21 Thermowell
1 Straight stem 10-in. = 100
calculation
P Partial penetration
Metric (M) weld 2 Tapered stem XXX 40 to 225 mm (M)
Example: 40 mm = 040, Q8 Material certification
G Forged, no welds 3 Stepped stem 225 mm = 225 Q73 Dye penetration test
(6-9) Immersion length (U)
XXXX 0.5- to 42-in. (E) (11-12) Process connections (14-15) Thermowell material (19) Instrument connection
Example: 0.5-in. = 0005,
42-in.= 0420 AA 1-in. Class 150 SC 316/316L SST A ½-14 NPT
XXXX 25 to 1165 mm (M) AB 1½-in. Class 150 SF 304/304L SST B ½-14 NPSM
Example: 25 mm = 0025, D M18 x 1.5p
1165 mm = 1165 AC 2-in. Class 150 CS Carbon steel
E M20 x 1.5p
AH 1-in. Class 300
AJ 1½-in. Class 300 F M24 x 1.5p

AK 2-in. Class 300

The common options shown in Figure 8 represent a partial offering; reference the Rosemount 114C Flanged Ordering Information
for a full list of available options.
Figure 9. Flanged Thermowell Components
H U

A. Instrument connection H. Head length


B. Process connection U. Immersion length

Note
Wetted surface includes flange face and immersion length (U).

18 Emerson.com/Rosemount
April 2017 Rosemount 114C

Use the form below to record your model code:


Immersion Mounting Process Stem Thermowell Instrument
Model Units Head length (H) Options
length (U) style connection style material connection

1 1 4 C
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 XXXXX

Emerson.com/Rosemount 19
Rosemount 114C April 2017

Flanged ordering information


Figure 10. Model Number Ordering Example
Immersion Mounting Process Stem Thermowell Instrument
Model Units Head length (H) Options
length (U) style connection style material connection

WR5,
1 1 4 C E 0 1 5 0 F A C 1 S C 0 5 0 A
Q76...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 XXXXX

The numbers below the model number ordering example correlate to the character place numbers in the second column of the
ordering table.

Table 4. Rosemount 114C Flanged Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Place #s Ref.
Model Details
1-4 page
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip
wall thickness of 0.25-in. (6.4 mm).
★ 114C Barstock temperature thermowell N/A
Default ASME flange facing is raised face with spiral serrations.
Default EN 1092-1 flange facing is raised face Type B1.
Place #
Dimension units
5
★ E English units (inches) Specifies whether length units will be in inches (in) or 56
★ M Metric units (mm) millimeters (mm) 56

Place #
Immersion length (U)
6-9

xx.x-in., 1 to 100 inches in 1/4-in. increments (when ordered with dimension units code E)
★ xxxx 56
Example of a 6.25-in. length where the second decimal is dropped off: 0062

xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
★ xxxx 56
Example of a 25 mm length: 0025
Place #
Mounting style
10
★ P Flange, partial penetration weld N/A
Weld refers to welding of the flange to thermowell stem
★ F Flange, full penetration weld N/A

G Flange, forged Single piece T-shaped forging, no welds N/A

20 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 4. Rosemount 114C Flanged Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Place #s Ref.
Process connection Details
11-12 page
Partial weld (P) Full penetration weld (F) Forged, no welds (G)
★ AA 1-in. Class 150 1-in. Class 150 1-in. Class 150 N/A
★ AB 11/2-in. Class 150 11/2-in. Class 150 11/2-in. Class 150 N/A
★ AC 2-in. Class 150 2-in. Class 150 2-in. Class 150 N/A
★ AD 3-in. Class 150 3-in. Class 150 3-in. Class 150 N/A
★ AE 4-in. Class 150 4-in. Class 150 4-in. Class 150 N/A
★ AF 6-in. Class 150 6-in. Class 150 6-in. Class 150 N/A
★ AG / -in. Class 300
3 4 / -in. Class 300
3 4 / -in. Class 300
3 4 N/A
★ AH 1-in. Class 300 1-in. Class 300 1-in. Class 300 N/A
★ AJ 11/2-in. Class 300 11/2-in. Class 300 11/2-in. Class 300 N/A
★ AK 2-in. Class 300 2-in. Class 300 2-in. Class 300 N/A

AL 1-in. Class 400/600 1-in. Class 400/600 1-in. Class 400/600 N/A

AM 11/2-in. Class 400/600 11/2-in. Class 400/600 11/2-in. Class 400/600 N/A

AN 2-in. Class 400/600 2-in. Class 400/600 N/A N/A

AP N/A 1-in. Class 900/1500 N/A N/A

AQ N/A 11/2-in. Class 900/1500 N/A N/A

AR N/A 2-in. Class 900/1500 N/A N/A

AT N/A 11/2-in. Class 2500 N/A N/A

AU N/A 2-in. Class 2500 N/A N/A

AV 3-in. Class 300 3-in. Class 300 N/A N/A


FA DN 20/PN 2.5/6 DN 20/PN 2.5/6 N/A N/A

FE DN 20/PN 10/16/25/40 DN 20/PN 10/16/25/40 N/A N/A

FG DN 20/PN 63/100 DN 20/PN 63/100 N/A N/A

GA DN 25/PN 2.5/6 DN 25/PN 2.5/6 N/A N/A

GE DN 25/PN 10/16/25/40 DN 25/PN 10/16/25/40 N/A N/A

GG DN 25 PN 63/100 DN 25/PN 63/100 N/A N/A

JA DN 40/PN 2.5/6 DN 40/PN 2.5/6 N/A N/A

JE DN 40/PN 10/16/25/40 DN 40/PN 10/16/25/40 N/A N/A

JG DN 40/PN 63/100 DN 40/PN 63/100 N/A N/A

KA DN 50/PN 2.5/6 DN 50/PN 2.5/6 N/A N/A

KC DN 50/PN 10/16 DN 50/PN 10/16 N/A N/A

KE DN 50/PN 25/40 DN 50/PN 25/40 N/A N/A

KF DN 50/PN 63 DN 50/PN 63 N/A N/A

Emerson.com/Rosemount 21
Rosemount 114C April 2017

Table 4. Rosemount 114C Flanged Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Place #s Ref.
Process connection Details
11-12 page
Partial weld (P) Full penetration weld (F) Forged, no welds (G)

KG DN 50/PN 100 DN 50/PN 100 N/A N/A

LA DN 65/PN 2.5/6 DN 65/PN 2.5/6 N/A N/A

LC DN 65/PN 10/16 DN 65/PN 10/16 N/A N/A

LE DN 65/PN 24/40 DN 65/PN 24/40 N/A N/A

LF DN 65/PN 63 DN 65/PN 63 N/A N/A

LG DN 65/PN 100 DN 65/PN 100 N/A N/A

MA DN 80/PN 2.5/6 DN 80/PN 2.5/6 N/A N/A

MC DN 80/PN 10/16 DN 80/PN 10/16 N/A N/A

ME DN 80/PN 25/40 DN 80/PN 25/40 N/A N/A

MF DN 80/PN 63 DN 80/PN 63 N/A N/A

MG DN 80/PN 100 DN 80/PN 100 N/A N/A

NA DN 100/PN 2.5/6 DN 100/PN 2.5/6 N/A N/A

NC DN 100/PN 10/16 DN 100/PN 10/16 N/A N/A

NE DN 100/PN 25/40 DN 100/PN 25/40 N/A N/A

NF DN 100/PN 63 DN 100/PN 63 N/A N/A

NG DN 100/PN 100 DN 100/PN 100 N/A N/A


Place #
Stem style Details Image
13

Minimum immersion length


★ 1 Straight 57
= 1-in. (25 mm)

Minimum immersion length


★ 2 Tapered 57
= 1-in. (25 mm)

Minimum immersion length


★ 3 Stepped 57
= 3-in. (75 mm)

22 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 4. Rosemount 114C Flanged Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Place #s Ref.
Thermowell material Details
14-15 page
★ SC 316/316L dual rated 58
Must order the Q8 Material Certificate to get NORSOK
SD 316/316L dual rated (NORSOK) 59
documentation
★ SF 304/304L dual rated 58
★ CS Carbon steel (A-105) 58

SG 316Ti SST 58
Only available as a straight stem profile with a 0.75 diameter thus
SH 316/316L SST with tantalum sheath 59
requires option A075 for English units
SJ 316/316L SST with PFA coating 58

SK 304/304L SST with PTFE coating 58

SL 310 SST 58

SM 321 SST 58

AB Alloy B3 58

AC Alloy C-276 58

AD Alloy C-4 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 58

AE Alloy C-22 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 58

AF Alloy C-22 (with 316/316L SST flange) Not available with G (Fully forged) mounting style 58

AG Alloy 20 58

AH Alloy 400 58

AJ Alloy 400 (with 304/304L SST flange) Not available with G (Fully forged) mounting style 58
AK Alloy 600 58

AL Alloy 600 (with 304/304L SST flange) Not available with G (Fully forge) mounting style 58

CA Chrome-Moly Grade B-11/F-11 Class II 58

CB Chrome-Moly Grade B-22/ F-22 Class III 58

CC Chrome-Moly Grade F-91 58

NK Nickel 200 58

TT Titanium Grade 2 58

DS Super duplex SST Grade F-53 58


Must order the Q8 Material Certificate to get NORSOK
DT Super duplex – NORSOK 59
documentation
DU Duplex 2205 Grade F51 58
Must order the Q8 Material Certificate to get NORSOK
DV Duplex 2205 – NORSOK 59
documentation

Emerson.com/Rosemount 23
Rosemount 114C April 2017

Table 4. Rosemount 114C Flanged Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Place #s Ref.
Head length (H)
16-18 page
xx.x-in., 2.25 to 11.25 inches in 1/4-in. increments (when ordered with dimension units code E)
★ xxx Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 2.25-in. for 60
flanges under Class 900)
xxx mm, 45 to 225 mm in 5 mm increments (when ordered with dimension units code M)
★ xxx 60
Example of a 50 mm length: 050 (default head length = 60 mm for flanges under Class 900)
Place #
Instrument connection Details Image
19
★ A / –14 NPT
1 2 61
★ B / –14 NPSM
1 2 61

C / –14 NPT
3 4 61

D M18 ⫻ 1.5p 61

E M20 ⫻ 1.5p 61
Female threads
F M24 ⫻ 1.5p 61

G G 1/2-in. (BSPF) 61

H G 3/4-in. (BSPF) 61

J M27 ⫻ 2p 61

K M14 ⫻ 1.5p 61

Options (include with selected model number)


Ref.
Sensor/thermowell assemble to options Details
page
Hand tight assembly of sensor and
★ XT Ensures sensor is threaded into thermowell but only hand tightened 62
thermowell
Process-ready assembly of sensor and Ensures sensor is threaded into thermowell and torqued for
★ XW 62
thermowell process-ready installation
Extended product warranty
★ WR3 3-year limited warranty This warranty option extends manufacturer’s warranty to three or 62
★ WR5 5-year limited warranty five years for manufacturer related defects 62

Thermowell calculation
Set of calculations to ensure thermowells are safe in certain process
conditions
★ R21 Thermowell calculation Note: If your chosen mounting style is flange with full penetration weld (F) then 63
you must choose dye penetration option (Q73) to meet the ASME PTC 19.3 TW
standard requirements.

