DWG NO.

:
REFERENCED APPLICATION #1 SPACE HEATING & COOLING WITH DRY CONTACT REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
A control device that enables wireless communication with internet router. External Pump - O
Wi-Fi Modem Including USB cable 0.6m and extension cable 0.5m PWFMDD200
Expansion Tank For IWT, OSHE-12KT (DHW Circuit) O O
Extension Cable for Cable Length 10m Flexible Connection - O
PWYREW000
Wi-Fi Modem Fan Coil Unit - O
A control switch that enables turning THERMA V On/Off after receiving the signal from PDRYCB000 Flow Sensor - O
Dry Contact
external control system. PDRYCB320 Heat Meter - O
OSHW-200F (Single Coil, 200L)
OSHW-300F (Single Coil, 300L)
Domestic Hot Water Tank OSHW-500F (Single Coil, 500L) O O
OSHW-300FD (Double Coil, 300L)
Isolation Valve - O
3rd party accessories PACEZA000 (AC Ez Touch)
LG Central Controller PACS5A000 (AC Smart 5) O
Full Name Description
PACP5A000 (ACP 5)
An external water pump that circulates the water inside piping when water circuit is segregated or pump Magnetic Contactor - O O
External Pump discharge head is insufficient to overcome total system friction loss. Magnetic Filter - O
Controlled by THERMA V with 230V power.
Meter Interface PENKTH000 O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install Mixing Pump
Magnetic Filter - O
the magnetic filter to protect heat pump system.
Mixing Zone Temperature Sensor PRSTAT5K10 O
A water tank containing certain amount of water that secures the required minimum water volume for the system Mixing Valve - O
Buffer Tank or stores heat energy which is needed for defrosting and reducing start up load. PI485 Gateway PMNFP14A1 O
A motorized isolation valve that blocks the water flow into underfloor coil in order to prevent water condensation Pressure Gauge - O
2 Way Valve during cooling mode. Plate Heat Exchanger - O
Controlled by THERMA V with 230V power. Required operating time : less than 90s. Radiator - O
A control device that uses the analogue or digital signals from various devices and then process and control the Recirculation Pump - O
Direct Digital Controller system based on the program written inside the controllers and has the capability to sends the information to Remote Room Air Temperature Sensor PQRSTA0 O
another controller.
Default, PREMTW101 for
Standard III Remote Controller O
2 Remo control
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers.
Solar Pump - O
A control device that senses the temperature of a room and performs actions so that the room's temperature is Safety Relief Valve - O
Thermostat maintained near a desired setpoint. Strainer - O
Thermostat must be connected with Therma V, Valve, Pump, and FCU where applicable. Solar Temperature Sensor (PT-1000) - O
2 Way Valve for Service Valve - O
A isolation valve paired with thermostat to allow whether water flows into the water circuit. Thermostat - O
Thermostat
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #1 SPACE HEATING & COOLING WITH DRY CONTACT
LG ACCESSORIES

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & Cooling with Dry Contact
Product R32 Monobloc S (New) Wi-Fi Modem (PWFMDD200)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
UFH(H) + FCU(H&C) A control device that enables wireless
Terminal Device
communication with internet router.
Main Controller 3rd Party Controller Expansion Tank Including USB cable 0.6m and extension cable
Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor
Control Setting of LG RS3 Controller Based on Water Temp. 0.5m
External Pump Controlled by 3rd Party Controller Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG Extension Cable for Wi-Fi Modem
(PWYREW000)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem Cable Length 10m
LG

Dry Contact (PDRYCB000, PDRYCB320)


Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
A control switch that enables turning THERMA V
On/Off after receiving the signal from external
Drain Pressure Reducing Valve Drain Pan Cover Plate control system.

SPACE HEATING AREA

COOLING CIRCUIT

THERMOSTAT 1 THERMOSTAT 2
RS3
3RD PARTY ACCESSORIES

FCU UFH External Pump


An external water pump that circulates the water
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
total system friction loss.
3RD PARTY
DDC / PLC
CONTROL SYSTEM
POWER SUPPLY DRY CONTACT Magnetic Filter (Recommended)
Dry Contact
A magnetic filter that collects metallic particle
caused by corrosion or erosion. It is strongly
2 WAY VALVE FOR 2 WAY VALVE FOR recommended to install the magnetic filter to
LG THERMOSTAT THERMOSTAT
(OPTION)
protect heat pump system.

Buffer Tank
A water tank containing certain amount of water
that secures the required minimum water volume
1Ø 220-240V AC or 3Ø 380-415V AC

for the system or stores heat energy which is


BUILT IN COMPONENTS
needed for defrosting and reducing start up load.
- Plate Type Heat Ex.
- Water pump
- Expansion vessel (8 L) POWER
2 Way Valve
CN_REMO

- Safety valve (3 bar) SUPPLY A motorized isolation valve that blocks the water
- Pressure sensor WI-FI flow into underfloor coil in order to prevent water
- Strainer (30 mesh) MODEM condensation during cooling mode.
- Flow sensor
Controlled by THERMA V with 230V power.
LG MAGNETIC Required operating time : less than 90s.
CONTACTOR 2 WAY
VALVE DDC (Direct Digital Controller)
LG CN_CC
A control device that uses the analogue or digital
TB1 4 / 6 signals from various devices and then process and
THERMA V
control the system based on the program written
CN_WF DIFFERENTIAL inside the controllers and has the capability to
EXTERNAL PUMP PRESSURE
VALVE sends the information to another controller.
DN25
DN25 Thermostat
MAKE UP WATER A control device that senses the temperature of a
room and performs actions so that the room's
SERVICE temperature is maintained near a desired setpoint.
THERMA V R32 MONOBLOC S VALVE Thermostat must be connected with Therma V,
Valve, Pump, and FCU where applicable.
MAGNETIC FILTER
(RECOMMENDED) BUFFER TANK
2 Way Valve for Thermostat
A isolation valve paired with thermostat to allow
whether water flows into the water circuit.

Differential Pressure Valve


A self pressure regulating valve that provides
constant differential pressure between supply and
return headers.

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #1 SPACE HEATING & COOLING WITH DRY CONTACT
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
ON
OFF
1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

3RD PARTY
DDC SW2
DRY CONTACT CONTROL SYSTEM

L
ON
MIX PUMP

THERMOSTAT 1

CN_CC
BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

Dry Contact

N OFF
1 2 3 4 5 6 7 8
LG THERMOSTAT 2
L

X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
Communication
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

2 WAY Antifreeze is not applied X


VALVE Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
Air Sensor installed
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

2 WAY VALVE Full capacity is used O O


2 WAY

- L : on Voltage when Cooling is active (NO Valve) EXTERNAL Thermostat Thermostat is not installed X
L1
5

PUMP Installation Thermostat is installed O


- L1 : on Voltage when Cooling is not active (NC Valve)
CN_ROOM1
default setting X X X X X X X X
4
L

230 V AC
BR BR BL

N
3
MIXING
VALVE

L1
2

MAIN PCB (CYCLE)


TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

TB_EXT

X : OFF / O : ON
L3

DIP SW 1 2 3
Always mode : Maintain low noise
MAGNETIC mode for target temperature X
CONTACTOR Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

Max mode X
21 22 23 24
BL BR WH BK

L2

Peak Control Peak control : To limit maximum


O
current (Power saving)
TB2 & TB3

default setting X X
L1

POWER
CN_MIX_OUT
N

SUPPLY
1Ø 220 ~ 240 V AC
L

NOTE
RS3
WIFI MODEM
1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.

Power supply of
Main T/B R
CN_WF

POWER S T N the 3 Phase Model


SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #2-1 SPACE HEATING & COOLING WITH THERMOSTAT REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
Expansion Tank For IWT, OSHE-12KT (DHW Circuit) O O
Flexible Connection - O
Fan Coil Unit - O
Flow Sensor - O
Heat Meter - O
3rd party accessories OSHW-200F (Single Coil, 200L)
OSHW-300F (Single Coil, 300L)
Full Name Description Domestic Hot Water Tank O O
OSHW-500F (Single Coil, 500L)
OSHW-300FD (Double Coil, 300L)
An external water pump that circulates the water inside piping when water circuit is segregated or pump
External Pump Isolation Valve - O
discharge head is insufficient to overcome total system friction loss.
PACEZA000 (AC Ez Touch)
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install LG Central Controller PACS5A000 (AC Smart 5) O
Magnetic Filter
the magnetic filter to protect heat pump system. PACP5A000 (ACP 5)
Magnetic Contactor - O O
A water tank containing certain amount of water that secures the required minimum water volume for the system
Buffer Tank Magnetic Filter - O
or stores heat energy which is needed for defrosting and reducing start up load.
Meter Interface PENKTH000 O
A motorized isolation valve that blocks the water flow into underfloor coil in order to prevent water condensation Mixing Pump - O
2 Way Valve during cooling mode.
Mixing Zone Temperature Sensor PRSTAT5K10 O
Controlled by THERMA V with 230V power. Required operating time : less than 90s.
Mixing Valve - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers. PI485 Gateway PMNFP14A1 O
Pressure Gauge - O
A control device that senses the temperature of a room and performs actions so that the room's temperature is Plate Heat Exchanger - O
Thermostat maintained near a desired setpoint. Radiator - O
Thermostat must be connected with Therma V, Valve, Pump, and FCU where applicable.
Recirculation Pump - O
2 Way Valve for Remote Room Air Temperature Sensor PQRSTA0 O
A isolation valve paired with thermostat to allow whether water flows into the water circuit.
Thermostat Default, PREMTW101 for
Standard III Remote Controller O
2 Remo control
Solar Pump - O
Safety Relief Valve - O
Strainer - O
Solar Temperature Sensor (PT-1000) - O
Service Valve - O
Thermostat - O
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #2-1 SPACE HEATING & COOLING WITH THERMOSTAT
LG ACCESSORIES

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & Cooling with Thermostat
Product R32 Monobloc S (New)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Terminal Device UFH(H) + FCU(H&C)
Main Controller Thermostat Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor
Control Setting of LG RS3 Controller Based on Water Temp.
External Pump Controlled by Thermostat Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG

Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem


LG

Flexible Connection Shut Off Valve Magnetic Contactor Thermostat

Drain Pressure Reducing Valve Drain Pan Cover Plate

SPACE HEATING AREA

COOLING CIRCUIT

RS3 THERMOSTAT 1 THERMOSTAT 2 3RD PARTY ACCESSORIES

FCU UFH External Pump


An external water pump that circulates the water
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
total system friction loss.

POWER SUPPLY Magnetic Filter (Recommended)


A magnetic filter that collects metallic particle
caused by corrosion or erosion. It is strongly
2 WAY VALVE FOR 2 WAY VALVE FOR
recommended to install the magnetic filter to
THERMOSTAT THERMOSTAT
(OPTION) protect heat pump system.

Buffer Tank
A water tank containing certain amount of water
that secures the required minimum water volume
1Ø 220-240V AC or 3Ø 380-415V AC

for the system or stores heat energy which is


BUILT IN COMPONENTS
needed for defrosting and reducing start up load.
- Plate Type Heat Ex.
- Water pump POWER SUPPLY
- Expansion vessel (8 L) 2 Way Valve
CN_REMO

- Safety valve (3 bar) A motorized isolation valve that blocks the water
- Pressure sensor flow into underfloor coil in order to prevent water
- Strainer (30 mesh) condensation during cooling mode.
- Flow sensor MAGNETIC Controlled by THERMA V with 230V power.
CONTACTOR
Required operating time : less than 90s.
2 WAY
VALVE Thermostat
LG
TB1 4 / 6 A control device that senses the temperature of a
room and performs actions so that the room's
TB2 21 / 22 / 23 / 24
THERMA V
TB3 25 temperature is maintained near a desired setpoint.
DIFFERENTIAL Thermostat must be connected with each 2 Way
EXTERNAL PUMP PRESSURE
VALVE Valve and FCU where applicable.
DN25
DN25 2 Way Valve for Thermostat
MAKE UP WATER A isolation valve paired with thermostat to allow
whether water flows into the water circuit.
SERVICE
THERMA V R32 MONOBLOC S VALVE Differential Pressure Valve
A self pressure regulating valve that provides
MAGNETIC FILTER constant differential pressure between supply and
(RECOMMENDED) BUFFER TANK
return headers.

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #2-1 SPACE HEATING & COOLING WITH THERMOSTAT
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
ON
OFF
1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

SW2

L
ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
1 2 3 4 5 6 7 8
L

X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
Communication
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

2 WAY Antifreeze is not applied X


VALVE Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
Air Sensor installed
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


2 WAY VALVE
2 WAY

Thermostat Thermostat is not installed X


L1
5

- L : on Voltage when Cooling is active (NO Valve) Installation Thermostat is installed O


CN_ROOM1

- L1 : on Voltage when Cooling is not active (NC Valve) default setting X X X X X X X X


4
L

230 V AC
BR BR BL

N
3
MIXING
VALVE

L1

EXTERNAL
2

PUMP
MAIN PCB (CYCLE)
TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

230 V AC / L3 DHW
TB_EXT

X : OFF / O : ON
L3

DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

230 V AC / L2 Heating Mode DHW Max mode X


21 22 23 24
BL BR WH BK

L2

C H (On/Off)
(C/H) Peak Control Peak control : To limit maximum
O
current (Power saving)
230 V AC / L1 Cooling
TB2 & TB3

default setting X X
L1

CN_MIX_OUT
N

230 V AC MECHANICAL
L

THERMOSTAT
(3rd party)
NOTE
RS3 MAGNETIC
CONTACTOR 1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT
(ELCB) should be installed for power supply line.
POWER
SUPPLY
Power supply of
Main T/B R
CN_WF

POWER S T N 1Ø 220 ~ 240 V AC


the 3 Phase Model
SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #2-2 SPACE HEATING & COOLING WITH THERMOSTAT REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
Expansion Tank For IWT, OSHE-12KT (DHW Circuit) O O
Flexible Connection - O
Fan Coil Unit - O
Flow Sensor - O
Heat Meter - O
3rd party accessories OSHW-200F (Single Coil, 200L)
OSHW-300F (Single Coil, 300L)
Full Name Description Domestic Hot Water Tank OSHW-500F (Single Coil, 500L) O O
OSHW-300FD (Double Coil, 300L)
An external water pump that circulates the water inside piping when water circuit is segregated or pump
External Pump Isolation Valve - O
discharge head is insufficient to overcome total system friction loss.
PACEZA000 (AC Ez Touch)
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install LG Central Controller PACS5A000 (AC Smart 5) O
Magnetic Filter
the magnetic filter to protect heat pump system. PACP5A000 (ACP 5)
Magnetic Contactor - O O
A water tank containing certain amount of water that secures the required minimum water volume for the system Magnetic Filter
Buffer Tank - O
or stores heat energy which is needed for defrosting and reducing start up load.
Meter Interface PENKTH000 O
A motorized isolation valve that blocks the water flow into underfloor coil in order to prevent water condensation Mixing Pump - O
2 Way Valve during cooling mode. Mixing Zone Temperature Sensor PRSTAT5K10 O
Controlled by THERMA V with 230V power. Required operating time : less than 90s.
Mixing Valve - O
A control device that senses the temperature of a room and performs actions so that the room's temperature is
Thermostat maintained near a desired setpoint. PI485 Gateway PMNFP14A1 O
Thermostat must be connected with Therma V, Valve, Pump, and FCU where applicable. Pressure Gauge - O
Plate Heat Exchanger - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers. Radiator - O
Recirculation Pump - O
Remote Room Air Temperature Sensor PQRSTA0 O
Default, PREMTW101 for
Standard III Remote Controller O
2 Remo control
Solar Pump - O
Safety Relief Valve - O
Strainer - O
Solar Temperature Sensor (PT-1000) - O
Service Valve - O
Thermostat - O
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #2-2 SPACE HEATING & COOLING WITH THERMOSTAT
LG ACCESSORIES

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & Cooling with Thermostat
Product R32 Monobloc S (New)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Terminal Device UFH(H) + FCU(H&C)
Main Controller Thermostat Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor
Control Setting of LG RS3 Controller Based on Water Temp.
External Pump Controlled by Thermostat Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG

Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem


LG

Flexible Connection Shut Off Valve Magnetic Contactor Thermostat

Drain Pressure Reducing Valve Drain Pan Cover Plate

SPACE HEATING AREA

THERMOSTAT
RS3
3RD PARTY ACCESSORIES

FCU (C) UFH (H) External Pump


An external water pump that circulates the water
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
total system friction loss.

