You are on page 1of 9

Submersible Pump

General Data QF

Peformance Range
H H
[feet] [m]
2624 800
60 Hz, SF 1.15
1968 600

1312 400

656 200

328 100

262 80

197 60 QF 125
QF 100

QF 160
QF 210

QF 270

QF 360
QF 1.5

QF 12
QF 20

QF 25

QF 75
QF 30

QF 50
QF 1

QF 2

QF 5

QF 6

131 40

66 20

33 10
1 2 4 6 8 9 10 20 40 60 80 100 200 400
Q [m³/h]

1 2 3 4 6 8 10 20 40 60 80 100
Q [l/s]

2
Submersible Pump
General Data QF

Applications Curve Conditions


The pumps are suitable for the following applications : The conditions below apply to the curves shown on the
following pages :

n Raw water supply


General
n Irrigation systems
l Curve tolerance according to ISO 9906, Annex A.
n Groundwater lowering
l The performance curves show pump performance at
n Pressure boosting actual speed cf. standard motor range.
n Industrial applications The speed of the motors is approximately :
4" motors : n=3460 min-1
Type Key 6" motors : n=3450 min-1
Example
8" to 12" motors : n=3500 min-1
QF 210 - 5 - A B l The measurements were made with airless water at a
temperature of 200c.The curves apply to a kinematic
Type range viscosity of 1mm2/s. When pumping liquids with a
Nominal flow rate x 10 lpm density higher than that of water, motors with
correspondingly higher outputs must be used.
Number of impellers
l The bold curves indicate the recommended
First impeller with reduced diameter (A,B or C) performance range.
l The performance curves are inclusive of possible losses
Second impeller with reduced diameter (A,B or C) such as non-return valve loss.

QF1, QF1.5, QF2, QF5, QF6, QF12, QF20, QF25 Curve


Pumped Liquids
Clean, thin, non-aggressive liquids without solid l Q/H : The curves are inclusive of valve and inlet losses
particles or fibres. at the actual speed.
l Power Curve : BPkW/Stage shows pump power input
Operating Conditions per stage.
Flow rate, Q : 0.1 - 335 m3/h. l Efficiency Curve : Efficiency shows pump stage
Head, H: Maximum 810m. efficiency.

QF30,QF50,QF75,QF100,QF125,QF160,
Maximum Liquid Temperature:
QF210,QF270,QF360 Curve
Installation

Motor Flow velocity- Vertical Horizontal l Q/H : The curves are inclusive of valve and inlet losses
past motor at the actual speed.
Shakti 0.15 m/s 400c 400c Operation without non-return valve will increase the
4", 6" & 8" actual head at nominal performance by 0.5 to 1.0 m.
l NPSH The curve is inclusive of suction case and shows
Operating pressure: Maximum 810m (81 bar)
required inlet pressure.
l Power Curve: It shows pump power input at the actual
speed for each individual pump size.
l Efficiency Curve : Efficiency shows pump stage
efficiency.

3
Submersible Pumps
General Data QF

Pump Range
Type QF 1 QF 1.5 QF 2 QF 5 QF 6 QF 12 QF 20 QF 25 QF 30 QF 50 QF 75 QF 100 QF 125 QF 160 QF 210 QF 270 QF 360

Steel : AISI SS 304 + + + + + + + + + + + + + + + + +

Connection : 11/4 1 11/4 11/4 11/2 2 2 2 21/2 3 3 3 5 5 6 6 6


Rp (Inches) BSP Thread 4 4
11/4 1 11/4 11/4 11/2 2 2 2 3 3 3 3 5 5 6 6 6
NPT Thread
4 4
Flange Connection 5" 5" 6" 6" 6"

Motor Range
0.25
0.37
0.55

0.75

18.5

132
147

185
190
170

220
1.1
1.5

3.0
3.7
4.0
5.5
7.5
2.2

9.2

110
13
15

26
30
37
45

63
75
92
22

55
11

MotorOutput[kW]

Single Phase + + + + + + +

Three Phase + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +

Rewindable motor + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +

Steel : AISI 304 + + + + + + + + + + + + + + + + + + + + + + +

Steel : AISI 304 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +


And Cast Iron

Direct - on - Line starting is recommended up to 75 kW.


Soft starter or autotransformer is recommended above 75 kW.
Motors with star / delta are available from 4.0 kW.

4
Submersible Pump
Submersible Pumps QF

Features and Benefits

A Wide Pump Range 60 Hz


We offers submersible pumps with energy- efficient duty
points ranging from 0.1 to 335 m3/h. The pump range
consists of many pump sizes - and each pump size is
available with an optional number of stages to match any

QF360
duty point.

QF210

QF270
QF100
QF125
QF160
QF50
QF75
High Pumps Efficiency

QF30
QF25
QF12
QF20
QF6
Often pump efficiency is a neglected factor compared to

QF5
the price however, the observant user will notice that

QF2
QF1.5
price variations are without importance to water supply
QF1
economics compared to the importance of pump and
motor efficiencies.
Example:
When pumping 125 m3/h with a head of 200m for a period
of 10 years $ 60,000 will be saved if a pumps and motors
having a 10% higher efficiency is chosen and the price is
$ 0.10 per kWh.

Applications
We offers a complete range of pumps and motors which
as a standard are made completely of stainless steel
AISI - 304. This provides for good wear resisrance and a
reduced risk of corrosion when pumping ordinary cold
water with a minor content of chloride.

