JEETARP
BENDER Group
ELECTRICAL SAFETY
POWER QUALITY
ENERGY MANAGEMENT
ectarp
“Graphene”
Designed For nttigen
Graphene Power Quality Meter -—GPOM144
Power Quality Meter and Analyzer
ferent s
(eer een eres eee
Seer ecus aces
SRC acu g
Measure’s harmonics up to 63rd Harmonic (including THD, TDD)
www.eetarp.comGraphene Power Quality Meter -GPQM144
Power Quality Meter and Analyzer
Device Features
Product Description
‘The GPOM44 (244 x244 mm) is a power quality
analyzer and part of the Graphene-Meter-Series.
‘The combination of high accuracy and an internal
8GB memory allows to perform complex
measurements and subsequently to analyze the
electrical system's quality in detail
The device measures currents, voltages, energy
consumption, power, and individual harmonics to
assess the power quality according to DIN EN
50360. The accuracy of active energy
measurements corresponds to class 0.2 S (DIN EN
62053-22)
‘The GPOMa44 is suitable for 2-, 3- and 4-wire
systems, including TN-, TT-, and IT-Systems.
Standard industrial communication interfaces like
Modbus RTU, Modbus TCP/IP, BacNet, Dis/DOs
ensure smooth communication with any other
system,
Typical Applications
Electrical Safety | Power Quality | Energy Management
Class-A power quality analyzer
In accordance with DIN EN 50360
Accuracy class according to IEC 62053-22: 0.2S
High resolution Failure Record with 1024
point/cycle
Colorful LCD interface
Failure diagnose location, 20s for transient
disturbance record
Supports Failure Diagnose: support voltage sag
source, harmonic source, flicker source,
asymmetric source location and power supply
failure type diagnose
Full Real-time Data Measurement
4 current and voltage inputs
8GB internal memory
8 digital input / 4 relay output
Supports Modbus RTU and TCP and IEC62850
Ride through voltage sags / voltage interruption
with built in energy storage
Continuous monitoring of the voltage quality
in accordance with DIN EN 50260
Collection of relevant data for energy
management systems
High-resolution waveform recording allows
analysis of power quality phenomena
Certification and Compliance
C€ 4Technical Specification
Power Supply “Measurement Parameters
Rated Voltage (4S"6SHx) ___ACBS265, DCLOO~300V Power Quality Analysis
Power Consumption <10W Wave Sampling 1024 pointsfeyle wave
Voltage Rie Through ~ 5.10 seconds| Harmonie 2-63rd Harmon, THO, TOD
‘Communication / interface Inter Harmonies 63rd inter harmonic
S485 /RS232 port 2 Pore, Modbus ATU Voliage Sag/Swel/Stop Waveform record
ous rate 2400-384008ps. “Transient Capture 20us circle wave transient
theme Port 1 por, Modbus TCP / 151850 Unbalance Volage. current and ero sequence
Digital np (0H) {8 channels Volage/Freq, Deviation Setpoint alarm and record
Relay Output (00) 4 Channels Rapid Voltage Alteration Trigger 00 point, wavetorm record
ROI-RO4 Aelay, action / return time: <10ms 9g Source Location locate power supply side
‘Optocoupler Output 2 Channels load sie abnormal and fault
Breaking Capacity: 250VA/30V0C, 0.24, Realtime Data Voltage, Current, Active power,
(Ufi=20ms Max. voltage 30VDC Reactive power, Apparent Power, Power
Max. current SOmA Factor, Frequency
‘Measurement Channel 4 channels foreach: Voltage / Current
Measuring ccuit Energy.
‘Measuring voltage i Enerey Postve / Negative active, reactive,
Rated voltage (4000 _(@OOV U/W / 650 /) apparent enerty: Positive / Negative
‘Overload 1.2 Un, Continuous Un, accept 18 base wave active, reactive energy
Power loss <0.1VA/Phase Harmonie Enerey| P-31st postive active
‘Measuring current inputs reactive harmonic energy, Negative
Rated Curent SALI active, reactive harmonic eneray
‘Overload ‘Ain, Continuous; 10m, accept 1s History Enerey ‘Storage latest 30 days an latest,
Power loss “