Danfoss HPP Data Sheet
Danfoss HPP Data Sheet
Data sheet
APP Pumps
APP pumps
APP 0.6-1.0 / APP 1.5-3.5 /
APP (W) 5.1-10.2 / APP 11-13 /
APP 0.6-1.0 / APP 1.5-3.5 / APP (W) 5.1-10.2 /
APP 16-22 / APP 21-46
APP 11-13 / APP 16-22 / APP 21-43
ro-solutions.com
hpp.danfoss.com.
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Application examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.1 APP 0.6-1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.2 APP 1.5-3.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.3 APP (W) 5.1-10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.4 APP 11-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.5 APP 16-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.6 APP 21-30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.7 APP 38-46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5. Flow at different rpm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.1 APP 0.6-1.0 flow curves measured at 80 barg ( 1160 psig ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2 APP 1.5-3.5 flow curves at 80 barg (1160 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.3 APP (W) 5.1-10.2 flow curves at 80 barg (1160 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.4 APP 11-13 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.5 APP 16-22 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.6 APP 16-22 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.7 APP 21-30 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.8 APP 21-38 flow curves at 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.9 APP 46 flow curves 60 barg (870 psig) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6 Flushing valve curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.1 APP 0.6–1.0 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.2 APP 1.5–3.5 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.3 APP 5.1-10.2 Flushing valve not available . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.4 APP 11-13 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.5 APP 16–22 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.6 APP 21–46 integrated flushing valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7. Motor requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.1 Calculation factor for APP 0.6-1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.2 Calculation factor for APP 1.5-3.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.3 Calculation factor for APP (W) 5.1-10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.4 Calculation factor for APP 11-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.5 Calculation factor for APP 16-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.6 Calculation factor for APP 21-46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
8. Temperature and corrosion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8.1 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9.1 Filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
9.2 RO system with direct supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
10. Dimensions and connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
10.1 APP 0.6-1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
10.2 APP 1.5-3.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10.3 APP (W) 5.1-10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10.4 APP 11-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
10.5 APP 16-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
10.6 APP 21-26 and APP 30/1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10.7 APP 30/1200 and APP 38-46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
11. Dimensions with motor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
11.1 APP 0.6-3.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
11.2 APP (W) 5.1-10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
11.3 APP 11.0-13.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
11.4 APP 16.0-22.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
11.5 APP 21.0-38.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
11.6 APP 46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
12. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
12.1 Accessories for APP (W) 5.1–10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
12.2 Accessories for APP 11–13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
12.3 Accessories for APP 16–22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
12.4 Accessories for APP 21–46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
13. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
2 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
1. Introduction This data sheet is valid for APP pumps both non Danfoss APP pumps are positive displacement
ATEX and ATEX certified. ATEX certified pumps pumps with axial pistons that move a fixed
are indicated by Ex in the type designation - amount of water in each cycle. Flow is propor
example APP 0.6 Ex. tional to the number of input shaft revolutions
(rpm). Unlike centrifugal pumps, they produce
The Danfoss range of APP high-pressure pumps the same flow at a given speed no matter what
is designed according to EN 809 for use in RO the discharge pressure.
applications with low viscosity and corrosive
fluids such as: Below sectional drawing is an example of an
• Sea water APP pump. The sectional drawing for the specific
• Brackish water pump sizes are to be found in the pump
• Waste water (APP W) instruction.
1: Shaft sealing
2: Port flange
3: Bleeding plug
4: Retainer plate
5: Piston/shoe
6: Valve plate
7: Swash plate
8: Cylinder barrel
9: Springs
10: Port plate
11: Flushing valve
(not available on
APP 5.1-10.2)
12: Housing
13: Tail stock screws
14: Drain plug
3. Application examples Danfoss APP pumps are built into a broad range • obile systems for humanitarian and
M
of RO desalination plants around the world: military organizations
• Onboard systems for ships and yachts
• ontainerized solutions for hotels, resorts
C • Offshore platforms for the oil and gas
and residences on islands and in coastal industry
regions • Municipal and regional waterworks
AI274333290009en-000701 | 11.2021 3
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Media 3) °C 2 - 50 2 - 50 2 - 50
temperature °F 36 - 122 36 - 122 36 - 122
1)
For lower and higher pressure, please contact Danfoss.