NACE approval
★ Q35 NACE approval Meets MR0175/ISO 15156 and MR0103 requirements 63

PMI testing
Q76 PMI testing Verifies chemical composition of material 64

24 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 4. Rosemount 114C Flanged Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Ref.
Material certification
page
Certificate for material conformance and traceability in accordance
★ Q8 Material certification 64
with EN 10204 type 3.1
Material tests
M01 Low temperature Charpy Test Measures the low temperature ductility of the material 64

M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 65

Surface finish Details


Q16 Certification Certificate showing measured surface finish values 65

R14 Finish < Ra 0.3 μm (12 μin) Improves surface roughness of thermowell 65

Electropolish
R20 Electropolish Improve smoothness and surface quality 65

Hydrostatic pressure test


Verifies structural quality and checks for leaks at thermowell
★ Q5 External pressure test 66
process connection and stem
★ Q85 Internal pressure test Verifies internal structural integrity of thermowell 66

Canadian Registration Number


Canadian approvals for all provinces (Approved materials in
Q17 Canadian Registration Number 67
reference section)
Dye penetration test
★ Q73 Dye penetration test Checks quality of welds and material 67

Wall thickness test


Q83 Ultrasonic test Checks the bore concentricity of the thermowell 68

Special cleaning
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 68

Thermowell markings
External marking of the thermowell for specific tests (see reference
R40 Test markings on thermowell 68
page for list of tests)
X-ray/radiograph test
Q81 X-ray/radiograph Verifies quality of full penetration flange welds 68

Spherical tip
R60 Spherical tip Changes the flat tip to spherical 69

Plug and chain


R06 Stainless steel 69
Protects thermowell threads when sensor is not installed
R23 Brass 69

Emerson.com/Rosemount 25
Rosemount 114C April 2017

Table 4. Rosemount 114C Flanged Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Ref.
Vent hole
page
R11 Vent hole Allows for the venting of a thermowell 70

Flange face
R09 Concentric serrations Concentric serrations on flange face per ASME B16.5 70

R10 Flat Flat flange face per ASME B16.5 or EN 1092-1 facing Type A 71

R15 Raised face, Type B2 Raise face per EN 1092-1 facing Type B2 71

R16 RTJ Ring type joint flange face per ASME B16.5 72

R18 Groove, Type D Groove, Type D per EN 1092-1 73

R19 Tongue, Type C Tongue, Type C per EN 1092-1 73

R24 Spigot, Type E Spigot Type E per EN 1092-1 74

R25 Recess, Type F Recess Type F per EN 1092-1 75

A
Root diameter (A)

x.xx inches, 0.36 to 3.15 inches in 0.01-in. increments (when ordered with dimension units code E)
Axxx 76
Examples: Code A040 = 0.4-in, Code A315 = 3.15-in.

x.xx mm, 10 to 80 mm in 0.5-mm increments (when ordered with dimension units code M)
Axxx 76
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm

B
Tip diameter (B)

x.xx-in., 0.36 to 1.83 inches in 0.01-in. increments (when ordered with dimension units code E)
Bxxx 77
Examples: Code B040 = 0.4-in, Code B180 = 1.80-in.

xx.x mm, 10 to 46 mm in 0.5 mm. increments (when ordered with dimension units code M)
Bxxx 77
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm

Non-standard bore diameter (d) Details Image


D01 0.276-in./7.0 mm 78
d
D03 0.138-in./3.5 mm 78

D04 0.386-in./9.8 mm Standard = 0.26-in. (6.6 mm) 78

D05 0.354-in./9.0 mm 78

D06 0.433-in./11.0 mm 78

26 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 4. Rosemount 114C Flanged Ordering Information


The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject
to additional delivery lead time.
Ref.
Non-standard tip thickness (t)
page
T01 0.197-in./5.0 mm 78
Standard = 0.25-in. (6.4 mm)
T02 0.236-in./6.0 mm 78
t

Flanged installation
Flanged thermowells are bolted to a mating flange which protrudes from the process. It is important to select appropriate gasket for
the process conditions, to provide a seal between the flange faces. The Rosemount 114C Thermowells come standard with a raised
face and spiral serrations designed per the ASME B16.5 standard. These should be installed with an inside bolt circle (IBC) gasket/ring
gasket, which extends to and is centered by the bolts. Other flange face options are available.

Figure 11. Installation Components


A

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

Emerson.com/Rosemount 27
Rosemount 114C April 2017

Flanged thermowell drawings

Figure 12. Flange Mounted Thermowell Drawings(1)


Straight Tapered Stepped

C
H

A A

d
E U

B B B
A. Root diameter N. Instrument connection
B. Tip diameter U. Immersion length
C. ASME B16.5 lap flange d. Bore diameter
E. Total length (U + H) t. Tip thickness
H. Head length

1. Total length = U+H.

28 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 5. Flange Mounted Thermowells(1)


Process connection Root
Root
diameter Tip diameter Tip diameter Flanges per
Code

Code P, flanged, diameter


Code F, flanged, full Code G, flanged, stepped tapered stem straight stem specification
partial penetration tapered stem
penetration weld forged/no welds stem
weld
AA 1-in. Class 150 1-in. Class 150 1-in. Class 150 19 (.748) 22.5 (.886) 16 (.630) 19 (.748)
AB 11/2-in. Class 150 11/2-in. Class 150 11/2-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AC 2-in. Class 150 2-in. Class 150 2-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AD 3-in. Class 150 3-in. Class 150 3-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AE 4-in. Class 150 4-in. Class 150 4-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AF 6-in. Class 150 6-in. Class 150 6-in. Class 150 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AG 3/4-in. Class 300 3/4-in. Class 300 3/4-in. Class 300 17 (.669) 17 (.669) 12.5 (.495) 17 (.669)
AH 1-in. Class 300 1-in. Class 300 1-in. Class 300 19 (.748) 22.5 (886) 16 (.630) 19 (.748)
AJ 11/2-in. Class 300 11/2-in. Class 300 11/2-in. Class 300 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AK 2-in. Class 300 2-in. Class 300 2-in. Class 300 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
ASME B16.5
AL 1-in. Class 400/600 1-in. Class 400/600 1-in. Class 400/600 19 (.748) 22.5 (886) 16 (.630) 19 (.748)
AM 11/2-in. Class 400/600 11/2-in. Class 400/600 11/2-in. Class 400/600 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AN 2-in. Class 400/600 2-in. Class 400/600 2-in. Class 400/600 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AP N/A 1-in. Class 900/1500 1-in. Class 900/1500 19 (.748) 22.5 (886) 16 (.630) 19 (.748)
11/2-in. Class
AQ N/A 11/2-in. Class 900/1500 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
900/1500
AR N/A 2-in. Class 900/1500 2-in. Class 900/1500 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AT N/A 11/2-in. Class 2500 11/2-in. Class 2500 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AU N/A 2-in. Class 2500 2-in. Class 2500 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
AV 3-in. Class 300 3-in. Class 300 3-in. Class 300 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
FA DN 20/PN 2.5/6 DN 20/PN 2.5/6 DN 20/PN 2.5/6 17 (.669) 17 (.669) 12.7 (.500) 17 (.669)
DN 20/PN DN 20/PN DN 20/PN
FE 17 (.669) 17 (.669) 12.7 (.500) 17 (.669)
10/16/25/40 10/16/25/40 10/16/25/40
FG DN 20/PN 63/100 DN 20/PN 63/100 DN 20/PN 63/100 17 (.669) 17 (.669) 12.7 (.500) 17 (.669)
GA DN 25/PN 2.5/6 DN 25/PN 2.5/6 DN 25/PN 2.5/6 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
DN 25/PN DN 25/PN DN 25/PN
GE 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
10/16/25/40 10/16/25/40 10/16/25/40
GG DN 25 PN 63/100 DN 25 PN 63/100 DN 25/PN 63/100 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
GH DN 25/PN 160 DN 25/PN 160 DN 25/PN 160 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
GJ DN 25/PN 250 DN 25/PN 250 DN 25/PN 250 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
GK DN 25/PN 320 DN 25/PN 320 DN 25/PN 320 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
GL DN 25/PN 400 DN 25/PN 400 DN 25/PN 400 19 (.748) 19 (.748) 12.7 (.500) 19 (.748)
JA DN 40/PN 2.5/6 DN 40/PN 2.5/6 DN 40/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
DN 40/PN DN 40/PN DN 40/PN
EN 1092-1
JE 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
10/16/25/40 10/16/25/40 10/16/25/40
JG DN 40/PN 63/100 DN 40/PN 63/100 DN 40/PN 63/100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
JH DN 40/PN 160 DN 40/PN 160 DN 40/PN 160 21.5 (.846) 26.5 (1.043) 16 (.630) 21.5 (.846)
JJ DN 40/PN 250 DN 40/PN 250 DN 40/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
JK DN 40/ PN 320 DN 40/ PN 320 DN 40/ PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
JL DN 40/PN 400 DN 40/PN 400 DN 40/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KA DN 50/PN 2.5/6 DN 50/PN 2.5/6 DN 50/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KC DN 50/PN 10/16 DN 50/PN 10/16 DN 50/PN 10/16 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KE DN 50/PN 25/40 DN 50/PN 25/40 DN 50/PN 25/40 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KF DN 50/PN 63 DN 50/PN 63 DN 50/PN 63 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KG DN 50/PN 100 DN 50/PN 100 DN 50/PN 100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KH DN 50/PN 160 DN 50/PN 160 DN 50/PN 160 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)

Emerson.com/Rosemount 29
Rosemount 114C April 2017

Table 5. Flange Mounted Thermowells(1)


Process connection Root
Root
diameter Tip diameter Tip diameter Flanges per
Code

Code P, flanged, diameter


Code F, flanged, full Code G, flanged, stepped tapered stem straight stem specification
partial penetration tapered stem
penetration weld forged/no welds stem
weld
KJ DN 50/PN 250 DN 50/PN 250 DN 50/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KK DN 50/PN 320 DN 50/PN 320 DN 50/PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
KL DN 50/PN 400 DN 50/PN 400 DN 50/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LA DN 65/PN 2.5/6 DN 65/PN 2.5/6 DN 65/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LC DN 65/PN 10/16 DN 65/PN 10/16 DN 65/PN 10/16 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LE DN 65/PN 24/40 DN 65/PN 24/40 DN 65/PN 24/40 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LF DN 65/PN 63 DN 65/PN 63 DN 65/PN 63 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LG DN 65/PN 100 DN 65/PN 100 DN 65/PN 100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LH DN 65/PN 160 DN 65/PN 160 DN 65/PN 160 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LJ DN 65/PN 250 DN 65/PN 250 DN 65/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LK DN 65/PN 320 DN 65/PN 320 DN 65/PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
LL DN 65/PN 400 DN 65/PN 400 DN 65/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MA DN 80/PN 2.5/6 DN 80/PN 2.5/6 DN 80/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MC DN 80/PN 10/16 DN 80/PN 10/16 DN 80/PN 10/16 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
ME DN 80/PN 25/40 DN 80/PN 25/40 DN 80/PN 25/40 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
EN 1092-1
MF DN 80/PN 63 DN 80/PN 63 DN 80/PN 63 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MG DN 80/PN 100 DN 80/PN 100 DN 80/PN 100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MH DN 80/PN 160 DN 80/PN 160 DN 80/PN 160 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MJ DN 80/PN 250 DN 80/PN 250 DN 80/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
MK DN 80/PN 320 DN 80/PN 320 DN 80/PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
ML DN 80/PN 400 DN 80/PN 400 DN 80/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NA DN 100/PN 2.5/6 DN 100/PN 2.5/6 DN 100/PN 2.5/6 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NC DN 100/PN 10/16 DN 100/PN 10/16 DN 100/PN 10/16 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NE DN 100/PN 25/40 DN 100/PN 25/40 DN 100/PN 25/40 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NF DN 100/PN 63 DN 100/PN 63 DN 100/PN 63 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NG DN 100/PN 100 DN 100/PN 100 DN 100/PN 100 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NH DN 100/PN 160 DN 100/PN 160 DN 100/PN 160 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NJ DN 100/PN 250 DN 100/PN 250 DN 100/PN 250 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NK DN 100/PN 320 DN 100/PN 320 DN 100/PN 320 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)
NL DN 100/PN 400 DN 100/PN 400 DN 100/PN 400 21.5 (.846) 26.5 (1.043) 18 (.709) 21.5 (.846)

1. Dimensions are in inches (millimeters).

Table 6. External Pressure Test–EN 1092-1


EN 1092-1 flanged thermowells
Nominal pressure (bar) Test pressure (bar)
16 40
40 100
100 250
Test to 2.5⫻ nominal pressure rating

30 Emerson.com/Rosemount
April 2017 Rosemount 114C

Rosemount 114C Van Stone Thermowells

Emerson.com/Rosemount 31
Rosemount 114C April 2017

Van Stone thermowell overview


Van Stone/lap Joint thermowells are mounted between the mating flange and lap joint flange. This unique design enables thermowell
designers to specify thermowell flange materials different than the thermowell stem material; flanges are easily replaceable. These
thermowells allow use of different thermowell materials for the flange contacting the process and overlaying flange which can save
material and manufacturing costs. They are a good choice for corrosive applications, because there are no welds so weld-joint
corrosion is eliminated. The Emerson standard for the Van Stone thermowell is a raised face style made of carbon steel. Other styles
and flange materials are also available.
The standard offering figure below shows the thermowell configurations that can typically be shipped in two weeks or less.