POWER SUPPLY Magnetic Filter (Recommended)


A magnetic filter that collects metallic particle
caused by corrosion or erosion. It is strongly
recommended to install the magnetic filter to
protect heat pump system.

Buffer Tank
A water tank containing certain amount of water
that secures the required minimum water volume
1Ø 220-240V AC or 3Ø 380-415V AC

for the system or stores heat energy which is


BUILT IN COMPONENTS
needed for defrosting and reducing start up load.
- Plate Type Heat Ex.
- Water pump POWER SUPPLY
- Expansion vessel (8 L) 2 Way Valve
CN_REMO

- Safety valve (3 bar) A motorized isolation valve that blocks the water
- Pressure sensor flow into underfloor coil in order to prevent water
- Strainer (30 mesh) condensation during cooling mode.
- Flow sensor MAGNETIC Controlled by THERMA V with 230V power.
CONTACTOR
Required operating time : less than 90s.
2 WAY VALVE 2 WAY VALVE
FOR COOLING FOR HEATING Thermostat
LG
TB1 4 / 5 / 6 A control device that senses the temperature of a
room and performs actions so that the room's
TB2 21 / 22 / 23 / 24
THERMA V
TB3 25 temperature is maintained near a desired setpoint.
DIFFERENTIAL In this application, Thermostat must be connected
EXTERNAL PUMP PRESSURE
VALVE with Therma V and interlocking operation with FCU
DN25
is required.
DN25
MAKE UP WATER Differential Pressure Valve
A self pressure regulating valve that provides
SERVICE constant differential pressure between supply and
THERMA V R32 MONOBLOC S VALVE return headers.

MAGNETIC FILTER
(RECOMMENDED) BUFFER TANK

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #2-2 SPACE HEATING & COOLING WITH THERMOSTAT
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
ON
OFF
1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

SW2

L
ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
1 2 3 4 5 6 7 8
L

2 WAY VALVE X : OFF / O : ON


PUMP (B)

FOR HEATING
N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
(NC Valve) MODBUS
2 WAY VALVE Communication
Master (Link to LG controller) X
L

- L : on Voltage when Cooling is active Type Slave (Link to 3rd party controller) O

- L1 : on Voltage when Cooling is not active MODBUS REGINE X


Function Unified Open Protocol O
W.TANK
HEATER

2 WAY VALVE
Antifreeze is not applied X
FOR COOLING Antifreeze Mode Antifreeze is applied (Adjustable
(NC Valve) anti-freeze temp.)
O
L

default setting X X X
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
Air Sensor installed
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


230 V AC
2 WAY

Thermostat Thermostat is not installed X


L1
5

Installation Thermostat is installed O


CN_ROOM1
default setting X X X X X X X X
230 V AC
4
L
BR BR BL

N
3
MIXING
VALVE

L1

EXTERNAL
2

PUMP
MAIN PCB (CYCLE)
TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

230 V AC / L3 DHW
TB_EXT

X : OFF / O : ON
L3

DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

230 V AC / L2 Heating Mode DHW Max mode X


21 22 23 24
BL BR WH BK

L2

C H (On/Off)
(C/H) Peak Control Peak control : To limit maximum
O
current (Power saving)
230 V AC / L1 Cooling
TB2 & TB3

default setting X X
L1

CN_MIX_OUT
N

230 V AC MECHANICAL
L

THERMOSTAT
(3rd party)
NOTE
RS3 MAGNETIC
CONTACTOR 1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT
(ELCB) should be installed for power supply line.
POWER
SUPPLY
Power supply of
Main T/B R
CN_WF

POWER S T N 1Ø 220 ~ 240 V AC


the 3 Phase Model
SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #2-3 SPACE HEATING & COOLING WITH THERMOSTAT REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
Expansion Tank For IWT, OSHE-12KT (DHW Circuit) O O
Flexible Connection - O
Fan Coil Unit - O
Flow Sensor - O
3rd party accessories Heat Meter - O
OSHW-200F (Single Coil, 200L)
Full Name Description OSHW-300F (Single Coil, 300L)
Domestic Hot Water Tank OSHW-500F (Single Coil, 500L) O O
An external water pump that circulates the water inside piping when water circuit is segregated or pump OSHW-300FD (Double Coil, 300L)
External Pump
discharge head is insufficient to overcome total system friction loss. Isolation Valve - O
PACEZA000 (AC Ez Touch)
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to LG Central Controller PACS5A000 (AC Smart 5) O
Magnetic Filter
install the magnetic filter to protect heat pump system. PACP5A000 (ACP 5)
A water tank containing certain amount of water that secures the required minimum water volume for the system Magnetic Contactor - O O
Buffer Tank or stores heat energy which is needed for defrosting and reducing start up load. Magnetic Filter - O
Meter Interface PENKTH000 O
A motorized 3-way diverting valve determining flow direction to underfloor coil or FCU. Mixing Pump - O
3 Way Valve
Controlled by THERMA V with 230V power. Operating time 3s. Mixing Zone Temperature Sensor PRSTAT5K10 O
A control device that senses the temperature of a room and performs actions so that the room's temperature is Mixing Valve - O
Thermostat maintained near a desired setpoint. PI485 Gateway PMNFP14A1 O
Thermostat must be connected with Therma V, Valve, Pump, and FCU where applicable. Pressure Gauge - O
Plate Heat Exchanger - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers.
Radiator - O
Recirculation Pump - O
Remote Room Air Temperature Sensor PQRSTA0 O
Default, PREMTW101 for
Standard III Remote Controller O
2 Remo control
Solar Pump - O
Safety Relief Valve - O
Strainer - O
Solar Temperature Sensor (PT-1000) - O
Service Valve - O
Thermostat - O
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #2-3 SPACE HEATING & COOLING WITH THERMOSTAT
LG ACCESSORIES

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & Cooling with Thermostat
Product R32 Monobloc S (New)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Terminal Device UFH(H) + FCU(H&C)
Main Controller Thermostat Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor
Control Setting of LG RS3 Controller Based on Water Temp.
External Pump Controlled by Thermostat Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG

Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem


LG

Flexible Connection Shut Off Valve Magnetic Contactor Thermostat

Drain Pressure Reducing Valve Drain Pan Cover Plate

SPACE HEATING AREA

THERMOSTAT
RS3
3RD PARTY ACCESSORIES

FCU (C) UFH (H) External Pump


An external water pump that circulates the water
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
total system friction loss.

POWER SUPPLY Magnetic Filter (Recommended)


A magnetic filter that collects metallic particle
caused by corrosion or erosion. It is strongly
recommended to install the magnetic filter to
protect heat pump system.

Buffer Tank
A water tank containing certain amount of water
that secures the required minimum water volume
1Ø 220-240V AC or 3Ø 380-415V AC

for the system or stores heat energy which is


BUILT IN COMPONENTS
needed for defrosting and reducing start up load.
- Plate Type Heat Ex.
- Water pump POWER SUPPLY
- Expansion vessel (8 L) 3 Way Valve
CN_REMO

- Safety valve (3 bar) A motorized 3-way diverting valve determining flow


- Pressure sensor direction to underfloor coil or FCU.
- Strainer (30 mesh) Controlled by THERMA V with 230V power.
- Flow sensor MAGNETIC Operating time 3s.
CONTACTOR

Thermostat
LG
A control device that senses the temperature of a
TB1 4 / 5 / 6 room and performs actions so that the room's
temperature is maintained near a desired setpoint.
THERMA V
TB2 21 / 22 / 23 / 24
TB3 25 In this application, Thermostat must be connected
3 WAY VALVE
(SWITCHING
with Therma V and interlocking operation with FCU
EXTERNAL PUMP
HEATING/COOLING) is required.
DN25
DN25 Differential Pressure Valve
MAKE UP WATER A self pressure regulating valve that provides
constant differential pressure between supply and
SERVICE return headers.
THERMA V R32 MONOBLOC S VALVE

MAGNETIC FILTER
(RECOMMENDED) BUFFER TANK

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #2-3 SPACE HEATING & COOLING WITH THERMOSTAT
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
ON
OFF
1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

SW2

L
ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
1 2 3 4 5 6 7 8
L

X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
3 WAY VALVE MODBUS Master (Link to LG controller) X
(SWITCHING Communication
L

Type Slave (Link to 3rd party controller) O


HEATING/COOLING)
3 WAY VALVES FOR SWITCHING HEATING / COOLING MODBUS REGINE X
Function
- L : on Voltage when Cooling is active Unified Open Protocol O
W.TANK
HEATER

Antifreeze is not applied X


- L1 : on Voltage when Heating is active Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
Air Sensor installed
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


230 V AC
2 WAY

Thermostat Thermostat is not installed X


L1
5

Installation Thermostat is installed O


CN_ROOM1
default setting X X X X X X X X
230 V AC
4
L
BR BR BL

N
3
MIXING
VALVE

L1

EXTERNAL
2

PUMP
MAIN PCB (CYCLE)
TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

230 V AC / L3 DHW
TB_EXT

X : OFF / O : ON
L3

DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

230 V AC / L2 Heating Mode DHW Max mode X


21 22 23 24
BL BR WH BK

L2

C H (On/Off)
(C/H) Peak Control Peak control : To limit maximum
O
current (Power saving)
230 V AC / L1 Cooling
TB2 & TB3

default setting X X
L1

CN_MIX_OUT
N

230 V AC MECHANICAL
L

THERMOSTAT
(3rd party)
NOTE
RS3 MAGNETIC
CONTACTOR 1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT
(ELCB) should be installed for power supply line.
POWER
SUPPLY
Power supply of
Main T/B R
CN_WF

POWER S T N 1Ø 220 ~ 240 V AC


the 3 Phase Model
SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #3 SPACE HEATING WITH ANTI-FREEZE REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
A control device that enables wireless communication with internet router. Expansion Tank For IWT, OSHE-12KT (DHW Circuit)
Wi-Fi Modem PWFMDD200 O O
Including USB cable 0.6m and extension cable 0.5m
Flexible Connection - O
Fan Coil Unit - O
Extension Cable for Cable Length 10m Flow Sensor - O
PWYREW000
Wi-Fi Modem
Heat Meter - O
OSHW-200F (Single Coil, 200L)
OSHW-300F (Single Coil, 300L)
Domestic Hot Water Tank OSHW-500F (Single Coil, 500L) O O
3rd party accessories OSHW-300FD (Double Coil, 300L)
Isolation Valve - O
Full Name Description PACEZA000 (AC Ez Touch)
LG Central Controller PACS5A000 (AC Smart 5) O
An external water pump that circulates the water inside piping when water circuit is segregated or pump PACP5A000 (ACP 5)
External Pump
discharge head is insufficient to overcome total system friction loss.
Magnetic Contactor - O O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install Magnetic Filter - O
Magnetic Filter
the magnetic filter to protect heat pump system. Meter Interface PENKTH000 O
Mixing Pump - O
A water tank containing certain amount of water that secures the required minimum water volume for the system
Buffer Tank Mixing Zone Temperature Sensor PRSTAT5K10 O
or stores heat energy which is needed for defrosting and reducing start up load.
Mixing Valve - O
PI485 Gateway PMNFP14A1 O
Plate Heat Exchanger A heat exchanger made by stacking several thin metal plates that transfers heat between two fluids.
Pressure Gauge - O
Plate Heat Exchanger - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers. Radiator - O
Recirculation Pump - O
Remote Room Air Temperature Sensor PQRSTA0 O
Default, PREMTW101 for
Standard III Remote Controller O
2 Remo control
Solar Pump - O
Safety Relief Valve - O
Strainer - O
Solar Temperature Sensor (PT-1000) - O
Service Valve - O
Thermostat - O
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #3 SPACE HEATING WITH ANTI-FREEZE
LG ACCESSORIES

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating with Anti-freeze
Product R32 Monobloc S (New) Wi-Fi Modem (PWFMDD200)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
A control device that enables wireless
Terminal Device RAD
communication with internet router.
Main Controller LG RS3 Controller Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Including USB cable 0.6m and extension cable
Control Setting of LG RS3 Controller Based on Air Temp. 0.5m
External Pump Controlled by THERMA V Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
Antifreeze is applied on primary circuit only LG Extension Cable for Wi-Fi Modem
Remark (PWYREW000)
(Therma V to PHE)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem Cable Length 10m
LG

Flexible Connection Shut Off Valve Magnetic Contactor Thermostat

Drain Pressure Reducing Valve Drain Pan Cover Plate

SPACE HEATING AREA


RS3
3RD PARTY ACCESSORIES

RAD RAD External Pump


An external water pump that circulates the water
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
total system friction loss.

POWER SUPPLY Magnetic Filter (Recommended)


A magnetic filter that collects metallic particle
caused by corrosion or erosion. It is strongly
recommended to install the magnetic filter to
protect heat pump system.

Buffer Tank
A water tank containing certain amount of water
that secures the required minimum water volume
1Ø 220-240V AC or 3Ø 380-415V AC

POWER SUPPLY for the system or stores heat energy which is


BUILT IN COMPONENTS
needed for defrosting and reducing start up load.
- Plate Type Heat Ex.
- Water pump
- Expansion vessel (8 L) Plate Heat Exchanger
CN_REMO

- Safety valve (3 bar)


MAGNETIC
A heat exchanger made by stacking several thin
- Pressure sensor WI-FI metal plates that transfers heat between two fluids.
CONTACTOR
- Strainer (30 mesh) MODEM
- Flow sensor
Differential Pressure Valve
LG
A self pressure regulating valve that provides
PLATE HEAT constant differential pressure between supply and
LG
EXCHANGER return headers.

CN_WF

THERMA V TB_EXT_PUMP A2
DIFFERENTIAL
EXTERNAL PUMP_A EXTERNAL PUMP_B PRESSURE
DN25 VALVE

DN25
MAKE UP WATER

SERVICE
THERMA V R32 MONOBLOC S VALVE

MAGNETIC FILTER MAKE UP WATER


(RECOMMENDED) BUFFER TANK

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #3 SPACE HEATING WITH ANTI-FREEZE
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
ON
OFF
1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

SW2

L
ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
1 2 3 4 5 6 7 8
L

CN_ANTI_SW
X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
Communication
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

SHORT PIN
Antifreeze is not applied X
SHOULD BE Antifreeze Mode Antifreeze is applied (Adjustable
DISCONNECT anti-freeze temp.)
O
L

default setting X X X
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR RS3 Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
Air Sensor installed
EXTERNAL EXTERNAL (Accessory)
7

Remote room air sensor is installed O


L

PUMP_A PUMP_B
Backup heater is not used X X
Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


2 WAY

Thermostat Thermostat is not installed X


L1
5

Installation Thermostat is installed O


CN_ROOM1
default setting X X X X X X X X
4
L
BR BR BL

N
3
MIXING
VALVE

L1
2

MAIN PCB (CYCLE)


TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

L N there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

MAGNETIC
TB_EXT

X : OFF / O : ON
L3

CONTACTOR DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

Max mode X
21 22 23 24
BL BR WH BK

L2

Peak Control Peak control : To limit maximum


O
current (Power saving)
TB2 & TB3

default setting X
POWER X
L1

SUPPLY
1Ø 220 ~ 240 V AC
CN_MIX_OUT
N
L

NOTE
WIFI MODEM

1. The wiring cable size and Circuit breaker selection


CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.