Low Installation Costs


Stainless steel means low weight facilitating the handling
of pumps and resulting in low equipment costs and
reduced installation and service time. In addition pumps
will be as new after service due to the high wear
resistance of stainless steel.

5
Submersible Pump
Submersible Pumps QF

Bearings with Sand Channels

CT 0401 0113003
All bearings are water-Lubricated and have a squared shape
enabling sand particles, If any, to leave the pump together
with the pumped liquid.

CT0401 3247003
Inlet Strainer
The inlet strainer prevents particles over a certain size form
entering the pump.

Non-Return Valve
All pumps are equipped with a reliable non-return valve in
the valve casing preventing back flow in connection with

CT0401 3242003
pump stoppage.
Furthermore , the short closing time of the non-return valve
means that the risk of destructive water hammer is reduced
to a minimum.
The valve casing is designed for optimum hydraulic
properties, to minimize the pressure loss across the valve NRV Flape
and thus contributes to the high efficiency of the pump.
Priming Screw
All QF and QF 30 pumps are fitted with a priming screw.
Consequently, dry running is prevented because the priming CT 0401 0242001

screw will make sure that pump bearings are always


lubricated.
Due to the semi-axial impellers of large QF pumps (except
for QF 30) this priming is automatically provided.
However, it applies to all pump types that if the water table is
lowered to a level below the pump inlet neither pump nor
motor will be protected against dry running.
Stop ring
The stop ring prevents damage to the pump during transport A
CT 0401 S2630002

and in case of up-thrust in connection with start - up.


The stop ring, which is designed as a thrust bearing limits
axial movements of the pump shaft. B
Example : QF 125
The stationary part of the stop ring (A) is secured in the top C
bowl (Upper intermediate chamber).
The rotating part (B) is fitted above the collet [split cone (C)].

6
Submersible Pump
Submersible Pumps QF

Material specification Example : QF 125

Pos. Components Materials Standard N-version


1 Valve casing Stainless steel 304 316
1d O-ring NBR
2 valve cup Stainless Steel 304 316
3 Valve seat Stainless Steel 304 316
3a Lower valve Stainless Steel 304 316 1

seat retainer 70
3b Upper valve Stainless Steel 304 316
39
seat retainer
2
4 Top chamber Stainless Steel 304 316
6 Upper bearing Stainless Steel NBR 304 316 3b

7 Necking NBR / PPS 3

8 Bearing NBR 1d
3a
8a Washer Cabron/graphite
6
for stop ring HY 22 in PTFE mass
8a
8b 4
8b Stop ring Stainless Steel 316 316
11c
9 chamber Stainless Steel 304 316
11 split cone nut Stainless Steel 304 316 7
11c Nut for stop ring Stainless Steel 316 316
8 9
12 Split cone Stainless Steel 304 316
13 Impeller Stainless Steel 304 316
14 Suction Stainless Steel 304 316
Interconnector 13
72
15 Strainer Stainless Steel 304 316
7
16 Shaft complete Stainless Steel 431 316
8 9
17 Strap Stainless Steel 304 316
18 Cabel guard Stainless Steel 304 316 16
11

19 Nut for strap Stainless Steel 304 316 7


12
39 Spring for Stainless Steel 304 316
valve cup
70 Valve guide Stainless Steel 304 316 18
17
71 Washer Stainless Steel 316 316
15
72 Wear ring Stainless Steel 304 316 71
14
19
NOTE :

BEARING
- Replaceable wear ring, bearing and neck ring for easy
maintenance.
- Sealed top bearing for high resistance against sand.
- Octagonal shape bearings with sand flush channels to
reduce abrasive wear.

CHECK VALVE & STRAINER


- Standard built-in stop ring to prevent upthrust damage during critical
start up and stopping phase.
- Capable to handle sand content from 50 to 150 mm on certain pump
size.

7
Submersible Pump
Performance Curve QF2

[ft] [m]
1800
SP 2 M3 (QF2)
520 60 Hz, SF 1.15
-58
ISO 9906 Annex A
1600
480

440
1400 -48

400

1200
360

320
1000 -34
Head

280

800 240 -27

200
600 -21

160

-15
400 120
-12

80 -9

200 -6
40

0 0

[hp] [kW]
0.16 0.12
Power

0.08 BPkW / STAGE


0.08
0.04

0.00 0.00
DOC-SPL-0401-QF260 002

[%]
60
Efficiency
Efficiency

40

20

0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]

FLOW RATE

18
Submersible Pump
Technical Data QF2

Motor Dimensions [mm]


101 Net weight
B A [kg]
Rp 1 1/4 Pump type Power
Type C 3x220V 3x220V 3x220V
[kW]
1x220V 3x380V 1x220V 3x380V 1x220V 3x380V
3x460V 3x460V 3x460V
QF2-6 MS 100 0.25 281 256 537 10
QF2-6 MS 100 0.37 281 226 507 9
QF2-9 MS 100 0.37 344 276 226 620 570 12 9
C

QF2-12 MS 100 0.55 407 291 241 698 648 13 11


QF2-15 MS 100 0.75 470 306 276 776 746 14 13
QF2-21 MS 100 1.1 569 346 306 942 902 17 15
A

QF2-27 MS 100 1.5 722 346 1068 18


QF2-34 MS 101 2.2 914 453 1367 30
QF2-48 MS 101 4.0 1208 573 1781 39
95 QF2-58 MS 101 4.0 1597 573 2170 50
B

101 mm = Maximum diameter of


pump inclusive of cable guard &
motor.
QF2-58 are mounted in sleeve for
R11/4 connection and with max.
diameter 108 mm.

19

You might also like