Figure 13. Standard Offering–Van Stone


Model Units Immersion Mounting Process Stem Thermowell Head Instrument Options
length (U) style connection style material length (H) connection threads
1 1 4 C X X X X X V X X X X X X X X X XX, XXX, XX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Common options
(16-18) Head length (H) Q5 External pressure test
XXX 2.25- to 11.25-in. (E) Q35 NACE approval
(5) Units (10) Mounting style (13) Stem style
Example: 2.25-in. = 022, R21 Thermowell calculation
English (E) Van Stone (V) 1 Straight stem 10-in. = 100 Q8 Material certification
Metric (M) 2 Tapered stem XXX 40 to 225 mm (M) C01 Van Stone w/no cover flange
Example: 40 mm = 040, C02 Van Stone w/SST cover flange
3 Stepped stem 225 mm = 225
(6-9) Immersion length (U)
XXXX 0.5- to 42-in. (E) (11-12) Process connections (14-15) Thermowell material (19) Instrument connection
Example: 0.5-in. = 0005,
42-in. = 0420 AA 1-in. Class 150 SC 316/316L SST A ½-14 NPT
XXXX 25 to 1165 mm (M) AB 1½-in. Class 150 SF 304/304L SST B ½-14 NPSM
Example: 25 mm = 0025,
1165 mm = 1165 AC 2-in. Class 150 CS Carbon steel D M18 x 1.5p
E M20 x 1.5p
F M24 x 1.5p

The common options shown in Figure 13 represent a partial offering; reference the Rosemount 114C Van Stone Ordering Information
for a full list of available options.

Figure 14. Van Stone Thermowell Components


H U

A. Instrument connection H. Head length


B. Process connection U. Immersion length

Note
Wetted surface includes flange face and immersion length (U).

32 Emerson.com/Rosemount
April 2017 Rosemount 114C

Use the form below to record your model code:


Immersion Mounting Process Stem Thermowell Instrument
Model Units Head length (H) Options
length (U) style connection style material connection

1 1 4 C V
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 XXXXX

Emerson.com/Rosemount 33
Rosemount 114C April 2017

Van Stone ordering information


Figure 15. Model Number Ordering Example
Immersion Mounting Process Stem Thermowell Instrument
Model Units Head length (H) Options
length (U) style connection style material connection

WR5,
1 1 4 C M 0 1 5 0 V A B 1 S C 0 5 0 A
Q76...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 XXXXX

The numbers below the model number ordering example correlate to the character place numbers in the second column of the
ordering table.

Table 7. Rosemount 114C Van Stone Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
Place #s Ref.
Model Details
1-4 page
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip
★ 114C Barstock temperature thermowell N/A
wall thickness of 0.25-in. (6.4 mm)
Place #
Dimension units
5
★ E English units (inches) Specifies whether length units will be in inches (in) or 56
★ M Metric units (mm) millimeters (mm) 56

Place #
Immersion length (U)
6-9

xx.x-in., 1.0 to 100 inches in 1/4-in. increments (when ordered with dimension units code E)
★ xxxx 56
Example of a 6.25-in. length where the second decimal is dropped off: 0062

xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
★ xxxx 56
Example of a 25 mm length: 0025
Place #
Mounting style
10
★ V Van Stone, lap flange Default cover flange material is carbon steel N/A
Place #s
Process connection
11-12
★ AA 1-in. Class 150 N/A
★ AB 11/2-in. Class 150 N/A
★ AC 2-in. Class 150 N/A

34 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 7. Rosemount 114C Van Stone Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
★ AH 1-in. Class 300 N/A
★ AJ 11/2-in. Class 300 N/A
★ AK 2-in. Class 300 N/A
★ AL 1-in. Class 400/600 N/A
★ AM 11/2-in. Class 400/600 N/A
★ AN 2-in. Class 400/600 N/A

AP 1-in. Class 900/1500 N/A

AQ 11/2-in. Class 900/1500 N/A

AR 2-in. Class 900/1500 N/A

AS 1-in. Class 2500 N/A

AT 11/2-in. Class 2500 N/A

AU 2-in. Class 2500 N/A


Place # Ref.
Stem style Details Image
13 page

Minimum immersion length


★ 1 Straight 57
= 1-in. (25 mm)

Minimum immersion length


★ 2 Tapered 57
= 1-in. (25 mm)

Minimum immersion length


★ 3 Stepped 57
= 3-in. (75 mm)

Place #s
Thermowell material
14-15
★ SC 316/316L dual rated 58
Must order the Q8 Material Certificate to get NORSOK
SD 316/316L dual rated (NORSOK) 59
documentation
★ SF 304/304L dual rated 58

Emerson.com/Rosemount 35
Rosemount 114C April 2017

Table 7. Rosemount 114C Van Stone Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
★ CS Carbon steel (A-105) 58

SG 316Ti SST 58

SH 316/316L SST with tantalum sheath 58

SJ 316/316L SST with PFA coating 58

SK 304/304L SST with PTFE coating 58

SL 310 SST 58

SM 321 SST 58

AB Alloy B3 58

AC Alloy C-276 58

AG Alloy 20 58

AH Alloy 400 58

AK Alloy 600 58

MO Molybdenum 58

CA Chrome-Moly Grade B-11/F-11 Class II 58

CB Chrome-Moly Grade B-22/ F-22 Class III 58

CC Chrome-Moly Grade F-91 58

NK Nickel 200 58

TT Titanium Grade 2 58

DS Super duplex SST Grade F-53 58


Must order the Q8 Material Certificate to get NORSOK
DT Super duplex – NORSOK 59
documentation
DU Duplex 2205 Grade F51 58
Must order the Q8 Material Certificate to get NORSOK
DV Duplex 2205 – NORSOK 59
documentation
H

Place #s
Head length (H)
16-18

xx.x-in., 1.75to 11.25 inches in 1/4-in. increments (when ordered with Dimension units code E)
★ xxx Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 2.25 inches 60
for flanges under Class 900)
xxx mm, 40 to 225 mm in 5 mm increments (when ordered with Dimension units code M)
★ xxx 60
Example of a 50 mm length: 050 (default head length = 60 mm for flanges under Class 900)

36 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 7. Rosemount 114C Van Stone Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
Place # Ref.
Instrument connection Details Image
19 page
★ A / –14 NPT
1 2 61
★ B / –14 NPSM
1 2 61

C / –14 NPT
3 4 61

D M18 ⫻ 1.5p 61

E M20 ⫻ 1.5p 61
Female threads
F M24 ⫻ 1.5p 61

G G 1/2-in. (BSPF) 61

H G 3/4-in. (BSPF) 61

J M27 ⫻ 2p 61

K M14 ⫻ 1.5p 61

Options (include with selected model number)


Ref.
Sensor/thermowell assemble to options Details
page
Hand tight assembly of sensor and
★ XT Ensures sensor is threaded into thermowell but only hand tightened 62
thermowell
Process-ready assembly of sensor and Ensures sensor is threaded into thermowell and torqued for
★ XW 62
thermowell process-ready installation
Extended product warranty
★ WR3 3-year limited warranty This warranty option extends manufacturer’s warranty to three or 62
★ WR5 5-year limited warranty five years for manufacturer related defects 62

Thermowell calculation
Set of calculations to ensure thermowells are safe in certain process
★ R21 Thermowell calculation 63
conditions
NACE approval
★ Q35 NACE approval Meets MR0175/ISO 15156 and MR0103 requirements 63

PMI testing
Q76 PMI testing Verifies chemical composition of material 64

Material certification
Certificate for material conformance and traceability in accordance
★ Q8 Material certification 64
with EN 10204 type 3.1
Material tests
M01 Low temperature Charpy Test Measures the low temperature ductility of the material 64

M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 65

Emerson.com/Rosemount 37
Rosemount 114C April 2017

Table 7. Rosemount 114C Van Stone Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
Ref.
Surface finish Details
page
Q16 Certification Certificate showing measured surface finish values 65

R14 Finish < Ra 0.3 μm (12 μin) Improves surface roughness of thermowell 65

Electropolish
R20 Electropolish Improve smoothness and surface quality 65

Hydrostatic pressure test


Verifies structural quality and checks for leaks at thermowell process
★ Q5 External pressure test 66
connection and stem
★ Q85 Internal pressure test Verifies internal structural integrity of thermowell 66

Canadian Registration Number


Canadian approvals for all provinces (Approved materials in
Q17 Canadian Registration Number 67
reference section)
Dye penetration test
★ Q73 Dye penetration test Checks quality of welds and material 67

Wall thickness test


Q83 Ultrasonic test Checks the bore concentricity of the thermowell 68

Special cleaning
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 68

Thermowell markings
External marking of the thermowell for specific tests (see reference
R40 Test markings on thermowell 68
page for list of tests)
Spherical tip
R60 Spherical tip Changes the flat tip to spherical 69

Plug and chain


R06 Stainless steel 69
Protects thermowell threads when sensor is not installed
R23 Brass 69

Vent hole
R11 Vent hole Allows for the venting of a thermowell 70

Flange face
R09 Concentric serrations Concentric serrations on flange face per ASME B16.5 70
R16 RTJ Ring type joint flange face per ASME B16.5 71

38 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 7. Rosemount 114C Van Stone Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.

A
Ref.
Root diameter (A)
page

x.xx-in., 0.36 to 3.15 inches in 0.01-in. increments (when ordered with dimension units code E)
Axxx 76
Examples: Code A040 = 0.4-in, Code A315 = 3.15-in.

xx.x mm, 10 to 80 mm in 0.5 mm increments (when ordered with dimension units code M)
Axxx 76
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm

B
Tip diameter (B)

x.xx-in., 0.36 to 1.83 inches in 0.01-in. increments (when ordered with dimension units code E)
Bxxx 77
Examples: Code B040 = 0.4-in, Code B180 = 1.80-in.

xx.x mm, 10 to 46 mm in 0.5 mm. increments (when ordered with dimension units code M)
Bxxx 77
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm

Non-standard bore diameter (d) Details Image


D01 0.276-in./7.0 mm 78
d
D03 0.138-in./3.5 mm 78
Standard = 0.26-in.
D04 0.386-in./9.8 mm 78
(6.6mm)
D05 0.354-in./9.0 mm 78

D06 0.433-in./11.0 mm 78

Non-standard tip thickness (t)


T01 0.197-in./5.0 mm 78
Standard = 0.25-in.
T02 0.236-in./6.0 mm (6.4 mm) 78
t
Lap flange material for Van Stone design
C01 No flange Provides a Van Stone stem without a lap flange. 79

C02 316/316LSST flange Provides a Van Stone stem with a 316/316LSST lap flange. 79
Provides a Van Stone stem with a matching lap flange per stem
C03 Flange per stem material 79
material. Coatings do not apply to lap flange.