Power supply of
Main T/B R
CN_WF

POWER S T N the 3 Phase Model


SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #4 SPACE HEATING WITH 2ND CIRCUIT REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
A control device that enables wireless communication with internet router. Expansion Tank For IWT, OSHE-12KT (DHW Circuit)
Wi-Fi Modem PWFMDD200 O O
Including USB cable 0.6m and extension cable 0.5m
Flexible Connection - O
Fan Coil Unit - O
Extension Cable for Cable Length 10m Flow Sensor - O
PWYREW000
Wi-Fi Modem
Heat Meter - O
OSHW-200F (Single Coil, 200L)
Remote Room Air OSHW-300F (Single Coil, 300L)
Temperature sensor for the room. Cable length 15m. PQRSTA0 Domestic Hot Water Tank O O
Temperature Sensor OSHW-500F (Single Coil, 500L)
OSHW-300FD (Double Coil, 300L)
Mixing Zone Isolation Valve - O
A temperature sensor for the mixed circuit. Cable length 10m. PRSTAT5K10 PACEZA000 (AC Ez Touch)
Temperature Sensor
LG Central Controller PACS5A000 (AC Smart 5) O
PACP5A000 (ACP 5)
Magnetic Contactor - O O
Magnetic Filter - O
Meter Interface PENKTH000 O
3rd party accessories Mixing Pump - O
Mixing Zone Temperature Sensor PRSTAT5K10 O
Full Name Description
Mixing Valve - O
An external water pump that circulates the water inside piping when water circuit is segregated or pump PI485 Gateway PMNFP14A1 O
External Pump
discharge head is insufficient to overcome total system friction loss. Pressure Gauge - O
Plate Heat Exchanger - O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install
Magnetic Filter Radiator - O
the magnetic filter to protect heat pump system.
Recirculation Pump - O
A water tank containing certain amount of water that secures the required minimum water volume for the system Remote Room Air Temperature Sensor PQRSTA0 O
Buffer Tank or stores heat energy which is needed for defrosting and reducing start up load. Default, PREMTW101 for
Standard III Remote Controller O
An external water pump that circulates the water inside mixted circuit (zone 1). 2 Remo control
Mixing Pump Solar Pump - O
Controlled by THERMA V with 230V power.
Safety Relief Valve - O
A motorized 3-way mixing valve throttling mixing ratio of heated water and return water.
Mixing Valve Strainer - O
Controlled by THERMA V with 230V power supply. Operating times: 60-900 sec.
Solar Temperature Sensor (PT-1000) - O
Service Valve - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers.
Thermostat - O
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #4 SPACE HEATING WITH 2ND CIRCUIT
LG ACCESSORIES

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating with 2nd Circuit
Product R32 Monobloc S (New) Wi-Fi Modem (PWFMDD200)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
A control device that enables wireless
Terminal Device UFH + RAD
communication with internet router.
Main Controller LG RS3 Controller Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Including USB cable 0.6m and extension cable
Control Setting of LG RS3 Controller Based on Air Temp. or Water Temp. 0.5m
External Pump Controlled by THERMA V Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG Extension Cable for Wi-Fi Modem
(PWYREW000)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem Cable Length 10m
LG

Remote Room Air Temperature Sensor


Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
(PQRSTA0)
Temperature sensor for the room. Cable length
Drain Pressure Reducing Valve Drain Pan Cover Plate 15m.

Mixing Zone Temperature Sensor


(PRSTAT5K10)
A temperature sensor for the mixed circuit. Cable
length 10m.

REMOTE ROOM
AIR SENSOR

RS3
3RD PARTY ACCESSORIES

RAD UFH
External Pump
An external water pump that circulates the water
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
total system friction loss.
POWER SUPPLY
ZONE 2 ZONE 1 Magnetic Filter (Recommended)
A magnetic filter that collects metallic particle
caused by corrosion or erosion. It is strongly
recommended to install the magnetic filter to
MIXING
protect heat pump system.
ZONE
TEMP. Buffer Tank
1Ø 220-240V AC or 3Ø 380-415V AC

SENSOR A water tank containing certain amount of water


that secures the required minimum water volume
BUILT IN COMPONENTS
- Plate Type Heat Ex.
for the system or stores heat energy which is
- Water pump POWER SUPPLY needed for defrosting and reducing start up load.
WI-FI
- Expansion vessel (8 L)
CN_ROOM2

MODEM MIXING
CN_REMO

- Safety valve (3 bar)


PUMP Mixing Pump
- Pressure sensor An external water pump that circulates the water
- Strainer (30 mesh) LG

inside mixted circuit (zone 1).


- Flow sensor MAGNETIC
CONTACTOR Controlled by THERMA V with 230V power.

Mixing Valve
CN_WF
MIXING A motorized 3-way mixing valve throttling mixing
LG CN_MIX_OUT EXTERNAL
VALVE ratio of heated water and return water.
TB1 17 / 18 PUMP
TB1 1 / 2 / 3 Controlled by THERMA V with 230V power supply.
THERMA V
TB_EXT_PUMP A2
Operating times: 60-900 sec.

DN25
Differential Pressure Valve
A self pressure regulating valve that provides
DN25 DIFFERENTIAL constant differential pressure between supply and
PRESSURE
MAKE UP WATER
VALVE
return headers.

SERVICE
THERMA V R32 MONOBLOC S VALVE

MAGNETIC FILTER
(RECOMMENDED) BUFFER TANK

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #4 SPACE HEATING WITH 2ND CIRCUIT
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
ON
OFF
1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

SW2

L
ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
230 V AC 1 2 3 4 5 6 7 8
L

X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
Communication
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

Antifreeze is not applied X


Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X

DIRECT CIRCUIT (ZONE 2) MIXED CIRCUIT (ZONE 1)


N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9

RAD UFH
VALVE (A)

RS3 Heat Pump Cycle


Heating only X
3 WAY

REMOTE ROOM Heating and cooling O


L1
8

TEMP. SENSOR

CN_ROOM2
Remote Room Remote room air sensor is not
X
Air Sensor installed
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


2 WAY

MIXING Thermostat Thermostat is not installed X


L1
5

VALVE Installation Thermostat is installed O


CN_ROOM1
default setting X X X X X X X X
4
L
BR BR BL

N
3
MIXING
VALVE

230 V AC / mixing valve open (mixing)


L1

MIXING
2

PUMP
230 V AC / mixing valve close (no mixing) MAIN PCB (CYCLE)
TB1

1
L

EXTERNAL SW1
PUMP
ON For 5/7/9 kW models,
RD BK WH
Controller

OFF
25 26 27
3rd Party

L N there is no No.6 pin.


B

MIXING ZONE 1 2 3 4 5 6
BOILER PUMP A2

TEMPERATURE
A

SENSOR
TB_EXT

MAGNETIC X : OFF / O : ON
L3

CONTACTOR DIP SW 1 2 3
Always mode : Maintain low noise
X
POWER Low Noise Mode
mode for target temperature

SUPPLY Partial mode : Escape low noise


O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

1Ø 220 ~ 240 V AC Max mode X


21 22 23 24
BL BR WH BK

L2

Peak Control Peak control : To limit maximum


O
current (Power saving)
TB2 & TB3

default setting X X
L1

CN_MIX_OUT
N
L

NOTE

WIFI MODEM
1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.

Power supply of
Main T/B R
CN_WF

POWER S T N the 3 Phase Model


SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #5 SPACE HEATING AND COOLING WITH 2 REMOTE CONTROLLERS REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote
Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller (MASTER)
extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
A control device that enables wireless communication with internet router. Expansion Tank For IWT, OSHE-12KT (DHW Circuit)
Wi-Fi Modem PWFMDD200 O O
Including USB cable 0.6m and extension cable 0.5m
Flexible Connection - O
Fan Coil Unit - O
Extension Cable for Cable Length 10m Flow Sensor - O
PWYREW000
Wi-Fi Modem
Heat Meter - O
An additional wired remote controller with built-in temperature sensor that enables OSHW-200F (Single Coil, 200L)
RS3 wired remote OSHW-300F (Single Coil, 300L)
controlling THERMA V using two remote controller. PREMTW101 Domestic Hot Water Tank O O
controller (SLAVE) OSHW-500F (Single Coil, 500L)
Including extension wire(PZCWRC1) and 2 remo cable(PZCWRC2)
OSHW-300FD (Double Coil, 300L)
Extension Wire for RS3 PZCWRC1, Included in Isolation Valve - O
Cable length 10m PACEZA000 (AC Ez Touch)
Controller PREMTW101.
LG Central Controller PACS5A000 (AC Smart 5) O
PACP5A000 (ACP 5)
A cable that enables connecting two remote controller on the one indoor unit. PZCWRC2, Included in Magnetic Contactor - O O
2 Remo Cable
PREMTW101.
Magnetic Filter - O
Meter Interface PENKTH000 O
Mixing Pump - O
Mixing Zone Temperature Sensor PRSTAT5K10 O
Mixing Valve - O
3rd party accessories PI485 Gateway PMNFP14A1 O
Pressure Gauge - O
Full Name Description
Plate Heat Exchanger - O
An external water pump that circulates the water inside piping when water circuit is segregated or pump Radiator - O
External Pump
discharge head is insufficient to overcome total system friction loss. Recirculation Pump - O
Remote Room Air Temperature Sensor PQRSTA0 O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install
Magnetic Filter Default, PREMTW101 for
the magnetic filter to protect heat pump system. Standard III Remote Controller O
2 Remo control
A water tank containing certain amount of water that secures the required minimum water volume for the system Solar Pump - O
Buffer Tank or stores heat energy which is needed for defrosting and reducing start up load. Safety Relief Valve - O
A motorized isolation valve that blocks the water flow into underfloor coil in order to prevent water condensation Strainer - O
2 Way Valve during cooling mode. Solar Temperature Sensor (PT-1000) - O
Controlled by THERMA V with 230V power. Required operating time : less than 90s. Service Valve - O
Thermostat - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers. OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #5 SPACE HEATING AND COOLING WITH 2 REMOTE CONTROLLERS
LG ACCESSORIES

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & Cooling with 2 Remote Controllers
Product R32 Monobloc S (New) Wi-Fi Modem (PWFMDD200)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
UFH(H) + FCU(H&C) A control device that enables wireless
Terminal Device
communication with internet router.
Main Controller LG RS3 Controllers Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Including USB cable 0.6m and extension cable
Control Setting of LG RS3 Controller Based on Air Temp. or Water Temp. 0.5m
External Pump Controlled by THERMA V Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
In 2-remo control, RS3 MASTER shows a temperature measured by LG Extension Cable for Wi-Fi Modem
(PWYREW000)
Remark built-in sensor in RS3 SLAVE. (Temperature value measured by RS3 Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem Cable Length 10m
MASTER is overriden.) LG

RS3 SLAVE Controller (PREMTW101)


Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
An additional wired remote controller with built-in
temperature sensor that enables controlling
Drain Pressure Reducing Valve Drain Pan Cover Plate THERMA V using two remote controller.
Including extension wire(PZCWRC1) and 2 remo
cable(PZCWRC2)

Extension Wire for RS3 Controller (PZCWRC1)


Cable length 10m. Included in PREMTW101.

SPACE HEATING AREA 2 Remo Cable (PZCWRC2)


A cable that enables connecting two remote
controller on the one indoor unit.
RS3 Included in PREMTW101.
SLAVE
COOLING CIRCUIT

FCU UFH
3RD PARTY ACCESSORIES

External Pump
An external water pump that circulates the water
POWER SUPPLY
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
total system friction loss.
RS3
MASTER Magnetic Filter (Recommended)
A magnetic filter that collects metallic particle
2-REMO
CABLE

caused by corrosion or erosion. It is strongly


recommended to install the magnetic filter to
protect heat pump system.
1Ø 220-240V AC or 3Ø 380-415V AC

BUILT IN COMPONENTS
Buffer Tank
- Plate Type Heat Ex.
- Water pump A water tank containing certain amount of water
- Expansion vessel (8 L) POWER that secures the required minimum water volume
CN_REMO

- Safety valve (3 bar) WI-FI SUPPLY for the system or stores heat energy which is
- Pressure sensor MODEM needed for defrosting and reducing start up load.
- Strainer (30 mesh)
- Flow sensor LG 2 Way Valve
MAGNETIC A motorized isolation valve that blocks the water
CONTACTOR 2 WAY flow into underfloor coil in order to prevent water
VALVE condensation during cooling mode.
LG
CN_WF Controlled by THERMA V with 230V power.
Required operating time : less than 90s.
TB1 4 / 6
THERMA V

TB_EXT_PUMP A2 DIFFERENTIAL Differential Pressure Valve


EXTERNAL PUMP PRESSURE
VALVE
A self pressure regulating valve that provides
DN25
constant differential pressure between supply and
DN25 return headers.
MAKE UP WATER

SERVICE
THERMA V R32 MONOBLOC S VALVE

MAGNETIC FILTER
BUFFER TANK
(RECOMMENDED)

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #5 SPACE HEATING AND COOLING WITH 2 REMOTE CONTROLLERS
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
ON
OFF
1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

SW2

L
ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
1 2 3 4 5 6 7 8
L

X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS
2 WAY Communication
Master (Link to LG controller) X

VALVE
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

Antifreeze is not applied X


Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X
RS3
N

MASTER
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


RS3
L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR SLAVE
Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
Air Sensor installed
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
EXTERNAL
VALVE (A)

Full capacity is used O O


2 WAY VALVE
2 WAY

PUMP Thermostat Thermostat is not installed X


L1
5

- L : on Voltage when Cooling is active (NO Valve) Installation Thermostat is installed O


CN_ROOM1

- L1 : on Voltage when Cooling is not active (NC Valve) default setting X X X X X X X X


4
L

230 V AC
BR BR BL

N
3
MIXING
VALVE

L1
2

MAIN PCB (CYCLE)


TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

L N there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

MAGNETIC
TB_EXT

X : OFF / O : ON
CONTACTOR
L3

DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

Max mode X
21 22 23 24
BL BR WH BK

L2

Peak Control Peak control : To limit maximum


O
current (Power saving)
TB2 & TB3

default setting X
POWER X
L1

SUPPLY
1Ø 220 ~ 240 V AC
CN_MIX_OUT
N
L

NOTE

WIFI MODEM
1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model 2-REMO
CABLE 2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.

