You are on page 1of 32
ee er Get the right kind of protection Feel completely safe and protected ()|RANGE Erecrric Empowering Humanity We are a multinational company, in Electrical, Lighting and Digital cee ere oR Lael aoe Le Rare} Cer acy We empower humanity by creating a brighter, cleaner and smarter future for everyone. From switches to smart techs to water saving, our products, technologies and services are class leading solutions for buildings and the built environment in both developed and developing countries, for today and creating a sustainable environment for the future gen- Corer What We Do | _ Saeed Health care Perea Ported a 72 060 4b — as nny ty eee oy Energy Enhanced ‘Orange Electric provides solutions in the sphere of energy with special attention to design and efficiency. SIGNA Connecting the World Offering complete end-to-end Network & Connectivity Solutions for industrial, commercial, medical and military sectors. Smarter Habitat Qbus develops products & technologie: turn homes, offices, hotels, factories & even hospitals into smart buildings. Smart solutions for convenience and energy-savings SUPERBAR Electrical Busduct Solutions Superbar offers world class Low Vokage Electrical Busbar Trunking Systems to meet the ever demanding and complex global ORELO Building a Greener Future Creating a brighter, cleaner future through class leading solutions, proven to reduce energy, water and maintenance costs and to reduce carbon footprint OREL® Transportation at a Click OrelGo is an App based taxi andl delivery booking solution that’s convenient, economical and brings you safely to your destination OREL® Seamless Mobile Payments OrelPay allows users to link thelr bank -ounts and credit cards with the OrelPay mobile app and carry out transactions by simply scanning a QR code. On-line Shopping convenience COREL Store is a one stop unmanned online store that offers the OREL portfolio of products at timely specials with istane wicle delivery. e ORANGE Energy Enhanced Our wide portfolio of Building Infrastructure products are innovative and of outstanding quality and value, intended to Empower Humanity by creating a brighter, cleaner and smarter future for everyone across the globe, Orange Electric provides solutions in the sphere of energy with special attention to design and efficiency. We have a range of Batteries, Home Appliances, Allied Accessories, Switches, Sockets, Wires, Cables, Circuit Breakers, Plugs and Connectors. In addition we have industrial products under Cable Management, Switch Gears, Enclosures, Busbar Trunking, Power D/Boards, Energy Optimizer, Generators, Solar, Elevators, and Electronic Robots. Content oO Alpha ~ Miniature Circuit Breaker ~ Residual Current Circuit Breaker = Isolator @ sigma ~ Miniature Circuit Breaker ~ Residual Current Circuit Breaker = Isolator e 10kA ~ Miniature Circuit Breaker ~ Residual Current Circuit Breaker = Isolator Get the Right Kind of Protection Orange Electric is a name synonymous with smarter and safer low voltage switchgear offering superior performance whilst conforming to the highest industry standards. Our range comes complete with both metal and plastic distribution boxes. ° ALPHA Miniature Circuit Breaker 1 POLE MoB ITEM CODE | RATED CURRENT | NO.POLES | TYPE | RATED VOLTAGE | RATED SHORT CIRCUIT CAPACITY (len) 470-1002 6A. 1 c >eovacov kA 470-1003, 108 1 ° 2a0/4coy KA ‘470-1004 