Emerson.com/Rosemount 39
Rosemount 114C April 2017

Van Stone installation Figure 16. Installation Components


A
Van Stone thermowells are installed using a lap joint flange
which slips over the stub end of the thermowell. The lap joint B
flange has no flange face. Instead the flange is bolted over the C
stub end which acts as the flange face and compresses the
gasket. The Rosemount 114C Thermowells come standard with
D
spiral serrations on the stub end designed per the ASME B16.5
standard. These should be installed with an inside bolt circle
(IBC) gasket/ring gasket, which extends to and is centered by the
bolts. Other flange face options are available. E

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

40 Emerson.com/Rosemount
April 2017 Rosemount 114C

Van Stone thermowell drawings


Figure 17. Van Stone/Lap Flanged Mounted Thermowell Drawings(1)
Straight Tapered Stepped

C
N

H E

G F A
A

B
B B

A. Root diameter F. Stub thickness d. Bore diameter


B. Tip diameter H. Head length t. Tip thickness
C. Head diameter N. Instrument connection (1/2-in. NPT)
E. ASME B16.5 lap flange U. Immersion length

1. Total length = U + H.

Emerson.com/Rosemount 41
Rosemount 114C April 2017

Table 8. Van Stone/Lap Flanged Mounted Thermowells(1)


Code V, Van Stone lap Stub Stub Stub
Stub
flange mounting style Lagging diameter diameter thickness Root Root Tip Tip
thickness
diameter K K ring “F” diameter diameter diameter diameter
Code

“F”
“C” standard type joint ring type stepped tapered tapered straight
Process connection standard
raised option joint stem stem stem stem
raised face
face R16 option R16
1.31 1.99 2.50 0.644 0.75 0.89 0.63 .75
AA 1-in. Class 150
(33.4) (50.8) (63.5) (16.35) (19) (22.5) (16) (19)
1.90 2.87 3.25 0.644 0.85 1.04 0.71 .85
AB 11/2-in. Class 150
(48.3) (73) (82.5) (16.35) (21.5) (26.5) (18) (21.5)
2.37 3.62 4 0.644 0.85 1.04 0.71 .85
AC 2-in. Class 150
(60.3) (92.1) (102) (16.35) (21.5) (26.5) (18) (21.5)
1.31 1.99 2.75 0.644 0.75 0.89 0.63 .75
AH 1-in. Class 300
(33.4) (50.8) (70) (16.35) (19) (22.5) (16) (19)
1.90 2.87 3.56 0.644 0.85 1.04 0.71 .85
AJ 11/2-in. Class 300
(48.3) (73) (90.5) (16.35) (21.5) (26.5) (18) (21.5)
2.37 3.62 4.25 0.707 0.85 1.04 0.71 .85
AK 2-in. Class 300
(60.3) (92.1) (108) (17.92) (21.5) (26.5) (18) (21.5)
1.31 1.99 2.75 0.644 0.75 0.89 0.63 .75
AL 1-in. Class 400/600
(33.4) (50.8) (70) (16.35) (19) (22.5) (16) (19)
1.90 2.87 3.56 10 0.644 0.85 1.04 0.71 .85
AM 11/2-in. Class 400/600
(48.3) (73) (90.5) (.394) (16.35) (21.5) (26.5) (18) (21.5)
2.37 3.62 4.25 0.707 0.85 1.04 0.71 .85
AN 2-in. Class 400/600
(60.3) (92.1) (108) (17.92) (21.5) (26.5) (18) (21.5)
1.31 1.99 2.81 0.644 0.75 0.89 0.63 .75
AP 1-in. Class 900/1500
(33.4) (50.8) (71.5) (16.35) (19) (22.5) (16) (19)
1.90 2.87 3.62 0.644 0.85 1.04 0.71 .85
AQ 11/2-in. Class 900/1500
(48.3) (73) (92) (16.35) (21.5) (26.5) (18) (21.5)
2.37 3.62 4.88 0.707 0.85 1.04 0.71 .85
AR 2-in. Class 900/1500
(60.3) (92.1) (124) (17.92) (21.5) (26.5) (18) (21.5)
1.31 1.99 3.25 0.644 0.75 0.89 0.63 .75
AS 1-in. Class 2500
(33.4) (50.8) (82.5) (16.35) (19) (22.5) (16) (19)
1.90 2.87 4.50 0.707 0.85 1.04 0.71 .85
AT 11/2-in. Class 2500
(48.3) (73) (114) (17.92) (21.5) (26.5) (18) (21.5)
2.37 3.62 5.25 0.707 0.85 1.04 0.71 .85
AU 2-in. Class 2500
(60.3) (92.1) (133) (17.92) (21.5) (26.5) (18) (21.5)

1. Dimensions are in inches (millimeters).

42 Emerson.com/Rosemount
April 2017 Rosemount 114C

Rosemount 114C Welded Thermowells

Emerson.com/Rosemount 43
Rosemount 114C April 2017

Welded thermowell overview


Welded thermowells are permanently welded to process pipes or tanks. Welded thermowells have the highest pressure rating and
are generally used in applications with high velocity flow, high temperature, or extremely high pressure. They are necessary where a
leak-proof seal is required.
The standard offering figure below shows the thermowell configurations that can typically be shipped in two weeks or less.

Figure 18. Standard Offering–Welded


Model Units Immersion Mounting Process Stem Thermowell Head Instrument Options
length (U) style connection style material length (H) connection threads
1 1 4 C X X X X X W X X X X X X X X X XX, XXX, XX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

(16-18) Head Length (U) Common options

(5) Units (10) Mounting style (13) Stem style XXX 1.75- to 11.25-in. (E) Q35 NACE approval
Example: 1.75-in. = 017, R21 Thermowell
English (E) Socket weld (W) 1 Straight stem 10-in. = 100 calculation
Metric (M) Weld in (D) 2 Tapered stem XXX 40 to 225 mm (M) Q8 Material certification
Example: 40 mm = 040,
3 Stepped stem 225 mm = 225 Q73 Dye penetration test
(6-9) Immersion length (U)
XXXX 0.5- to 42-in. (E) (11-12) Process connections (14-15) Thermowell material (19) Instrument connection
Example: 0.5-in. = 0005,
42-in. = 0420 AA ¾-in. Pipe SC 316/316L SST A ½-14 NPT
XXXX 25 to 1165 mm (M) AB 1-in. Pipe SF 304/304L SST B ½-14 NPSM
Example: 25 mm = 0025,
1165 mm = 1165 AC 1 1/4-in. Pipe D M18 x 1.5p
AD 1½-in. Pipe E M20 x 1.5p
F M24 x 1.5p

The common options shown in Figure 18 represent a partial offering; reference the Rosemount 114C Welded Ordering Information
for a full list of available options.

Figure 19. Welded Thermowell Components

Socket weld Weld-in

H U H U

A
A

B B
A. Instrument connection U. Immersion length
B. Process connection (dependent on weld point) H. Head length

Note
Actual wetted surface varies; it is measured from the weld point to the thermowell tip.

44 Emerson.com/Rosemount
April 2017 Rosemount 114C

Use the form below to record your model code:


Immersion Mounting Process Stem Thermowell Instrument
Model Units Head length (H) Options
length (U) style connection style material connection

1 1 4 C
1 2 3 4 5 6 through 9 10 11 and 12 13 14 and 15 16 through 18 19 XXXXX

Emerson.com/Rosemount 45
Rosemount 114C April 2017

Welded ordering information


Figure 20. Model Number Ordering Example
Immersion Mounting Process Stem Thermowell Instrument
Model Units Head length (H) Options
length (U) style connection style material connection

WR5,
1 1 4 C E 0 0 6 0 W A B 1 S C 0 5 0 A
Q76...
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 XXXXX

The numbers below the model number ordering example correlate to the character place numbers in the second column of the
ordering table.

Table 9. Rosemount 114C Welded Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
Place #s Ref.
Model Details
1-4 page
Made with a standard bore diameter of 0.26-in. (6.6 mm) and tip
★ 114C Barstock temperature thermowell N/A
wall thickness of 0.25-in. (6.4 mm)
Place #
Dimension units
5
★ E English units (inches) Specifies whether length units will be in inches (in) or 56
★ M Metric units (mm) millimeters (mm) 56

U U
Place #
Immersion length (U)
6-9

xxx-in., 1 to 100 inches in 1/4-in. increments (when ordered with dimension units code E)
★ xxxx 56
Example of a 6.25-in. length where the second decimal is dropped off: 0062
xxxx mm, 25 to 2500 mm in 5 mm increments (when ordered with dimension units code M)
★ xxxx 56
Example of a 50 mm length: 0050
Place #
Mounting style
10
★ W Welded–socket weld N/A
★ D Welded–weld-in (only available in tapered stem profile) N/A
Place #s
Process connections
11-12
Welded–socket weld (W) Welded–weld-in (D) (only available in tapered stem profile)
★ AA / -in. pipe
3 4 / -in. pipe
3 4 N/A
★ AB 1-in. pipe 1-in. pipe N/A
★ AC 11/4-in pipe 11/4-in pipe N/A
★ AD 11/2-in. pipe 11/2-in. pipe N/A
Custom diameters (required for Root [Axxx] and tip [Bxxx]
AE N/A N/A
modifications)

46 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 9. Rosemount 114C Welded Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
DA N/A DIN 43772-4-7 (18 h7/3.5 mm bore/M14) N/A

DB N/A DIN 43772-4-7 (24 h7/7.0 mm bore/M18) N/A

DC N/A DIN 43772-4-7 (26 h7/7.0 mm bore/G1/2 or M20) N/A

DD N/A DIN 43772-4-7 (26 h7/9.0 mm bore/G1/2 or M20) N/A

DE N/A DIN 43772-4-7 (32 h11/11.0 mm bore/G3/4 or M27) N/A


Place # Ref.
Stem style Details Image
13 page
Minimum immersion length =
★ 1 Straight 57
1-in. (25 mm)

Minimum immersion length =


★ 2 Tapered 57
1-in. (25 mm)

Minimum immersion length =


★ 3 Stepped 57
3-in. (75 mm)

Place #s
Thermowell material Details
14-15
★ SC 316/316L dual rated 58
Must order the Q8 Material Certificate to get NORSOK
SD 316/316L dual rated (NORSOK) 59
documentation
★ SF 304/304L dual rated 58
★ CS Carbon steel (A-105) 58

SG 316Ti SST 58

SL 310 SST 58

SM 321 SST 58
AB Alloy B3 58

AC Alloy C-276 58

AG Alloy 20 58

AH Alloy 400 58

AK Alloy 600 58

MO Molybdenum 58

CA Chrome-Moly Grade B-11/F-11 Class II 58

CB Chrome-Moly Grade B-22/ F-22 Class III 58

CC Chrome-Moly Grade F-91 58

NK Nickel 200 58

TT Titanium Grade 2 58

DS Super duplex SST Grade F-53 58


Must order the Q8 Material Certificate to get NORSOK
DT Super duplex – NORSOK 59
documentation

Emerson.com/Rosemount 47
Rosemount 114C April 2017

Table 9. Rosemount 114C Welded Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
DU Duplex 2205 Grade F51 58
Must order the Q8 Material Certificate to get NORSOK
DV Duplex 2205 – NORSOK 59
documentation
H
H
Place #s Ref.
Head length (H)
16-18 page

xx.x-in., 1.75 to 11.25 inches in 1/4-in. increments (when ordered with dimension units code E)
★ xxx 60
Example of a 6.25-in. length where the second decimal is dropped off: 062 (default head length = 1.75-in.)
xxx mm, 40 to 225 mm in 5-mm increments (when ordered with dimension units code M)
★ xxx 60
Example of a 50 mm length: 050 (default head length = 45 mm)
Place #
Instrument connection Details Image
19
★ A / –14 NPT
1 2 61
★ B / –14 NPSM
1 2 61