Power supply of
Main T/B R
CN_WF

POWER S T N the 3 Phase Model


SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #6 SPACE HEATING WITH 3RD PARTY CONTROLLER (MODBUS) REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
Expansion Tank For IWT, OSHE-12KT (DHW Circuit) O O
Flexible Connection - O
Fan Coil Unit - O
Flow Sensor - O
3rd party accessories
Heat Meter - O
Full Name Description OSHW-200F (Single Coil, 200L)
OSHW-300F (Single Coil, 300L)
Domestic Hot Water Tank OSHW-500F (Single Coil, 500L) O O
An external water pump that circulates the water inside piping when water circuit is segregated or pump
External Pump OSHW-300FD (Double Coil, 300L)
discharge head is insufficient to overcome total system friction loss.
Isolation Valve - O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install PACEZA000 (AC Ez Touch)
Magnetic Filter
the magnetic filter to protect heat pump system. LG Central Controller PACS5A000 (AC Smart 5) O
PACP5A000 (ACP 5)
A water tank containing certain amount of water that secures the required minimum water volume for the system
Buffer Tank or stores heat energy which is needed for defrosting and reducing start up load. Magnetic Contactor - O O
Magnetic Filter - O
A control device that uses the analogue or digital signals from various devices and then process and control the Meter Interface PENKTH000 O
Direct Digital Controller system based on the program written inside the controllers and has the capability to sends the information to
Mixing Pump - O
another controller.
Mixing Zone Temperature Sensor PRSTAT5K10 O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers. Mixing Valve - O
PI485 Gateway PMNFP14A1 O
Pressure Gauge - O
Plate Heat Exchanger - O
Radiator - O
Recirculation Pump - O
Remote Room Air Temperature Sensor PQRSTA0 O
Default, PREMTW101 for
Standard III Remote Controller O
2 Remo control
Solar Pump - O
Safety Relief Valve - O
Strainer - O
Solar Temperature Sensor (PT-1000) - O
Service Valve - O
Thermostat - O
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #6 SPACE HEATING WITH 3RD PARTY CONTROLLER (MODBUS)
ACCESSORIES LG

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating with 3rd Party Controller (MODBUS)
Product R32 Monobloc S (New)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Terminal Device RAD
Main Controller LG RS3 Controller & 3rd Party Controller Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor
Control Setting of LG RS3 Controller Based on Air Temp. or Water Temp.
External Pump Controlled by Therma V Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG

Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem


LG

3RD PARTY
DDC / PLC
CONTROL SYSTEM Flexible Connection Shut Off Valve Magnetic Contactor Thermostat

Drain Pressure Reducing Valve Drain Pan Cover Plate

SPACE HEATING AREA


POWER
SUPPLY RAD RAD

POWER
1Ø 220-240V AC or 3Ø 380-415V AC

SUPPLY RS3
3RD PARTY ACCESSORIES

MAGNETIC
CONTACTOR External Pump
An external water pump that circulates the water
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
TB3
26 / 27
total system friction loss.
LG CN_REMO
Magnetic Filter (Recommended)
TB_EXT_PUMP A2 A magnetic filter that collects metallic particle
THERMA V caused by corrosion or erosion. It is strongly
DIFFERENTIAL recommended to install the magnetic filter to
DN25 PRESSURE
EXTERNAL PUMP protect heat pump system.
BUFFER TANK VALVE
DN25 Buffer Tank
MAKE UP WATER A water tank containing certain amount of water
that secures the required minimum water volume
SERVICE for the system or stores heat energy which is
THERMA V R32 MONOBLOC S #2 VALVE MAGNETIC FILTER needed for defrosting and reducing start up load.
(RECOMMENDED)

DDC (Direct Digital Controller)


A control device that uses the analogue or digital
signals from various devices and then process and
control the system based on the program written
inside the controllers and has the capability to
sends the information to another controller.
SPACE HEATING AREA
Differential Pressure Valve
POWER A self pressure regulating valve that provides
SUPPLY RAD RAD
constant differential pressure between supply and
POWER return headers.
1Ø 220-240V AC or 3Ø 380-415V AC

SUPPLY RS3
TB3 26 / 27

MAGNETIC
CONTACTOR

LG CN_REMO

TB_EXT_PUMP A2
THERMA V

DIFFERENTIAL
DN25 PRESSURE
EXTERNAL PUMP
BUFFER TANK VALVE
DN25
MAKE UP WATER

SERVICE
THERMA V R32 MONOBLOC S #1 VALVE MAGNETIC FILTER
(RECOMMENDED)

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #6 SPACE HEATING WITH 3RD PARTY CONTROLLER (MODBUS)
DIP SWITCH SETTINGS

WIRING DIAGRAM 3RD PARTY


DDC MAIN PCB (HYDRO)
CONTROL SYSTEM
SW1

ON
OFF
1 2 3 4 5 6 7 8

SW2
MONOBLOC UNIT #1 MONOBLOC UNIT #2
ON
OFF
1 2 3 4 5 6 7 8
10 11 12 13 14 15 16 17 18 19 20

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)

PUMP (C)
BR BL

BR BL
N

N
WATER

WATER
X : OFF / O : ON
L

L
DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
MIX PUMP

MIX PUMP
Communication
BR BL BR BL BR BL

BR BL BR BL BR BL
N

N
Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
L

L
Antifreeze is not applied X
Antifreeze Mode Antifreeze is applied (Adjustable
PUMP (B)

PUMP (B)
O
N

N
anti-freeze temp.)
WATER

WATER
default setting X X X
L

L
DIP SW 2 1 2 3 4 5 6 7 8
Indoor Unit Type As Master X
Setting for Group
W.TANK

W.TANK
HEATER

HEATER
N

N
Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
Accessory
L

L
Installation Heat pump + DHW tank are installed X O
Information Heat pump + DHW tank + Solar
O X
BR WH BL BR WH BL BR WH BL

BR WH BL BR WH BL BR WH BL
thermal system are installed
N

N
VALVE (B)

VALVE (B)
Heating only X
Heat Pump Cycle
3 WAY

3 WAY
Heating and cooling O
L1

L1
CN_TH4

CN_TH4
TB_SENSOR

TB_SENSOR
SOLAR SOLAR Remote Room Remote room air sensor is not
installed
X
Air Sensor
(Accessory)
DEW DEW Remote room air sensor is installed O
L

L
Backup heater is not used X X
Selecting Backup
AMBIENT AMBIENT Heater Capacity
Half capacity is used O X
N

N
9

9
VALVE (A)

VALVE (A)
Full capacity is used O O
3 WAY

3 WAY
Thermostat Thermostat is not installed X
L1

L1
8

8
Installation Thermostat is installed O
CN_ROOM2

CN_ROOM2
default setting X X X X X X X X
7

7
L

L
N

N
6
6

EXTERNAL EXTERNAL
VALVE (A)

VALVE (A)
2 WAY

2 WAY
PUMP PUMP
L1

L1
5

5
CN_ROOM1

CN_ROOM1
MAIN PCB (CYCLE)
4

4
L

L
SW1
BR BR BL

BR BR BL
N

N
3

3
ON For 5/7/9 kW models,
MIXING

MIXING
VALVE

VALVE
OFF there is no No.6 pin.
L1

L1
2

2
1 2 3 4 5 6
TB1

TB1
1

1
L

L
X : OFF / O : ON
DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
RD BK WH

RD BK WH
Controller

Controller
25 26 27

25 26 27
3rd Party

3rd Party
Low Noise Mode
L N L N
B

B
Partial mode : Escape low noise
mode for target temperature O

Max mode X
BOILER PUMP A2

BOILER PUMP A2
A

A
Peak Control Peak control : To limit maximum
O
MAGNETIC MAGNETIC current (Power saving)
TB_EXT

TB_EXT
CONTACTOR CONTACTOR default setting X X
L3

L3
EXT

EXT
(Default 230 V AC)

(Default 230 V AC)


THERMOSTAT

THERMOSTAT
21 22 23 24

21 22 23 24
BL BR WH BK

BL BR WH BK

L2
L2

1Φ 220-240V AC

1Φ 220-240V AC
NOTE
TB2 & TB3

TB2 & TB3


POWER POWER
L1

L1
SUPPLY SUPPLY
CN_MIX_OUT

CN_MIX_OUT
N

N
1. The wiring cable size and Circuit breaker selection
must comply with installation manual and
L

L
applicable local regulations.

2. Make sure that Earth Leakage Circuit Breaker


RS3 RS3 (ELCB) should be installed for power supply line.
CN_REMO

CN_REMO
COMMON

COMMON
HEATER1

HEATER2

HEATER1

HEATER2
3 PHASE

3 PHASE
POWER POWER
Power supply of Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT 1Ø 220 ~ 240 V AC TB_HEAT_CONTACT

Power supply of Power supply of


Main T/B R
CN_WF

Main T/B R

CN_WF
POWER S T N the 3 Phase Model
POWER S T N the 3 Phase Model
SUPPLY SUPPLY
3Ø 380 ~ 415 V AC 3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #7 SPACE HEATING WITH PARALLEL INSTALLATION (LG BECON) REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
A central controller that controls THERMA V using LG AP protocol. Expansion Tank For IWT, OSHE-12KT (DHW Circuit)
AC EZ TOUCH PACEZA000 O O
Max 64 units, PC access supported
Flexible Connection - O
A gateway device that communicates and controls through the central controller. Fan Coil Unit - O
PI485 Gateway (converting LG protocol to RS485 protocol) PMNFP14A1 Flow Sensor - O
It should be installed onto the outdoor unit. Heat Meter - O
OSHW-200F (Single Coil, 200L)
OSHW-300F (Single Coil, 300L)
Domestic Hot Water Tank OSHW-500F (Single Coil, 500L) O O
3rd party accessories OSHW-300FD (Double Coil, 300L)
Isolation Valve - O
Full Name Description
PACEZA000 (AC Ez Touch)
LG Central Controller PACS5A000 (AC Smart 5) O
An external water pump that circulates the water inside piping when water circuit is segregated or pump
External Pump PACP5A000 (ACP 5)
discharge head is insufficient to overcome total system friction loss.
Magnetic Contactor - O O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install Magnetic Filter - O
Magnetic Filter
the magnetic filter to protect heat pump system. Meter Interface PENKTH000 O
Mixing Pump - O
A water tank containing certain amount of water that secures the required minimum water volume for the system
Buffer Tank Mixing Zone Temperature Sensor PRSTAT5K10 O
or stores heat energy which is needed for defrosting and reducing start up load.
Mixing Valve - O
A control device that senses the temperature of a room and performs actions so that the room's temperature is
PI485 Gateway PMNFP14A1 O
Thermostat maintained near a desired setpoint.
Thermostat must be connected with Therma V, Valve, Pump, and FCU where applicable. Pressure Gauge - O
Plate Heat Exchanger - O
2 Way Valve for A isolation valve paired with thermostat to allow whether water flows into the water circuit. Radiator - O
Thermostat
Recirculation Pump - O
Remote Room Air Temperature Sensor PQRSTA0 O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers.
Default, PREMTW101 for
Standard III Remote Controller O
2 Remo control
Solar Pump - O
Safety Relief Valve - O
Strainer - O
Solar Temperature Sensor (PT-1000) - O
Service Valve - O
Thermostat - O
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #7 SPACE HEATING WITH PARALLEL INSTALLATION (LG BECON)
ACCESSORIES LG

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating with Parallel Installation
Product R32 Monobloc S (New) AC Ez Touch (PACEZA000)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
A central controller that controls THERMA V using
Terminal Device RAD
LG AP protocol.
Main Controller LG Central Controller & Thermostat Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Max 64 units, PC access supported
Control Setting of LG RS3 Controller Based on Water Temp.
External Pump Controlled by Thermostat Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
PI485 Gateway (PMNFP14A1)
LG A gateway device that communicates and controls
through the central controller. (converting LG
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem protocol to RS485 protocol)
It should be installed onto the outdoor unit.
LG

Flexible Connection Shut Off Valve Magnetic Contactor Thermostat

Drain Pressure Reducing Valve Drain Pan Cover Plate

POWER
SUPPLY SPACE HEATING AREA

THERMOSTAT 1 THERMOSTAT 2
MAGNETIC
CONTACTOR 3RD PARTY ACCESSORIES

POWER RAD RAD


SUPPLY External Pump
An external water pump that circulates the water
inside piping when water circuit is segregated or
pump discharge head is insufficient to overcome
total system friction loss.
1Ø 220-240V AC or 3Ø 380-415V AC

1Ø 220-240V AC or 3Ø 380-415V AC

BUILD-IN COMPONENTS: Magnetic Filter (Recommended)


- Plate Type Heat Ex. 2 WAY VALVE FOR 2 WAY VALVE FOR
A magnetic filter that collects metallic particle
- Water pump THERMOSTAT THERMOSTAT
- Expansion vessel (8 L)
caused by corrosion or erosion. It is strongly
- Safety valve (3 bar) recommended to install the magnetic filter to
- Pressure Gauge protect heat pump system.
- Strainer (28 mesh)
- Flow switch
- PI485 Gateway (Accessory) AC EZ TOUCH Buffer Tank
A water tank containing certain amount of water
that secures the required minimum water volume
for the system or stores heat energy which is
needed for defrosting and reducing start up load.
RS3
PI485
LG CN_REMO Thermostat
DN32 A control device that senses the temperature of a
room and performs actions so that the room's
THERMA V

DIFFERENTIAL temperature is maintained near a desired setpoint.


EXTERNAL PUMP PRESSURE Thermostat must be connected with Therma V,
DN25 VALVE Valve, Pump, and FCU where applicable.

2 Way Valve for Thermostat


MAKE UP WATER A isolation valve paired with thermostat to allow
DN25 DN32 whether water flows into the water circuit.
SERVICE
THERMA V R32 MONOBLOC S #2 VALVE
MAGNETIC FILTER Differential Pressure Valve
(RECOMMENDED) A self pressure regulating valve that provides
constant differential pressure between supply and
return headers.
BUFFER TANK
PI485
LG RS3

CN_REMO

THERMA V

DN25

SERVICE DN25
THERMA V R32 MONOBLOC S #1 VALVE
MAGNETIC FILTER
(RECOMMENDED)

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #7 SPACE HEATING WITH PARALLEL INSTALLATION (LG BECON)
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT #1 MONOBLOC UNIT #2
ON
EXTERNAL OFF
PUMP 1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)

PUMP (C)
BR BL

BR BL
N

N
WATER

WATER
SW2

L
ON
MIX PUMP

MIX PUMP
BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL
N

N
OFF
L N 1 2 3 4 5 6 7 8
L

L
X : OFF / O : ON
PUMP (B)

PUMP (B)
N

N
WATER

WATER
DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
THERMOSTAT Communication
L

L
Type Slave (Link to 3rd party controller) O
(3rd party)
MODBUS REGINE X
Function Unified Open Protocol O
W.TANK

W.TANK
HEATER

HEATER
N

N
Antifreeze is not applied X

CN_TH4

CN_TH4
Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

L
default setting X X X
N

N
VALVE (B)

VALVE (B)
DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

3 WAY
Indoor Unit Type As Master X
L1

L1
Setting for Group
TB_SENSOR

TB_SENSOR
SOLAR SOLAR MAGNETIC Control As Slave O
Heat pump installation (Heating or
CONTACTOR X X

CN_ROOM2

CN_ROOM2
cooling circuit only)
DEW DEW Accessory
L

L
Installation Heat pump + DHW tank are installed X O
Information
AMBIENT AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N

N
9

9
VALVE (A)

VALVE (A)
Heating only X
Heat Pump Cycle
3 WAY

3 WAY
Heating and cooling O
L1

L1
8

8
Remote Room Remote room air sensor is not
X
installed
POWER Air Sensor
(Accessory)
SUPPLY
7

7
Remote room air sensor is installed O
L

L
CN_ROOM1

CN_ROOM1
Backup heater is not used X X
1Ø 220 ~ 240 V AC Selecting Backup
Half capacity is used O X
N

N
6

6
Heater Capacity
VALVE (A)

VALVE (A)
Full capacity is used O O
2 WAY

2 WAY
Thermostat Thermostat is not installed X
L1

L1
5

5
Installation Thermostat is installed O
default setting X X X X X X X X
4

4
L

L
BR BR BL

BR BR BL
N

N
3

3
MIXING

MIXING
VALVE

VALVE
L1

L1
2

2
MAIN PCB (CYCLE)
TB1

TB1
1

1
L

L
SW1
BOILER PUMP A2

BOILER PUMP A2
TB_EXT

TB_EXT
ON For 5/7/9 kW models,
RD BK WH

RD BK WH
Controller

Controller
OFF
25 26 27

25 26 27
3rd Party

3rd Party
there is no No.6 pin.
B

B
1 2 3 4 5 6
EXT

EXT
A

A
X : OFF / O : ON
L3

L3
DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
(Default 230 V AC)

