You are on page 1of 2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

NOTES:

1. X: F (FLOW)
COMPRESSORS PUMPS MISCELLANEOUS AIR COOLER FR (FLOW RATIO)
L (LEVEL)
A P (PRESSURE)
PD (PRESSURE DIFFERENCE)
A
Q (QUALITY)
S (SPEED)
CENTRIFUGAL COMPRESSOR
FINNED TUBE EXCHANGER T (TEMPERATURE)
WITH INLET GUIDE VANE
TD (TEMPERATURE DIFFERENCE)
C H (HAND (MANUALLY) OPERATED)
CENTRIFUGAL PUMP
FLARE STACK

AIR COOLER
B (WITH LOUVER IF REQUIRED) B
MULTI STAGES
CENTRIFUGAL COMPRESSOR
C C RP RECIPROCATING PUMP

INCINERATOR
HEAT EXCHANGERS
C C
RC
RECIPROCATING COMPRESSOR
AIR DRIVEN PUMP

PLATE HEAT EXCHANGER

DRIVERS & TURBINES


CONICAL STRAINER

G GENERATOR

D PIPING VALVES AND FITTINGS D


STRAINER
M ELECTRICAL MOTOR
NORMALLY VALVE OPEN DURING
OPERATION MULTI STREAM HEAT EXCHANGER

GAS TURBINE NORMALLY VALVE CLOSED FLAME ARRESTOR


DURING OPERATION
NC

BLOWER FLEXIBLE HOSE


E HOSE COUPLING
E
VAPORIZER
FURNACES & HEATERS REMOVABLE SPOOL PIECE
M
AGITATOR MIXER

ATMOSPHERIC VENT WITH HOOD

HEATER
F FURNACE (USING UTILITY MEDIUM) F
ATMOSPHERIC VENT
PACKAGE

DRAIN

TOPSIDES
ELECTRIC HEATER INTERFACE
HULL (DECK) COOLER
MAJOR LINE (USING UTILITY MEDIUM)

G G
ELECTRIC MINOR LINE
SC
SAMPLING CONNECTION
ELECTRIC ELECTRIC HEATER BLIND FLANGE
HEATER (STAB IN)

SHELL AND TUBE EXCHANGER


STATIC MIXER

H WASTE HEAT RECOVERY HEATER H


IN-LINE SILENCER

KETTLE TYPE HEAT EXCHANGER


TANKS
DWG NO. TITLE
REFERENCE DRAWINGS
CONICAL BOTTOM TANK INSTRUMENTATION FLOW PRIMARY ELEMENTS &
I OTHER DEVICES I
01 11-SEP-2023 ISSUED FOR DESIGN T.SUMI M.NAKANE G.SAITO
00 01-FEB-2023 ISSUED FOR REVIEW T.SUMI M.NAKANE G.SAITO
INSTRUMENT SIGNAL
REV DATE ISSUE PURPOSE PREP'D CHK'D APR'D
HULL TANK REVISIONS

XC CONTROLLER (NOTE 1)

FILTERS AND RECEIVING EQUIPMENT


J XI INDICATOR (NOTE 1) J
BASKET FILTER
PFD - GENERAL - LEGEND SHEET 1
XY CALCULATOR (NOTE 1)
(TOPSIDES AND RELATED UTILITIES)

RO RESTRICTION ORIFICE
PCWBS SHEET SCALE
NONE 01 of 01 NONE
COMPANY NAME COMPANY ENGINEER
CARTRIDGE FILTER
K PORT SELECTOR SWITCH
UTM FLNG Limited Kellogg Brown & Root Limited K
PROJECT NAME JOB CODE SIZE
UTM FLNG FEED 0-9116-20 A1
DWG NO. REV.
DG-000-12232-0001 01
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
NOTE:THIS PRINT IS OF A CONFIDENTIAL NATURE AND IS THE PROPERTY OF JGC CORPORATION,TOKYO,JAPAN AND SHALL NOT BE TRACED,PHOTOGRAPHD,PHOTOSTATED OR REPRODUCED IN ANY MANNER,NOR USED FOR ANY PURPOSE WHATSOEVER EXCEPT BY WRITTEN PERMISSION OF JGC CORPORATION.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
NOTES:

COLUMNS DRUMS AND SEPARATORS ABBREVIATIONS


A A
ASV ANTI-SURGE VALVE
ATM ATMOSPHERE
BOG BOIL OFF GAS
CDD CLOSED DRAIN DRY HYDROCARBON
CDW CLOSED DRAIN WET HYDROCARBON
CP HYDROCHLORIC ACID
CWR COOLING WATER RETURN
CWS COOLING WATER SUPPLY
B DF DEFROST GAS B
DH OPEN DRAIN HAZARDOUS
DM DEMINERALISED WATER
DN OPEN DRAIN NON HAZARDOUS
COLUMN WITH PACKING FA FOAM DILUTED
VERTICAL DRUM
FC FAIL CLOSED
FCH DRY FLARE
FCL TANKAGE FLARE
FD DIESEL OIL
FF FOAM
C FGH HP FUEL GAS C
FGL LP FUEL GAS
FL FAIL IN POSITION
FO FAIL OPEN