C / –14 NPT
3 4 61

D M18 ⫻ 1.5p 61

E M20 ⫻ 1.5p 61
Female threads
F M24 ⫻ 1.5p 61

G G 1/2-in. (BSPF) 61

H G 3/4-in. (BSPF) 61

J M27 ⫻ 2p 61

K M14 ⫻ 1.5p 61

Options (include with selected model number)


Ref.
Sensor/thermowell assemble to options Details
page
Hand tight assembly of sensor and
★ XT Sensor is threaded into thermowell but only hand tightened 62
thermowell
Extended product warranty
★ WR3 3-year limited warranty This warranty option extends manufacturer’s warranty to three or 62
★ WR5 5-year limited warranty five years for manufacturer related defects 62

Thermowell calculation
Set of calculations to ensure thermowells are safe in certain
★ R21 Thermowell calculation 63
process conditions

48 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 9. Rosemount 114C Welded Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
Ref.
NACE approval Details
page
★ Q35 NACE approval Meets MR0175/ISO 15156 and MR0103 requirements 63

PMI testing
Q76 PMI testing Verifies chemical composition of material 64

Material certification
Certificate for material conformance and traceability in
★ Q8 Material certification 64
accordance with EN 10204 type 3.1
Material tests
M01 Low temperature Charpy Test Measures the low temperature ductility of the material 64

M02 Ultrasonic material test Examination of steel forgings for flaws and inclusions 65

Surface finish
Q16 Certification Certificate showing measured surface finish values 65

R14 Finish < Ra 0.3μm (12μin) Improves surface roughness of thermowell 65

Electropolish
R20 Electropolish Improves smoothness and surface quality 65

Hydrostatic pressure test


★ Q85 Internal pressure test Verifies internal structural integrity of thermowell 66

Canadian Registration Number


Canadian approvals for all provinces (Approved materials in
Q17 Canadian Registration Number 67
reference section)
Dye penetration test
★ Q73 Dye penetration test Checks quality of welds and material 67

Wall thickness test


Q83 Ultrasonic test Checks the bore concentricity of the thermowell 68

Special cleaning
Q6 Special cleaning Oxygen enriched environment cleaning per ASTM G93 68

Thermowell markings
External marking of the thermowell for specific tests (see
R40 Test markings on thermowell 68
reference page for list of tests)
Spherical tip
R60 Spherical tip Changes the flat tip to spherical 69

Plug and chain


R06 Stainless steel 69
Protects thermowell threads when sensor is not installed
R23 Brass 69

Emerson.com/Rosemount 49
Rosemount 114C April 2017

Table 9. Rosemount 114C Welded Ordering Information


★The Standard offering represents the most common options. The starred options (★) should be selected for best delivery lead time.
The Expanded offering is subject to additional delivery lead time.
Ref.
Vent hole Details
page
R11 Vent hole Allows for the venting of a thermowell 70

A
Root diameter (A)

x.xx-in., 0.36 to 3.15 inches in 0.01-in. increments (when ordered with dimension units code E)
Axxx 76
Examples: Code A040 = 0.4-in, Code A315 = 3.15-in.

xx.xx mm, 10 to 80 mm in 0.5 mm increments (when ordered with dimension units code M)
Axxx 76
Examples: Code A100 = 10.0 mm, Code A755 = 75.5 mm

B
Tip diameter (B)

x.xx-in., 0.36 to 1.83 inches in 0.01-in. increments (when ordered with dimension units code E)
Bxxx 77
Examples: Code B040 = 0.4-in, Code B180 = 1.80-in.

xx.xx mm, 10 to 46 mm in 0.5 mm. increments (when ordered with dimension units code M)
Bxxx 77
Examples: Code B100 = 10.0 mm, Code B455 = 45.5 mm

Non-standard bore diameter (d) Details Image


D01 0.276-in./7.0 mm 78

D03 0.138-in./3.5 mm d 78

D04 0.386-in./9.8 mm Standard = 0.26-in. (6.6 mm) 78

D05 0.354-in./9.0 mm 78

D06 0.433-in./11.0 mm 78

Non-standard tip thickness (t)


T01 0.197-in./5.0 mm 78
Standard = 0.25-in. (6.4 mm)
T02 0.236-in./6.0 mm 78
t

Socket weld installation


Socket weld thermowells are typically welded into a socket weld fitting. Welds should be designed according to the appropriate
standards. It is important to order a head length (H) that leaves enough space so the instrument threads will not be deformed by
welding at installation. The customer should also make sure the root diameter of the thermowell will fit through the inner diameter of
the weld fitting.

Note
When specified in a thermowell calculation, the unsupported length for a socket weld thermowell is from the point of weld (B shown
on Figure 21 on page 51) to the thermowell tip.

50 Emerson.com/Rosemount
April 2017 Rosemount 114C

Figure 21. Installation Components


A

B
C
D
E

A. Thermowell
B. Weld
C. Socket weld fitting
D. 1/16-in. gap
E. Weld
F. Process

Weld-in Type 4 thermowells according to DIN 43772


This section only defines the requirement necessary to provide a Type 4 thermowell according to the DIN 43772 Standard (for
ordering information on weld-in thermowells outside the DIN Standard, see Table 9 on page 46).
The illustration below shows the breakdown of a model according to the DIN Standard:
Thermowell – DIN 43772 – 4 – 7 – M18 ⫻ 1.5 – 200 – 65 – 16Mo3

Name

Standard number

Type

Thermowell inside
diameter d1
Thermometer
connection thread N

Overall length L

Immersion length U

Material abbreviation
or material number
Table 10, Table 11, and Table 12 show all required thermowell dimensions necessary to conform to DIN 43772 Type 4 and the
relationship to the Rosemount 114C Thermowell.
Ordering process
1. Select overall length (L) and immersion length (U) from Table 10.
U = 65 mm L = 200 mm H = L – U = 135 mm
Rosemount 114C = U = 0065 Rosemount 114C = H = 135

Emerson.com/Rosemount 51
Rosemount 114C April 2017

Table 10. DIN Required Lengths


Overall length (L)
Immersion length (U) Head length (H)
(U + H)
(mm) Code (mm) (mm) Code
65 0065 110 45 045
65 0065 140 75 075
65 0065 200 135 135
125 0125 260 135 135
275 0275 410 135 135
2. Select process connection (PC), instrument connection (IC), and bore diameter (BD) from Table 11.
PC = 18 h7/3.5 mm IC = M14 ⫻ 1.5 BD = 3.5 mm
Rosemount 114C = 18 h7/3.5 mm = DA Rosemount 114C = M14 ⫻ 1.5 = K Rosemount 114C = 3.5 mm = D03
Table 11. DIN Connection Information
Process connection (PC) Instrument connection (IC) Bore diameter (BD)
Type Code Internal threads Code (mm) Code
18 h7 DA M14 ⫻ 1.5 K 3.5 D03
24 h7 DB M18 ⫻ 1.5 D 7.0 D01
26 h7 DC G1/2 (BSPF) G 7.0 D01
26 h7 DD M20 ⫻ 1.5 E 9.0 D05
32 h11 DE G3/4 (BSPF) H 11.0 D06
32 h11 DE M27 ⫻ 2 J 11.0 D06

3. Determine thermowell material from Table 12.


Material = 316 Ti SST
Rosemount 114C = 316 Ti SST= SG
Table 12. DIN Material
Thermowell material (M) Material code
Molybdenum DIN 1.5415 EN 10273 MO
Chrome-Moly B-11 DIN 1.7335 EN 10273 CA
Chrome-Moly B-22 DIN 1.7380 EN 10273 CB
316 Ti SST DIN 1.4571 EN 10272 SG

4. Apply to Rosemount 114C model as shown below:


0.5 mm tip
Metric Weld-in Tapered
thickness

114C – M – XXXX – D – XX – 2 – XX – XXX – X – T01 – XXX

U PC M H IC BD

Resulting model code example: 114C-M-0065-D-DA-2-SG-135-K-T01-D03

52 Emerson.com/Rosemount
April 2017 Rosemount 114C

Figure 22. Weld Mounted Thermowell Drawings (Weld-in)

H. Head length U. Immersion length


∅ F_2, ∅ F_3, and H_1, refer to Table 13.

Table 13. DIN Weld Mounted Thermowells (Weld-in)(1)


Code D, welded (weld-in) style Thread length
Code

Head diameter “ ∅ F_2” Tip diameter “ ∅ F_3”


Process connection “H_1”

DA DIN 43772-4-7 (18 h7/3.5 mm bore/M14) 18 h7 (+0.000/–0.018 mm) 9 ±0.27 16


DB DIN 43772-4-7 (24 h7/7 mm bore/M18) 24 h7 (+0.000/–0.021 mm) 12.5 ±0.38 16
DC DIN 43772-4-7 (26 h7/7 mm bore/G1/2 or M20) 26 h7 (+0.000/–0.021 mm) 12.5 ±0.38 19
DD DIN 43772-4-7 (26 h7/9 mm bore/G1/2 or M20) 26 h7 (+0.000/–0.021 mm) 15 ±0.38 19
DE DIN 43772-4-7 (32 h11/11 mm bore/G3/4 or M27) 32 h11 (+0.000/–0.160 mm) 17 ±0.38 22

1. Dimensions are in inches (millimeters).

Emerson.com/Rosemount 53
Rosemount 114C April 2017

Welded thermowell drawings


Figure 23. Weld Mounted Thermowell Drawings (Socket Weld)(1)
Straight Tapered Stepped

S
N

A
A

U
d

B B B

A. Root diameter S. Socket size


B. Tip diameter U. Immersion length
H. Head length d. Bore diameter
N. Instrument connection t. Tip thickness

Table 14. Weld Mounted Thermowells (Socket Weld)(1)


Code W, welded mounting style
Code Socket size “ ∅ S” Root diameter “ ∅ A” Tip diameter “ ∅ B”
Process connection
AA / -in. pipe
3 4 1.05 (26.67) 0.75 (19) 0.50 (12.7)
AB 1-in. pipe 1.32 (33.4) 0.75 (19) 0.50 (12.7)
AC 11/4-in. pipe 1.66 (42.16) 0.75 (19) 0.50 (12.7)
AD 11/2-in. pipe 1.90 (48.26) 0.75 (19) 0.50 (12.7)

1. Dimensions are in inches (millimeters).

1. Total length = U + H.

54 Emerson.com/Rosemount
April 2017 Rosemount 114C

Figure 24. Weld Mounted Thermowell Drawings (Weld-in)(1)


H U

N B

A. Root diameter N. Instrument connection


B. Tip diameter U. Immersion length
H. Head length

Table 15. Weld Mounted Thermowells (Weld-in)(1)


Code D, welded mounting style
Code Root diameter “ ∅ A” Tip diameter “ ∅ B”
Process connection
AA / -in. pipe
3 4 1.050 (26.67) .748 (19)
AB 1-in. pipe 1.315 (33.40) .846 (21.5)
AC 11/4-in. pipe 1.660 (42.16) 1.043 (26.5)
AD 1 / -in. pipe
1 2 1.900 (48.26) 1.250 (31.75)
AE Custom Specified by design modifier “AXXX” Specified by design modifier “BXXX”

1. Dimensions are in inches (millimeters).

1. Total length = U + H.

Emerson.com/Rosemount 55
Rosemount 114C April 2017

Ordering information detail


Dimension units
Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

The Rosemount 114C Thermowell has the flexibility to be specified in either inches (E) or millimeters (M).

English units (inches)


If English is selected, all lengths will be in inches.

Metric
If metric is selected, all lengths will be in millimeters.