5)
A-weighted sound pressure level at 1 m from the pump unit
2)
For speeds above 3000 rpm the pump must be boosted at a pressure surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
of 2-5 barg (29- 72.5 psig). measurements are performed acc. to EN ISO 3744:2010 on a motor-
3)
Dependent on the NaCI concentration - see chapter 8. pump unit at max. pressure and speed.
4)
Category 2, Zone 1 or Category 3, Zone 2.
6)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
4 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Media 3) °C 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 36 - 122 36 - 122 36 - 122 36 - 122 36 - 122 36 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122
kg 8.6 8.6 8.6 8.6 8.6 8.6
Weight (dry)
lb 17 17 17 17 17 17
Sound
dB(A) 77 77 77 81 81 81
pressure level5)
1)
For lower and higher pressure, please contact Danfoss. 5)
A-weighted sound pressure level at 1 m from the pump unit
2)
For speeds above 3000 rpm the pump must be boosted at a pressure surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
of 2-5 barg (29- 72.5 psig). measurements are performed acc. to EN ISO 3744:2010 on a motor-
3)
Dependent on the NaCI concentration - see chapter 8. pump unit at max. pressure and speed.
4)
Category 2, Zone 1 or Category 3, Zone 2. 6)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
AI274333290009en-000701 | 11.2021 5
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Media 3) °C 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122
kg 30 30 30 30 30
Weight (dry)
lb 66 66 66 66 66
Sound pressure
dB(A) 78 78 78 78 78
level5)
6 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Media 2) °C 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122
kg 78 78 78 78
Weight (dry)
lb 172 172 172 172
Sound pressure
dB(A) 85 85 85 85
level4)
1)
For lower and higher pressure, please contact Danfoss. 4)
A-weighted sound pressure level at 1 m from the pump unit
2)
Dependent on the NaCI concentration - see chapter 8. surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
4)
Category 2, Zone 1 or Category 3, Zone 2. measurements are performed acc. to EN ISO 3744:2010 on a motor-
pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
AI274333290009en-000701 | 11.2021 7
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Pump size APP 16/1200 APP 16/1500 APP 17/1200 APP 17/1500 APP 19/1200 APP 19/1500 APP 22/1200 APP 22/1500
Code number APP 180B3254 180B3250 180B3255 180B3251 180B3256 180B3252 180B3257 180B3253
Code number APP ATEX 3)
180B3264 180B3260 180B3265 180B3261 180B3266 180B3262 180B3267 180B3263
Geometric cm³/rev. 234.6 188.3 253.3 197.5 272.3 219.7 310.6 253.3
displacement in³/rev. 14.32 11.49 15.46 12.05 16.62 13.41 18.95 15.46
Pressure
Max. outlet 1) barg 83 70 83 70 83 70 83 70
pressure
continuous psig 1200 1015 1200 1015 1200 1015 1200 1015
Inlet pressure barg 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5
continuous psig 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5
Media 2) °C 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122
kg 78 78 78 78 78 78 78 78
Weight (dry)
lb 172 172 172 172 172 172 172 172
Sound pressure
dB(A) 84 84 84 84 84 84 84 84
level4)
Footprint with m² 0.54 0.58 0.59 0.59 0.76 0.76 0.80 0.80
IEc motor5) foot² 5.81 6.26 6.35 6.35 8.18 8.18 8.61 8.61
Typical motor size
Max. speed at
kW 37.0 37.0 45.0 55.0
max. pressure
1200 rpm at
HP 60.0 60.0 75.0 75.0
max. pressure
