You are on page 1of 102

DOC.No.: AO-21612A.

xls
Date:2008-09-02

PROJECT INFORMATION :

CUSTOMER : SAMJIN Shipbulding Industry

SHIP OWNER : BOCIMAR

HULL NO. : SAMJIN H1013-16/1021-26

SHIP KIND : 33,5K DWT BULK CARRIER

SHIP YARD : SAMJIN Shipbulding Industry

CLASS : DNV

MAIN ENGINE TYPE : DOOSAN MAN B&W 6S50MC

MAX. CONTINUOS RPM : 8,580 KW X 127 RPM

DATE MARK DESCRIPTION DESIGN CHECK APPR.


18-Apr-08 1. Prepared the approval drawing. EJJ KWL

2-Sep-08 1.Prod.Issue ECO AOE-017707 JJ GHE

28-Nov-08 1. Changed AMS with other maker EJJ JHJ KWL

10-Nov-09 1. Prepared the final drawing for H1013 EJJ JHJ KWL

SAMJIN H1013-16/1021-26
KM Korea Ltd.
Kongsberg Maritime AS
AO-20221- / 22-Jan-08

Serial line signals


between
AC-C20 and AMS
for
(MAN B&W MC/MC-C version)

© 2008 KONGSBERG MARITIME AS


All rights reserved
No part of this work covered by the copyright
hereon may be reproduced or otherwise copied
without prior permission from
KONGSBERG MARITIME AS

Serial line signals between AC C20 and AMS/VDR


Kongsberg Maritime AS
AO-20221- / 22-Jan-08

DOCUMENT STATUS

Issue No. Date/Year Inc. by Issue No. Date/Year Inc. by

CHANGES IN DOCUMENT

Issue ECO Paragraph Paragraph Heading/


No. No. No. Description of Change

Serial line signals between AutoChief C20/other AMS i


Kongsberg Maritime AS
AO-20221- / 22-Jan-08

Design Basis for Standard Serial Line Interface to Kongsberg Maritime


Modbus Protocol

Serial interface between AC C20 Bridge Manouvering System.

1. Protocol Modbus: RTU ;


ASCII †

2. Supported commands are commands 1-16 which are:

01. read coil status (= read PLC output, binary)


02. read input status (= read PLC input , binary)
03. read holding register (= read PLC word register value ,16bit)
04. read input register (= read PLC analogue input value , 16bit)
05. force single coil ( = write to PLC output , binary )
06. preset single register ( = write to PLC word register , 16bit)
15. Force multiple coils ( = write to PLC outputs , binary )
16. Preset multiple registers ( = write to PLC word registers , 16bit)

3. Electrical Interface: RS-422 †


RS-485 ;

4. Com port configuration


Parity: even
Data bits: 8
Stop bit: 1
Baud rate: 9600

5. Slave ID numbers: 1

6. Additional information: Time delay of all parameters is to be prepared

Serial line signals between AutoChief C20/other AMS ii


Kongsberg Maritime AS
AO-20221- / 22-Jan-08

SIGNALS FROM AC-C20 TO AMS


XI : INDICATION XA: ALARM
Real
Modbus Signal Signal PLC Function Real
Adress
Description of tag Function
Unit Type ID 1-16 Range H
Range
L

