MEENAAR GLOBAL CONSULTANTS LLP

{Formerly known as Meenaar (Global) Consultants}

INSPECTION RELEASE NOTE


SHT. 1 OF 2

No.: I R N 2 2 0 1 3 6 1 0 DATE: 2 7 0 1 2 2 Rev. 00

LOCATION : Juchandra, Palghar (Maharashtra) MGC OFFICE : New Delhi


CLIENT : M/s. Assam Gas Company Limited PMC : VCS Project Consultants Private Limited
END USER : M/s. Assam Gas Company Limited JOB No. :
PROJECT : Procurement of Flow Meters for Nambor-Golaghat-Numaligarh Area Gas Pipeline Project

P.O. NO.: AGCL/GMB/PMC- GHT/Flow Meter/2021/93 DATE: 2 8 0 6 2 1

P.O. Amendments: 0 0 ORDER STATUS: C P

VENDOR : M/s Sick India Pvt Ltd LOCATION : Juchandra, Palghar (Maharshtra)
SUB -VENDOR: NA LOCATION : NA
VENDOR REF. : NA SUB ORDER No.: NA
Following item(s) inspected as per approved documents & client specification and released for coating:
Cumulative
PO Sr. ITEM Qty.
DESCRIPTION UNIT PO Qty. Qty. QTY. Balance
No. No. Released
Released
Design, Engineering, Supply, testing and
inspection, assembly at shop, integration,
internal testing, packaging, shipping,
documentation, supervision of installation
and commissioning Ultrasonic type flow
meter with line size of 8” and capacity of
1 1 250000 SCMD, Bi -directional, Multi path (Nos.) 02 02 02 Nil
(Minimum 4 path), along with instruments
like PT, TE/TT, Panel, Mounted flow
computer and necessary accessories, erection
hardware required in accordance with data
sheet and standard specification as per
techanical tender.
Design, Engineering, Supply, testing and
inspection, assembly at shop, integration,
internal testing, packaging, shipping,
documentation, supervision of installation
and commissioning Ultrasonic type flow
meter with line size of 6” and capacity of
2 2 250000 SCMD, Bi -directional, Multi path (Nos.) 01 01 01 Nil
(Minimum 4 path), along with instruments
like PT, TE/TT, Panel, Mounted flow
computer and necessary accessories, erection
hardware required in accordance with data
sheet and standard specification as per
techanical tender.
Spare Part
Pressure Transmitter with 2Valve
1 1 Manifold :Accuracy 0.025%, Make Honey (Nos.) 01 01 01 Nil
well
Temperature Transmitter :Accuracy +/-
2 2
0.10%, Make Honey well (Nos.) 01 01 01 Nil
1-1/2” 600# Thermo well MOC : SS316,
3 3 Make Tempsens
(Nos.) 01 01 01 Nil
Temperature elements(RTD) 4 wire
4 4 duplex, Make Tempsens (Nos.) 01 01 01 Nil
MEENAAR GLOBAL CONSULTANTS LLP
{Formerly known as Meenaar (Global) Consultants}

INSPECTION RELEASE NOTE


SHT. 2 OF 2

(AA) Reference Documents:


1. P. O. No. AGCL/GMB/PMC- GHT/Flow Meter/2021/93 Date: 28-June-2021
2. Approved QAP No. J4-21-0191-P2-01 / Rev No.: 01 / Rev. Date 03.08.2021, J4-21-0191-P2-01-004/ Rev No-00/Rev. Date
23.09.2021,
3. Please refer detailed inspection report no. MGC/SICK/DK/21/IR/01 Rev.01 Dated: 27.01.2022 is correlated with this Inspection
Certificate.

(BB) Following Stages witnessed / Random witnessed:


1. Witness of metering skid assembly and instruments, Fat as per fat manual, pneumatic leak test at 7 bar for 15minutes &
verification of completeness report as per approved QAP (Clause 5.1, 5.2, 5.3 & 5.5)- found Satisfactory.
2. Witness of Functional test (Power on checked & Connectivity with flowgate software completed) as per QAP
(Clause 2.1 & 2.2) - found satisfactory.
3. Witnessed of visual & dimension – found satisfactory.

(CC) Following Documents reviewed:


1. Reviewed material identification of Brought out, material identification of piping spools, welding, NDT & Testing for
Interconnecting Piping, painting report, design and calculation, Material TC, calibration, Inspection and test report, as built GA
drawing and P & ID QAP & client specification and found order.
2. Reviewed MTC EN10204 3.1 & Test report identification of material /physical & chemical test report, Charpy Impact test report,
hydro test report, Review of Internal calibration report of zero flow test, calibration lab report of wet calibration as well as review of
statutory certificates per approved QAP & client specification and found in order.
3. Manufacturer’s Test Certificate reviewed and found in order..

INSPECTION DATE (s) : 27.01.2022 INSPECTING AUTHORITY’S


Name of Surveyor : Deepak Kumar SEAL / SIGNATURE
IDENTIFICATION MARKS: Nil

Disclaimer: This inspection release note is issued without prejudice to contractual obligation of the supplier and does not relieve him from the guarantees
and obligations set forth in purchase order and attachment / amendments.