Torque at max. Nm 316 223 343 234 372 263 426 305
outlet pressure lbf-ft 233 165 253 173 275 194 314 225
1)
For lower and higher pressure, please contact Danfoss. 4)
A-weighted sound pressure level at 1 m from the pump unit
2)
Dependent on the NaCI concentration - see chapter 8. surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
4)
Category 2, Zone 1 or Category 3, Zone 2. measurements are performed acc. to EN ISO 3744:2010 on a motor-
pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
8 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Pump size APP 21/1200 APP 21/1500 APP 24/1200 APP 24/1500 APP 26/1200 APP 26/1500 APP 30/1200 APP 30/1500
Code number APP 180B3051 180B3052 180B3054 180B3055 180B3056 180B3057 180B3060 180B3062
Code number APP ATEX 3)
180B3151 On request 180B3154 180B3155 On request On request On request On request
Geometric cm³/rev. 308.5 256 362 282 389 308.5 444 362
displacement in³/rev. 18.83 15.62 22.09 17.21 23.74 18.83 27.09 22.09
Pressure
Max. outlet 1) barg 83 83 83 83 83 83 83 83
pressure
continuous psig 1200 1200 1200 1200 1200 1200 1200 1200
Inlet pressure barg 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5
continuous psig 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5 29 - 72.5
Media 2) °C 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122 35.6 - 122
Ambient °C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50
temperature °F 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122 32 - 122
kg 105 105 105 105 105 105 105 105
Weight (dry)
lb 231 231 231 231 231 231 231 231
Sound pressure
dB(A) 85 85 85 85 85 85 85 85
level4)
Footprint with m² 0.76 0.76 0.80 0.80 0.83 0.83 0.83 0.83
IEC motor5) foot² 8.18 8.18 8.61 8.61 8.93 8.93 8.93 8.93
Typical motor size
Max. speed at
kW 55.0 75.0 55.0 75.0 75.0 75.0 90.0 90.0
max. pressure
1200 rpm at
HP 75.0 100.0 100.0 125.0
max. pressure
Torque at max. Nm 418 355 490 388 527 426 608 498.68
outlet pressure lbf-ft 308 262 361 286 389 314 449 367.81
1)
For lower and higher pressure, please contact Danfoss. 4)
A-weighted sound pressure level at 1 m from the pump unit
2)
Dependent on the NaCI concentration - see chapter 8. surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
4)
Category 2, Zone 1 or Category 3, Zone 2. measurements are performed acc. to EN ISO 3744:2010 on a motor-
pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
AI274333290009en-000701 | 11.2021 9
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Media 2) °C 2 - 50 2 - 50
temperature °F 35.6 - 122 35.6 - 122
1)
For lower and higher pressure, please contact Danfoss.
4)
A-weighted sound pressure level at 1 m from the pump unit
2)
Dependent on the NaCI concentration - see chapter 8. surfaces (reference box) acc. to EN ISO 20361 section 6.2. The noise
4)
Category 2, Zone 1 or Category 3, Zone 2. measurements are performed acc. to EN ISO 3744:2010 on a motor-
pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
6)
For operation at speed below 1700 RPM , min. pressure can be
reduced to 2.5 barg
10 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
5. Flow at different rpm If the flow required and the rotation speed (rpm) of the Furthermore, these diagrams shows that the
pump is known, it is easy to select the pump fitting the flow can be changed by changing the rotation
application best by using the diagrams below. speed of the pump. The flow/rpm ratio is