168 1 ° 2e0/400y kA 470-1005 208 1 c 2ao/acov Kc ‘470-1007 22h 1 ° 2s0/400y KA APPLICATIONS, InclustialResidential/HotelGeneral Purpose PRODUCT SPECIFICATIONS Connection Method of Installation Warranty Period Standard Complied Certification Protection Protected Poles Rated Voltage Rated Frequency Rated Curent ‘Type of Trio Rated Service Short Circuit Capacityles) ‘Temperature Linvt Instantaneous Tripping Characteristics Dagree of Protection Rated Impulse withstand Volage(Uimp) Screw type terminals Mounting on 25mm DIN ra = Five years warranty ‘ lec 60898-1 / SLS 1175 ‘ o ss 0 ‘Against overload and short crcut ’ All poles protected : 1 pole - 280/400VAC s0/80H2 | 6, 10, 16, 20,92. ‘Thermal’ Magnetic release f KA “5 °C to +40°O Bot Type © 2 1P20 KV 01 | wwurorelcom A “Terms & Conditions Applied Residual Current Circuit Breaker QO|RAN ° GE 1p + NROCB ITEM CODE | RATED CURRENT | NO.POLES | RATED VOLTAGE _ [RATED RESIDUAL OPERATING CURRENT. 471-2001 408, 1PAN 230v 30ma, APPLICATIONS Industrial Residontalotel/Gonoral Purpose PRODUCT SPECIFICATIONS commcton Soe yp tra Mats sate sear on 25 Oa Maran Pre Fone wean == Sure Coo lec rope e108 poe) Cettification CB, KEMA . é Rated Voltage (Un) 230VAC (1P +N) Paves Hons cae Rated Current (In) 404 Tre ay Were re ey Pat Cro i) 2am Rave Condon Sar et Cr) + ea fate Condon he Shok reek | BA Ceres Rana akg sod rng Cassy): S008 Bata Roost an renter Caos soon Gite Chactosich Pact Typo AC Rost Cane whi Cerone Ao Tonpatreint 8r0t0 4980 recone axa ] J “Terms & Conations Applied vor com | 02 Isolator 2 Pole Isolator ITEM CODE RATED CURRENT NO.POLES RATED VOLTAGE 472-1001 408 2 2ao/aooy APPLICATIONS Industrial ResidontalotelvGeneral Purpose PRODUCT SPECIFICATIONS Connection Screw type terminals Method of Installation Mounting on 25mm DIN rail Warranty Poriod Fivo years warranty Standard Comalied le 6047-3 Suitabilty for Isolation Suitable Utilization Category AG-22A Kind of Current ac. Rated Frequency SOM ated Operational Voltage (Ue) 2a0/400VAC ‘i Rated Insulation Volage (U) s90v Rated Impulse withstand Voltage (Um): BY ated Operational Current 40A ‘ Conventional Free Air Thermal Cunentith) : 408 Rated Uninterrupted Current (u) 40a, x ated Short Time withstand Current ew) 12le, 1s Rated Short Circuit Making Capacity lem): 20le Dagree of Protection 120 oOlO OO Z — [—i- 4 HH 03 | wwurorelcom ‘Terms & Conditions Applied SIGMA Miniature Circuit Breaker 11 POLE McB ITEM CODE | RATED CURRENT | NO-POLES | TYPE | RATED VOLTAGE | RATED SHORT CIRCUIT CAPACITY (len) 470-3002 ea, 1 c 2aovoov kA 470-2008 108 1 c 2eo/4oov 6 470-2004 160 1 c 2ea/eoov 6k 470-008, 208 1 c 2a0/400v 6 470-2007 82a 1 c 2eoveoov ek 470-3008 404 1 c a0/400V 6k 470-3010 63a 1 c 2aovoov kA APPLICATIONS IndustriaResidentialHotel/Genoral Purpose PRODUCT SPECIFICATIONS Connection Screw type terminals Method of Installation Mounting on 26mm DIN rail a Warranty Patiod Lifetime warranty ¢ @ Standard Comalied IEC 60898-1 / SLS 1175 Cattitcation sis Protection Against overload and short circuit Protected Polos Rated Voltage (Un) Rated Frequency Rated Curent Type of Tip Rated Service Short Circuit Capacityles) Tomporature Linst Instantaneous Tripping Characteristics Degree of Protection Rated Impulse withstand Votage(Uimp) Allpoles protected 1 pole - 230/400VAC S0/60HZ 6, 10, 16, 20, 92, 40, 68. A ‘Thermal’ Magnetic release KA -5°0t0 440°C Tye P20) 4K a Lee “Terms & Conditions Applied —+—i— I KB % amas F vore.com | 04 ° 2 POLE MCB ITEM CODE | RATED CURRENT | NO-POLES | TYPE | RATED VOLTAGE | RATED SHORT CIRCUIT CAPACITY (len) 470-2011 6A. 2 c 400v kA 470-2072 108 2 c 400v KA, 470-203 168 2 c 400v BK 470-2014 208 2 c 400v KA, 470-2016 328 2 c 400v BK 470-3017 408, 2 c 400v KA 470-2019 63a 2 c 400v kA APPLICATIONS IndustriaResidentialHotel/Genoral Purpose PRODUCT SPECIFICATIONS Connection ‘Screw type terminals Method of Installation Mounting on 26mm DIN rail oe Warranty Patiod Lifetime warranty ' Standard Comalied IEC 60898-1 / SLS 1175 Cattitcation sis Protecton ‘gains overbad and shor ecu | Protected Poles Allpoles protected i Rated Voltage 2 pole - A00VAC. Rated Frequency S0/60Hz Rated Curent 6, 10, 16, 20, 22, 40, 63. Type of Tip ‘Thermal Magnetic release j i Rated Service Short Circuit Capacityles) Tomporature Linst Instantaneous Tripping Characteristics Degree of Protection Rated Impulse withstand Volage(Uimp) KA -5°0t0 440°C Tye P20. 4K “Terms & Conditions Applied OIRANG: ‘3 POLE MCB ITEM CODE | RATED CURRENT | NO.POLES | TYPE | RATED VOLTAGE | RATED SHORT CIRCUIT CAPACITY (len) 470-2020, 8A, 3 c 400V KA 470-3021 108 3 ° 400v 8K 470-2022 168 3 © 400v kA 470-3023, 208 3 ° 400v Kc 470-3025 22h 3 © 400v kA 470-2028 408 3 c 400v kA 470-2028 63a 3 c 400v KA APPLICATIONS Industrial ResidentalotelGeneral Purpose PRODUCT SPECIFICATIONS: Connection Method of Installation Warranty Poriod Standard Comalied Certification Protection Protected Polos ated Voltage Rated Frequency Rated Curent Type of Tip Rated Service Short Circuit Capacityles) Tomporature Linst Instantaneous Tipping Characteristics Degree of Protection Rated Impulse withstand Voltage(Uim) “Terms & Conctions Applied Screw type terminals Mounting on 26min DIN rail Lifetime warranty* lec 60898-1 / SLS 1175 sis Against overload and short circuit Allpoles protected 3 pole - A00VAC. S0/60Hz 6, 10, 16, 20, 22, 40, 6A ‘Thormal’ Magnetic release KA -5°0t0 440°C Tye P20. 4K v.ore.com | 06 ° “4 POLE MCB ITEM CODE | RATED CURRENT | NO.POLES | TYPE | RATED VOLTAGE | RATED SHORT CIRCUIT CAPACITY (len) 470-2029, 8A, 4 c 400V KA 470-3020, 108 4 ° 400v 8K 470-3081 168 4 © 400v kA 470-3032 208 4 c 400v kA 470-3034 22h 4 © 400V KA 470-2035 408 4 c 400v kA 470-2037 62a 4 c 400v KA APPLICATIONS Industrial Residontalotel/General Purpose PRODUCT SPECIFICATIONS: Connection Screw type terminals Method of Installation Mounting on 25mm DIN rail —_ =~ — > Warranty Poriod Standard Comalied Certification Protection Protected Polos ated Voltage Rated Frequency Rated Curent Type of Tip Rated Service Short Circuit Capacityles) Tomporature Linst Instantaneous Tripping Characteristics Degree of Protection Rated Impulse Withetand Voltage(Uimg) 07 | wwurorelcom Lifetime warranty* lec 6080 sis Against overload and short circuit Allpoles protected 4 pole - A00VAC. S0/60Hz {S18 1175 6, 10, 16, 20, 22, 40, 6A ‘ThormalMagnetic release KA -5°0t0 440°C Tye P20. 4K KH “Terms & Conditions Applied ° Residual Current Circuit Breaker ®IRANGE 1p + NROCB ITEM CODE | RATED CURRENT | NO.POLES | RATED VOLTAGE _ [RATED RESIDUAL OPERATING CURRENT. 