1 M/E SHUT DOWN XA ON/OFF digital 1 1

2 M/E SLOW DOWN XA ON/OFF digital 1 1

3 M/E OVER SPEED XA ON/OFF digital 1 1

4 M/E WRONG WAY XA ON/OFF digital 1 1

5 M/E START BLOCKED XA ON/OFF digital 1 1

6 M/E RPM DETECTOR FAIL XA ON/OFF digital 1 1

7 M/E START FAIL XA ON/OFF digital 1 1

8 M/E LIMITATION CANCELLED XA ON/OFF digital 1 1

9 M/E LOAD PROGRAM CANCELLED XA ON/OFF digital 1 1

10 M/E EM'CY STOP(COMMON) XA ON/OFF digital 1 1

11 M/E SHUT DOWN CANCELLED XA ON/OFF digital 1 1

12 M/E SLOW DOWN CANCELLED XA ON/OFF digital 1 1

13 ALARM BLOCKED (ME STOP) XI ON/OFF digital 1 1

14 FINISHED WITH ENGINE XI ON/OFF digital 1 1

15 *START AIR PRESSURE LOW XA ON/OFF digital 1 1

16 *BRIDGE CONTROL POSITION XI ON/OFF digital 1 1

17 *ECR CONTROL POSITION XI ON/OFF digital 1 1

18 *LOCAL CONTROL POSITION XI ON/OFF digital 1 1

19 *M/E REMOTE CONT SYS POWER FAIL XA ON/OFF digital 1 1

20 M/E REMOTE CONT SYS ABNORMAL XA ON/OFF digital 1 1

21 M/E TELEGRAPH SYS POWER FAIL XA ON/OFF digital 1 1

22 M/E TELEGRAPH SYS ABNORMAL XA ON/OFF digital 1 1

23 M/E SAFETY SYS POWER FAIL XA ON/OFF digital 1 1

23 M/E SAFETY SYS ABNORMAL XA ON/OFF digital 1 1

24 M/E GOVERNOR SYS POWER FAIL XA ON/OFF digital 1 1

25 M/E GOVERNOR SYS ABNORMAL XA ON/OFF digital 1 1

26 SPARE XA ON/OFF digital 1 1

27 SPARE XA ON/OFF digital 1 1

28 ORDER PRINTER FAILURE XA ON/OFF digital 1 1

29 SPARE XA ON/OFF digital 1 1

30 M/E NOT READY XA ON/OFF digital 1 1

31 M/E CRITICAL SPEED(BELOW 8CYL) XA ON/OFF digital 1 1

32 M/E RPM DETECTOR LOOP FAIL XA ON/OFF digital 1 1

33 M/E EM’CY STOP LOOP FAIL XA ON/OFF digital 1 1

Serial line signals between AutoChief C20/other AMS 1


Kongsberg Maritime AS
AO-20221- / 22-Jan-08

34 SPARE XA ON/OFF digital 1 1

35 SPARE XA ON/OFF digital 1 1

36 SPARE XI ON/OFF digital 1 1

37 SPARE XI ON/OFF digital 1 1


M/E ENGINE ORDER RPM
40001 XI RPM Analog 1 3 120 -120
(BRIDGE LEVER)
40002 *M/E RPM XI RPM Analog 1 3 120 -120

40003 M/E FUEL(GOVERNOR) INDEX XI % Analog 1 3 100 0

* NOTE : These signals are included for VDR interface through AMS.

Serial line signals between AutoChief C20/other AMS 2


Kongsberg Maritime
AO-16755-B / 30.January-06

AutoChief C20, Remote Control


System

Standard Spare Parts

Department/Author: Approved by:

Project / Kai Moholt Sverre Mørken

© 2005 KONGSBERG MARITIME AS


All rights reserved
No part of this work covered by the copyright
hereon may be reproduced or otherwise copied
without prior permission from
KONGSBERG MARITIME AS

AC C20 Remote Control System – Standard Spare Parts


Kongsberg Maritime
AO-16755-B / 30.January-06

DOCUMENT STATUS

Issue No. Date/Year Inc. by Issue No. Date/Year Inc. by


A 03.11.05 KM
B 30.01.06 BSM

CHANGES IN DOCUMENT

Issue ECO Paragraph Paragraph Heading/


No. No. No. Description of Change
A AOE-012442 First issue
B AOE-012830 Updated

AC C20 Remote Control System – Standard Spare Parts i


Kongsberg Maritime
AO-16755-B / 30.January-06

AutoChief C20, REMOTE CONTROL SYSTEM


STANDARD SPARE PARTS
Item PART OUTLINE QUANTITY PARTS
No.: DESCRIPTION Each NUMBER
vessel
Inductive 310153
Pick-up
1 XS618B1NBM12 1

If OPU is Required
2 5 1200065

Paper Termic
OPU AC C20
Rolls of 16m

AC C20 Remote Control System – Standard Spare Parts 1