constant, and the “required” flow can be
obtained by changing the rotation speed to a
corresponding value. Thus, the required rpm
can be determined as:
m3/h
m1.4
3
/h
1.3
1.4 APP 1.0
1.2
1.3
1.1 APP 1.0
1.2
1.0 APP 0.8
1.1
0.9
1.0 APP 0.8
0.8 APP 0.6
0.9
0.7
0.8 APP 0.6
0.6
0.7
0.5
0.6
0.4
0.5
0.3
0.4
0.2
0.3
0.1
0.2 rpm
0
0.1
50 50
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
00 00
0
00 00
00 00
00 00
rpm
70
90
34 34
0
19 19
29 29
21 21
25 25
31 31
33 33
13 13
15 15
27 27
11 11
17 17
23 23
0
0
70
90
gpm
5.5
gpm APP 1.0
5.0
5.5 APP 1.0
4.5
5.0 APP 0.8
4.0
4.5
APP 0.8
3.5
4.0 APP 0.6
3.0
3.5 APP 0.6
2.5
3.0
2.0
2.5
1.5
2.0
1.0
1.5
0.5
1.0
0 rpm
0.5
00 00
0
00
00
00
00 00
00 00
00
00
00
00
00
00
00
rpm
70
90
11 11
17
23
29
13 13
15 15
19
21
25
27
31
33
34
0
0
00
00
00
00
00
00
00
00
00
00
70
90
17
23
29
19
21
25
27
31
33
34
AI274333290009en-000701 | 11.2021 11
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
m3/h
4.5
m3/h
4.0
4.5
APP 3.5 APP 3.0
3.5
4.0
3.0 APP 3.5 APP 3.0
3.5
APP 2.5
2.5
3.0 APP 2.2
APP 2.5 APP
2.0
2.5 APP 1.8
2.2
APP 1.5
1.5
2.0 APP 1.8
APP 1.5
1.0
1.5
0.5
1.0
0
0.5 rpm
0
00
0
00
00
00
00
00
00
00
00
00
00
00
50
70
90
11
17
23
29
13
15
19
21
25
27
31
33
34
0 rpm
0
00
0
00
00
00
00
00
00
00
00
00
00
00
50
70
90
11
17
23
29
13
15
19
21
25
27
31
33
34
gpm
18.0
gpm
16.0
18.0 APP 3.0
APP 3.5
14.0
16.0
APP 3.5 APP 3.0
12.0
14.0 APP 2.5 APP 2.2
10.0
12.0
APP 2.5 APP 1.8
2.2
8.0 APP 1.5
10.0
APP 1.8
6.0
8.0 APP 1.5
4.0
6.0
2.0
4.0
0 rpm
2.0
0
00
0
00
00
00
00
00
00
00
00
00
00
00
50
70
90
11
17
23
29
rpm
13
15
19
21
25
27
31
33
34
0
0
00
0
00
00
00
00
00
00
00
00
00
00
00
50
70
90
11
17
23
29
13
15
19
21
25
27
31
33
34
12 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
m3/h
11.0
m3/h APP (W)10.2
10.0
11.0
9.0 APP (W)10.2
10.0
APP (W) 8.2
8.0
9.0
7.0 APP (W) 7.2
APP (W) 8.2
8.0 APP (W) 6.5
6.0
7.0 APP (W) 7.2
5.0 APP (W) 5.1
6.5
6.0
4.0
5.0 APP (W) 5.1
3.0
4.0
2.0
3.0
1.0
2.0
0 rpm
1.0
00
00
0
00
00
00
00
00
00
00
70
80
90
11
14
17
10
12
13
15
16
18
0 rpm
00
00
0
00
00
00
00
00
00
00
70
80
90
11
14
17
10
12
13
15
16
18
gpm
gpm
45.0 APP (W) 10.2
40.0
45.0 APP (W) 10.2
APP (W) 8.2
35.0
40.0
APP
APP (W)
(W) 7.2
8.2
30.0
35.0
APP (W) 6.5
25.0 APP (W) 7.2
30.0
APP (W)
APP (W) 5.1
6.5
20.0
25.0
APP (W) 5.1
15.0
20.0
10.0
15.0
5.0
10.0 rpm
00
00
0
00
00
00
00
00
00
00
70
80
90
11
14
17
10
12
13
15
16
18
5.0 rpm
00
00
0
00
00
00
00
00
00
00
70
80
90
11
14
17
10
12
13
15
16
18
AI274333290009en-000701 | 11.2021 13
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
m3/h
15.0
m3/h
14.0 APP 13/1500
15.0 APP 13/1200
13.0
14.0 APP 13/1500
12.0 APP 13/1200
13.0 APP 11/1200 APP 11/1500
11.0
12.0
10.0 APP 11/1200 APP 11/1500
11.0
9.0
10.0
8.0
9.0
7.0
8.0
6.0
7.0
5.0
6.0
4.0 rpm
5.0
0
00 000
00 100
00 200
00 300
00 400
00 500
70
80
90
4.0 rpm
1
1
0
0
70
80
90
10
11
12
13
14
15
gpm
65.0
gpm
60.0
65.0 APP 13/1500
APP 13/1200
55.0
60.0 APP 13/1500
APP 13/1200
50.0
55.0 APP 11/1200 APP 11/1500
45.0
50.0 APP 11/1200 APP 11/1500
40.0
45.0
35.0
40.0
30.0
35.0
25.0
30.0
20.0
25.0 rpm
0
00 000
00 100
0
00 200
00 300
00 400
00 500
70
80
90
20.0 rpm
1
1
0
0
70
80
90
10
11
12
13
14
15
14 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
m3/h
22.0 APP 22/1200
m 3
/h
20.0
22.0 19/1200
APP 22/1200
18.0 APP 17/1200
20.0 APP 16/1200
16.0 APP 19/1200
18.0 APP 17/1200
14.0 APP 16/1200
16.0
12.0
14.0
10.0
12.0
8.0
10.0
6.0 rpm
8.0
00
00
00
0
0
70
80
90
12
10
11