471-4001 408, 1PAN 230v 30ma, 471-4002 408, 1PAN 230 100mA, 471-4004 3A, 1PAN 230 Oma, 471-4008, 3A, 1PAN 230¥ 100mA APPLICATIONS. InclustialResidentiaHotelGeneral Purpose PRODUCT SPECIFICATIONS Connection Screw type terminals Method of Installation Mounting on 35mm DIN rail Warranty Period Lifetime warranty* Standard Complied IEC 61008-1 & IEC $1008-2-1 Certification cB, KEMA Rated Voltage (Un) 2Q0VAC (IP +N) Rated Frequency S0He Rated Curent (In) 40, 6A Time Delay |Without time delay Rated Residual Current (lin) 0, 100mA for 40 & 62 Rated Conditional Short Circuit Curant(ine).: 10KA\ Rated Conditional Residual Short Circuit: 10K8, ‘Current (lc) Rated Making and Breaking Capacity) Rated Residual Making and Breaking Capacitylam) ‘Operating Characteristic in prasence of Residual Current with d.c Components Ambient Temperature Limit 500A or 10 In whichever is greater ‘500A or 10 In whichever is greater Type AC 25°C to 140°C t I \ I sey iT “Terms & Conations Applied vore.com | 08 ° 3P+ NRCCB ITEM CODE | RATED CURRENT | NO.POLES | RATED VOLTAGE _ [RATED RESIDUAL OPERATING CURRENT 471-4007 408, SPAN 400¥ 30ma, 471-4008 408, SPAN 400¥ 100mA 471-4010 3A, PAN 400V Oma, 471-4011 3A, 2PN ‘400V s00mA art-aor2 2A 3P +N 400V 300mA APPLICATIONS Industrial Residential/HotelGeneral Purpose PR@RWGT SPECIFICATIONS Screw type terminals Method of instalation Warranty Poriod Standard Comalied Certification Rated Voltage (Un) Rated Frequency Rated Curent (In) Time Delay Rated Residual Curent (Win) Rated Conditional Short Circuit Current(ine) Rated Conditional Residual Short Cireuit Current tlc} ated Making and Breaking Capacity) Rated Residual Making end Breaking Capacity) Operating Characteristic in Presence of Residual Current with dc Components ‘Ambient Temperature Limi ‘Mounting on 25mm DIN rai Lifetime warranty* IEC 61008-1 & IEC 61008-2-1 0B, KEMA, 4O0VAC (3 +N) S0Hz 40, 63 Without time delay 0, 100mA for 40A & 20, 100, 300mA for 6A, ‘Oks 10kA Type Ac 25 °0t0 140°C 09 | wwurorelcom Ese ‘500A oF 10 In whichever is greater ‘800A or 10 In whichever is greater “Terms & Conditions Applied OIRANG: ° Isolator POLE SOLATOR ITEM ODE RATED CURRENT NO.POLES RATED VOLTAGE 472-4001 408 2 230/400V 472-4002 6A 2 za0/400v APPLICATIONS Incitril Resicental/ote/Generl Purpose PRODUCT SPECIFICATIONS Connection Serow ype terminals Mathod of Istalaton Mounting on 35mm DIN ral =- = Warranty Period Lifetime warranty* an Standard Complied lec 60047-3 » » Cortcton ce Suita for Isolation Suitable Utization Category AG-22A ‘ onaot Kin of Curent ac. —— Rated Frequency soHe Rated Operational Voltage (Ue) 220/400VAC - (2) Rated insulation Votage (U) s20v Rated impula withstand Votage (imp) kV \ | Rated Operational Current (le) 40, 634, Conventional Free Air Thermal Cuentith) + 40, 62”, Rated Uninterupted Curent 40, 60 Ratod Short Timo withstand Cunent few) + 12a, 1s Rated Short Circuit Making Capacity lem): 201e Dagree of Protection Temperature Linvt P20. “5 °C to 440°C = “Terms & Conctions Applied vore.com | 10 3 POLE BOLATOR ITEM CODE RATED CURRENT NO.POLES RATED VOLTAGE 472-4004 408 2 4o0v 472-4008 63a 3 4oov APPLICATIONS, Inclustial ResidentilHotelGeneral Purpose PRODUCT SPECIFICATIONS Connection Matnod of Installation Warranty Period Standard Complied Corttication| Suitabilty for Isolation Utiization Category Kind of Current Rated Frequency ated Operational Voltage (Ue) Rated insulation Votage (U) Rated Imoulse withstand Vaage (Uimp) ated Operational Curent () Conventional Free Air Thermal Curentth) Rated Uninterrupted Current (u) ated Short Time withstand Rated Short Circuit Making Capacity (lem) Dagree of Protection Temperature Linvt 11 | wwworel.com Screw type terminals Mounting on 85mm DIN rai Lifetime warranty* lec 60047-3 fod Suitable AC-228, s0Hz 400VAC - (@P) so0y BK 40, 634 40, 63A, 40, 634, 2le, 18. 