STAR SAFETY & SECURITY CONSULTANCY Ae Sully (4 GH Liciu'? low CRAWLER CRANE Standard Reference No: BS 7121-24 / BS 7424-23 - Certificate No: S8SCD/23/20083-4 Owner of the Crane: DBB CONTRACTING LLC “Type of Inspection: THOROUGH Date of Inspection: 14-09-2023 NOT Test Report (Reference no 7) Ni Date of Last Inspection; | 12-09-2023 Pressure Test Report (Reference no) | NIL _ Place of Inspection: DUBAI Location ofGrane: PORT DE LAMER, DUBAI, JUMEIRAH _ - ‘Manufactured By: UEBHERR Wire Rope Diameter: | 28 mm Year of Manufacturing: 2016 ‘Number Of Falls: 3/1FALL Model/Type: ___ | Hs8100HD "| Main Hook Capacity; | 32,000 kg Serial Number: 182308 ‘Awsliary Hook Capaciy:| 3,000 kg ‘Owners Identification Mark: CRABB: “Type OF ASLI: DIGITAL LATTICE BOOM Counter Weight: 16400 KG 38.0m “Traffic Plate Number. | F 15710, DUBAI Lifting Height: 39.0m Chassis Number: 182308 Equipment Used For Inspection: | MEASURING TAPE (U5X19648XY), VERNIER CALIPER (2502190592) Length of ib (m) Radius (m) S.W.L (ke) Test Load (ks) Proof load (kg) 38.0 70 11800 = = 38.0 12.0 "10800 = = 38.0 28.0 3300 3400 _ = ‘Maximum Capacity of the Grane at Present condition = © MAX. CAPACITY IS 11800 KG AT 38.0 m JIB LENGTH AT 7.0m RADIUS \s this the fist examination? YES ‘Any part of inspection work has been subcontracted? NIL ‘Was the examination carried out within the Interval of (lickin the box) ‘Months Months Inaccordance of “|_| After the occurrence of exceptional ‘examination scheme ‘lreunstances ‘dentification of any part found to have defect which could become a danger to persons and a description of defect: (none state NONE) NONE Particulars of test carried out as part of the examination: THOROUGH EXAMINATION _ “Any Recommendation from lst report NIL : Reviewed any Documentations with reference: LOAD CHART, PREVIOUS CERTIFICATE Test Result: SAFE TO USE "|Next inspection Due on: 13-09-2024 Work Order Nos SSSCD-W/ia082033/21559 es {The Cnt Viy cme thee ta 25 sharon / tooth espana wich cs mut 2 The irapeton atexing res and sale seo Eamets wen bch fan Inspection Engineer UPRRAPBSIEP inspect Dubai, Sheikh Zayed Road, Email Address: nfo@starsafetyuae.com Email Address: Certificate No. $$SCD/23/29083-1 Vistal inspection for (corrosion, metal flaking, holes, torn, bend, - craéts, distortion wear , other damage) IW) Secon fanaa ‘N| Seon Temaia 1 | Catalogue & Manufacturer Detae s 2i_| crawer Condon 5 | 2 | maintenance/ inspection Records s 22 | erakes 5 3 | Approved Modeation Records NIL 23_| Ani Two Block Device ~ 5 | fase tacture/ Access wars 5 24 | wire Rope Condon 5 [5 | Rotating Upper suuctre s 25_| wire Rope & Termination s 6 | eecualsynem s 26 | coumer Weight fame s 7 | frau Sytem 5 27-_| mit Switches) Protection s & | Hook Bick Main s 28 | Safe Lad indicator s 2 | Wook oc asa, s 29 | Fy aL 10 | Capocty & Weight Marking s 30 | Operators Manual & Load Chart | os 22 satey ate ome s 31 | Operator competency s 12. | Sheaves s 32 | Operators Contos s 13 | Main Hott winch 3 33 | Aus 3 6 | Airy Hot winch s 34 | Reverse Alem s 35 | evetindator s 35 | aatery s 16 | crower s 36. | Fre extinguisher s 7_| eo0m 3 37 | Wowseening - s 18 | newinsatation crise of conformity NL 38 | Majormaintenancefoverhauing/ Aeration. iL 19 | wor-mo1 appcatie) 39 | safety instruction s 20 | moo tening | 40 | sn sate Aras Usaysatepreraton s F=Finding CFaCritical Finding ‘A. Finding B._Critical Finding Finding Details / Target Dat NIL Work Order No: SSScD-W/14092023/21259 | certty on behalf ofthe Third Party Company named above that the tem described herein was Thoroughly Examined by mize being @ Competent Person genet ory me ha hn se mening ane en Se (a) Inspegted by a ( hs dH aN es Inspection Engineer Date Issued: Stamp (Decoment No. W706 Grane (Cawer) [evi Wo, [ii [sue No, [05 [Tesue Date | 08 May 2025]

You might also like