6.0 rpm
00
gpm
00
00
0
0
70
80
90
12
10
11
APP 22/1200
90.0
gpm
80.0 APP 22/1200
19/1200
90.0
APP 17/1200
70.0 APP
APP 16/1200
19/1200
80.0
APP 17/1200
60.0 APP 16/1200
70.0
50.0
60.0
40.0
50.0
30.0 rpm
40.0
00
00
00
0
0
70
80
90
12
10
11
30.0 rpm
00
00
00
0
0
70
80
90
12
10
11
AI274333290009en-000701 | 11.2021 15
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
m3/h
m 3
/h
22.0 APP 22/1500
22.0 APP 22/1500
20.0
20.0 APP 19/1500
18.0 APP 19/1500
18.0 APP 17/1500
16.0 16/1500
APP 17/1500
16.0 APP 16/1500
14.0
14.0
12.0
12.0
10.0
10.0
8.0
8.0
6.0 rpm
6.0 rpm
00 00
00 00
0 0
0 0
0 0
00 00
00 00
00 00
00 00
70 70
80 80
90 90
11 11
14 14
10 10
12 12
13 13
15 15
gpm
gpm APP 22/1500
90.0 APP 22/1500
90.0
APP 19/1500
80.0
APP 19/1500
80.0
APP 17/1500
70.0 16/1500
APP 17/1500
70.0 APP 16/1500
60.0
60.0
50.0
50.0
40.0
40.0
30.0 rpm
30.0 rpm
00 00
00 00
0 0
0 0
0 0
00 00
00 00
00 00
00 00
70 70
80 80
90 90
11 11
14 14
10 10
12 12
13 13
15 15
16 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
m3/h
32.0
APP 30/1200
m3/h
30.0
32.0
28.0 APP 30/1200
30.0 APP 26/1200
26.0
28.0 APP 24/1200
24.0 APP 26/1200
26.0
APP 24/1200
22.0 APP 21/1200
24.0
20.0
22.0 APP 21/1200
18.0
20.0
16.0
18.0
14.0
16.0
12.0 rpm
14.0
00
00
00
0
0
70
80
90
11
12
10
12.0 rpm
00
00
00
0
0
70
80
90
11
12
10
gpm
140.0
gpm APP 30/1200
130.0
140.0
120.0 APP 30/1200
130.0 APP 26/1200
110.0 APP 24/1200
120.0 APP 26/1200
100.0
110.0 APP 24/1200
APP 21/1200
90.0
100.0
80.0 APP 21/1200
90.0
70.0
80.0
60.0
70.0
50.0 rpm
60.0
00
00
00
0
0
70
80
90
11
12
10
50.0 rpm
00
00
00
0
0
70
80
90
11
12
10
AI274333290009en-000701 | 11.2021 17
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
m3/h
m40.0
3
/h APP 38/1500
40.0
37.5 APP 38/1500
37.5
35.0
35.0
32.5 APP 30/1500
32.5
30.0 APP 30/1500
27.5
30.0 APP 26/1500
27.5
25.0 APP 26/1500
APP 24/1500
25.0
22.5 APP
APP 24/1500
21/1500
22.5
20.0 APP 21/1500
20.0
17.5
17.5
15.0
15.0
12.5
12.5
10.0 rpm
00 00
00 00
00 00
00 00
00 00
00 00
0 0
0 0
10.0 rpm
70 70
80 80
11 11
12 12
15 15
10 10
13 13
14 14
gpm
170.0
gpm APP 38/1500
160.0
170.0 APP 38/1500
160.0
150.0
140.0
150.0 APP 30/1500
140.0
130.0 APP 30/1500
120.0
130.0
APP 26/1500
110.0
120.0 APP 26/1500
24/1500
APP
110.0
100.0 APP 21/1500
APP 24/1500
90.0
100.0 APP 21/1500
90.0
80.0
70.0
80.0
60.0
70.0
60.0
50.0
50.0
40.0 rpm
rpm
00 00
00 00
00 00
00 00
00 00
00 00
0 0
0 0
0 0
40.0
70 70
80 80
90 90
12 12
15 15
10 10
11 11
13 13
14 14
18 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
m³/h
50.00
50,00
47.50
47,50
APP 46/1780
45.00
45,00
42.50
42,50
40.00
40,00
37.50
37,50
35.00
35,00
32.50
Flow [m3/h]
32,50
30.00
30,00
27.50
27,50
25.00
25,00
22.50
22,50
20.00
20,00
17.50
17,50
15.00
15,00
12.50
12,50
10.00
10,00 rpm
0
0
0
0
0
0
0
0
0
0
130
140
0
180
170
120
150
110
160
90
70
10
80
Speed [RPM]
gpm
210.0
210,00
200.0
200,00
APP 46/1780
190.0
190,00
180.0
180,00
170.0
170,00
160.0
160,00
150.0
150,00
140.0
140,00
Flow [gpm]
130.0
130,00
120.0
120,00
110,00
110.0
100.0
100,00
90.0
90,00
80,00
80.0
70.0
70,00
60.0
60,00
50.0
50,00
40.0
40,00 rpm
0
0
0
0
0
0
0
0
180
0
0
140
150
130
170
110
160
120
80
90
70
10
Speed [RPM]
AI274333290009en-000701 | 11.2021 19
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
6 Flushing valve curves All pumps except APP (W) 5.1 - 10.2 are supplied
with an integrated flushing valve that allows the
fluid to flow from inlet to the outlet, when the
pump is not running.
