You are on page 1of 4

Sylodyn® NE

Data Sheet

Material closed-cell PU elastomer Standard Sylodyn® range


(polyurethane) Static range of use
Colour blue

Standard delivery dimension


Thickness: 12.5 mm / 25 mm
Roll: 1.5 m wide, 5.0 m long
NF
Strip: up to 1.5 m wide, up to 5.0 m long
Other dimensions, punched and molded parts on request.
0.75 N/mm2
NE

Range of use Compressive load Deformation ND

shape factor-dependent, values apply


to shape factor q = 3
NC
Static range of use up to 0.75 N/mm2 approx. 11 %
(static loads)

Dynamic range of use NB


up to 1.20 N/mm2 approx. 17 %
(static plus dynamic loads)

Load peaks up to 6.0 N/mm2 approx. 40 %


(occasional, brief loads)

10 1 0.1 0.01 0.001


Specific load in N/mm2

Material properties Test methods Comment


Mechanical loss factor 0.08 DIN 53513 1 temperature-, frequency-, specific load- and amplitude-dependent

Rebound resilience 70 % EN ISO 8307 1

Compression hardness 3 0.71 N/mm2 EN ISO 844 1 at 10 % linear compression, 3rd load cycle
2 1
Compression set <5% EN ISO 1856 50 % deformation, 23 °C, 72 h, 30 min after removal of load

Static modulus of elasticity 3


6.69 N/mm 2
at specific load of 0.75 N/mm2

Dynamic modulus of elasticity 3 7.54 N/mm2 DIN 53513 1 at specific load of 0.75 N/mm2, 10 Hz
2 1
Static shear modulus 0.69 N/mm DIN ISO 1827 at a pretension of 0.75 N/mm2

Dynamic shear modulus 1.02 N/mm2 DIN ISO 1827 1 at a pretension of 0.75 N/mm2, 10 Hz
2 1
Min. tensile stress at rupture 3.90 N/mm EN ISO 527-3/5/500

Min. tensile elongation at rupture 300 % EN ISO 527-3/5/500 1

Abrasion 2 ≤ 300 mm3 DIN ISO 4649 1 load 10 N

Coefficient of friction (steel) 0.7 EN ISO 8295 1 dry, static friction

Coefficient of friction (concrete) 0.7 EN ISO 8295 1


dry, static friction

Coefficient of friction (wood) 0.5 EN ISO 8295 1 dry, static friction

Specific volume resistance 10


> 10 Ω · cm EN IEC 62631-3-1 1
dry

Thermal conductivity 0.13 W/(mK) EN 12667

Temperature range -30 °C to 70 °C short term higher temperatures possible


Flammability class E EN ISO 11925-2 normal combustible, EN 13501-1

1
Measurement / evaluation in accordance All information and data is based on our current knowledge. The data can be applied
with the relevant standard for calculations and as guidelines, are subject to typical manufacturing tolerances
2
The measurement is performed on a and are not guaranteed. Material properties as well as their tolerances can vary de-
density-dependent basis with differing pending on type of application or use and are available from Getzner on request.

3
test parameters
Further information can be found in VDI Guideline 2062
www.getzner.com
Values apply to shape factor q = 3
(Association of German Engineers) as well as in glossary.
Further characteristic values on request.

1
Sylodyn ® NE

Load deflection curve


Specific load in N/mm2

1.5
Quasi-static load deflection curve
12.5 mm 25 mm 37.5 mm
measured with a loading rate of
0.075 N/mm2/s.
1.2
50 mm

Testing between flat and plane-paral-


lel steel plates, recording of 3rd load,
0.9
with filtered starting range in accor-

Dynamic range of use


0.75 N/mm2
dance with ISO 844, testing at room
temperature.
0.6
Static range of use
Parameter: thickness of
the Sylodyn® bearing
0.3

Shape factor q = 3

0
0 1 2 3 4 5 6 7 8 9 10
Deflection in mm

Fig. 1: Quasi-static load deflection curve for different bearing thicknesses

Modulus of elasticity

Dynamic range of use


Static range of use
Modulus of elasticity in N/mm2

15

0.75 N/mm2
Quasi-static modulus of elasticity as
tangential modulus from the load
12 deflection curve. Dynamic modulus
of elasticity from sinusoidal excita-
tion with a velocity level of 100 dBv
9 re. 5 · 10-8 m/s corresponding to a
30 Hz
10 Hz
vibration amplitude of 0.22 mm at
10 Hz and 0.08 mm at 30 Hz.
Quasi-static
6

Measurement in accordance with


DIN 53513
3

Parameter: frequency

0 Shape factor q = 3
0 0.3 0.6 0.9 1.2 1.5
Specific load in N/mm2

Fig. 2: Load dependency of the static and dynamic modulus of elasticity

www.getzner.com

2
Natural frequency
Specific load in N/mm2

1.5
Natural frequencies of a vibratory
system with a single degree of free-
dome, consisting of a mass and an
1.2
elastic bearing made of Sylodyn® NE
on a rigid surface.
0.9
Parameter: thickness of

Dynamic range of use


0.75 N/mm2
the Sylodyn® bearing
12.5 mm
0.6
Shape factor q = 3

Static range of use


25 mm
37.5 mm

0.3
50 mm

0
5 10 15 20 25
Natural frequency of the system in Hz

Fig. 3: Natural frequencies for different bearing thicknesses

Vibration isolation efficiency


Disturbing frequency in Hz

100
Reduction of the transmitted me-
90 chanical vibrations by implementa-
-40 dB/99 %
-35 dB/98 % tion of an elastic bearing consist-
80 -30 dB/97 % ing of Sylodyn® NE based on a stiff
-25 dB/94 %
70 subgrade.
-20 dB/90 %
60 Parameter: factor of transmission
-15 dB/82 % in dB, isolation rate in %
50

-10 dB/69 %
40
-5 dB/44 %

30 0 dB/0 %

20

10

0
5 10 15 20 25
Natural frequency of the system in Hz

Fig. 4: Factor of transmission and isolation rate

www.getzner.com

3
Influence of the shape factor
The graphs show the material properties at different shape factors.
Static range of use in N/mm2

Change in deflection
0.90 150 %

120 %
0.75

90 %
0.60

60 %

0.45
30 %

0.30
0%

0.15 -30 %
0.3 1 3 6 0.3 1 3 6
Shape factor Shape factor

Fig. 5: Static range of use in relation to the shape factor Fig. 6: Deflection 4 at constant thickness in relation to
the shape factor
Change in dynamic modulus of elasticity

Change in natural frequencies

20 % 10 %

0% 0%

-20 % -10 %

-40 % -20 %

-60 % -30 %
DB Sylodyn NE en © Copyright by Getzner Werkstoffe GmbH l 03-2022

-80 % -40 %
0.3 1 3 6 0.3 1 3 6
Shape factor Shape factor

Fig. 7: Dynamic modulus of elasticity 4 at 10 Hz in Fig. 8: Natural frequency 4 at constant thickness in


relation to the shape factor relation to the shape factor
We reserve the right to amend the data.

4
Reference values: specific load 0.75 N/mm2, shape factor q = 3

Material properties can be determined using the online calculation program FreqCalc.
The program can be accessed via www.getzner.com (registration necessary).

AUSTRIA — Bürs GERMANY — Berlin — Munich — Stuttgart FRANCE — Paris — Lyon JAPAN — Tokyo INDIA — Pune
JORDAN — Amman CHINA — Beijing USA — Charlotte AUSTRALIA — Melbourne www.getzner.com
4

You might also like