(Default 230 V AC)


mode for target temperature
THERMOSTAT

THERMOSTAT
CN_MIX_OUT

CN_MIX_OUT
Max mode X
21 22 23 24

21 22 23 24
BL BR WH BK

BL BR WH BK
L2

L2
Peak Control Peak control : To limit maximum
O
current (Power saving)
COMMON

COMMON
HEATER1

HEATER2

HEATER1

HEATER2
3 PHASE

3 PHASE
TB2 & TB3

TB2 & TB3 default setting X X


L1

L1
N

N
TB_HEAT_CONTACT RS3 TB_HEAT_CONTACT RS3
L

L
CN_REMO

CN_REMO
NOTE
POWER POWER
Power supply of Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
1. The wiring cable size and Circuit breaker selection
1Ø 220 ~ 240 V AC 1Ø 220 ~ 240 V AC
must comply with installation manual and
applicable local regulations.
CN_WF

CN_WF
Power supply of Power supply of 2. Make sure that Earth Leakage Circuit Breaker
POWER Main T/B R S T N the 3 Phase Model
POWER Main T/B R S T N the 3 Phase Model
SUPPLY SUPPLY (ELCB) should be installed for power supply line.
3Ø 380 ~ 415 V AC 3Ø 380 ~ 415 V AC

CN_CP_L CN_CP_N CN_CP_L CN_CP_N

CN_CENTRAL(WH) CN_CENTRAL(WH) AC EZ TOUCH


(PACEZA000)
PI485 GATEWAY BUS PI485 GATEWAY BUS

(PMNFP14A1) CN_OUT 1 2 3 A B (PMNFP14A1) CN_OUT 1 2 3 A B


CN_PWR CN_PWR
DWG NO. :
REFERENCED APPLICATION #8 SPACE HEATING AND DHW WITH RECIRCULATION PUMP REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
A control device that enables wireless communication with internet router. Expansion Tank For IWT, OSHE-12KT (DHW Circuit)
Wi-Fi Modem PWFMDD200 O O
Including USB cable 0.6m and extension cable 0.5m
Flexible Connection - O
Fan Coil Unit - O
Extension Cable for Cable Length 10m Flow Sensor - O
PWYREW000
Wi-Fi Modem
Heat Meter - O
A motorized 3-way diverting valve determining flow direction to either space heating or OSHW-200F (Single Coil, 200L)
3 Way Valve (A) DHW tank. OSHW-300F (Single Coil, 300L)
OSHA-3V Domestic Hot Water Tank O O
Controlled by THERMA V with 230V power. Operating time 3s. OSHW-500F (Single Coil, 500L)
OSHW-300FD (Double Coil, 300L)
A insulated stainless steel hot water tank with 2.4kW electric heating (230V). Isolation Valve - O
Domestic Hot Water Single coil w/ recir. port :
Single Coil : OSHW-200F(200L) / 300F(300L, w/ recir. port) / 500F(500L, w/ recir. port) PACEZA000 (AC Ez Touch)
Tank Double coil : OSHW-300FD(300L, w/ recir. port) OSHW-300F/500F
LG Central Controller PACS5A000 (AC Smart 5) O
PACP5A000 (ACP 5)
DHW Tank Sensor A temperature sensor for DHW tank. Cable length 12m. PHRSTA0 Magnetic Contactor - O O
Magnetic Filter - O
Thermostatic Mixing A mixing valve that blends hot water with cold water to ensure constant, safe shower OSHA-MV (3/4")
Meter Interface PENKTH000 O
Valve and bath outlet temperatures, preventing scalding. OSHA-MV1 (1")
Mixing Pump - O
Mixing Zone Temperature Sensor PRSTAT5K10 O
Mixing Valve - O
PI485 Gateway PMNFP14A1 O
3rd party accessories Pressure Gauge - O
Plate Heat Exchanger - O
Full Name Description Radiator - O
Recirculation Pump - O
An external water pump that circulates the water inside piping when water circuit is segregated or pump
External Pump Remote Room Air Temperature Sensor PQRSTA0 O
discharge head is insufficient to overcome total system friction loss.
Default, PREMTW101 for
Standard III Remote Controller O
An external water pump that circulates the water inside DHW circuit. 2 Remo control
Recirculation Pump Solar Pump - O
Controlled by THERMA V with 230V power.
Safety Relief Valve - O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install Strainer - O
Magnetic Filter
the magnetic filter to protect heat pump system.
Solar Temperature Sensor (PT-1000) - O
A water tank containing certain amount of water that secures the required minimum water volume for the system Service Valve - O
Buffer Tank
or stores heat energy which is needed for defrosting and reducing start up load. Thermostat - O
OSHA-MV
Thermostatic Mixing Valve O O
A self pressure regulating valve that provides constant differential pressure between supply and return headers. OSHA-MV1
Differential Pressure Valve
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #8 SPACE HEATING AND DHW WITH RECIRCULATION PUMP
ACCESSORIES LG

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & DHW
Product R32 Monobloc S (New) Wi-Fi Modem (PWFMDD200)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
A control device that enables wireless
Terminal Device UFH
communication with internet router.
Main Controller LG RS3 Controller Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Including USB cable 0.6m and extension cable
Control Setting of LG RS3 Controller Based on Air Temp. or Water Temp. 0.5m
External Pump Controlled by THERMA V Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG Extension Cable for Wi-Fi Modem
(PWYREW000)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem Cable Length 10m
LG

3 Way Valve (A) (OSHA-3V)


Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
A motorized 3-way diverting valve determining flow
direction to either space heating or DHW tank.
Drain Pressure Reducing Valve Drain Pan Cover Plate Controlled by THERMA V with 230V power.
Operating time 3s.

Domestic Hot Water Tank (OSHW-300F/500F)


A insulated stainless steel hot water tank with
2.4kW electric heating (230V) and recirculation
port.
Single Coil : OSHW-300F(300L) / 500F(500L)

DHW Tank Sensor (PHRSTA0)


SPACE HEATING AREA A temperature sensor for DHW tank. Cable length
RS3 12m.

Thermostatic Mixing Valve (OSHA-MV,


OSHA-MV1)
UFH UFH A mixing valve that blends hot water with cold
DHW TANK
water to ensure constant, safe shower and bath
outlet temperatures, preventing scalding.

HOT WATER

POWER SUPPLY
THERMOSTATIC
RECIR. MIXING VALVE
PUMP (OPTION)

3RD PARTY ACCESSORIES


1Ø 220-240V AC or 3Ø 380-415V AC

DHW TANK External Pump


BUILT IN COMPONENTS SENSOR An external water pump that circulates the water
- Plate Type Heat Ex. CITY WATER SUPPLY inside piping when water circuit is segregated or
- Water pump pump discharge head is insufficient to overcome
- Expansion vessel (8 L)
TB1 7 / 8 / 9

total system friction loss.


TB1 19 / 20
CN_REMO

- Safety valve (3 bar)


CN_TH4

3 WAY
- Pressure sensor DN25 POWER
VALVE (A)
- Strainer (30 mesh) SUPPLY Recirculation Pump
WI-FI
- Flow sensor DN25 An external water pump that circulates the water
MODEM
inside DHW circuit.
Controlled by THERMA V with 230V power.
MAGNETIC
LG

LG CONTACTOR
Magnetic Filter (Recommended)
DN25
CN_WF A magnetic filter that collects metallic particle
THERMA V
TB_EXT_PUMP A2 caused by corrosion or erosion. It is strongly
DIFFERENTIAL recommended to install the magnetic filter to
EXTERNAL PUMP PRESSURE protect heat pump system.
DN25 VALVE

DN25 DN25
Buffer Tank
A water tank containing certain amount of water
MAKE UP WATER
that secures the required minimum water volume
for the system or stores heat energy which is
SERVICE
THERMA V R32 MONOBLOC S VALVE needed for defrosting and reducing start up load.

MAGNETIC FILTER Differential Pressure Valve


BUFFER TANK A self pressure regulating valve that provides
(RECOMMENDED)
constant differential pressure between supply and
return headers.

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #8 SPACE HEATING AND DHW WITH RECIRCULATION PUMP
DIP SWITCH SETTINGS

WIRING DIAGRAM
DHW TANK HEATING SYSTEM MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
ON
RECIRCULATION OFF
PUMP 1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

230 V AC SW2

L
ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N
For General Case OFF
1 2 3 4 5 6 7 8
3 WAY
L

VALVE (A)
X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
L For OSHA-3V Communication
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
2 3 WAY Function Unified Open Protocol O
W.TANK
HEATER

3
6 VALVE (A) Antifreeze is not applied X
Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


DHW TANK
L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR SENSOR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
230 V AC / space heating Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
EXTERNAL X
installed
230 V AC / DHW heating Air Sensor
PUMP (Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


2 WAY

Thermostat Thermostat is not installed X


L1
5

Installation Thermostat is installed O


CN_ROOM1
default setting X X X X X X X X
4
L
BR BR BL

N
3
MIXING
VALVE

L1
2

MAIN PCB (CYCLE)


TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

L N there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

MAGNETIC
TB_EXT

X : OFF / O : ON
CONTACTOR
L3

DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

Max mode X
21 22 23 24
BL BR WH BK

L2

Peak Control Peak control : To limit maximum


O
current (Power saving)
TB2 & TB3

default setting X
POWER X
L1

SUPPLY
1Ø 220 ~ 240 V AC
CN_MIX_OUT
N
L

NOTE
RS3
WIFI MODEM
1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.

Power supply of
Main T/B R
CN_WF

POWER S T N the 3 Phase Model


SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #9 SPACE HEATING AND DHW WITH BOOSTER HEATER REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION
Direct Digital Controller - O
Differential Pressure Valve - O
LG supplied accessories
PHLTA (Hydrosplit, 1Ø Split)
Full Name Description Part No. DHW Tank Kit PHLTC (3Ø, Split) O
PHLTB (Monobloc)
A wired remote controller with built-in temperature sensor. DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
RS3 wired remote
Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default
controller Drain Pan PHDPC O
extension cable (PZCWRC1)
Drain Valve - O
A control device that enables wireless communication with internet router. External Boiler - O
Wi-Fi Modem Including USB cable 0.6m and extension cable 0.5m PWFMDD200 Energy Meter - O
Extension Cable for Wi-Fi Modem PWYREW000 O O
Extension Cable for Extension Wire for RS3 Controller PZCWRC1 O
Cable Length 10m PWYREW000 External Pump
Wi-Fi Modem - O
Expansion Tank For IWT, OSHE-12KT (DHW Circuit) O O
A motorized 3-way diverting valve determining flow direction to either space heating or Flexible Connection - O
3 Way Valve (A) DHW tank. OSHA-3V
Fan Coil Unit - O
Controlled by THERMA V with 230V power. Operating time 3s.
Flow Sensor - O
A insulated stainless steel hot water tank with 2.4kW electric heating (230V). Heat Meter - O
Domestic Hot Water Single Coil : OSHW-200F(200L) / 300F(300L) / 500F(500L) Single coil :
Tank OSHW-200F/300F/500F OSHW-200F (Single Coil, 200L)
Double coil : OSHW-300FD(300L) OSHW-300F (Single Coil, 300L)
Domestic Hot Water Tank OSHW-500F (Single Coil, 500L) O O
An electric heater for DHW heating integrated with DHW tank (2.4kW, 230V)
DHW Booster Heater Integrated with DHW Tank
Controlled by THERMA V with 230V power. OSHW-300FD (Double Coil, 300L)
Isolation Valve - O
A set of electrical devices for controlling of electric booster heater up to 32A PACEZA000 (AC Ez Touch)
DHW Tank Kit PHLTB (Monobloc)
Including Circuit Breaker, Magnetic Contactor and DHW Temp. sensor (PHRSTA0) PACS5A000 (AC Smart 5)
LG Central Controller O
PACP5A000 (ACP 5)
DHW Tank Temperature PHRSTA0, Included in Magnetic Contactor - O O
A temperature sensor for DHW tank. Cable length 12m.
Sensor DHW Tank Kit (PHLTB) Magnetic Filter - O
Meter Interface PENKTH000 O
Thermostatic Mixing A mixing valve that blends hot water with cold water to ensure constant, safe shower OSHA-MV (3/4") Mixing Pump - O
Valve and bath outlet temperatures, preventing scalding. OSHA-MV1 (1") Mixing Zone Temperature Sensor PRSTAT5K10 O
Mixing Valve - O
PI485 Gateway PMNFP14A1 O
Pressure Gauge - O
3rd party accessories Plate Heat Exchanger - O
Radiator - O
Full Name Description Recirculation Pump - O
Remote Room Air Temperature Sensor PQRSTA0 O
An external water pump that circulates the water inside piping when water circuit is segregated or pump
External Pump Default, PREMTW101 for
discharge head is insufficient to overcome total system friction loss. Standard III Remote Controller O
2 Remo control
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install Solar Pump - O
Magnetic Filter Safety Relief Valve
the magnetic filter to protect heat pump system. - O
Strainer - O
A water tank containing certain amount of water that secures the required minimum water volume for the system
Buffer Tank Solar Temperature Sensor (PT-1000) - O
or stores heat energy which is needed for defrosting and reducing start up load.
Service Valve - O
Thermostat - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers.
OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #9 SPACE HEATING AND DHW WITH BOOSTER HEATER
ACCESSORIES LG

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & DHW
Product R32 Monobloc S (New) Wi-Fi Modem (PWFMDD200)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
A control device that enables wireless
Terminal Device UFH
communication with internet router.
Main Controller LG RS3 Controller Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Including USB cable 0.6m and extension cable
Control Setting of LG RS3 Controller Based on Air Temp. or Water Temp. 0.5m
External Pump Controlled by THERMA V Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG Extension Cable for Wi-Fi Modem
(PWYREW000)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem Cable Length 10m
LG

3 Way Valve (A) (OSHA-3V)


Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
A motorized 3-way diverting valve determining flow
direction to either space heating or DHW tank.
Drain Pressure Reducing Valve Drain Pan Cover Plate Controlled by THERMA V with 230V power.
Operating time 3s.

Domestic Hot Water Tank


(OSHW-200F/300F/500F)
A insulated stainless steel hot water tank with
2.4kW electric heating (230V).
Single Coil : OSHW-200F(200L) / 300F(300L) /
500F(500L)

SPACE HEATING AREA DHW Booster Heater (Integrated with DHW


RS3 Tank)
An electric heater for DHW heating integrated with
DHW tank (2.4kW, 230V)
Controlled by THERMA V with 230V power.
RAD RAD
DHW Tank Kit (PHLTB)
A set of electrical devices for controlling of electric
booster heater up to 32A
HOT WATER Including Circuit Breaker, Magnetic Contactor and
DHW Temp. sensor (PHRSTA0)
POWER SUPPLY
THERMOSTATIC DHW Tank Sensor (PHRSTA0)
MIXING VALVE A temperature sensor for DHW tank. Cable length
(OPTION) 12m. Included in DHW Tank Kit (PHLTB)
1Ø 220-240V AC
Thermostatic Mixing Valve (OSHA-MV,
OSHA-MV1)
A mixing valve that blends hot water with cold
1Ø 220-240V AC or 3Ø 380-415V AC

DHW TANK water to ensure constant, safe shower and bath


KIT DHW TANK BOOSTER
BUILT IN COMPONENTS SENSOR HEATER outlet temperatures, preventing scalding.
- Plate Type Heat Ex. CITY WATER SUPPLY
- Water pump
- Expansion vessel (8 L)
TB1 7 / 8 / 9
CN_REMO

- Safety valve (3 bar)


CN_TH4

3 WAY DN25 POWER


- Pressure sensor
WI-FI VALVE (A) SUPPLY
- Strainer (30 mesh)
MODEM DN25
- Flow sensor
3RD PARTY ACCESSORIES
LG

MAGNETIC
LG CN_WF
CONTACTOR External Pump
DN25 An external water pump that circulates the water
TB1 13 / 14
TB_EXT_PUMP A2 inside piping when water circuit is segregated or
THERMA V
pump discharge head is insufficient to overcome
DIFFERENTIAL
PRESSURE total system friction loss.
EXTERNAL PUMP
DN25 VALVE
Magnetic Filter (Recommended)
DN25 DN25 A magnetic filter that collects metallic particle
MAKE UP WATER caused by corrosion or erosion. It is strongly
recommended to install the magnetic filter to
SERVICE protect heat pump system.
THERMA V R32 MONOBLOC S VALVE

Buffer Tank
MAGNETIC FILTER
BUFFER TANK A water tank containing certain amount of water
(RECOMMENDED)
that secures the required minimum water volume
for the system or stores heat energy which is
needed for defrosting and reducing start up load.