Pressure [barg]
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0 Flow [l/min]
0
10
12
14
16
18
6.2 APP 1.5–3.5 integrated flushing valve
Pressure [barg]
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0 Flow [l/min]
0
10
12
14
16
18
20 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Pressure [barg]
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0 Flow [l/min]
0
20
40
60
80
0
10
12
14
16
18
6.5 APP 16–22 integrated flushing valve
Pressure [barg]
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0 Flow [l/min]
0
50
0
45
10
15
20
25
30
35
40
AI274333290009en-000701 | 11.2021 21
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Pressure [barg]
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0 Flow [l/min]
0
0
10
20
30
40
50
60
22 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
7. Motor requirements The power requirements can be determined using one of the following guiding equations:
1 hp = 0.75 kW
1 gpm = 3.79 l/min
1 m3/h = 4.40 gpm
1 kW = 1.34 hp
1 l/min = 0.26 gpm
1 gpm = 0.23 m3/h
7.1 Calculation factor for APP 0.6-1.0 7.5 Calculation factor for APP 16-22
AI274333290009en-000701 | 11.2021 23
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
8. Temperature and 8.1 Temperature stop in order to minimize the risk of crevice
corrosion corrosion.
Fluid temperature:
The chart below illustrates the corrosive
Min. +2°C to max. +50°C
resistance of different types of stainless steel
(Min. +35.6°F to max. +122°F)
related to NaCl concentration and temperature.
Ambient temperature: The APP water pump is made of Duplex and
Min. +2°C to max. +50°C Super Duplex.
(Min. +35.6°F to max. +122°F) If the water pump is operated above the Duplex
line, always flush water pump with fresh water at
In case of lower operating temperatures, please operation stop in order to minimize the risk of
contact Danfoss High Pressure Pumps.operation crevice corrosion.
50
316L
40
30
20 -
100 1000 10 000 100 000 CI
ppm
160 1600 16000 160000 NaCI
ppm
9. Installation See example below on how to mount the pump If alternative mounting is required. please
and connect it to an electric motor or combus- contact your Danfoss sales representative for
tion engine (special coupling). further information.
A: Pump
B: Bell housing
C: Flexible coupling
D: Motor shaft
E: Motor
A
B
C D E
24 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Hoses:
Noise e) Use flexible hoses (4) to minimize
Since the pump unit is typical mounted on a vibrations and noise. Please consult the
frame or bell housing the overall noise level can Danfoss Hoses and hose fittings data
only be determined for a complete system. To sheet (521B0909) for guidance.
minimize vibrations and noise throughout the
system, it is therefore very important to mount Inlet pressure:
the pump unit correctly on a frame with f) In order to eliminate the risk of cavitation
anti-vibration-dampeners, and to use flexible and other pump damage, pump inlet
hoses rather than metal pipes where possible. pressure must always be maintained
according to specifications described in
The noise level is influenced by: item 4 about technical data.
• Pump speed:
High rpm generates more fluid/structure Flushing valve:
borne pulsations/vibrations than low rpm, g) For easy system filling and flushing, an
because of higher frequency. integrated flushing valve (6) is in
• Discharge pressure: the APP pump (except APP (W) 5.1-10.2).
