Professional Documents
Culture Documents
Semarang Pascasarjana - Project - VC0 Report
Semarang Pascasarjana - Project - VC0 Report
Project: MK_PLPE
Variant: New simulation variant
No 3D scene defined, no shadings
System power: 22.40 kWp
Semarang-Pascasarjana - Indonesia
Author
Project: MK_PLPE
Variant: New simulation variant
PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1
Project summary
Geographical Site Situation Project settings
Semarang-Pascasarjana Latitude -6.99 °S Albedo 0.20
Indonesia Longitude 110.42 °E
Altitude 10 m
Time zone UTC+7
Meteo data
Semarang
Meteonorm 7.3 (2010-2014), Sat=100% - Synthetic
System summary
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 64 units Nb. of units 1 Unit
Pnom total 22.40 kWp Pnom total 20.00 kWac
Pnom ratio 1.120
Results summary
Produced Energy 35.03 MWh/year Specific production 1564 kWh/kWp/year Perf. Ratio PR 82.68 %
Solar Fraction SF 47.69 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6
PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1
General parameters
Grid-Connected System No 3D scene defined, no shadings
Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Year
29.8 33.6 44.6 36.0 29.8 43.2 37.2 52.1 43.2 37.2 28.8 67.0 482 kWh
PV Array Characteristics
PV module Inverter
Manufacturer Longi Solar Manufacturer SMA
Model LR4-60 HPH 350 M Model Sunny Tripower 20000TL-30
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 350 Wp Unit Nom. Power 20.0 kWac
Number of PV modules 64 units Number of inverters 2 * MPPT 50% 1 units
Nominal (STC) 22.40 kWp Total power 20.0 kWac
Modules 4 Strings x 16 In series Operating voltage 320-800 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.12
Pmpp 20.36 kWp
U mpp 482 V
I mpp 42 A
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 191 mΩ Loss Fraction -0.4 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1
Main results
System Production
Produced Energy 35.03 MWh/year Specific production 1564 kWh/kWp/year
Performance Ratio PR 82.68 %
Solar Fraction SF 47.69 %
GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_User E_Solar E_Grid EFrGrid
kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh MWh MWh MWh
January 116.5 70.67 27.23 111.1 108.2 2.134 0.030 0.014 2.060 0.015
February 118.0 73.51 26.99 115.2 112.6 2.220 0.034 0.017 2.142 0.017
March 139.6 79.64 27.52 139.9 136.9 2.669 0.045 0.022 2.574 0.023
April 145.5 74.74 27.82 150.7 147.8 2.873 0.036 0.017 2.780 0.019
May 161.5 66.70 28.42 173.7 170.6 3.295 0.030 0.014 3.194 0.016
June 156.5 62.24 27.79 171.5 168.4 3.276 0.043 0.020 3.170 0.023
July 166.2 59.14 27.79 181.1 178.1 3.441 0.037 0.017 3.332 0.020
August 178.2 70.72 28.14 188.5 185.5 3.563 0.052 0.024 3.442 0.028
September 179.1 77.72 28.37 182.2 179.1 3.428 0.043 0.020 3.315 0.023
October 177.2 98.00 28.78 174.3 171.0 3.304 0.037 0.018 3.197 0.019
November 186.5 86.81 27.92 178.1 174.6 3.378 0.029 0.015 3.271 0.014
December 132.0 87.69 27.48 125.6 122.3 2.426 0.067 0.033 2.328 0.034
Year 1856.8 907.58 27.86 1891.8 1855.2 36.006 0.482 0.230 34.804 0.252
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_User Energy supplied to the user
T_Amb Ambient Temperature E_Solar Energy from the sun
GlobInc Global incident in coll. plane E_Grid Energy injected into grid
GlobEff Effective Global, corr. for IAM and shadings EFrGrid Energy from the grid
PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1
Loss diagram
1857 kWh/m² Global horizontal irradiation
+1.9% Global incident in coll. plane
PVsyst V7.1.1
Simulation date:
16/03/23 05:35
with v7.1.1
Special graphs