2016 P20. Current (ew) “5 °C to 440°C “Terms & Conditions Applied OIRANG: ‘4 POLE OLATOR ITEM CODE RATED CURRENT NO-POLES RATED VOLTAGE 472-4007 40a, 4 400V 472-4008 6A, 4 4ooy APPLICATIONS. ResidentialHoteVGeneral Purpose PRODUCT SPECIFICATIONS Connection Matnod of Installation Warranty Period Screw type terminals Mounting on 25mm DIN rai Lifetime warranty* Standard Complied lec 60047-3 Corttication| fod Suitabilty for Isolation Suitable Utilization Category AC-228, Kind of Current ac. Rated Frequency 50H ated Operational Voltage (Ue) 400VAC - ( Rated insulation Votage (U) so0v Rated Impulse withstand Voltage (Uimp) —: 6xV ated Operational Curent () 40, 634 Conventional Free Air Thermal Gurent(th) + 40, 683A, Rated Uninterrupted Current (u) 40, 634, ated Short Time withstand Curent few): 126, 18, Rated Short Circuit Making Capacity lem): 201e P20. “5 °C to 440°C Dagree of Protection Temperature Linvt “Terms & Conctions Applied vnore.com | 12 Best Protect From — Fires caused by arc fat 2 10kA Miniature Circuit Breaker 1 POLE MCB ITEM CODE | RATED CURRENT | NO-POLES | TYPE | RATED VOLTAGE | RATED SHORT CIRCUIT CAPACITY (len) 510-1001 2A 1 c 24o/a18V 10k 510-1002 6A 1 c 2aoiatev 10k, 510-1003 108 1 c 2aovarey 10k, 510-1004 168 1 c 2ao/atey 10kA 510-1005 208, 1 © 2aovarey 10kA, 510-1008 258 1 c 24ovatsv 10k 510-1007 22h, 1 c 2eiatey 10kA, 510-1008, 408 1 c 240/a18v 10K 510-1010, 623A, 1 c 2aoiarey 10k APPLICATIONS IndustialResicontialHoteVGeneral Purpose PRODUCT SPECIFICATIONS Connection Method of Installation Warranty Period Standard Compled Cettiication SiS, 181 Protection ‘Against overload and short circuit Protected Poles Allpoles protected Rated Voltage 1 pole - 240/4 15VAC ated Frequency ‘s0/60Hz ated Current 2,8, 10, 18, 20, 25, 32, 40, 63. ‘Type of Tip Thermal Magnetic release Rated Service Short Creuit Capacitylcs) = 7.5kA Temperature Limit “5 °C to 440°C. Instantaneous Tripping Characteristics Type Dogree of Protection P20 Rated Impulse withstand Voltage(uimp) = 4KV 15 | wuworelcom ‘Screw type torninals ‘Mounting on 26mm DIN rail Lifetime warranty” TEC 60898-1//SLS 1175 “Terms & Conditions Applied ° OIRANG: TaN ITEM CODE | RATED CURRENT | NO.POLES | TYPE | RATED VOLTAGE | RATED SHORT CIRCUIT CAPACITY (len) APPLICATIONS tek edetatt Gena Poros PRODUCT SPECIFICATIONS Comecton serow ype triads erenty Pats Ute wera Sond Compod feo enene-1/ 181175 Peete Pole Alpabs potted Rated Voltage 2 pole - 415VAC \ Patea Meany sah Type of Trip, Thermal/ Magnetic release « Raed Service Short Greuit Capacitytes) “Temperature Limit Instantaneous Tipping Characteristics Degree of Protection Rated Impulse withstand Vottage(imp) “Terms & Conaitons Applied 7.8K -5°C to 440°C. ‘pec 1P20 aKV vore.com | 16 3 POLE MCB APPLICATIONS PRODUCT SPECIFICATIONS cat ssa eee Het Of tt 17 | wuworel.com “Terms & Conditions Applied ° OIRANG: 4 POLE MCB ITEM CODE | RATED CURRENT | NO.POLES | TYPE |RATED VOLTAGE | RATED SHORT CIRCUIT CAPACITY (len) 510-1029 8A, 4 c a18v 10kA 510-1020, 108 4 c a18y 10k 510-1031 168 4 © a18y 10k, 510-1022 208 4 c angy 10kA 510-1033, 25A, 4 ° a18y 10kA, 510-1034 228, 4 © a18v 10kA 510-1035, 404 4 c a18V 10kA, 510-1037 634, 4 a1By 10kA APPLICATIONS Industial Residential HoteVGeneral