High pressure generates more noise than
low pressure. Non-return valve:
• Pump mounting: h) A non-return valve (7) in outlet can be
Rigid mounting generates more noise than installed in order to avoid backspin of the
flexible mounting, because of structure- pump. The volume of water in the
borne vibrations. Be sure to use dampers membrane vessel works as an accumulator
when mounting. and will send flow backwards in case of the
• Connections to pump: pump stops momentarily.
Pipes connected directly to the pump make
more noise than flexible hoses, because of
structure-borne vibrations.
AI274333290009en-000701 | 11.2021 25
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
Media filter
9 3
M
PI
PI 1 PI 1 PI PT
Feed 2 7
PI
Permeate
4
PI
5 6
Fresh water
permeat flush
Brine
26 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
AI274333290009en-000701 | 11.2021 27
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
28 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
AI274333290009en-000701 | 11.2021 29
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
30 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
AI274333290009en-000701 | 11.2021 31
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
32 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
AI274333290009en-000701 | 11.2021 33
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
A mm B mm C mm D mm E mm F mm G mm H mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch) (inch) (inch)
200 245 90 140 100 265 100 131
APP 0.6 1.5 kW, IEC 90S-2
(7.87) (9.64) (3.54) (5.51) (3.94) (10.43) (3.94) (5.16)
200 245 90 140 125 290 100 131
APP 0.8 2.2 kW, IEC 90L-2
(7.87) (9.64) (3.54) (5.51) (4.92) (11.42) (3.94) (5.16)
250 260 100 160 140 325 120 131
APP 1.0 3.0 kW, IEC 100L-2
(9.84) (10.23) (3.94) (6.30) (5.51) (12.80) (4.72) (5.16)
250 260 100 160 140 325 120 166
APP 1.5 3.0 kW, IEC 100L-2
(9.84) (10.23) (3.94) (6.30) (5.51) (12.80) (4.72) (6.54)
250 290 112 190 140 340 120 166
APP 1.8 4.0 kW, IEC 112M-2
(9.84) (11.42) (4.41) (7.48) (5.51) (13.39) (4.72) (6.54)
300 338 132 216 140 403 144 166
APP 2.2 5.5 kW, IEC 132S1-2
(11.81) (13.31) (5.20) (8.50) (5.51) (15.87) (5.67) (6.54)
300 338 132 216 178 403 144 166
APP 2.5 7.5 kW, IEC 132S2-2
(11.81) (13.31) (5.20) (8.50) (7.01) (15.87) (5.67) (6.54)
350 422 160 254 210 505 188 166
APP 3.0 11 kW, IEC 160M1-2
(13.78) (17.40) (6.30) (10.0) (8.27) (19.88) (7.40) (6.54)
350 422 160 254 210 505 188 166
APP 3.5 11 kW, IEC 160M1-2
(13.78) (17.40 (6.30) (10.0) (8.27) (19.88) (7.40) (6.54)
34 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
A mm B mm C mm D mm E mm F mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch)
350 437 160 254 210 498
APP 5.1 11 kW, IEC 160 M-4
(13.78) (17.20) (6.30) (10.0) (8.27) (19.61)
350 437 160 254 254 542
APP 6.5 15 kW, IE2 160 L-4
(13.78) (17.20) (6.30) (10.0) (10.0) (21.34)
350 437 160 254 254 542
APP 7.2 15 kW, IE2 160 L-4
(13.78) (17.20) (6.30) (10.0) (10.0) (21.34)
350 473 180 279 241 578
APP 8.2 18.5 kW, IE2 180 M-4
(13.78) (18.62) (7.09) (10.98) (9.49) (22.76)
350 473 180 279 279 616
APP 10.2 22 kW, IEC 180 L-4
(13.78) (18.62) (7.09) (10.98) (10.98) (24.25)
400 513 200 318 305 659
APP 10.2 30 kW, IEC 200 L-4
(15.75) (20.20) (7.87) (12.52) (12.01) (25.94)
AI274333290009en-000701 | 11.2021 35
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
A mm B mm C mm D mm E mm F mm G mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch) (inch)
350 473 180 279 241 578 204
APP 11 22 kW, IEC 180L-4
(13.78) (18.62) (7.09) (10.98) (9.49) (22.76) (8.03)
400 513 200 318 305 659 204
APP 11 30 kW, IEC 200L-4
(15.75) (20.20) (7.87) (12.52) (12.01) (25.94) (8.03)
450 561 225 356 286 667 234
APP 13 37 kW, IEC 225S-4
(17.72) (22.09) (8.86) (14.02) (11.26) (26.26) (9.21)