INTERNALS
MESH
FWH
FW
HC
HHV
WARM FLARE
FIRE WATER
HAND CONTROL
HIGHER HEATING VALUE
No Mark up
Ø1 VANE PACK HS HAND SWITCH
HSS HIGH SIGNAL SELECTOR
D PACKING/ADSORBENT H.C. HYDROCARBON
D
HWR HOT WATER RETURN
LIQUID SPRAY (NOZZLE TYPE) HWS HOT WATER SUPPLY
HALF OPEN PIPE LC LOCKED CLOSE
SWAGED COLUMN LHV LOWER HEATING VALUE
EVEN FLOW DISTRIBUTOR
Ø1 < Ø2 LNG LIQUEFIED NATURAL GAS
OR SWIRL DECK LO LOCKED OPEN
Ø2 < Ø1
MCR CHILLED WATER COOLANT RETURN
CARTRIDGE MCS CHILLED WATER COOLANT SUPPLY
Ø2 MT METHANOL
E DRAW-OFF TRAY MWI MODIFIED WOBBE INDEX
E
N NITROGEN
CHIMNEY
NC NORMALLY CLOSED
REDISTRIBUTION (LIQUID/LIQUID) NL NITROGEN LIQUID
NNF NORMALLY NO FLOW
NO NORMALLY OPEN
VORTEX BREAKER PS PORTSIDE
PW POTABLE WATER
RVP REID VAPOUR PRESSURE
F SDV SHUTDOWN VALVE F
INSTRUMENTATION VALVES AND FITTINGS SR SPLIT RANGE
SWS SEAWATER SUPPLY
SWR SEAWATER RETURN
TSO TIGHT SHUT-OFF
V VENT TO SAFE LOCATION
VA VENT ATMOSPHERIC
CONTROL VALVE VSD VARIABLE SPEED DRIVE
WD FRESH WATER
MIXING INTERNALS
WWT WASTE WATER TREATMENT
G G
ACTUATED VALVE

H CONTINUATIONS HORIZONTAL DRUM OR H


SEPARATOR WITH
- CALMING BAFFLE
- PLATE PACK
FLUID OR SERVICE - BAFFLE
DWG NO. DIRECTION FROM/TO DRAWING
FROM/TO EQUIPMENT NAME/NO.
DWG NO. TITLE
REFERENCE DRAWINGS

FLUID OR SERVICE
I DWG NO. BI-DIRECTIONAL FROM/TO DRAWING HORIZONTAL DRUM OR
SEPARATOR TWO OR
I
FROM/TO EQUIPMENT NAME/NO.
THREE PHASES 01 11-SEP-2023 ISSUED FOR DESIGN T.SUMI M.NAKANE G.SAITO
SAND JETTING / SPARGER NOZZLE
00 01-FEB-2023 ISSUED FOR REVIEW T.SUMI M.NAKANE G.SAITO
REV DATE ISSUE PURPOSE PREP'D CHK'D APR'D
XX CONNECTION TO A PARTICULAR REVISIONS
NETWORK

EQUIPMENT NUMBERING FUNCTION LABELS


XXX
J XXX
STREAM NUMBER BBBBXXXYYYC J
HIGH SELECTING PFD - GENERAL - LEGEND SHEET 2
MULTIPLE EQUIPMENT IDENTIFIER (TOPSIDES AND RELATED UTILITIES)
EQUIPMENT SEQUENCE NUMBER LOW SELECTING
UNIT NUMBER
PRIMARY OR SUPPORTING EQUIPMENT IDENTIFIER PCWBS SHEET SCALE
SUM / ADD NONE 01 of 01 NONE
COMPANY NAME COMPANY ENGINEER

K UTM FLNG Limited Kellogg Brown & Root Limited K


PROJECT NAME JOB CODE SIZE
UTM FLNG FEED 0-9116-20 A1
DWG NO. REV.
DG-000-12232-0002 01
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
NOTE:THIS PRINT IS OF A CONFIDENTIAL NATURE AND IS THE PROPERTY OF JGC CORPORATION,TOKYO,JAPAN AND SHALL NOT BE TRACED,PHOTOGRAPHD,PHOTOSTATED OR REPRODUCED IN ANY MANNER,NOR USED FOR ANY PURPOSE WHATSOEVER EXCEPT BY WRITTEN PERMISSION OF JGC CORPORATION.