You are on page 1of 17

PROYECTO INSTALACION ELECTRICA LICENCIATURA EN ARQUITECTURA

PRESENTO: JOSE ALONSO FLORES BAUTISTA REVISO: ARQ. LULU


MEMORIA DE CALCULO
SALA

ACAVADOS

PISO: GRIS PLATA 36.3%

PLAFON: CREMA PALIDO 70.2%

PARED: BLANCO 85%

LUMINARIA TIPO ANSER -16 W-1200 LUMENES (LM)

EM: SALA = 60 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) = MESA DE SALA = 40 CM

K= 4.90 x 6.05 / (2.20) (4.90 + 6.05) = 1.23 = 1 ALTURA DE MESA A TECHO = 2.20 CM

Coeficiente de utilización = 0.6

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 60 lux X 4.90 X 6.05 / 0.6 X 0.85 = 3487.64 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 3487.64 lúmenes / 1 X 1200 lúmenes = 2.90 = 3 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 3 lamp. * 1 * 1200 LM * 0.60 * 0.85 / 4.90 x 6.05 = 61.93 LUX > 60 LUX
ESCALERAS

ACAVADOS

PISO: MADERA 30%

PLAFON: CREMA PALIDO 70.2%

PARED: LADRILLO AMARILLO 45%

LUMINARIA TIPO ADHIL -12 W- 800 LUMENES (LM)

EM: ESCALERAS = 60 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) =

K= 2.15 x 2.60 / (5.20) (2.15 + 2.60) = 0.22 = 1

Coeficiente de utilización = 0.58

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 60 lux X 2.15 x 2.60 / 0.58 X 0.85 = 680.32 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 680.32 lúmenes / 1 X 800 lúmenes = 0.85 = 1 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 1 lamp. * 1 * 800 LM * 0.58 * 0.85 / 2.15 x 2.60 = 70.55 LUX > 60 LUX
BAÑO

ACAVADOS

PISO: AZULEJOS BLANCOS 70%

PLAFON: AZULEJOS BLANCOS 70%

PARED: AZULEJOS BLANCOS 70%

LUMINARIA NASAHIRA ll -15 W-1200 LUMENES (LM)

EM: BAÑO = 200 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) = LAVABO = 85 CM

K= 2.90 x 1.07 / (0.95) (2.90 + 1.07) = 0.82 = 1 ALTURA DE LAVABO A TECHO = 95 CM

Coeficiente de utilización = 0.6

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 200 lux X 2.90 x 1.07 / 0.6 X 0.85 = 1216.86 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 1216.86 lúmenes / 1 X 1200 lúmenes = 1.01 = 2 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 2 lamp. * 1 * 1200 LM * 0.6 * 0.85 / 2.90 x 1.07 = 394.45 LUX > 200 LUX
COMEDOR

ACAVADOS

PISO: AZULEJOS BLANCOS 70%

PLAFON: BLANCO NIEVE 76%

PARED: VERDE CLARO 54%

LUMINARIA TIPO NOVA -11 W-800 LUMENES (LM)

EM: COMEDOR = 60 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) = MESA DE COMEDOR = 75 CM

K= 4.50 x 3.90 / (1.85) (4.50 + 3.90) = 1.12 = 1 ALTURA DE MESA A TECHO = 1.85CM

Coeficiente de utilización = 0.6

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 60 lux X 4.50 x 3.90 / 0.6 X 0.85 = 2064.70 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 2064.70 lúmenes / 1 X 800 lúmenes = 2.58 = 3 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 3 lamp. * 1 * 800 LM * 0.60 * 0.85 / 4.50 x 3.90 = 69.74 LUX > 60 LUX
COCINA

ACAVADOS

PISO: AZULEJOS BLANCOS 70%

PLAFON: NARANJA 25.4%

PARED: AZULEJOS BLANCOS 70%

LUMINARIA TIPO ANKAA lll -18 W-1300 LUMENES (LM)

EM: COCINA = 200 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) = BARRA = 1.10 CM