Differential Pressure Valve


A self pressure regulating valve that provides
constant differential pressure between supply and
return headers.

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #9 SPACE HEATING AND DHW WITH BOOSTER HEATER
DIP SWITCH SETTINGS

WIRING DIAGRAM DHW TANK KIT (PHLTB)


MAIN PCB (HYDRO)
POWER HEATER
SIGNAL SW1
MONOBLOC UNIT SUPPLY COIL

BR BL BR BL RD YL ON
DHW TANK HEATING SYSTEM
1(L) 2(N) 3(L) 4(N) 5 OFF
6
1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER

POWER
SUPPLY SW2

L
1Ø 220 ~ 240 V AC
ON
MIX PUMP

BOOSTER
BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N HEATER OFF
1 2 3 4 5 6 7 8
L

X : OFF / O : ON
PUMP (B)

For General Case


N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
3 WAY Communication
CN_TANK_HEATER

Type Slave (Link to 3rd party controller) O


VALVE (A)
MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

L For OSHA-3V Antifreeze is not applied X


230 V AC Antifreeze Mode Antifreeze is applied (Adjustable
O
2 3 WAY anti-freeze temp.)
L

3 default setting X X X
6 VALVE (A)
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


DHW TANK Information
AMBIENT SENSOR
Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
230 V AC / space heating Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
installed
230 V AC / DHW heating Air Sensor
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


2 WAY

Thermostat Thermostat is not installed X


EXTERNAL
L1
5

Installation Thermostat is installed O


PUMP
CN_ROOM1
default setting X X X X X X X X
4
L
BR BR BL

N
3
MIXING
VALVE

L1
2

MAIN PCB (CYCLE)


TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

L N there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

MAGNETIC
TB_EXT

X : OFF / O : ON
CONTACTOR
L3

DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

Max mode X
21 22 23 24
BL BR WH BK

L2

Peak Control Peak control : To limit maximum


O
current (Power saving)
TB2 & TB3

default setting X
POWER X
L1

SUPPLY
1Ø 220 ~ 240 V AC
CN_MIX_OUT
N
L

NOTE
RS3
WIFI MODEM
1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.

Power supply of
Main T/B R
CN_WF

POWER S T N the 3 Phase Model


SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #10 SPACE HEATING, COOLING, AND DHW WITH THERMOSTAT REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
A motorized 3-way diverting valve determining flow direction to either space heating or External Pump - O
3 Way Valve (A) DHW tank. OSHA-3V Expansion Tank For IWT, OSHE-12KT (DHW Circuit) O O
Controlled by THERMA V with 230V power. Operating time 3s. Flexible Connection - O
A insulated stainless steel hot water tank with 2.4kW electric heating (230V). Fan Coil Unit - O
Domestic Hot Water Single Coil : OSHW-200F(200L) / 300F(300L) / 500F(500L) Single coil : Flow Sensor - O
Tank OSHW-200F/300F/500F
Double coil : OSHW-300FD(300L) Heat Meter - O
OSHW-200F (Single Coil, 200L)
DHW Tank Temperature OSHW-300F (Single Coil, 300L)
A temperature sensor for DHW tank. Cable length 12m. PHRSTA0 Domestic Hot Water Tank O O
Sensor OSHW-500F (Single Coil, 500L)
OSHW-300FD (Double Coil, 300L)
Thermostatic Mixing A mixing valve that blends hot water with cold water to ensure constant, safe shower OSHA-MV (3/4") Isolation Valve - O
Valve and bath outlet temperatures, preventing scalding. OSHA-MV1 (1") PACEZA000 (AC Ez Touch)
LG Central Controller PACS5A000 (AC Smart 5) O
PACP5A000 (ACP 5)
Magnetic Contactor - O O
Magnetic Filter - O
Meter Interface PENKTH000 O
Mixing Pump - O
Mixing Zone Temperature Sensor PRSTAT5K10 O
3rd party accessories
Mixing Valve - O
Full Name Description PI485 Gateway PMNFP14A1 O
An external water pump that circulates the water inside piping when water circuit is segregated or pump Pressure Gauge - O
External Pump discharge head is insufficient to overcome total system friction loss. Plate Heat Exchanger - O
Controlled by THERMA V with 230V power. Radiator - O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install Recirculation Pump - O
Magnetic Filter
the magnetic filter to protect heat pump system. Remote Room Air Temperature Sensor PQRSTA0 O
Default, PREMTW101 for
A water tank containing certain amount of water that secures the required minimum water volume for the system Standard III Remote Controller O
Buffer Tank 2 Remo control
or stores heat energy which is needed for defrosting and reducing start up load. Solar Pump - O
A motorized isolation valve that blocks the water flow into underfloor coil in order to prevent water condensation Safety Relief Valve - O
2 Way Valve during cooling mode. Strainer - O
Controlled by THERMA V with 230V power. Required operating time : less than 90s. Solar Temperature Sensor (PT-1000) - O
A control device that senses the temperature of a room and performs actions so that the room's temperature is
maintained near a desired setpoint. Service Valve - O
Thermostat
Thermostat must be connected with Therma V, Valve, Pump, and FCU where applicable. Thermostat - O
OSHA-MV
2 Way Valve for Thermostatic Mixing Valve O O
A isolation valve paired with thermostat to allow whether water flows into the water circuit. OSHA-MV1
Thermostat Under Floor Heating Coil - O
Wi-Fi Modem PWFMDD200 O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers. Water Temperature Sensor - O
REFERENCED APPLICATION #10 SPACE HEATING, COOLING, AND DHW WITH THERMOSTAT
ACCESSORIES LG

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating, Cooling, and DHW with Thermostat
Product R32 Monobloc S (New) 3 Way Valve (A) (OSHA-3V)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
UFH(H) + FCU(H&C) A motorized 3-way diverting valve determining flow
Terminal Device
direction to either space heating or DHW tank.
Main Controller Thermostat Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Controlled by THERMA V with 230V power.
Control Setting of LG RS3 Controller Based on Water Temp. Operating time 3s.
External Pump Controlled by Thermostat Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG Domestic Hot Water Tank
(OSHW-200F/300F/500F)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem A insulated stainless steel hot water tank with
2.4kW electric heating (230V).
LG

Single Coil : OSHW-200F(200L) / 300F(300L) /


Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
500F(500L)

Drain Pressure Reducing Valve Drain Pan Cover Plate DHW Tank Sensor (PHRSTA0)
A temperature sensor for DHW tank. Cable length
12m.

Thermostatic Mixing Valve (OSHA-MV,


OSHA-MV1)
A mixing valve that blends hot water with cold
water to ensure constant, safe shower and bath
outlet temperatures, preventing scalding.
SPACE HEATING AREA
COOLING CIRCUIT
RS3
THERMOSTAT 1 THERMOSTAT 2

UFH
DHW TANK FCU

3RD PARTY ACCESSORIES

HOT WATER
External Pump
POWER SUPPLY An external water pump that circulates the water
THERMOSTATIC
inside piping when water circuit is segregated or
MIXING VALVE
(OPTION)
2 WAY VALVE FOR 2 WAY VALVE FOR pump discharge head is insufficient to overcome
THERMOSTAT THERMOSTAT total system friction loss.
(OPTION)
Magnetic Filter (Recommended)
A magnetic filter that collects metallic particle
caused by corrosion or erosion. It is strongly
1Ø 220-240V AC or 3Ø 380-415V AC

DHW TANK recommended to install the magnetic filter to


BUILT IN COMPONENTS SENSOR protect heat pump system.
- Plate Type Heat Ex. CITY WATER SUPPLY
- Water pump
Buffer Tank
- Expansion vessel (8 L)
TB1 7 / 8 / 9
CN_REMO

- Safety valve (3 bar) A water tank containing certain amount of water


CN_TH4

3 WAY DN25 that secures the required minimum water volume


- Pressure sensor POWER
VALVE (A) SUPPLY
- Strainer (30 mesh) for the system or stores heat energy which is
- Flow sensor DN25 needed for defrosting and reducing start up load.

2 Way Valve
TB2 21 / 22 / 23 / 24 A motorized isolation valve that blocks the water
LG TB3 25 MAGNETIC 2 WAY flow into underfloor coil in order to prevent water
DN25 VALVE
CONTACTOR condensation during cooling mode.
TB1 4 / 6
THERMA V Controlled by THERMA V with 230V power.
Required operating time : less than 90s.
EXTERNAL PUMP
DN25 Thermostat
DN25 DN25 A control device that senses the temperature of a
DIFFERENTIAL room and performs actions so that the room's
MAKE UP WATER PRESSURE
VALVE temperature is maintained near a desired setpoint.
SERVICE Thermostat must be connected with Therma V,
THERMA V R32 MONOBLOC S VALVE Valve, Pump, and FCU where applicable.

MAGNETIC FILTER 2 Way Valve for Thermostat


BUFFER TANK
(RECOMMENDED) A isolation valve paired with thermostat to allow
whether water flows into the water circuit.

Differential Pressure Valve


A self pressure regulating valve that provides
constant differential pressure between supply and
return headers.

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #10 SPACE HEATING, COOLING, AND DHW WITH THERMOSTAT
DIP SWITCH SETTINGS

WIRING DIAGRAM
DHW TANK HEATING SYSTEM MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
For General Case ON
OFF
3 WAY 1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER
VALVE (A)
SW2

L
L For OSHA-3V ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
2 3 WAY
3 1 2 3 4 5 6 7 8
VALVE (A)
L
6
X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS
2 WAY Communication
Master (Link to LG controller) X

VALVE
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

Antifreeze is not applied X


Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


DHW TANK
L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR SENSOR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
230 V AC / space heating Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
installed
230 V AC / DHW heating Air Sensor
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


2 WAY VALVE
2 WAY

Thermostat Thermostat is not installed X


L1
5

- L : on Voltage when Cooling is active (NO Valve) Installation Thermostat is installed O


CN_ROOM1

- L1 : on Voltage when Cooling is not active (NC Valve) default setting X X X X X X X X


4
L

230 V AC
BR BR BL

N
3
MIXING
VALVE

L1

EXTERNAL
2

PUMP
MAIN PCB (CYCLE)
TB1

1
L

SW1

ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

230 V AC / L3 DHW
TB_EXT

X : OFF / O : ON
L3

DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

230 V AC / L2 Heating Mode DHW Max mode X


21 22 23 24
BL BR WH BK

L2

C H (On/Off)
(C/H) Peak Control Peak control : To limit maximum
O
current (Power saving)
230 V AC / L1 Cooling
TB2 & TB3

default setting X X
L1

CN_MIX_OUT
N

230 V AC MECHANICAL
L

THERMOSTAT
(3rd party)
NOTE
RS3 MAGNETIC
WIFI MODEM
CONTACTOR 1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.
POWER
SUPPLY
Power supply of
Main T/B R
CN_WF

POWER S T N 1Ø 220 ~ 240 V AC


the 3 Phase Model
SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #11 SPACE HEATING AND DHW WITH EXTERNAL BOILER REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
A control device that enables wireless communication with internet router. Expansion Tank For IWT, OSHE-12KT (DHW Circuit)
Wi-Fi Modem PWFMDD200 O O
Including USB cable 0.6m and extension cable 0.5m
Flexible Connection - O
Fan Coil Unit - O
Extension Cable for Cable Length 10m Flow Sensor - O
PWYREW000
Wi-Fi Modem
Heat Meter - O
A motorized 3-way diverting valve determining flow direction to either space heating or OSHW-200F (Single Coil, 200L)
3 Way Valve (A) DHW tank. OSHW-300F (Single Coil, 300L)
OSHA-3V Domestic Hot Water Tank O O
Controlled by THERMA V with 230V power. Operating time 3s. OSHW-500F (Single Coil, 500L)
OSHW-300FD (Double Coil, 300L)
A insulated stainless steel hot water tank with 2.4kW electric heating (230V). Isolation Valve - O
Domestic Hot Water Single coil :
Single Coil : OSHW-200F(200L) / 300F(300L) / 500F(500L) PACEZA000 (AC Ez Touch)
Tank Double coil : OSHW-300FD(300L) OSHW-200F/300F/500F
LG Central Controller PACS5A000 (AC Smart 5) O
PACP5A000 (ACP 5)
DHW Tank Temperature A temperature sensor for DHW tank. Cable length 12m. Magnetic Contactor - O O
PHRSTA0
Sensor
Magnetic Filter - O
Meter Interface PENKTH000 O
Thermostatic Mixing A mixing valve that blends hot water with cold water to ensure constant, safe shower OSHA-MV (3/4") Mixing Pump - O
Valve and bath outlet temperatures, preventing scalding. OSHA-MV1 (1")
Mixing Zone Temperature Sensor PRSTAT5K10 O
Mixing Valve - O
PI485 Gateway PMNFP14A1 O
Pressure Gauge - O
Plate Heat Exchanger - O
3rd party accessories
Radiator - O
Full Name Description Recirculation Pump - O
Remote Room Air Temperature Sensor PQRSTA0 O
An external water pump that circulates the water inside piping when water circuit is segregated or pump Default, PREMTW101 for
External Pump Standard III Remote Controller O
discharge head is insufficient to overcome total system friction loss. 2 Remo control
Solar Pump - O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to
Magnetic Filter Safety Relief Valve - O
install the magnetic filter to protect heat pump system.
Strainer - O
A water tank containing certain amount of water that secures the required minimum water volume for the system Solar Temperature Sensor (PT-1000) - O
Buffer Tank or stores heat energy which is needed for defrosting and reducing start up load.
Service Valve - O
An external boiler supplied by a 3rd party that operates alternatively interlocking with THERMA V. The external Thermostat - O
External Boiler boiler should have a intergrated or dedicated circulation pump. OSHA-MV
Thermostatic Mixing Valve O O
Controlled by THERMA V with voltage free contact switch. OSHA-MV1
Under Floor Heating Coil - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers. Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #11 SPACE HEATING AND DHW WITH EXTERNAL BOILER
ACCESSORIES LG

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & DHW with External Boiler
Product R32 Monobloc S (New) Wi-Fi Modem (PWFMDD200)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
A control device that enables wireless
Terminal Device RAD
communication with internet router.
Main Controller LG RS3 Controller Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Including USB cable 0.6m and extension cable
Control Setting of LG RS3 Controller Based on Air Temp. 0.5m
External Pump Controlled by THERMA V Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG Extension Cable for Wi-Fi Modem
(PWYREW000)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem Cable Length 10m
LG

3 Way Valve (A) (OSHA-3V)


Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
A motorized 3-way diverting valve determining flow
direction to either space heating or DHW tank.
Drain Pressure Reducing Valve Drain Pan Cover Plate Controlled by THERMA V with 230V power.
Operating time 3s.

