MAKING MODERN LIVING POSSIBLE
VLT® AutomationDrive
The VLT* AutomationDrive isa single drive concept that covers
which isa major b
Perfect
= Industrial automation
= High dynamic applications
~ Safety installations
snefit in commissioning, operating
‘The modular open-technology
platform that VLT® AutomationDrive
isbuilt on makes it exceptionally
‘adaptable and programmable.
Its configurable, user-friendly inter-
face supports local languages and
letters.
Pluggable options
The drive solution can be adapted to
any application due to the flexible
option structure. Numerous options
are available and can be mounted
and tested from factory or be plugged
in later for change-over or upgrade.
Adapts to the future
‘The modular concept of VLT* Auto-
mationDrive makes it highly adapt-
able - also to future features and
‘options. Modularity offers the benefit
of buying on a need-to-have basis
without losing future possibilities.
n entire rant
Hot pluggable Control Panel
The Local Control Panel (LCP) can be
plugged in directly or connected
‘through a cable for remote commis-
sioning, The LCP can be disconnected
during operation and replaced with a
blind cover. Settings are easily trans-
ferred via the LCP from one drive to
another or from a PC to a drive with
the VLT* Set-up Software MCT 10.
‘Awarded
VLT* AutomationDrive has received
the Frost & Sullivan award for innova-
tion and the iF Design Award for its
user friendliness.
Power range
3 X 200 ~ 240 Vevwnsnnns0.25~37 KW
3 x 380 ~ 480/300 V.......0.37 ~ 800 kW
3X 525 ~ 600 Vevwnnn0.75 = 75 KW
3X 535 ~ 690 Vivwnnsnen 37 ~ 1200 KW
Normal overload. 45 ~ 1400 kW
“Ambient temperature 50°C without derating
‘Avalable in 1 00,20, 21, 54,55
‘3nd 66 enclosures
Resistant to wear an teat
Less need for cooling or ovesizing
‘Suitable for harsh and wash down areas
Low lifetime cost
Back-channel cooling for EandF Prolonged ifetime of electronics
Plug-and Ply technology Fa5y upgrade and change over
‘Awarded contol panel User-friendly
Intutive VT interface Savestime
Pluggable cage lamp connectors asy connection
Exchangeable languages User riendly
Intelligent warning systems
‘Smart Logic Contr
Advanced plug-in features
Safestop
‘STO: Safe Torque OF (IEC 61800-5-2)
Inteligent heat management
Facts about our products
‘Waring before controled stop
Reduces need for PLC capacity
Easy commissioning
Safety cat 3 (EN 954-1), PL d (SO 13845-),
Stop cat 0 (EN 60204-1)
SIL 2(1C 61508)
SILCL2 EC 62061)
‘Excess heat effectively removed
vrOptions
The following options ae available:
Fieldbus options
= MCA 101 Profibus
= MCA 104 DeviceNet
= MCA 105 CanOpen
= MCA 113 Profibus VLT* 3000
protocol converter
= MCA 114 Profibus VLT* 5000
protocol converter
= MCA 120 PROFINET
= MCA 121 Ethernet IP
= MCA 122 Modbus TCP
UO and feedback options
= MCB 101 General Purpose VO
= MCB 102 Encoder
= MCB 103 Resolver
= MCB 105 Relay
= MCB 107 24V input option for
control voltage
MCB 113 Extended Relay Card
= MCB 114 VLT* Sensor Input
Safety options
= MCB 108 Safety PLC interface
(BC/DC converter)
= MCB 112 ATEX-PTC Thermistor Card
Brake chopper (IGBT) option
Connected to an external brake
resistor, the built-in brake chopper
limits the load on the intermediate
circuit in the case the motor acts as a
generator,
Motion Control Options
= MCO 305 Programmable Motion
Controller
MCO 350 Synchronizing Controller
MCO 351 Positioning Controller
MCO 352 Center Winder Controller
Power options
= Brake resistors
= Sine-Wave Filters
= dU/dt Filters
= Harmonic Filters (AHF)
Specifications
i
Supply woltage
‘upphy frequency
Tue Power Factor)
Displacement Power Factor (cos) near unity
Switching on Input supply L112, 3
200 -240V =10%
F301; 300 460 210%
FE 302: 380 So0V 10% 525 -60DV 210%
525- 690V 510%
sovso He
(092 nominal trated load
b099)
Maximum 2timesimio.
EE)
‘Ourputvotage
urpurfequency
Switching on ourput
Ramp times
‘0 100% of upply vokage
F301: 02 1000H2(025~75 kW)
FE302: 0° 10002 (025 73)
8-a000(90-1200K0)
(0-300 He Fux mode)
Unites
3600s4¢
Not: 60 cunt cone provided fr | minute Higher oad aig is achieved by overizng the dri.
Digital inputs
Programmable cial nputs
Loaic
Voltage level
F301: 4{5)/FC 302416),
PNP or NPN
0-24v0C
Note One/two dtl inputs can be programmed as digtal output for 301/302
‘Analogue puts
Modes
Voltage level
Currentlove
2
Volage orcurent
F301: 0t0 +10V/FC302:-10t0-H10V (saleable)
(0/420 mA (scaleable)
Programmable puiteencoderinputs
‘Voltage eve
FC 301:1/FC 3022
(0 24V DC PNP postive lgie)
re
Programmable digtal/pule outputs
‘Voltage level at cgtalfrequency output
FC 301:1/FC 3022
o-2av
ors
Programmable analogue outputs
Currentrange
0/4-20mA,
Programmable lay outputs
C301 1/FC3022
Max motor able lengths
301: 50 m/FC302:150m (reenedlarmoured)
C301: 75 m/ Fe sa2-300m (ansreened/urarmouted)
“More analogue and gta! inpusourputscan beodded by options
Other accessories
= IP 21/NEMA1 Kit
(convert IP 20 to IP 21)
= PROFIBUS adapter
= Sub-D9 Connector
Decoupling plate for
fieldbus cables
USB connection cable to PC
Panel Through option
LCP panel mounting kit
Mains disconnect option
High power options
= IECEmergency stop with
Safety Relay
Safety Stop with Safety Relay
AI Filters
NAMUR terminals
RCD
IRM
Mains shielding
= Regen terminals
Please see the VET High Power Drive Selection
(Gide forthe complete range of options
‘ars an acco eeonabiy lr some corn coum, bashes an lets rele Oaoss ares he ge a Tapas wine aco Ths aba apples
enugeaoaey ower bea