K= 4.50 x 2.65 / (1.50) (4.50 + 2.65) = 1.11 = 1 ALTURA DE BARRA A TECHO = 1.50 CM

Coeficiente de utilización = 0.6

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 200 lux X 4.50 x 2.65 / 0.6 X 0.70 = 5678.57 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 5678.57 lúmenes / 1 X 1300 lúmenes = 4.36 = 5 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 5 lamp. * 1 * 1300 LM * 0.60 * 0.70 / 4.50 x 2.65 = 228.93 LUX > 200 LUX
TERRAZA

ACAVADOS

PISO: AZULEJOS BLANCOS 70%

PLAFON: CREMA PALIDO 70.2%

PARED: BLANCO 85%

EM: TERRAZA = 150 LUX LUMINARIA TIPO ANSER -16 W-1200 LUMENES (LM)

 INDICE DE CUARTO

K= a x b / h (a+b) = MESA DE TERRAZA = 80 CM

K= 1.63 x 6.05 / (1.80) (1.63 + 6.05) = 1.71 = 2 ALTURA DE MESA A TECHO = 1.80 CM

Coeficiente de utilización = 0.59

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 150 lux X 1.63 x 6.05 / 0.59 X 0.70 = 3581.65 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 3581.65 lúmenes / 1 X 1200 lúmenes = 2.98 = 3 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 3 lamp. * 1 * 1200 LM * 0.59 * 0.70 / 1.63 x 6.05 = 150.76 LUX > 150 LUX
LAVANDERIA

ACAVADOS

PISO: GRIS ACERO CLARO 31.4%

PLAFON: BLANCO MARFIL 67.0%

PARED: AZULEJOS BLANCOS 70%

LUMINARIA TIPO A19 -14 W-1301 LUMENES (LM)

EM: LAVANDERIA = 200 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) = LAVADERO = 75 CM

K= 2.15 x 1.24 / (1.75) (2.15 + 1.24) = 0.44 = 1 ALTURA DE LAVADERO A TECHO = 1.75 CM

Coeficiente de utilización = 0.6

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 200 lux X 2.15 x 1.24 / 0.6 X 0.70 = 1269.52 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 1269.52 lúmenes / 1 X 1301 lúmenes = 0.97 = 1 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 1 lamp. * 1 * 1301 LM * 0.60 * 0.70 / 2.15 x 1.24 = 204.95 LUX > 200 LUX
BAÑO

ACAVADOS

PISO: AZULEJOS BLANCOS 70%

PLAFON: AZULEJOS BLANCOS 70%

PARED: AZULEJOS BLANCOS 70%

LUMINARIA NASAHIRA ll -15 W-1200 LUMENES (LM)

EM: BAÑO = 200 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) = LAVABO = 85 CM

K= 2.90 x 2.20 / (1.75) (2.90 + 2.20) = 0.71 = 1 ALTURA DE LAVABO A TECHO = 1.75 CM

Coeficiente de utilización = 0.6

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 200 lux X 2.90 x 2.20 / 0.6 X 0.85 = 2501.96 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 2501.96 lúmenes / 1 X 1200 lúmenes = 2.08 = 3 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 3 lamp. * 1 * 1200 LM * 0.6 * 0.85 / 2.90 x 2.20 = 287.77 LUX > 200 LUX
PASILLO

ACAVADOS

PISO: MADERA 30%

PLAFON: CREMA PALIDO 70.2%

PARED: LADRILLO AMARILLO 45%

LUMINARIA TIPO ANSER -16 W-1200 LUMENES (LM)


EM: PASILLO = 60 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) =

K= 1.60 x 2.15 / (2.60) (1.60 + 2.15) = 0.35 = 1

Coeficiente de utilización = 0.58

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 60 lux X 1.60 x 2.15 / 0.58 X 0.85 = 418.66 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 418.66 lúmenes / 1 X 1200 lúmenes = 0.34 = 1 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 1 lamp. * 1 * 1200 LM * 0.58 * 0.85 / 1.60 x 2.15 = 171.97 LUX > 60 LUX
ANDADOR

ACAVADOS

PISO: AZULEJOS BLANCOS 70%

PLAFON: BLANCO 85%

PARED: AMARILLO PAJA 65%

EM: ANDADOR = 150 LUX LUMINARIA TIPO COLUMBUS -13 W-1000 LUMENES (LM)