Purpose PRODUCT SPECIFICATIONS Connection ‘Screw type terminals Method of Installation Mounting on 36mm DIN ral =_- - Warranty Poriod Lifotime warranty" — Standard Compled IEC G0898-1/ SLS 1175 Cartication SiS, 11 eee e Prot Against overload and short rut i: fi Pro Apots protected a Rated Voltage 4 pole - 415VAC. Rated Frequency 0/60H2 ated Current 6, 10, 16, 20, 25, 22, 40, 68. A, Type of Tip Thermal’ Magnetic release , Rated Service Short Crouit Capaciyes)—: 7.5kA ‘Temperature Limit 5°C to 440°C Instantaneous Tipping Characteristics Type Degree of Protection 1P20 FRatad Impulse withstand Voltage(uima)—: 4 “Terms & Conctions Applied vrworel.com | 18 Residual Current Circuit Breaker 1p = NAGE ITEM CODE | RATED CURRENT | NO.POLES | RATED VOLTAGE _ RATED RESIDUAL OPERATING CURRENT. 512-2001 408, IPN 240V 20mA, 512-2002, 404, 1PaN 240V s00mA 812-2003, 404, IPN 240V 300m, 812-2004 634, 1PN 240¥ 20ma, 512-2005, 628, IPN 240¥ t00ma, 812-2006 3A, 1PN 240V 300mA APPLICATIONS, InclustialResidentialHotelGeneral Purpose PRODUCT SPECIFICATIONS Connection Screw type terminals Metnod of Installation Mounting on 25mm DIN ral Warranty Period Lifetime warranty* Standard Compliod IEC 61008-1 & IEC 1008-2-1 Certification KEMA ated Votage 2AQVAC (IP +N) Rated Frequency s0H2 Rated Curent (In) 40,634 Time Daley’ \Withour time dolay Rated Residual Current (Win) 30, 100, 300m Rated Conditional Short Circuit Current{ine). 1 10KA\ atod Conditional Residual Short Cut: 10KA, ‘Current (isc) Rated Making and Breaking Capaeity(im) ated Residual Making and Breaking Capacitylam) Operating Characteristic in Presence of osidual Current with d.c Components Ambient Temperature Limit ‘500A or 10 In whichever is greater ‘800A or 10 In whichever is greater Type AC 25°C 10 440°C 18 | wuworel.com “Terms & Conditions Applied ®|IRANGE 3P + NRGCE ITEM CODE | RATED CURRENT | NO.POLES | RATED VOLTAGE _ [RATED RESIDUAL OPERATING CURRENT 912-2007, 408, 3PN ai8v 30ma, 512-2008, 404, PsN 418V 100mA 812-2009 404 2PsN 418v 300mA 512-2010 634, 3P-N a15v 30ma, 512-2011 3A, PAN 418V s00mA 912-2012 63a PsN a18v 300mA 812-2013 1008, PsN a18y 0mA, 512-2014 1008, 3PiN 415V 100mA 512-2015 100A, PsN 418y 200mA, APPLICATIONS InclustialResidential/HotelGeneral Purpose PRODUCT SPECIFICATIONS Connection Sorew type terminals Mothod of Installation Mounting on 35mm DIN rai Warranty Period Lifetime warranty* = Standard Complied IEC 61008-1 & IEC $1008-2-1 Certification KEMA ated Voltage 418VAC GP +N) Rated Frequency S0He Rated Current (In) 40, 63, 1008, Time Delay |Without time delay Rated Residual Current (Win) 80, 100, 800m Rated Conditional Short Circuit Currant(ine) : 10K, ated Conditional Residual Short Circuit: 10kA, ‘Current (ic) Rated Making and Breaking Capactty(in) ated Residual Making and Breaking Capacitylam) Operating Characteristic in Presance of Pesidual Current with d.c Components Ambient Temperature Limit {500A or 10 In whichever is greater ‘800A or 10 In whichever is greater Type AC -25 °C to +40°C Lyd bef e “Terms & Conditions Applied vcore.com | 20 Isolator 2 POLE BOLATOR ITEM CODE RATED CURRENT NO.POLES RATED VOLTAGE 513-2001 408 2 290/00 613-2002 6A 2 2a0/400v 518-2003 1008 290/400 APPLICATIONS. InclustialResidentiaHotevGeneral Purpose PRODUCT SPECIFICATIONS Connection Screw type terminals Matnod of Installation Mounting on 85mm DIN rai Warranty Period Lifetime warranty* Standard Complied lec 