Immersion length (U)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

The immersion length normally refers to the length of the thermowell stem beginning underneath the process connection to the tip
of the thermowell. This length is typically specified by the process designer but the general rule is at least one-third or one-half the
pipe diameter. Thermowells longer than 42-in. will be required to have an internal pressure test (Q85) performed to ensure the
internal cavity integrity has not been compromised. Parallel thread thermowells have a U length that actually includes the process
threads thus requiring an extra 1-in. (25 mm) for min. U length.

Table 16. Minimum Immersion Length by Profile Style


Minimum length
Profile Minimum length
(parallel threads)
Straight 1-in. (25 mm) 2-in. (50 mm)
Tapered 1-in. (25 mm) 2-in. (50 mm)
Stepped 3 -in. (75 mm) 4-in. (100 mm)

Note
Long-length thermowells are those longer than 42-in. (1065 mm) and may be manufactured from two or three pieces of bar stock.

56 Emerson.com/Rosemount
April 2017 Rosemount 114C

Stem style
Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Straight style thermowells (1)


Straight style thermowells have the same diameter along the entire immersion length. They
present the largest profile to the process medium and have the highest drag force compared
to other styles with the same root diameter. Because of the large tip diameter, there is more
mass to heat which slows the thermal response of the measurement assembly. The minimum
immersion length (U) allowed with this profile is 1-in. (25 mm) except for parallel threaded thermowells that have a minimum
immersion of 2-in. (50 mm).

Tapered style thermowells (2)


Tapered style thermowells have an outside diameter that decreases uniformly from root to
tip. For the same root diameter, this design represents a good compromise between straight
and stepped thermowells. It’s drag will be less than a straight style, but greater than a
stepped style. The response time will be faster than a straight style and slower than a stepped
style. The two general forms of a tapered stem are uniform (tapered from root to tip) and non-uniform (straight portion followed by
tapered portion). Because of its profile shape, it is a good compromise for strength between the two other styles. It is the common
choice for high velocity flow applications where the flow forces typically are too great to use a stepped well. The tapered design has
faster response than the straight style offering an optimal balance of strength and response time factors. The minimum immersion
length (U) allowed with this profile is 1-in. (25 mm) except for parallel threaded thermowells that have a minimum immersion of 2-in.
(50 mm).

Stepped style thermowells (3)


Stepped style thermowells have two straight sections with the smaller diameter straight
section at the tip. For the same root diameter as a straight profile thermowell, this design has
less profile exposure to the flowing process and exhibits less drag force and quicker response
time due to the smaller mass at the tip. In general, stepped thermowells will have thinner
walls. By the geometry of its design, the stepped well has a higher natural frequency than the other styles with the same root
diameter, and is less susceptible to vibration induced failure. Since this design has less material at the tip, its considered the best
thermowell for fast time response. The minimum immersion length (U) allowed with this profile is 3-in. (75 mm) except for parallel
threaded thermowells that have a minimum immersion of 4-in. (100 mm).

Emerson.com/Rosemount 57
Rosemount 114C April 2017

Thermowell material
Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

The material of construction is typically the first consideration in choosing a thermowell for any given application. Three factors
affect the choice of material:
1. Chemical compatibility with the process media to which the thermowell will be exposed.
2. Temperature limits of the material
3. Compatibility with the process piping material to ensure solid, non-corroding welds and junctions.
It is important the thermowell conforms to the design specs of the pipe or vessel it will be inserted into to ensure structural and
material compatibility. The original process design most likely included temperature, pressure, and corrosive considerations as well
as cleaning procedures, agency approvals required, and conformance with codes or standards. Since an installed thermowell
essentially becomes part of the process, these original design considerations also apply to the thermowell and will drive the
thermowell material of construction and mounting type selection. International pressure vessel codes are explicit about the types of
materials and methods of construction allowed.

Table 17. Thermowell Materials

Code Thermowell material Flange material Code Thermowell material Flange material
316/316L SST 316/316L SST Alloy B3 Alloy B3
SC UNS S31600/S31603 UNS S31600/S31603 AB UNS N10001 UNS N10001
ASTM A479 ASTM A182 or A240 ASTM B335 ASTM B333

316/316L SST dual rated (NORSOK) 316/316L SST dual rated (NORSOK)(1) Alloy C-276 Alloy C-276
SD(1) UNS S31600/S31603 UNS S31600/S31603 AC UNS N10276 UNS N10276
ASTM A479 NORSOK M-630 MDS D57 ASTM A182 NORSOK M-630 MDS D54 ASTM B574 ASTM B462 or B575

304/304L SST 304/304L SST Alloy C-4 304/304L SST


SF UNS S30400/S30403 UNS S30400/S30403 AD UNS N06455 UNS S30400/S30403
ASTM A479 ASTM A182 or A240 ASTM B574 ASTM A182 or A240

316T i SST 316T i SST Alloy C-22 304/304L SST


SG UNS S31635 UNS S31635 AE UNS N06022 UNS S30400/S30403
ASTM A479 ASTM A182 ASTM B574 ASTM A182 or A240

316/316L SST with Tantalum sheath 316/316L SST with Tantalum sheath Alloy C-22 316/316L SST
UNS S31600/S31603 UNS S31600/S31603 AF UNS N06022 UNS S31600/S31603
ASTM A479 ASTM A182 or A240 ASTM B574 ASTM A182 or A240
SH(2)
Alloy 20 Alloy 20
Tantalum sheath UNS R05252 AG UNS N08020 UNS N08020
ASTM B473 ASTM B462 or B463

316/316L SST w / PFA coating 316/ 316L SST w / PFA coating Alloy 400 Alloy 400
SJ UNS S31600/S31603 UNS S31600/S31603 AH UNS N04400 UNS N04400
ASTM A479 ASTM A182 or A240 ASTM B164 ASTM B564 or B127

304/304L SST with PTFE coating 304/304L SST with PTFE coating Alloy 400 304/304L SST
SK UNS S30400/S30403 UNS S30400/S30403 AJ UNS N04400 UNS S30400/S30403
ASTM A479 ASTM A182 or A240 ASTM B164 ASTM A182 or A240

310 SST 310 SST Alloy 600 Alloy 600


SL UNS S31008 UNS S31008 AK UNS N06600 UNS N06600
ASTM A479 ASTM A182 or A240 ASTM B166 ASTM B564 or B168

321 SST 321 SST Alloy 600 304/304L SST


SM UNS S32100 UNS S32100 AL UNS N06600 UNS S30400/S30403
ASTM A479 ASTM A182 or A240 ASTM B166 ASTM A182 or A240

Carbon steel
Carbon steel Molybdenum Molybdenum
UNS K03504
CS UNS K03504 MD UNS R03600 UNS R03630
ASTM A105, A216 GR WCB, or A515 GR
ASTM A105 ASTM B387 ASTM A204 or B386
70

Chrome-Moly Grade F-11


Titanium grade 2 Titanium grade 2 Chrome-Moly Grade B-11
UNS K11572
TT UNS R50400 UNS R50400 CA UNS K11797
ASTM A182 GR F-11 CL2 or A387
ASTM B348 GR 2 ASTM B381 GR 2 ASTM A739 GR B-11
GR11 CL2

58 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 17. Thermowell Materials

Code Thermowell material Flange material Code Thermowell material Flange material
Chrome-Moly Grade F-22
Super duplex Super duplex Chrome-Moly Grade B-22
UNS K21590
DS UNS 32750 UNS 32750 CB UNS K21390
ASTM A182 GR F-22 CL3, A217 GR
ASTM A479 GR F53 ASTM A182 GR F53 or A240 ASTM A739 GR B-22
WC9, or A387 GR22 CL2

Super duplex (NORSOK) Duplex 2205 (NORSOK)


Duplex 2205 Duplex 2205
UNS 32750 UNS 31803
DU UNS 31803 UNS 31803 DT(1)
ASTM A479 GR F53 NORSOK ASTM A182 GR F53 NORSOK M-630
ASTM A479 GR F51 ASTM A182 GR F51or A240
M-630 MDS D57 MDS D54

Chrome-Moly Grade F-91 Duplex 2205 (NORSOK) Duplex 2205 (NORSOK)


Chrome-Moly Grade F-91
UNS K90901 UNS 31803 UNS 31803
CC UNS K90901 DV(1)
ASTM A182 GR F-9, A217 GR C12A, or ASTM A479 GR F51 NORSOK ASTM A182 GR F51 NORSOK M-630
ASTM A182
A387 GR 91 CL2 M-630 MDS D47 MDS D44

Molyboenum Molyboenum
Nickel 200 Nickel 200
UNS R03600 UNS R03630
NK UNS N02200 UNS N02200 MO
ASTM B387 ASTM A204 or B386
ASTM B160 ASTM B162 or B564
DIN 1.5415 EN 10273 DIN 1.5415 EN 10222-2

1. Material supplier qualified per NORSOK M-650; material qualified per NORSOK M-630.
2. Sheath thickness = 0.01-in. (0.38 mm).

NORSOK
Rosemount 114 Thermowell ordered with NORSOK will have raw material from a NORSOK M-650 approved supplier, material
approver per NORSOK M-630 datasheet, and flange welding qualified to NORSOK M-601. The NORSOK material will also meet
requirements of NACE MR0175/ISO 15156.
Q8 should be ordered to receive the MTR. The MTR will come with an M-650 Qualification Test Record (QTR) cover sheet. Additional
testing required by the M-630 datasheet will be included in the MTR.
Some of the required testing for NORSOK Duplex in addition to ASTM requirements;
 Micrographic examination at 400 to 500⫻ magnification
 Ferrite content analysis according to ASTM E 562 or by image analysis according to ASTM E 1245. Ferrite content shall be within
35–55 percent.
 Charpy V-notch testing according to ASTM A 370 at –46 °C. Minimum absorbed energy shall be 45 J average and 35 J single.
 Corrosion testing according to ASTM G 48 Method A. No pitting at 20⫻ magnification; Weight loss shall be less than
4 g/m2.

Full details of the material requirements can be found in the ASTM and NORSOK M-630 standards.

Emerson.com/Rosemount 59
Rosemount 114C April 2017

Head length (H)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Head length is the distance from the bottom of the process connection to the top of the thermowell. Each style has a minimum head
length; the length specified must meet or exceed that minimum. It is shown below for all process connection styles.

Note
The industry standard minimum head length for flanged and Van Stone thermowells with connections under Class 900 (ASME B16.5)
or PN 100 (EN 1092-1) is 2.25-in. (60 mm).

