MORE POWER
-0.35 % / °C
1st year power degradation no more than 2%
Subsequent annual power degradation no more than 0.55%
Better shading tolerance
*According to the applicable Canadian Solar Limited Warranty Statement.
* The specific certificates applicable to different module types and markets will vary,
and therefore not all of the certifications listed herein will simultaneously apply to the
Heavy snow load up to 5400 Pa, products you order or use. Please contact your local Canadian Solar sales representative
wind load up to 3600 Pa* to confirm the specific certificates available for your product and applicable in the regions
in which the products will be used.
6-Φ5 9 9
Grounding
Hole 8 8
8-14x9 7 7
Mounting
Hole 6 6
5 5
4-10x7
Mounting
4 4
Hole(tracker)
3 3
2108
1300
1155
400
2 2
Mounting Hole 1 1
0 V0 V
R R 5 10 15 20 25 30 35 40 45 50 5 10 15 20 25 30 35 40 45 50
A A
1000 W/m2 5°C
10
14
35 1048
PARTNER SECTION
* The specifications and key features contained in this datasheet may deviate slightly from our
actual products due to the on-going innovation and product enhancement .CSI Solar Co., Ltd.
reserves the right to make necessary adjustment to the information described herein at any time
without further notice.
Please be kindly advised that PV modules should be handled and installed by qualified people who
have professional skills and please carefully read the safety and installation instructions before
using our PV modules.
Input Side
Max. DC Input Power (kW) 9.8 10.4 13
Max. DC Input Voltage (V) 550
Start-up DC Input Voltage (V) 120
MPPT Operating Range (V) 100~550
Max. DC Input Current (A) 12.5+25 12.5+25 25+25
Number of MPPT / Strings per MPPT 2 / 1+2 2 / 1+2 2 / 2+2
Output Side
Rated Output Power (kW) 7.5 8 10
Max. Active Power (kW) 8.3 8.8 11
Rated AC Grid Voltage (V) 230
AC Grid Voltage Range (V) 180Vac~300 Vac (this may vary with grid standards)
Rated Grid Frequency (Hz) 50 / 60 (Optional)
Operating Phase Single phase
Rated AC Grid Output Current (A) 32.6 34.8 43.5
Max. AC Output Current (A) 35.9 38.3 47.8
Output Power Factor 0.8 leading to 0.8 lagging
Grid Current THD <2%
DC Injection Current (mA) <0.5%
Grid Frequency Range 47~52 or 57~62 (Optional)
Efficiency
Max. Efficiency 97.7%
Euro Efficiency 97.5%
MPPT Efficiency >99%
Protection
DC Reverse-Polarity Protection Yes
AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote software upload Yes
Remote change of operating parameters Yes
Surge protection DC Type II / AC Type II
General Data
Size (mm) 330W×310H×198.5D
Weight (kg) 11
Topology Transformerless
Internal Consumption <1W (Night)
Running Temperature -25~65℃
Ingress Protection IP65
Noise Emission (Typical) <25 dB
Cooling Concept Natural cooling
Max. Operating Altitude Without Derating 2000m
Designed Lifetime >20 years
Grid Connection Standard ABNT NBR 16149, ABNT NBR16150, ABNT NBR IEC 62116
Operating Surroundings Humidity 0-100%
Safety EMC / Standard IEC62109-1/-2, EN61000-6-1, EN61000-6-3
Features
DC Connection MC-4 mateable
AC Connection IP65 rated plug
Display LCD1602
Interface RS485/RS232/Wifi/LAN
Add: No.26-30, South Yongjiang Road, Beilun, 315806, Ningbo, China | Tel: 0086-0574-86120560 | E-mail: market@deye.com.cn | Web: www.deyeinverter.com