36 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
A mm B mm C mm D mm E mm F mm
G mm
Pump (inch) (inch) (inch) (inch) (inch) (inch) IEC Electric motor
(inch)
[P] [HD] [H] [A] [B]) [LB]
450 560 225 356 286 675 262
APP 16 37 kW, IEC 225 S4
(17.72) (22.05) (8.86) (14.02) (11.26) (26.57) (10.31)
450 560 225 356 311 705 262
APP 17 45 kW, IEC 225 M4
(17.72) (22.05) (8.86) (14.02) (12.24) (27.76) (10.31)
550 615 250 406 349 775 265
APP 19 55 kW, IEC 250 M4
(21.63) (24.22) (9.84) (15.98) (13.74) (30.51) (10.43)
550 680 280 457 368 835 265
APP 22 75 kW, IEC 280 S4
(21.63) (26.77) (11.02) (17.99) (14.48) (32.87) (10.43)
AI274333290009en-000701 | 11.2021 37
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
A mm B mm C mm D mm E mm F mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch)
550 635 250 406 349 770
APP 21-24 55 kW, IEC 250 M-4
(21.65) (25.0) (9.84) (15.98) (13.74) (30.31)
550 693 280 457 368 845
APP 24-26 75 kW, IEC 280 S-4
(21.65) (27.28) (11.02) (17.99) (14.49) (33.27)
550 693 280 457 419 895
APP 26-38 90 kW, IEC 280 M-4
(21.65) (27.28) (11.02) (17.99) (16.50) (35.24)
38 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
11.6 APP 46
A mm B mm C mm D mm E mm F mm
Pump IEC Electric motor
(inch) (inch) (inch) (inch) (inch) (inch)
660 861 315 508 406 1038
APP 46 110 kW, IEC 315 S-4
(25.98) (33.90) (12.40) (20.00) (15.98) (40.87)
Due to the design and dimensions of an APP 46 If this dampening flange for some reason is
pump, bell housing and IEC motor, a dampening deselected, an extension for the non-return
flange on the bell housing is standard when an valve may be needed in order to mount the pipe
IEC 315 motor is selected. or hose with Victaulic clamps. For details and
relevant accessories, please contact Danfoss.
AI274333290009en-000701 | 11.2021 39
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
40 AI274333290009en-000701| 11.2021
Data sheet | APP 0.6-46 / APP (W) 5.1-10.2 pumps
13. Service
Warranty Pump shutdown:
Danfoss APP pumps are designed for long The APP pumps are made of Duplex/Super
operation, low maintenance and reduced Duplex materials with excellent corrosion
lifecycle costs. properties. It is, however, always recommended
to flush the pump with freshwater when the
Provided that the pump has been running system is shut down.
according to the Danfoss specifications, Danfoss When stopping the pump for more than 1 day
guarantees 8,000 hours service-free operation, flush the pump with permeate by rotating the
however, max. 18 months from date of pump for 10 sec. Flushing through the flushing
production. valve of the pump without rotating the pump is
not enough for cleaning the inside of the pump.
If Danfoss recommendations concerning The pump can be flushed with biocide like the
system-design are not followed, it will strongly membranes. The biocide must be compatible
influence the life of the APP pumps. with the materials used in our pumps.
Other factors that affect pump performance and
lifetime include:
- Running the pump at speed outside Repair assistance
specifications. In case of irregular function of the APP pump,
- Supplying the pump with water at please contact Danfoss High Pressure Pumps.
temperature higher than recommended.
- Running the pump at inlet pressure outside
specifications.
- Running the pump at outlet pressure
outside the specifications.
Maintenance
Periodic inspections are required to ensure worn
parts (if any), are replaced in due time. Opera-
tional conditions such as water quality should be
taken into consideration when determining the
frequency of the inspections. Danfoss recom-
mends yearly inspections.
It is recommended to order the purpose-
designed tool kit.
AI274333290009en-000701 | 11.2021 41
© Danfoss | DCS (im) | 2021.11 AI274333290009en-000701 | 42