Table 18. Recommended Minimum Head Length(1)


Process connection Minimum head length (H)
Threaded
1.75 (45)
Welded

1. Dimensions are in inches (millimeters).

Table 19. Recommended Minimum Head Length by Connection Class for ASME B16.5(1)
Connection size Connection class
Flanged 150 300 400/600 900/1500 2500
3 4 / N/A 1.75 (45) N/A N/A N/A
1 1.75 (45) 2.00 (50) 2.00 (50) 2.50 (65) N/A
11/2 1.75 (45) 2.00 (50) 2.00 (50) 2.50 (65) 3.00 (75)
2 1.75 (45) 2.00 (50) 2.00 (50) 2.75 (70) 3.25 (80)
3 2.00 (50) N/A N/A N/A N/A
4 2.00 (50) N/A N/A N/A N/A
6 2.00 (50) N/A N/A N/A N/A
Flanged with RTJ 150 300 400/600 900/1500 2500
3 4 / N/A 2.00 (50) N/A N/A N/A
1 1.75 (45) 2.00 (50) 2.00 (50) 2.50 (65) N/A
11/2 2.00 (50) 2.00 (50) 2.00 (50) 2.50 (65) 3.25 (80)
2 2.00 (50) 2.00 (50) 2.00 (50) 2.75 (70) 350 (85)
3 2.25 (60) N/A N/A N/A N/A
4 2.25 (60) N/A N/A N/A N/A
6 2.25 (60) N/A N/A N/A N/A

60 Emerson.com/Rosemount
April 2017 Rosemount 114C

Table 19. Recommended Minimum Head Length by Connection Class for ASME B16.5(1)
Connection size Connection class
Van Stone 150 300 400/600 900/1500 2500
1 1.75 (45) 1.75 (45) 1.75 (45) 2.00 (50) 2.25 (60)
11/2 1.75 (45) 1.75 (45) 1.75 (45) 2.25 (60) 2.75 (70)
2 1.75 (45) 1.75 (45) 2.00 (50) 2.75 (70) 3.25 (80)
Van Stone with RTJ 150 300 400/600 900/1500 2500
1 1.75 (45) 1.75 (45) 2.25 (60) 2.25 (60) 2.50 (65)
11/2 1.75 (45) 2.00 (50) 2.00 (50) 2.50 (65) 3.00 (75)
2 1.75 (45) 2.00 (50) 2.25 (60) 3.00 (75) 3.50 (90)

1. Dimensions are in inches (millimeters).

Table 20. Recommended Minimum Head Length by Connection Class for EN 1092-1(1)
Connection size Connection class
Flanged PN 2.5/6 PN 10/16 PN 25/40 PN 63 PN 100
DN 20 40 45 50
DN 25 40 45 50
DN 40 40 45 50
DN 50 40 45 55 60
DN 65 40 45 50 55 60
DN 80 40 45 50 55 60
DN 100 40 45 50 55 60

1. Dimensions are in millimeters.

Instrument connection
Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Thread Specification Internal thread


/ –14 NPT
1 2 SAE-AS 71082
/ –14 NPSM
1 2 ASME B1.20.1, 8 threads minimum
/ –14 NPT
3 4 SAE-AS 71082
M18 ⫻ 1.5p
M20 ⫻ 1.5p
M24 ⫻ 1.5p BS 3643
M27 ⫻ 2p
M14 ⫻ 1.5p
G1/2-in. (BSPF) ISO 228/1 (BS 2779)
G3/4-in. (BSPF) ISO 228/1 (BS 2779)

Emerson.com/Rosemount 61
Rosemount 114C April 2017

Sensor/thermowell assemble to options (XT, XW)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

XT
This option is selected when a Rosemount 214C Sensor is ordered with the Rosemount 114C Thermowell. This ensures the sensor is
threaded into the thermowell, but only hand tightened.

XW
This option is selected when a Rosemount 214C Sensor is ordered with the Rosemount 114C Thermowell. This ensures the sensor is
threaded into the thermowell and torqued for a process-ready installation.

Extended product warranty (WR3, WR5)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

The extended product warranty options are available in three or five year coverage plans. In the model string, order option codes
WR3 for a three year extended warranty or WR5 for a five year warranty. This coverage is an extension of the manufacturer's limited
warranty and states that the goods manufactured or services provided by seller will be free from defects in materials or workmanship
under normal use and care until the expiration of the applicable warranty period.

62 Emerson.com/Rosemount
April 2017 Rosemount 114C

Thermowell calculation (R21)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

The ASME PTC 19.3TW-2016 is internationally recognized as a mechanical design standard yielding reliable thermowell service in a
wide range of temperature measurement applications. It includes evaluation of stresses applied to a barstock thermowell as installed
in a process based on the design, material, mounting method, and process conditions. The documentation provided will detail the
process information, thermowell geometry, and comprehensive calculation analysis. It will also provide an acceptable or
unacceptable statement based on the analysis.
There are four quantitative criteria in ASME PTC 19.3 TW-2016 for a thermowell to be found acceptable for a particular set of process
conditions:
 Frequency Limit: the resonant frequency of the thermowell must be sufficiently high so that destructive oscillations are not
excited by the fluid flow.
 Dynamic Stress Limit: the maximum primary dynamic stress must not exceed the allowable fatigue stress limit. If the design
requires that the thermowell pass through the in-line resonance to get to the operating conditions, there is an additional fatigue
check at resonance.
 Static Stress Limit: the maximum steady-state stress on the thermowell must not exceed the allowable stress, as determined by
the Von Mises criteria.
 Hydrostatic Pressure Limit: the external pressure must not exceed the pressure ratings of the thermowell tip, shank, and flange
(or threads).

In addition, the suitability of the thermowell material for the process environment must be considered. This means the designer must
evaluate how corrosion and erosion affects the thermowell as well as how exposure to the process conditions affects material
properties.
For detailed information about this standard, refer to the Thermowell Calculations White Paper. Emerson advises that all thermowells
should have a wake frequency calculation performed to ensure they are suitable for the process conditions in their application.
Emerson assumes that the customer has either done their own calculations or understands the risks of not having calculations done if
this option is not requested.

NACE approval (Q35)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

This option certifies that thermowell materials used are compliant to NACE MR0175/ISO 15156 and NACE MR0103. The material
certification provided will list compliance to the referenced standard.

Material code NACE certified material Material code NACE certified material
SC 316/316L Dual Rated AK Alloy 600
SF 304/304L Dual Rated CA Chrome-Moly Grade B-11/F-11 Class II
SL 310 SST CB Chrome-Moly Grade B-22/ F-22 Class III
SM 321 SST
AB Alloy B3
AC Alloy C-276
AG Alloy 20
AH Alloy 400

Emerson.com/Rosemount 63
Rosemount 114C April 2017

PMI testing (Q76)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Positive Material Identification (PMI) is a test that verifies the thermowell material is as specified by the Rosemount 114C model code.
X-ray/radiograph fluorescence (XRF) is used to provide elemental analysis in a nondestructive manner. The certificate will provide
PMI results in comparison with the applicable material standards for each individual thermowell and state the reference standard.
Two points are provided on flanges. All other thermowell components (including welds) will have a single point. XRF will not detect
carbon in steels. PMI can be marked on the thermowell by choosing option R40. Due to type of technology used carbon steel material
is exempt from this testing.

Material certification (Q8)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Material certificate and traceability in accordance with EN 10204 Type 3.1 Inspection Certificate. The certificate provided will
document the heat code, chemical analysis, and testing required by material standards.

Low temperature Charpy test (M01)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Test is performed in accordance with ASTM A370 and report will be include in the Material Traceability Report (Q8). This report must
be ordered if any documentation is required. Charpy test will be done to check toughness of the raw bar and flange material used for
the construction of the thermowell. The table below shows the material available with the option, test temperature, and acceptance
criteria.

Material Material codes Charpy temperature Acceptance impact value


DS – Super duplex
DT – Super duplex (NORSOK) Average: 45 J (33 ft-lb)
Duplex –58 °F (–50 °C)
DU – Duplex Minimum: 35 J (26 ft-lb)
DV – Duplex (NORSOK)
SC – 316/316L SST
SD – 316/316L SST (NORSOK)
SF – 304/304L
SG – 316 Ti Average: 60 J (44 ft-lb)
300 Series SST –321 °F (–196 °C)
SH – 316/316L with tantalum sheath Minimum: 55 J (41 ft-lb)
SJ – 316/316L with PFA coating
SK – 304/304L with PTFE coating
SM – 321 SST

64 Emerson.com/Rosemount
April 2017 Rosemount 114C

Ultrasonic material test (M02)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Ultrasonic examination will be done to check quality of the raw bar and flange material used for thermowell construction. The testing
shall be performed in accordance with procedures specified in ASTM A388 by a Level 2 inspector. Calibration and acceptance criteria
shall be per API 6A.

Surface finish certification (Q16)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Thermowell surface finish is typically done to remove all the burrs and sharp edges which smooths the thermowell stem surface. The
Rosemount 114C comes with a standard surface finish of T32 μ in. CLA N6 (0.8 μm Ra) or better. This option provides a certificate
that documents the maximum surface finish reading for stem and flange (when applicable) and a pass/fail statement. Improved
surface finish options are also available for the Rosemount 114C (see options R14 and R20).

Surface finish <Ra 0.3 μm (12 μin) (R14)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Improves surface finish to be less than Ra 0.3 μm. An improved surface finish will increase corrosion resistance and make the
thermowell easier to clean. This is common in sanitary applications.

Electropolish (R20)
Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

The electropolish process uses a combination of electrical current and chemicals to improve the surface finish. The surface will
appear shiny and polished. It can have an advantage over mechanical polishing because there is no cold work involved that can lead
to scratches, strains, metal debris, and embedded abrasives on the surface. An improved surface finish will increase corrosion
resistance and make the thermowell easier to clean. This is common in sanitary applications.

Emerson.com/Rosemount 65
Rosemount 114C April 2017

External hydrostatic pressure test (Q5)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table

Thermowells are tested at room temperature for 10 minutes. Water is certified to have a chlorine content of less than 30 ppm. The
certificate will document the chlorine content, hydrostatic test pressure level, duration, and test results. The pressure rating (in psi)
for the different thermowell mounting styles is given below.

Flanged and Van Stone


Hydrostatic pressure test levels are in accordance with ASME B16.5. When the table below and the standard conflict, the standard
shall govern.
Thermowell material (psi)
Flange class (lb)
NK AH SA through SM, AD, AE, AF, AJ, AL CS AG, AK, CA, AB, AC, CB, CC, DU, DS
150 300 350 425 450 450
300 725 900 1100 1125 1125
600 1450 1800 2175 2225 2250
1500 (900) 3600 4500 5400 5575 5625
2500 6000 7500 9000 9275 9375

DIN flanged thermowells


Table 21. External Pressure Test–DIN
DIN flanged thermowells
Nominal pressure (bar) Test pressure (bar)
16 40
40 100
100 250
Test to 2.5⫻ nominal pressure rating

Threaded thermowells
1500 psi

Internal hydrostatic pressure test (Q85)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

This test is performed at room temperature for a minimum of 10 minutes to 3000 PSI. The water used here is certified to ensure a
chloride content of less than 30 PPM. The certificate provided will document the chloride content, hydrostatic test level, duration,
and results. Thermowells longer than 42-in. will be required to have an internal pressure test (Q85) performed to ensure the internal
cavity integrity has not been compromised.

66 Emerson.com/Rosemount
April 2017 Rosemount 114C

Canadian registration number (Q17)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Any pressure vessel, piping system, or fitting used in Canada is required by law to have a CRN (Canadian Registration Number). This
ensures all pressure vessels, piping systems, and fittings are built under appropriate quality control programs. This CRN is for all
Canadian provinces but the end destination province still needs to be known during the order process.

Material code CRN approved material


SC 316/316L Dual Rated
SF 304/304L Dual Rated
SH 316 SST with Tantalum Sheath
SJ 316L SST with PFA Coating
SK 304 SST with PTFE Coating
SL 310 SST
SM 321 SST
AB Alloy B3
AC Alloy C-276
AG Alloy 20
AH Alloy 400
AJ Alloy 400 (with 304 SST Flange)
AK Alloy 600
AL Alloy 600(with 304 SST Flange)
CA Chrome-Moly Grade B-11/F-11 Class II
CB Chrome-Moly Grade B-22/F-22 Class III
CC Chrome-Moly Grade F-91
CS Carbon Steel (A-105)
TT Titanium Grade 2
DU Duplex 2205 Grade F51

Dye penetration test (Q73)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Dye or liquid penetration testings are performed by ASME Level II or III trained inspectors. These tests are all done in accordance to
ASME Section V, Article6 with an acceptance criteria per ASME Section III, Div 1 NB-2546. The certificate will document the
inspectors name, dye penetration acceptance criteria, and test result.

Emerson.com/Rosemount 67
Rosemount 114C April 2017

Wall thickness test (Q83)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Ultrasonic examination performed to check stem wall thickness. Min and max wall thickness measurements shall be recorded
25 mm or 1-in. from the thermowell tip. Bore position should be 10 percent of minimum stem wall thickness at nominal dimensions
(see image below).

