You are on page 1of 6

Version 7.1.

PVsyst - Simulation report


Grid-Connected System

Project: MK_PLPE
Variant: New simulation variant
No 3D scene defined, no shadings
System power: 22.40 kWp
Semarang-Pascasarjana - Indonesia

Author
Project: MK_PLPE
Variant: New simulation variant

PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1

Project summary
Geographical Site Situation Project settings
Semarang-Pascasarjana Latitude -6.99 °S Albedo 0.20
Indonesia Longitude 110.42 °E
Altitude 10 m
Time zone UTC+7

Meteo data
Semarang
Meteonorm 7.3 (2010-2014), Sat=100% - Synthetic

System summary
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Monthly values
Tilt/Azimuth 10 / 0 °

System information
PV Array Inverters
Nb. of modules 64 units Nb. of units 1 Unit
Pnom total 22.40 kWp Pnom total 20.00 kWac
Pnom ratio 1.120

Results summary
Produced Energy 35.03 MWh/year Specific production 1564 kWh/kWp/year Perf. Ratio PR 82.68 %
Solar Fraction SF 47.69 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6

16/03/23 PVsyst Licensed to Page 2/6


Project: MK_PLPE
Variant: New simulation variant

PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Horizon


Orientation Models used Free Horizon
Fixed plane Transposition Perez
Tilt/Azimuth 10 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

Near Shadings User's needs


No Shadings Monthly values

Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Year
29.8 33.6 44.6 36.0 29.8 43.2 37.2 52.1 43.2 37.2 28.8 67.0 482 kWh

PV Array Characteristics
PV module Inverter
Manufacturer Longi Solar Manufacturer SMA
Model LR4-60 HPH 350 M Model Sunny Tripower 20000TL-30
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 350 Wp Unit Nom. Power 20.0 kWac
Number of PV modules 64 units Number of inverters 2 * MPPT 50% 1 units
Nominal (STC) 22.40 kWp Total power 20.0 kWac
Modules 4 Strings x 16 In series Operating voltage 320-800 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.12
Pmpp 20.36 kWp
U mpp 482 V
I mpp 42 A

Total PV power Total inverter power


Nominal (STC) 22 kWp Total power 20 kWac
Total 64 modules Nb. of inverters 1 Unit
Module area 120 m² Pnom ratio 1.12
Cell area 106 m²

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 191 mΩ Loss Fraction -0.4 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses Strings Mismatch loss


Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

IAM loss factor


Incidence effect (IAM): User defined profile

0° 25° 45° 60° 65° 70° 75° 80° 90°


1.000 1.000 0.995 0.962 0.936 0.903 0.851 0.754 0.000

16/03/23 PVsyst Licensed to Page 3/6


Project: MK_PLPE
Variant: New simulation variant

PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1

Main results
System Production
Produced Energy 35.03 MWh/year Specific production 1564 kWh/kWp/year
Performance Ratio PR 82.68 %
Solar Fraction SF 47.69 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_User E_Solar E_Grid EFrGrid
kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh MWh MWh MWh
January 116.5 70.67 27.23 111.1 108.2 2.134 0.030 0.014 2.060 0.015
February 118.0 73.51 26.99 115.2 112.6 2.220 0.034 0.017 2.142 0.017
March 139.6 79.64 27.52 139.9 136.9 2.669 0.045 0.022 2.574 0.023
April 145.5 74.74 27.82 150.7 147.8 2.873 0.036 0.017 2.780 0.019
May 161.5 66.70 28.42 173.7 170.6 3.295 0.030 0.014 3.194 0.016
June 156.5 62.24 27.79 171.5 168.4 3.276 0.043 0.020 3.170 0.023
July 166.2 59.14 27.79 181.1 178.1 3.441 0.037 0.017 3.332 0.020
August 178.2 70.72 28.14 188.5 185.5 3.563 0.052 0.024 3.442 0.028
September 179.1 77.72 28.37 182.2 179.1 3.428 0.043 0.020 3.315 0.023
October 177.2 98.00 28.78 174.3 171.0 3.304 0.037 0.018 3.197 0.019
November 186.5 86.81 27.92 178.1 174.6 3.378 0.029 0.015 3.271 0.014
December 132.0 87.69 27.48 125.6 122.3 2.426 0.067 0.033 2.328 0.034
Year 1856.8 907.58 27.86 1891.8 1855.2 36.006 0.482 0.230 34.804 0.252

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_User Energy supplied to the user
T_Amb Ambient Temperature E_Solar Energy from the sun
GlobInc Global incident in coll. plane E_Grid Energy injected into grid
GlobEff Effective Global, corr. for IAM and shadings EFrGrid Energy from the grid

16/03/23 PVsyst Licensed to Page 4/6


Project: MK_PLPE
Variant: New simulation variant

PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1

Loss diagram
1857 kWh/m² Global horizontal irradiation
+1.9% Global incident in coll. plane

-1.93% IAM factor on global

1855 kWh/m² * 120 m² coll. Effective irradiation on collectors

efficiency at STC = 18.77% PV conversion

41.64 MWh Array nominal energy (at STC effic.)


-0.08% PV loss due to irradiance level

-10.98% PV loss due to temperature

+0.37% Module quality loss

-2.10% Mismatch loss, modules and strings

-1.08% Ohmic wiring loss


36.01 MWh Array virtual energy at MPP
-2.70% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
grid
0.00% Inverter Loss due to voltage threshold
consumption
35.03 MWh Available Energy at Inverter Output

0.25 0.23 34.80 MWh Energy injected into grid

to user to user to grid


from grid from solar

16/03/23 PVsyst Licensed to Page 5/6


Project: MK_PLPE
Variant: New simulation variant

PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1

Special graphs
Daily Input/Output diagram

System Output Power Distribution

16/03/23 PVsyst Licensed to Page 6/6