You are on page 1of 1

A B C D E F A B C D E F

15232.09 15232.09
3650.73 3801.52 3798.96 2408.56 1572.31 3650.73 3801.52 3798.96 2408.56 1572.31
C1-CF1 C1-CF2 C1-CF2 C1-CF3 TB (200X350) TB (200X350) TB (200X350) TB (200X350)
1 1 SCHEDULE OF WALL FOOTING

TB (200X350)
1600.53

1600.53
1525.96

1525.96
0)
TB (200X35
TB (200X350) TB (200X350) TB (200X350) TB (200X350) MARK DIMENSION REINFORCING BARS
2 2

TB (200X350)
2100.61

2100.61
WF 250 mm X 400 mm 3-Ø12mm

TB (200X350)

TB (200X350)

TB (200X350)

TB (200X350)
3597.40

3597.40
C2-F2
C1-CF4 C1-CF4
8557.98

8557.98
C1-CF5

0)
TB (200X350) TB (200X350) TB (200X350) TB (200X350)

TB (200X35
3

3439.58
3

3439.58
TB (200X350)
1890.75

1890.75
C2-F7
TB (200X350) TB (200X350) TB (200X350) TB (200X350)
4 4
1469.43

1469.43
C1-CF5
5 5
C1-F1

3650.73 3801.52 3798.96 2408.56 1572.31 3650.73 3801.52 3798.96 2408.56 1572.31
15232.09 15232.09

A B

BAR "Y"
FOUNDATION PLAN TIE BEAM LAYOUT PLAN

1200
W

1500
S-02 SCALE 1:100 S-02 SCALE 1:100

BAR "X"

300
2000

B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350) L TYPICAL SECTION

B3 (200X300)

B3 (200X300)

B3 (200X300)
B3 (200X300)

B3 (200X300)

B3 (200X300)

TYPICAL FOOTING DETAIL


B2 (200X400)

B2 (200X400)

B2 (200X400)

B2 (200X400)

B2 (200X400)

B2 (200X400)

B2 (200X400)
B3 (200X300) B3 (200X300) B3 (200X300) B3 (200X300) B3 (200X300) B3 (200X300)
SCALE: NTS

B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350)

A B C D E F A B C D E F
15232.09 15232.09
3650.73 3801.52 3798.96 2408.56 1572.31 3650.73 3801.52 3798.96 2408.56 1572.31

GB (200X350) GB (200X350) GB (200X350) GB (200X350) B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350)


1 1
GB (200X350)

B1 (200X350)

B1 (200X350)

B1 (200X350)

B1 (200X350)

B1 (200X350)
1600.53

1600.53

1525.96
1525.96
0)

0)
GB (200X35

B1 (200X35
GB (200X350) GB (200X350) GB (200X350) GB (200X350) B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350)
2 2 B3 (200X300)

B3 (200X300)

B3 (200X300)
GB (200X350)

2100.61
2100.61
GB (200X350)

GB (200X350)

GB (200X350)

GB (200X350)

B2 (200X400)

B2 (200X400)

B2 (200X400)

B2 (200X400)

B2 (200X400)
3597.40

3597.40

B3 (200X300) B3 (200X300) B3 (200X300)


B1 (200X350)
8557.98

8557.98
0)

0)
GB (200X350) GB (200X350) GB (200X350) GB (200X350) B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350)
GB (200X35

B1 (200X35
3 3
3439.58

B4 (250X400) B2 (200X400)

B4 (250X400) B2 (200X400)

B4 (250X400) B2 (200X400)

B4 (250X400) B2 (200X400)
GB (200X350)
1890.75

1890.75

TYPICAL WF DETAIL
B2 (200X400)

GB (200X350) GB (200X350) GB (200X350) GB (200X350) B1 (200X350) B1 (200X350) B1 (200X350) B1 (200X350) SCALE: NTS
4 4
1469.43

1469.43

5 5 B1 (200X350) B1 (200X350) B1 (200X350)

3650.73 3801.52 3798.96 2408.56 1572.31 3650.73 3801.52 3798.96 2408.56 1572.31
15232.09 15232.09

C FIRST FLOOR FRAMING PLAN D SECOND FLOOR FRAMING PLAN


S-02 SCALE 1:100 S-02 SCALE 1:100

DESIGNED BY : ARCHITECT/ CIVIL ENGINEER: PROJECT TITLE : OWNER/CLIENT : SHEET CONTENTS : REV. DESCRIPTION DATE : CADD BY : CJDV SHEET NO.

CILHA ENGINEERING SERVICES CHECKED BY : CJDV


ENGINEERS · BUILDERS · DESIGN · CONSULTANCY · LANDSCAPING
ENGR. CARL JOSHUA VILLANUEVA ,RMP
PROPOSED 6 UNITS APARTMENT AS SHOWN*
369 MALIGAYA ST. BRGY PAMPANG,
PRC.NO.: 0178793 VALIDITY: 06/12/2024
CLIENT/CLIENT REPRESENTATIVE
APPROVED BY : S - 02
ANGELES CITY, PAMPANGA, PHILIPPINES 2009 PTR.NO.: AC-1886338 PLACE ISSUED: ANGELES CITY
CONTACT NO: 0977-741-5105 / 0908-943-2621
DATE ISSUED: 01/04/2023 TIN NO.: 621-189-420 DATE : 07/28/2023
EMAIL: jpvillanueva1912@gmail.com / crljsh.villanueva@gmail.com LOCATION : STO. DOMINGO, TARLAC