Special cleaning (Q6)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Special cleaning for oxygen/special service to be performed in accordance to ASTM G93. The procedure to be qualified using ASTM
G93 Type II quantitative tests. The documentation provided for this test will have a compliance statement to ASTM G93. All cleaned
thermowells will come in a sealed plastic bag to prevent contamination. Not available with carbon steel or any coated material.

Thermowell markings (R40)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

This options provides the ability to have certain test markings on the thermowell. Below are the tests available for this option.
 Q5 — external pressure tests the values and units
 Q76 — PMI will be marked on the head length portion of the thermowell and on the top of the flange if applicable

X-ray/radiograph test (Q81)


Back to Flanged ordering table

This test involves performing an X-ray/radiograph on the weld joints to examine for any internal imperfections and is only available
on full penetration flanged thermowells. Testing is done in accordance to ASME Section VIII Div 1 per UW51 and conducted by a Level
2 Inspector. The certificate provided with this option will document the results.

68 Emerson.com/Rosemount
April 2017 Rosemount 114C

Spherical tip (R60)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Radius of spherical tip (B) is the same as the specified thermowell tip radius. Thermowell will still maintain specified “U” length.

MAX = t+ 3.5
MIN = t

Stainless steel plug and chain (R06)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Welded ordering table

The plug and chain are made from stainless steel. This plug is used to protect the thermowell threads when a sensor isn't installed. It
also keeps elements such as rain, dust, and dirt out of the thermowell.

Brass plug and chain (R23)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Welded ordering table

The plug and chain are made from brass. This plug is used to protect the thermowell threads when a sensor isn't installed. It also
keeps elements such as rain, dust, and dirt out of the thermowell.

Emerson.com/Rosemount 69
Rosemount 114C April 2017

Vent hole (R11)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

The vent hole allows for the venting of a thermowell. Vent or weep holes are often used to prevent gas buildup in certain applications.
This option is useful in applications where gas build up is a concern. Process fluid leakage from the vent hole is an indicator of
thermowell failure.

Flange face – concentric serrations (R09)


Back to Flanged ordering table
Back to Van Stone ordering table

This option changes the flange face so it has concentric serrations covering the wetted portion of the flange raised face. It is installed
with an inside bolt circle (IBC) gasket/ring gasket, which extends to and is centered by the bolts. This flange face is designed per the
ASME B16.5 standard.

Figure 25. Installation Components


A

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

70 Emerson.com/Rosemount
April 2017 Rosemount 114C

Flange face – flat (R10)


Back to Flanged ordering table

This option changes the flange face so it has no raised section on the wetted portion of the flange face. The flat face is finished with
spiral serrations. This style is frequently used where the mating flange is made from a casting or fragile material. It can be installed
with ring gaskets or full face gaskets that extend past the bolt holes. This flange face is designed per the ASME B16.5 standard.

Figure 26. Installation Components


A
B
C

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

Raised face – Type B2 (R15)


Back to Flanged ordering table

This option provides a smoother finish to the flange face compared to the standard Type B1 flange face.

Emerson.com/Rosemount 71
Rosemount 114C April 2017

Figure 27. Installation Components


A
B
C

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

Flange face – RTJ (R16)


Back to Flanged ordering table
Back to Van Stone ordering table

This option changes the flange face so it has a ring type joint (RTJ). The RTJ flange face is common for high pressure applications using
Class 600 flanges or higher. Both mating flanges have grooves that can accept a RTJ gasket which is usually made of solid metal. This
flange face is designed per the ASME B16.5 standard.

Figure 28. Installation Components


A
B
C

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

72 Emerson.com/Rosemount
April 2017 Rosemount 114C

Flange face – groove, Type D (R18)


Back to Flanged ordering table
Back to Van Stone ordering table

Type C “tongue” will mount to Type D “groove”.

Figure 29. Installation Components

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

Flange face – tongue, Type C (R19)


Back to Flanged ordering table
Back to Van Stone ordering table

Type C “tongue” will mount to Type D “groove”.

Emerson.com/Rosemount 73
Rosemount 114C April 2017

Figure 30. Installation Components

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

Flange face – spigot, Type E (R24)


Back to Flanged ordering table
Back to Van Stone ordering table

Type E “spigot” will mount to type F “recess”.

Figure 31. Installation Components

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

74 Emerson.com/Rosemount
April 2017 Rosemount 114C

Flange face – recess, Type F (R25)


Back to Flanged ordering table
Back to Van Stone ordering table

Type E “spigot” will mount to type F “recess”.

Figure 32. Installation Components

A. Thermowell
B. Bolt/washers
C. Ring gasket
D. Nozzle and mating flange
E. Process

Thermowells with wrench flats (R37)


Back to Threaded ordering table

This option only applies to threaded thermowells made from exotic materials. By default, these thermowells are made with two
wrench flats; this option must be selected to get hex (6) wrench flats.

Figure 33. Wrench Flats


Standard Option R37

Emerson.com/Rosemount 75
Rosemount 114C April 2017

Table 22. Exotic Materials


Code Material Code Material Code Material
Alloy 400
AB Alloy B3 AJ NK Nickel 200
(with3 04/304L SST flange)
AC Alloy C-276 AK Alloy 600 TT Titanium Grade 2
Alloy C-4 Alloy 600
AD AL DS Super duplex SST Grade F-53
(with 304/304L SST flange) with 304/304L SST flange)
Alloy C-22 Super duplex SST Grade F-53
AE MO Molybdenum DT
(with 304/304L SST flange) (NORSOK)
Alloy C-22 Chrome-Moly Grade B-11/F-11
AF CA DU Duplex 2205 Grade F-51
(with 316/316L SST flange) Class II
Chrome-Moly Grade B-22/ F-22
AG Alloy 20 CB DV Duplex 2205 Grade F-51 (NORSOK)
Class III
AH Alloy 400 CC Chrome-Moly Grade F-91

Root diameter (A0XX)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Larger root diameters will provide greater strength. Changing the root diameter is helpful when designing a thermowell to pass wake
frequency calculations.
Guidelines on specifying design modifiers based on the stem profile are as follows:
 Straight – only root diameter (Axxx) should be specified
 Tapered – both root (Axxx) and tip diameter (Bxxx) must be specified
 Stepped – if root diameter (Axxx) only is specified, the tip will be standard 0.5-in diameter; if tip diameter (Bxxx) is ordered, root
diameter (Axxx) must also be specified

76 Emerson.com/Rosemount
April 2017 Rosemount 114C

Tip diameter (B0XX)


Table 23. Sample Root Diameters
Code Dimension (E) Code Dimension (M)
A040 0.4-in. A100 10 mm

A045 0.45-in. A110 11 mm

A100 1.00-in. A205 20.5 mm

A310 3.10-in. A790 79 mm

A315 3.15-in. A800 80 mm

Back to Threaded ordering table


Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Smaller tip diameters will improve time response. Changing the tip diameter is helpful when designing a thermowell to pass wake
frequency calculations.
Guidelines on specifying design modifiers based on the stem profile are as follows:
 Straight – only root diameter (Axxx) should be specified
 Tapered – both root (Axxx) and tip diameter (Bxxx) must be specified
 Stepped – if root diameter (Axxx) only is specified, the tip will be standard 0.5-in. diameter; if tip diameter (Bxxx) is ordered, root
diameter (Axxx) must also be specified

Table 24. Sample Tip Diameters


Code Dimension (E) Code Dimension (M)
B040 0.4-in. B120 12 mm
B045 0.45-in. B130 13 mm

B100 1.00-in. B205 20.5 mm

B175 1.75-in. B450 45 mm

B180 1.80-in. B460 46 mm

Emerson.com/Rosemount 77
Rosemount 114C April 2017

Bore diameter (d0X)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Bore diameter (d) can be selected to accommodate different temperature sensor sizes. Time response is improved when the sensor
and thermowells have a tighter fit.
d

Table 25. Available Bore Diameters


Code Dimension Code Dimension (M)
D01 0.276-in./7.0 mm D04 0.385-in./9.8 mm
D02 0.260-in./6.6 mm D05 0.354-in./9 mm

D03 0.138-in./3.5 mm D06 0.433-in./11 mm

Tip thickness (t0X)


Back to Threaded ordering table
Back to Flanged ordering table
Back to Van Stone ordering table
Back to Welded ordering table

Tip thickness (t) is specified as the minimum thickness and measured from the top of the gun drill web as shown in the figure below

Table 26. Available Tip Thicknesses


Code Dimension
T01 0.197-in./5.0 mm

T02 0.236-in./6.0 mm

T03 0.252-in./6.4 mm

78 Emerson.com/Rosemount
April 2017 Rosemount 114C

Lap flange material for Van Stone design (C0X)


Back to Van Stone ordering table

This option is only available when the Van Stone (V) mounting configuration is selected. By default, a Van Stone thermowell comes
with a carbon steel A105 lap flange. These options give the choice of having the thermowell ordered without a flange, with a
316/316LSST flange, or with a flange of similar material as the thermowell stem. Below are some model string examples of the
standard offering and options for reference:
Example model: 114CE0030VAA2SC032A – carbon steel A105 lap flange with 316/316L SST thermowell stem provided (standard)

Example model: 114CE0030VAA2SC032AC01 – no lap flange, only thermowell stem provided

Example model: 114CE0030VAA2SC032AC02 – changes default carbon steel A105 lap cover flange to 316/316LSST flange

Example model: 114CE0030VAA2SC032AC03 – changes default cover flange to match thermowell stem material

Note
Coatings do not apply to lap flange.

Emerson.com/Rosemount 79
Our offering:

Pressure Level
Measurement Measurement

Temperature Flow
Measurement Measurement

Marine
Gas
Measurement &
Analysis
Analytical

Liquid Flame and Gas


Analysis Detection

Tank Wireless
Gauging Infrastructure

Acoustic
&
Discrete

www.high-accuracy.com
Rosemount 114C Product Data Sheet
00813-0200-4952, Rev DB April 2017

Global Headquarters
Emerson Automation Solutions
6021 Innovation Blvd.
Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
RFQ.RMD-RCC@Emerson.com

North America Regional Office


Emerson Automation Solutions
8200 Market Blvd.
Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
RMT-NA.RCCRFQ@Emerson.com

Latin America Regional Office


Emerson Automation Solutions
1300 Concord Terrace, Suite 400
Sunrise, FL 33323, USA
+1 954 846 5030
+1 954 846 5121
RFQ.RMD-RCC@Emerson.com

Europe Regional Office


Emerson Automation Solutions Europe GmbH
Neuhofstrasse 19a P.O. Box 1046
CH 6340 Baar
Switzerland
+41 (0) 41 768 6111
+41 (0) 41 768 6300
RFQ.RMD-RCC@Emerson.com Linkedin.com/company/Emerson-Automation-Solutions

Asia Pacific Regional Office Twitter.com/Rosemount_News


Emerson Automation Solutions Asia Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461 Facebook.com/Rosemount
+65 6777 8211
+65 6777 0947 Youtube.com/user/RosemountMeasurement
Enquiries@AP.Emerson.com

Middle East and Africa Regional Office Google.com/+RosemountMeasurement


Emerson Automation Solutions
Emerson FZE P.O. Box 17033 Standard Terms and Conditions of Sale can be found on the Terms and
Jebel Ali Free Zone - South 2 Conditions of Sale page.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
Dubai, United Arab Emirates Complete Point Solution, Rosemount, and Rosemount logotype are
+971 4 8118100 trademarks of Emerson.
+971 4 8865465 NACE is a registered trademark of NACE International.
All other marks are the property of their respective owners.
RFQ.RMTMEA@Emerson.com © 2017 Emerson. All rights reserved.

You might also like