Domestic Hot Water Tank


(OSHW-200F/300F/500F)
A insulated stainless steel hot water tank with
2.4kW electric heating (230V).
Single Coil : OSHW-200F(200L) / 300F(300L) /
500F(500L)

SPACE HEATING AREA DHW Tank Sensor (PHRSTA0)


RS3 A temperature sensor for DHW tank. Cable length
12m.

Thermostatic Mixing Valve (OSHA-MV,


RAD RAD OSHA-MV1)
DHW TANK
EXTERNAL A mixing valve that blends hot water with cold
BOILER water to ensure constant, safe shower and bath
outlet temperatures, preventing scalding.
HOT WATER

DN25 BUILT IN
POWER SUPPLY
THERMOSTATIC PUMP
MIXING VALVE
(OPTION)
ON/OFF
SIGNAL 3RD PARTY ACCESSORIES

External Pump
1Ø 220-240V AC or 3Ø 380-415V AC

DHW TANK
An external water pump that circulates the water
SENSOR inside piping when water circuit is segregated or
BUILT IN COMPONENTS
TB_EXT_EXT BOILER

- Plate Type Heat Ex. CITY WATER SUPPLY pump discharge head is insufficient to overcome
- Water pump total system friction loss.
- Expansion vessel (8 L) 3 WAY
CN_REMO

- Safety valve (3 bar) VALVE (A) Magnetic Filter (Recommended)


- Pressure sensor A magnetic filter that collects metallic particle
WI-FI POWER
- Strainer (30 mesh)
- Flow sensor
MODEM SUPPLY caused by corrosion or erosion. It is strongly
recommended to install the magnetic filter to
LG
DN25 protect heat pump system.
CN_TH4
MAGNETIC
TB1 7 / 8 / 9
LG CN_WF
CONTACTOR Buffer Tank
TB_EXT_PUMP A2 A water tank containing certain amount of water
DN25
that secures the required minimum water volume
THERMA V
for the system or stores heat energy which is
DIFFERENTIAL
PRESSURE needed for defrosting and reducing start up load.
EXTERNAL PUMP
DN25 VALVE
External Boiler
DN25 DN25
An external boiler supplied by a 3rd party that
MAKE UP WATER operates alternatively interlocking with THERMA V.
The external boiler should have a intergrated or
SERVICE dedicated circulation pump.
THERMA V R32 MONOBLOC S VALVE
Controlled by THERMA V with voltage free contact
switch.
BUFFER TANK
MAGNETIC FILTER
(RECOMMENDED) Differential Pressure Valve
A self pressure regulating valve that provides
constant differential pressure between supply and
return headers.

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #11 SPACE HEATING AND DHW WITH EXTERNAL BOILER
DIP SWITCH SETTINGS

WIRING DIAGRAM
DHW TANK HEATING SYSTEM MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
For General Case ON
OFF
3 WAY 1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER
VALVE (A)
SW2

L
L For OSHA-3V ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
2 3 WAY
3 1 2 3 4 5 6 7 8
VALVE (A)
L
6
X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
Communication
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

Antifreeze is not applied X


Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X
N
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


DHW TANK
L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR SENSOR Control As Slave O
Heat pump installation (Heating or
cooling circuit only) X X
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

Heating only X
230 V AC / space heating Heat Pump Cycle
3 WAY

Heating and cooling O


L1
8

EXTERNAL

CN_ROOM2
Remote Room Remote room air sensor is not
X
230 V AC / DHW heating PUMP Air Sensor installed
(Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

Full capacity is used O O


2 WAY

Thermostat Thermostat is not installed X


L1
5

Installation Thermostat is installed O


CN_ROOM1
default setting X X X X X X X X
4
L
BR BR BL

N
3
MIXING
VALVE

L1
2

MAIN PCB (CYCLE)


TB1

MAGNETIC
1
L

CONTACTOR
SW1

EXTERNAL BOILER ON For 5/7/9 kW models,


RD BK WH
Controller

OFF
25 26 27
3rd Party

L N there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

BUILT IN POWER
TB_EXT

X : OFF / O : ON
SUPPLY
L3

PUMP DIP SW 1 2 3
Always mode : Maintain low noise
1Ø 220 ~ 240 V AC mode for target temperature X
Low Noise Mode
ON/OFF SIGNAL Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

Max mode X
21 22 23 24
BL BR WH BK

L2

Peak Control Peak control : To limit maximum


O
current (Power saving)
TB2 & TB3

default setting X X
L1

CN_MIX_OUT
N
L

NOTE
RS3
WIFI MODEM
1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.

Power supply of
Main T/B R
CN_WF

POWER S T N the 3 Phase Model


SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #12 SPACE HEATING AND DHW WITH BACK-UP HEATER REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
External Pump - O
A control device that enables wireless communication with internet router. Expansion Tank For IWT, OSHE-12KT (DHW Circuit)
Wi-Fi Modem PWFMDD200 O O
Including USB cable 0.6m and extension cable 0.5m
Flexible Connection - O
Fan Coil Unit - O
Extension Cable for Cable Length 10m Flow Sensor - O
PWYREW000
Wi-Fi Modem
Heat Meter - O
A motorized 3-way diverting valve determining flow direction to either space heating or OSHW-200F (Single Coil, 200L)
3 Way Valve (A) DHW tank. OSHW-300F (Single Coil, 300L)
OSHA-3V Domestic Hot Water Tank O O
Controlled by THERMA V with 230V power. Operating time 3s. OSHW-500F (Single Coil, 500L)
OSHW-300FD (Double Coil, 300L)
A insulated stainless steel hot water tank with 2.4kW electric heating (230V). Isolation Valve - O
Domestic Hot Water Single coil :
Single Coil : OSHW-200F(200L) / 300F(300L) / 500F(500L) PACEZA000 (AC Ez Touch)
Tank Double coil : OSHW-300FD(300L) OSHW-200F/300F/500F
LG Central Controller PACS5A000 (AC Smart 5) O
PACP5A000 (ACP 5)
DHW Tank Temperature A temperature sensor for DHW tank. Cable length 12m. Magnetic Contactor - O O
PHRSTA0
Sensor
Magnetic Filter - O
Meter Interface PENKTH000 O
Thermostatic Mixing A mixing valve that blends hot water with cold water to ensure constant, safe shower OSHA-MV (3/4") Mixing Pump - O
Valve and bath outlet temperatures, preventing scalding. OSHA-MV1 (1")
Mixing Zone Temperature Sensor PRSTAT5K10 O
Optional for Monobloc Mixing Valve - O
An electric heater for supplementing insufficient capacity in case of extremely low
HA031M.E1 (3kW, 1Ø) PI485 Gateway PMNFP14A1 O
Backup Heater ambient temperature or emergency operation.
HA061M.E1 (6kW, 1Ø) Pressure Gauge - O
Controlled by THERMA V with 230V power.
HA063M.E1 (6kW, 3Ø)
Plate Heat Exchanger - O
Radiator - O
Recirculation Pump - O
3rd party accessories Remote Room Air Temperature Sensor PQRSTA0 O
Description Default, PREMTW101 for
Full Name Standard III Remote Controller O
2 Remo control
An external water pump that circulates the water inside piping when water circuit is segregated or pump Solar Pump - O
External Pump discharge head is insufficient to overcome total system friction loss. Safety Relief Valve - O
Controlled by THERMA V with 230V power.
Strainer - O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to install Solar Temperature Sensor (PT-1000)
Magnetic Filter - O
the magnetic filter to protect heat pump system.
Service Valve - O
A water tank containing certain amount of water that secures the required minimum water volume for the system Thermostat - O
Buffer Tank
or stores heat energy which is needed for defrosting and reducing start up load. OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
Under Floor Heating Coil - O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers.
Wi-Fi Modem PWFMDD200 O
Water Temperature Sensor - O
REFERENCED APPLICATION #12 SPACE HEATING AND DHW WITH BACK-UP HEATER
ACCESSORIES LG

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating & DHW with Back-up Heater
Product R32 Monobloc S (New) Wi-Fi Modem (PWFMDD200)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
A control device that enables wireless
Terminal Device UFH
communication with internet router.
Main Controller LG RS3 Controller Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Including USB cable 0.6m and extension cable
Control Setting of LG RS3 Controller Based on Air Temp. or Water Temp. 0.5m
External Pump Controlled by THERMA V Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG Extension Cable for Wi-Fi Modem
(PWYREW000)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem Cable Length 10m
LG

3 Way Valve (A) (OSHA-3V)


Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
A motorized 3-way diverting valve determining flow
direction to either space heating or DHW tank.
Drain Pressure Reducing Valve Drain Pan Cover Plate Controlled by THERMA V with 230V power.
Operating time 3s.

Domestic Hot Water Tank


(OSHW-200F/300F/500F)
A insulated stainless steel hot water tank with
2.4kW electric heating (230V).
Single Coil : OSHW-200F(200L) / 300F(300L) /
500F(500L)

SPACE HEATING AREA DHW Tank Sensor (PHRSTA0)


RS3 A temperature sensor for DHW tank. Cable length
12m.

Thermostatic Mixing Valve (OSHA-MV,


OSHA-MV1)
DHW TANK UFH UFH
A mixing valve that blends hot water with cold
water to ensure constant, safe shower and bath
outlet temperatures, preventing scalding.
HOT WATER
Back Up Heater (HA031M.E1, HA061M.E1,
POWER SUPPLY HA063M.E1)
THERMOSTATIC An electric heater for supplementing insufficient
MIXING VALVE capacity in case of extremely low ambient
(OPTION) temperature or emergency operation.
Controlled by THERMA V with 230V power.
BACK-UP
HEATER
1Ø 220-240V AC or
3Ø 380-415V AC
1Ø 220-240V AC or 3Ø 380-415V AC

DHW TANK 3RD PARTY ACCESSORIES


BUILT IN COMPONENTS SENSOR
- Plate Type Heat Ex. CITY WATER SUPPLY
- Water pump
- Expansion vessel (8 L) External Pump
TB1 7 / 8 / 9
CN_REMO

- Safety valve (3 bar) 3 WAY An external water pump that circulates the water
CN_TH4

- Pressure sensor VALVE (A) DN25


POWER inside piping when water circuit is segregated or
- Strainer (30 mesh) WI-FI
MODEM DN25 SUPPLY pump discharge head is insufficient to overcome
- Flow sensor
total system friction loss.
LG
MAGNETIC
TB4 31 / 32
CONTACTOR Magnetic Filter (Recommended)
TB_HEAT_CONTACT
LG A magnetic filter that collects metallic particle
CN_WF
DN25 caused by corrosion or erosion. It is strongly
TB_EXT_PUMP A2
recommended to install the magnetic filter to
THERMA V
protect heat pump system.
DIFFERENTIAL
EXTERNAL PUMP PRESSURE
DN25 VALVE Buffer Tank
A water tank containing certain amount of water
DN25 DN25 that secures the required minimum water volume
MAKE UP WATER for the system or stores heat energy which is
needed for defrosting and reducing start up load.
SERVICE
THERMA V R32 MONOBLOC S VALVE Differential Pressure Valve
A self pressure regulating valve that provides
MAGNETIC FILTER constant differential pressure between supply and
BUFFER TANK
(RECOMMENDED)
return headers.

NOTE
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof.
REFERENCED APPLICATION #12 SPACE HEATING AND DHW WITH BACK-UP HEATER
DIP SWITCH SETTINGS

WIRING DIAGRAM
DHW TANK HEATING SYSTEM MAIN PCB (HYDRO)
SW1
MONOBLOC UNIT
For General Case ON
OFF
3 WAY 1 2 3 4 5 6 7 8

10 11 12 13 14 15 16 17 18 19 20
PUMP (C)
BR BL

N
WATER
VALVE (A)
SW2

L
L For OSHA-3V ON
MIX PUMP

BR WH BL BR WH BL BR WH BL BR BL BR BL BR BL

N OFF
2 3 WAY
3 1 2 3 4 5 6 7 8
VALVE (A)
L
6
X : OFF / O : ON
PUMP (B)

N
WATER

DIP SW 1 1 2 3 4 5 6 7 8
MODBUS Master (Link to LG controller) X
Communication
L

Type Slave (Link to 3rd party controller) O

MODBUS REGINE X
Function Unified Open Protocol O
W.TANK
HEATER

Antifreeze is not applied X


Antifreeze Mode Antifreeze is applied (Adjustable
O
anti-freeze temp.)
L

default setting X X X
DHW TANK
N

SENSOR
VALVE (B)

DIP SW 2 1 2 3 4 5 6 7 8
3 WAY

Indoor Unit Type As Master X


L1

Setting for Group

CN_TH4
TB_SENSOR
SOLAR Control As Slave O
BACK UP HEATER (Example - HA061M E1) Heat pump installation (Heating or
X X
cooling circuit only)
DEW Accessory
L

Installation Heat pump + DHW tank are installed X O


Information
AMBIENT POWER SIGNAL SIGNAL TEMP.
Heat pump + DHW tank + Solar
thermal system are installed
O X
N
9
VALVE (A)

SUPPLY STEP A STEP B SENSOR Heating only X


230 V AC / space heating Heat Pump Cycle
3 WAY

Heating and cooling O


- - BR BL BR BL BR BL
L1
8

CN_ROOM2
Remote Room Remote room air sensor is not
X
installed
230 V AC / DHW heating Air Sensor
1(L) 2(N) 3 4 5 6 7 8 (Accessory)
7

Remote room air sensor is installed O


L

Backup heater is not used X X


L N A(A1) A(A2) B(A1) B(A2) A B Selecting Backup
Half capacity is used O X
N
6

Heater Capacity
VALVE (A)

EXTERNAL Full capacity is used O O


2 WAY

PUMP Thermostat Thermostat is not installed X


L1
5

Installation Thermostat is installed O


CN_ROOM1
default setting X X X X X X X X
POWER
4
L

SUPPLY
1Ø 220 ~ 240 V AC
BR BR BL

N
3

TB4 (Accessory)
MIXING
VALVE

L1
2

MAIN PCB (CYCLE)


TB1

E. HEATER

31 32
BK BK
SENSOR
1

B
L

SW1
5 V DC
A

ON For 5/7/9 kW models,


CN_TH3
RD BK WH
Controller

OFF
25 26 27
3rd Party

L N there is no No.6 pin.


B

1 2 3 4 5 6
BOILER PUMP A2
A

MAGNETIC
TB_EXT

X : OFF / O : ON
CONTACTOR
L3

DIP SW 1 2 3
Always mode : Maintain low noise
mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
O
EXT
(Default 230 V AC)

mode for target temperature


THERMOSTAT

Max mode X
21 22 23 24
BL BR WH BK

L2

Peak Control Peak control : To limit maximum


O
current (Power saving)
TB2 & TB3

default setting X
POWER X
L1

SUPPLY
1Ø 220 ~ 240 V AC
CN_MIX_OUT
N

L
N
L

NOTE
RS3
WIFI MODEM
1. The wiring cable size and Circuit breaker selection
CN_REMO
COMMON

HEATER1

HEATER2
3 PHASE

must comply with installation manual and


POWER applicable local regulations.
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
2. Make sure that Earth Leakage Circuit Breaker
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT LG (ELCB) should be installed for power supply line.

