K911000M8
Si
& Ancillary PCB
!
EW Model No. K911113M8
N
Extinguishant
Status
Indicators
Model No. S588 Model No. K911100M8
without zonal fire and All models provide high brightness, LED i ndication of
High brightness LEDs
common fault indications Manual O nly, A utomatic and Manual, Hold operated,
there are models to cover Detailed indication of the Disabled, I mminent and Released conditions. M odels are
also available with z onal fire indicators and a common
the requirements for all status of the control panel
fault indicator.
types of system. Monitored data connection
For systems where local control of t he Automatic/Manual
A four core, radial power Countdown timer shows mode and or a M anual extinguishant r elease control are
time remaining until release required, units are available with these controls fitted.
and data connection is all
that is required to connect Manual only and
All models have m onitored inputs for the remote
up to seven status units to Automatic & Manual
connection of Automatic/ Manual mode and Hold switches.
a control panel which mode select keyswitch option All units contain a large, LED d isplay which shows a
means significant savings countdown of the time remaining until the extinguishant is
Four wire connection
in cabling for most (data and power)
released in seconds.
systems. Ancillary PCB
Protected dual action
manual release switch option Product Overview
Ancillary PCB Option for zonal fire and
common fault indication The SIGMA XT Ancillary Board is compatible w ith all
Features with buzzer Sigma XT control panels which have o perating software
version SIGXT_11A.HEX or above.
Robust, high quality enclosure The board provides volt free normally open contacts
Two wire serial connection allowing control of sub-systems and plant remotely from
Easy access to terminals the main panel over a two wire data bus.
Up to 7 per system
Remote Auto/Manual door Mains powered, boxed Ancillary boards require only a two
230V AC or 24V DC interlock input (monitored) core data cable from the main control p anel. 24V D C
powered versions versions require an additional two cores for power either
Remote Hold input from the main panel or from another 24V DC source.
Volt free relay outputs for fire (monitored)
and extinguishing system status Up to 7 A ncillary boards can b e connected to a control
panel and each is allocated an address from 1 to 7 using
Internal fault diagnosis
Relay operated LED indicators a binary coded DIL s witch. The t otal l ength of t he data
indicators
cable from the main panel to the last repeater must not
exceed 1200 metres.
Weatherproof IP65
versions available A mixture of s tatus units and A ncillary boards, up to a
maximum of 7 o f each t ype, can b e connected t o the
Internal buzzer serial data bus.
Page 52
Technical
Ancillary PCB
Sigma Si
256mm Power supply - 21 to 30 V DC
Maximum current draw - 0.07A
Maximum number of status units - 7
Quiescent current - 0.033A
Cable capacity - 2.5mm² per terminal
Monitored inputs end of line resistor - 6K8 0.5W Resistor
170mm
Indications
Manual Only
Auto/Manual
Equipment
Extinguishant
Hold Activated
Disabled
Product Description
Imminent Code
Released K911000M8 6 lamp status unit surface
Fire Zone 1 K911000F8 6 lamp status unit flush
K911100M8 6 lamp status unit with mode select keyswitch surface
Fire Zone 2 available
on 10 lamp K911100F8 6 lamp status unit with mode select keyswitch flush
Fire Zone 3 units only
K911110M8 6 lamp status unit with mode select keyswitch and manual release surface
Fault K911110F8 6 lamp status unit with mode select keyswitch and manual release flush
K911113M8 10 lamp status unit with mode select keyswitch and manual release surface
K911113F8 10 lamp status unit with mode select keyswitch and manual release flush
The manufacturer reserves the right to amend specifications without prior notice Page 53