b= 200 mm
h= 190 mm
tf = 10 mm
tw = 6,5 mm
A= 5380 mm2
I= 36920000 mm4
It = 2043000 mm4
4
Iw = 1,0558E+11 mm
Wef = 388600 mm3
Wpl = 429500 mm3
Gr.= 42,3 kg/ml
E= 210000 N/mm2
G= 81000 N/mm2
fyk = 355 N/mm2
→ for S355
N/mm2
fyd = = 309
l = 8500 mm
→ Evaluation of loads:
• Dead load, Gk = 3,60 kN
• Live load, P1 = 26,40 kN
• Snow load, Sk = 28,08 kN/m2
→ Evaluation of the design loads:
SLCP:1,35*Gk + 1,5*U1 + 0,7*1,5*Sk
1,35*Gk = 4,85 kN/ml
1,5*P1 = 39,60 kN/ml
0,7*1,5*Sk= 29,48 kN/ml
P=Σ= 73,94 kN/ml
Ved = 73,94 kN
Mmax = 60,00 kNm
W nec = Mmax => W nec = 194366,20 mm3 < W ef of the propose section
fyd
VEd
0,23 ≤ 1,0
Vc,Rd
MEd
≤ 1,0
Mb,Rd
χLT,mod * W pl,y * fy
Mb,Rd =
γM1
χLT=1/(φLT+√(φLT -β*λLT,b2)),
2
χLT ≤ 1,0
φLT=0.5*(1+αLT*(λLT,b-λLT,0)+β*λLT,b2)
Lc = 8,5 m
k = 1,0
kw = 1,0
C1 = 1,77
C2 = 0
Mcr = 747,76 kNm
λLT,b = 0,45
λLT,0 = 0,40
β= 0,75
φLT = 0,59
χLT = 0,980 < 1,0
MEd
0,453 < 1,0