Power supply of
Main T/B R
CN_WF

POWER S T N the 3 Phase Model


SUPPLY
3Ø 380 ~ 415 V AC
DWG NO. :
REFERENCED APPLICATION #13 SPACE HEATING, COOLING, AND DHW WITH SOLAR PANEL AND THERMOSTAT
REV. 00 10/09/2021

GENERAL ACCESSORY LIST


Scope of supply
Full Name LG Part No.
LG 3rd party
SYMBOL & LEGENDS 2 Remo Cable PZCWRC2 O
2way Valve - O
3way Valve OSHA-3V O O
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
Air Vent Valve - O
Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Buffer Tank For IWT, OSHB-40KT O O
For 3rd party Back-up Heater,
Back-up Heater Temperature Sensor O
Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact PRSTAT5K10


LG
HA031M E1 (1Ø, 3kW, Monobloc)
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem HA061M E1 (1Ø, 6kW, Monobloc)
LG
Back Up Heater HA063M E1 (3Ø, 6kW, Monobloc) O O
HA061C E1 (1Ø, 6kW, Hydrosplit)
Flexible Connection Shut Off Valve Magnetic Contactor Thermostat
HA063C E1 (3Ø, 6kW, Hydrosplit)
Pressure Reducing Valve Drain Pan Cover Plate
Circuit Breaker - O O
Drain
Check Valve - O
Cover Plate PDC-HK10 O
DHW Booster Heater Integrated with DHW Tank O O
PDRYCB000
Dry Contact O
PDRYCB320
Direct Digital Controller - O
Differential Pressure Valve - O
PHLTA (Hydrosplit, 1Ø Split)
DHW Tank Kit PHLTC (3Ø, Split) O
SCOPE OF SUPPLY FOR REQUIRED ACCESSORIES IN APPLICATION PHLTB (Monobloc)
DHW Tank Temperature Sensor PHRSTA0, included in DHW Tank Kit O
LG supplied accessories Drain Pan PHDPC O
Drain Valve - O
Full Name Description Part No. External Boiler - O
A wired remote controller with built-in temperature sensor. Energy Meter - O
RS3 wired remote Monobloc : supplied with 10m length cable, extendable up to max. 50m using Supplied as a default Extension Cable for Wi-Fi Modem PWYREW000 O O
controller extension cable (PZCWRC1) Extension Wire for RS3 Controller PZCWRC1 O
A motorized 3-way diverting valve determining flow direction to either space heating or External Pump - O
3 Way Valve (A) DHW tank. OSHA-3V Expansion Tank For IWT, OSHE-12KT (DHW Circuit) O O
Controlled by THERMA V with 230V power. Operating time 3s. Flexible Connection - O
A insulated stainless steel hot water tank with 2.4kW electric heating (230V). Fan Coil Unit - O
Domestic Hot Water Single Coil : OSHW-200F(200L) / 300F(300L) / 500F(500L) Double coil : Flow Sensor - O
Tank OSHW-300FD
Double coil : OSHW-300FD(300L) Heat Meter - O
DHW Tank Temperature OSHW-200F (Single Coil, 200L)
A temperature sensor for DHW tank. Cable length 12m. PHRSTA0 OSHW-300F (Single Coil, 300L)
Sensor Domestic Hot Water Tank O O
OSHW-500F (Single Coil, 500L)
Thermostatic Mixing A mixing valve that blends hot water with cold water to ensure constant, safe shower OSHA-MV (3/4") OSHW-300FD (Double Coil, 300L)
Valve and bath outlet temperatures, preventing scalding. OSHA-MV1 (1")
Isolation Valve - O
PACEZA000 (AC Ez Touch)
LG Central Controller PACS5A000 (AC Smart 5) O
3rd party accessories PACP5A000 (ACP 5)
Magnetic Contactor - O O
Full Name Description Magnetic Filter - O
An external water pump that circulates the water inside piping when water circuit is segregated or pump Meter Interface PENKTH000 O
External Pump discharge head is insufficient to overcome total system friction loss. Mixing Pump - O
Controlled by THERMA V with 230V power. Mixing Zone Temperature Sensor PRSTAT5K10 O
A magnetic filter that collects metallic particle caused by corrosion or erosion. It is strongly recommended to Mixing Valve - O
Magnetic Filter
install the magnetic filter to protect heat pump system. PI485 Gateway PMNFP14A1 O
Pressure Gauge - O
A water tank containing certain amount of water that secures the required minimum water volume for the system
Buffer Tank Plate Heat Exchanger - O
or stores heat energy which is needed for defrosting and reducing start up load.
Radiator - O
A motorized isolation valve that blocks the water flow into underfloor coil in order to prevent water condensation
Recirculation Pump - O
2 Way Valve during cooling mode.
Controlled by THERMA V with 230V power. Required operating time : less than 90s. Remote Room Air Temperature Sensor PQRSTA0 O
An external water pump that circulates the water inside solar thermal system. Default, PREMTW101 for
Solar Pump Standard III Remote Controller O
Controlled by THERMA V with 230V power. 2 Remo control
Solar Pump - O
Solar Temperature Sensor A temperature sensor (PT-1000) for solar thermal system. Safety Relief Valve - O
A motorized 3-way diverting valve determining flow direction to either DHW tank or bypass (recirculation). Strainer - O
3 Way Valve (B) Controlled by THERMA V with 230V power. Solar Temperature Sensor (PT-1000) - O
Required operating time : less than 90s.
Service Valve - O
A control device that senses the temperature of a room and performs actions so that the room's temperature is
Thermostat - O
Thermostat maintained near a desired setpoint.
Thermostat must be connected with Therma V, Valve, Pump, and FCU where applicable. OSHA-MV
Thermostatic Mixing Valve O O
OSHA-MV1
2 Way Valve for
A isolation valve paired with thermostat to allow whether water flows into the water circuit. Under Floor Heating Coil - O
Thermostat
Wi-Fi Modem PWFMDD200 O
Differential Pressure Valve A self pressure regulating valve that provides constant differential pressure between supply and return headers.
Water Temperature Sensor - O
REFERENCED APPLICATION #13 SPACE HEATING, COOLING, AND DHW WITH SOLAR PANEL AND THERMOSTAT
ACCESSORIES LG

HYDRONIC DIAGRAM RS3 Controller (Default)


A wired remote controller with built-in temperature
sensor.
Monobloc : supplied with 10m length cable,
SYSTEM SUMMARY SYMBOL & LEGENDS extendable up to max. 50m using extension cable
(PZCWRC1)
Application Space Heating, Cooling, and DHW with Solar Panel and Thermostat
Product R32 Monobloc S (New) 3 Way Valve (A) (OSHA-3V)
Circulation Pump Motorized 3 Way Valve Check Valve RS3 Remote Controller
UFH(H) + FCU(H&C) A motorized 3-way diverting valve determining flow
Terminal Device
direction to either space heating or DHW tank.
Main Controller Thermostat Expansion Tank Motorized 2 Way Valve Safety Relief Valve with drain Remote Room Air Sensor Controlled by THERMA V with 230V power.
Control Setting of LG RS3 Controller Based on Water Temp. Operating time 3s.
External Pump Controlled by Thermostat Air Vent Differential Pressure Valve Y-type strainer
D ry C on tact

Dry Contact
LG Domestic Hot Water Tank (OSHW-300FD)
A insulated stainless steel hot water tank with
Pressure Gauge Thermostatic Mixing Valve Flow Sensor Wi-Fi Modem 2.4kW electric heating (230V).
Double coil : OSHW-300FD(300L)
LG

Flexible Connection Shut Off Valve Magnetic Contactor Thermostat


DHW Tank Sensor (PHRSTA0)
A temperature sensor for DHW tank. Cable length
Drain Pressure Reducing Valve Drain Pan Cover Plate 12m.
SOLAR THERMAL COLLECTOR SOLAR TEMP.
SENSOR
Thermostatic Mixing Valve (OSHA-MV,
OSHA-MV1)
A mixing valve that blends hot water with cold
water to ensure constant, safe shower and bath
outlet temperatures, preventing scalding.

SPACE HEATING AREA

COOLING CIRCUIT

THERMOSTAT 1 THERMOSTAT 2
3RD PARTY ACCESSORIES
SOLAR
UFH
PUMP FCU
DHW TANK
External Pump
An external water pump that circulates the water
3 WAY inside piping when water circuit is segregated or
VALVE (B) pump discharge head is insufficient to overcome
HOT WATER total system friction loss.
POWER SUPPLY
THERMOSTATIC Magnetic Filter (Recommended)
MIXING VALVE 2 WAY VALVE FOR 2 WAY VALVE FOR A magnetic filter that collects metallic particle
RS3 DHW TANK THERMOSTAT THERMOSTAT caused by corrosion or erosion. It is strongly
SENSOR (OPTION)
recommended to install the magnetic filter to
protect heat pump system.

Buffer Tank
1Ø 220-240V AC or 3Ø 380-415V AC

A water tank containing certain amount of water


BUILT IN COMPONENTS that secures the required minimum water volume
TB_SENSOR_SOLAR

- Plate Type Heat Ex. for the system or stores heat energy which is
CITY WATER SUPPLY
- Water pump
TB1 10 / 11 / 12

needed for defrosting and reducing start up load.


- Expansion vessel (8 L)
TB1 15 / 16

- Safety valve (3 bar) 3 WAY


- Pressure sensor DN25 POWER 2 Way Valve
VALVE (A)
- Strainer (30 mesh) SUPPLY A motorized isolation valve that blocks the water
- Flow sensor flow into underfloor coil in order to prevent water
condensation during cooling mode.
CN_REMO Controlled by THERMA V with 230V power.
DN25
CN_TH4 Required operating time : less than 90s.
LG TB2 21 / 22 / 23 / 24 MAGNETIC 2 WAY
TB3 25 CONTACTOR VALVE
TB1 7 / 8 / 9 DN25 Solar Pump
THERMA V TB1 4 / 6 An external water pump that circulates the water
inside solar thermal system.
EXTERNAL PUMP Controlled by THERMA V with 230V power.
DN25
DN25 DN25 Solar Temperature Sensor (PT-1000)
DIFFERENTIAL A temperature sensor for solar thermal system.
MAKE UP WATER PRESSURE
VALVE
SERVICE 3 Way Valve (B)
THERMA V R32 MONOBLOC S VALVE A motorized 3-way diverting valve determining flow
direction to either DHW tank or bypass
MAGNETIC FILTER BUFFER TANK (recirculation). Controlled by THERMA V with 230V
(RECOMMENDED) power.
Required operating time : less than 90s.

Thermostat
A control device that senses the temperature of a
room and performs actions so that the room's
temperature is maintained near a desired setpoint.
Thermostat must be connected with Therma V,
NOTE Valve, Pump, and FCU where applicable.
1. This diagram should be used only for reference purpose. It does not contain all the required equipment and safety components in accordance with actual site conditions. Furthermore, please make sure to take into account the applicable standards and
2 Way Valve for Thermostat
laws for each country. LG Electronics disclaims any direct or indirect responsibility for any consequences arising out of any inaccuracies or consequential changes to this general scheme.
A isolation valve paired with thermostat to allow
2. It is essential to ensure the minimum amount of water contained in the heating or cooling system. whether water flows into the water circuit.
3. Must fit the insulations on the entire water piping including valves and connections. If necessary, electrical heat tracing system can be installed or the heating system can also be filled with antifreeze (glycol) to prevent any frost damage.
4. In a cold climate region, water drainage from outdoor unit must be frost-proof. Differential Pressure Valve
A self pressure regulating valve that provides
constant differential pressure between supply and
return headers.
REFERENCED APPLICATION #13 SPACE HEATING, COOLING, AND DHW WITH SOLAR PANEL AND THERMOSTAT
DIP SWITCH SETTINGS

WIRING DIAGRAM
MAIN PCB (HYDRO)
SOLAR THERMAL SYSTEM
SW1

ON
OFF
SOLAR
1 2 3 4 5 6 7 8
PUMP
MONOBLOC UNIT
SW2

ON
3 WAY OFF
PUMP (C)

10 11 12 13 14 15 16 17 18 19 20
BR BL BR BL BR BL

N
WATER

VALVE (B) 1 2 3 4 5 6 7 8
L

X : OFF / O : ON
MIX PUMP

DIP SW 1 1 2 3 4 5 6 7 8
N

MODBUS Master (Link to LG controller) X


Communication
SOLAR TEMP. DHW TANK HEATING SYSTEM Type Slave (Link to 3rd party controller) O
L

SENSOR MODBUS REGINE X


Function Unified Open Protocol O
PUMP (B)

For General Case


N
WATER

Antifreeze is not applied X


Antifreeze Mode Antifreeze is applied (Adjustable
230 V AC 3 WAY anti-freeze temp.)
O
L

VALVE (A) default setting X X X

TB_SENSOR
SOLAR
BR WH BL BR WH BL BR BL
W.TANK

DIP SW 2 1 2 3 4 5 6 7 8
HEATER

DEW L
For OSHA-3V Indoor Unit Type As Master X
Setting for Group
AMBIENT Control As Slave O
L

2 3 WAY Heat pump installation (Heating or


3 X X
6 VALVE (A) Accessory
cooling circuit only)
N

Installation Heat pump + DHW tank are installed X O


VALVE (B)

Information Heat pump + DHW tank + Solar


230 V AC / DHW heating with solar thermal system O X
3 WAY

thermal system are installed


L1

CN_TH4
Heating only X
Heat Pump Cycle
Heating and cooling O
230 V AC / bypass (recirculation)
Remote Room Remote room air sensor is not
L

X
Air Sensor installed
DHW TANK (Accessory) Remote room air sensor is installed O
SENSOR
9
N

Backup heater is not used X X


VALVE (A)

Selecting Backup
230 V AC / space heating Half capacity is used
3 WAY

O X
Heater Capacity
L1
8

Full capacity is used O O

230 V AC / DHW heating CN_ROOM2 Thermostat Thermostat is not installed X


Installation Thermostat is installed O
7
L

default setting X X X X X X X X
BR BR BL BR WH BL

N
6
VALVE (A)

2 WAY VALVE 2 WAY


2 WAY

L1

VALVE
5

- L : on Voltage when Cooling is active (NO Valve)


CN_ROOM1

- L1 : on Voltage when Cooling is not active (NC Valve)


4
L

230 V AC MAIN PCB (CYCLE)


N
3

SW1
MIXING
VALVE

L1

EXTERNAL ON
2

For 5/7/9 kW models,


PUMP
OFF there is no No.6 pin.
TB1

1 2 3 4 5 6
1
L

X : OFF / O : ON
DIP SW 1 2 3
RD BK WH
Controller

25 26 27
3rd Party

Always mode : Maintain low noise


mode for target temperature X
Low Noise Mode
Partial mode : Escape low noise
BOILER PUMP A2

O
A

mode for target temperature


Max mode X
230 V AC / L3 DHW
TB_EXT

Peak Control Peak control : To limit maximum


L3

O
current (Power saving)
default setting X X
EXT
(Default 230 V AC)
THERMOSTAT

230 V AC / L2 Heating Mode DHW


21 22 23 24
BL BR WH BK

L2

C H (On/Off)
(C/H)
230 V AC / L1 Cooling
TB2 & TB3

L1

NOTE
CN_MIX_OUT
N

230 V AC MECHANICAL
1. The wiring cable size and Circuit breaker selection
L

THERMOSTAT
(3rd party) must comply with installation manual and
applicable local regulations.
RS3 MAGNETIC
CONTACTOR 2. Make sure that Earth Leakage Circuit Breaker
CN_REMO

(ELCB) should be installed for power supply line.


COMMON

HEATER1

HEATER2
3 PHASE

POWER
Power supply of
SUPPLY
Main T/B 1(L) 2(N) the 1 Phase Model
1Ø 220 ~ 240 V AC TB_HEAT_CONTACT
POWER
SUPPLY
Power supply of
Main T/B R
CN_WF

POWER S T N 1Ø 220 ~ 240 V AC


the 3 Phase Model
SUPPLY
3Ø 380 ~ 415 V AC