 INDICE DE CUARTO

K= a x b / h (a+b) =

K= 4.50 x 1.15 / (2.60) (4.50 + 1.15) = 0.35 = 1

Coeficiente de utilización = 0.65

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 150 lux X 4.50 x 1.15 / 0.65 X 0.70 = 1706.04 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 1706.04 lúmenes / 1 X 1000 lúmenes = 1.70 = 2 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 2 lamp. * 1 * 1000 LM * 0.65 * 0.70 / 4.50 x 1.15 = 175.84 LUX > 150 LUX
JARDIN

ACAVADOS

PISO: MADERA 30%

PLAFON: CREMA PALIDO 70.2%

PARED: LADRILLO AMARILLO 45%

LUMINARIA TIPO ANSER -16 W-1200 LUMENES (LM)


EM: JARDIN = 60 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) =

K= 1.60 x 2.15 / (2.60) (1.60 + 2.15) = 0.35 = 1

Coeficiente de utilización = 0.58

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 60 lux X 1.60 x 2.15 / 0.58 X 0.85 = 418.66 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 418.66 lúmenes / 1 X 1200 lúmenes = 0.34 = 1 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 1 lamp. * 1 * 1200 LM * 0.58 * 0.85 / 1.60 x 2.15 = 171.97 LUX > 60 LUX
ENTRADA DE LA CASA

ACAVADOS

PISO: MADERA 30%

PLAFON: CREMA PALIDO 70.2%

PARED: LADRILLO AMARILLO 45%

LUMINARIA TIPO ANSER -16 W-1200 LUMENES (LM)


EM: ENTRADA = 60 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) =

K= 1.60 x 2.15 / (2.60) (1.60 + 2.15) = 0.35 = 1

Coeficiente de utilización = 0.58

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 60 lux X 1.60 x 2.15 / 0.58 X 0.85 = 418.66 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 418.66 lúmenes / 1 X 1200 lúmenes = 0.34 = 1 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 1 lamp. * 1 * 1200 LM * 0.58 * 0.85 / 1.60 x 2.15 = 171.97 LUX > 60 LUX
VESTIDOR

ACAVADOS

PISO: AZULEJOS BLANCOS 70%

PLAFON: BLANCO 85%

PARED: VERDE PRADO 39%

LUMINARIA A19 -8.5 W-800 LUMENES (LM)

EM: VESTIDOR = 100 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) =

K= 3.63 x 1.70 / (2.90) (3.63 + 1.70) = 0.39 = 1

Coeficiente de utilización = 0.63

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 100 lux X 3.63 x 1.70 / 0.63 X 0.85 = 1152.38 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 1152.38 lúmenes / 1 X 800 lúmenes = 1.44 = 2 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 2 lamp. * 1 * 800 LM * 0.63 * 0.85 / 3.63 x 1.70 = 138.84 LUX > 100 LUX
RECAMARA PRINCIPAL

ACAVADOS

PISO: AZULEJOS BLANCOS 70%

PLAFON: BLANCO NIEVE 76%

PARED: BLANCO 85%

LUMINARIA -40 W-3600 LUMENES (LM)

EM: RECAMARAS = 300 LUX

 INDICE DE CUARTO

K= a x b / h (a+b) =

K= 3.63 x 4.35 / (2.90) (3.63 + 4.35) = 0.68 = 1

Coeficiente de utilización = 0.6

 FLUJO LUMINOSO TOTAL

0T= EM X S / CU X CM =

0T= 300 lux X 3.63 x 4.35 / 0.6 X 0.85 = 9288. 52 lúmenes

 NUMERO DE LUMINARIAS

NL= 0T / N X 0L =

NL= 9288. 52 lúmenes / 1 X 3,600 lúmenes = 2.58 = 3 lamp.

 COMPROBACION

EM= NL * N * 0L * CM / S =

EM= 3 lamp. * 1 * 3600 LM * 0.6 * 0.85 / 3.63 x 4.35 = 348.81 LUX > 300 LUX