60047-3 Suitabilty for Isolation Suitable Utlization Category AC-228, Kind of Current ac. Rated Frequency s0H2 Rated Operational Voltage (Us) 230/200VAC Rated insulation Vokage (U) so0v Rated Impulse withstand Voltage (Ump) + 6kY Rated Operational Curent () 40, 63, 1008, Conventional Free Air Thermal Gunontith) + 40, 63, 1008 Rated Uninterrupted Current (u) 40, 63, 1008, Rated Short Time withstand Current (cw): 12le, 18, atod Short Circuit Making Capactty lem): 2012 Degree of Protection IP 20 Temperature Limit 25 °O% Lee [ a= 21 | wuworel.com ;—! Hi -@P) +40° “Terms & Conditions Applied OIRANG: 3 POLE BOLATOR ITEM CODE RATED CURRENT NO.POLES RATED VOLTAGE 818-2004 408 2 4o0v 613-2008, 6A 3 4oov 518-2008, 1008 4oov APPLICATIONS, InclustialResidentiaHotelvGeneral Purpose PRODUCT SPECIFICATIONS Connection Screw type terminals Matnod of Installation Mounting on 85mm DIN rai Warranty Period Lifetime warranty* — = = Standard Complied lec 60047-3 Suitabilty for Isolation Suitable Utlization Category AC-228, Kind of Current ac. Rated Frequency s0H2 Rated Operational Voltage (Us) 400VAC - (2P) Rated insulation Vokage (U) so0v Rated Impulse withstand Voltage (Ump) + 6kY Rated Operational Curent () 40, 63, 1008, Conventional Free Air Thermal Gunntith) + 40, 63, 100A Rated Uninterrupted Current (u) 40, 63, 1008, Rated Short Time withstand Current (cw): 12le, 18, atod Short Circuit Making Capactty lem): 208 Degree of Protection IP 20 Temperature Limit 25°C 10+ 40°C “Terms & Conations Applied vew.ore.com | 22 4 POLE BOLATOR ITEM CODE RATED CURRENT NO.POLES RATED VOLTAGE 513-2007, 408 4 4o0v 613-2008 6A 4 4oov 513-2009 1008 4 4oov APPLICATIONS, Inclustial Residential HotevGeneral Purpose PRODUCT SPECIFICATIONS Connection Screw ype terminals Motnod of instalation Mounting on 35mm DIN rail Warranty Period Lifetime warranty = Standard Compled IEC 60947-3 ee > Suitailty for Isolation Suitable a Utization Category AC-208 eee @ kind of Curent ac i Rated Frequency soe Rated Operational Vltage (Us) 00VAC -(4P) ' see Rated Insulation Voliago (U) 690v Rated Impulse withstand Volage (Uimp) + kV ’ Rated Operational Curent () 40, 63, 1008, \ Conventional Fre0 Air Thornal Cunontith) : 40, 63, 100A, Rated Uninterrupted Curent (uy) 40, 63, 1008 Rated Short Time withstand Curent ew): 12le, 18 \ Ratod Short Circuit Making Capacty om): 201a Degree of Protection IP 20 Temperature Limit 25°C 10+ 40°C 23 | wuworel.com ‘Terms & Conditions Applied OREL 9 Orel Regional Offices @ Export Distributor Points wearein 28 countries, employing 5317 personnel, empowering 5000 business partners across 6 Continents Contact Us OREL North America OREL Asia Pacific OREL Middle East 16192 Coastal Hignway, Lovol 28, AMP Tower, 503, Business Point Building Lowes, 140 St Georges Terrace, Plot No: 129-674, Port Saeed, 19958, Perth, Deira, Dubai, United Arab Emirates. County of Sussex, Australia. T: 497 149 888 722 USA T: 461 892 884 503 E:me@orelcomp.com 413.089 447 710 apac@orelcorp.com E : usa@orelcorp.com OREL South Asia OREL South East Asia ATAFIEE, 55 UBI Avenue 1 #02-10 COKHILA Industrial Area - Phase 2, UBISS, Now Dothi- 110020, Singapore 408035, Inala. T:465 6970 6547, T: +91 114 106 9843, E: sea@orelcorp.com E : sa@oreleorp.com ® RANGE OREL CORPORATION (PVT) LTD Bay 12, Tace Export Ci, pol Square, Colmbo 10, Sri Lanka, +84 114 782 100 | sk@orelorp.com |wwworeLeom omen nen

You might also like