DATA SHEET

Model G15-20A
Gravimetric Method Water Meter Test Bench

Raising the standards of water meter accuracy testing...


Collection and weighing testing method for the Built-in compensation Mass/Volume based on
determination of the intrinsic error of indication the application of the Tanaka equation.
of residential water meters according to ISO
4064-2 and OIML R49-2 international standards. Integrated Water Reservoir for recycling the
testing water, makes it a “plug & play” installa-
Capable of testing water meters sizes DN15 and
tion equipment. No need for further infraestruc-
DN20, both of the “traditional” mechanical type
ture.
as well as the new generation “static” type water
meters. Built-in automatic pumping system based on
Exceeds by far the requirements of testing water submersible pump, constant pressure auto-
meters under the AWWA C715-18 Standard and matic VFD control and elevated constant
the updated AWWA M6 Manual. head tank.

High accuracy weighing platforms, digitally Automatic PLC control with Touch Screen
integrated to automatic PLC control. HMI.
Capable of accurately testing water metes at
Easy to use, intuitive operation.

www.ibpcal.com “I-B-P-Cal” is the Spanish acronym for


Puebla, Mexico “Test Bench Engineering and Calibrations, Inc”
Model G 15-20 Technical Data
Testing Capacity:

10 water meters size DN15 x 110 mm length


10 water meters size DN15 x 165 mm length
Instrumentation:
10 water meters size DN15 x 190 mm length
10 water meters size DN20 x 190 mm length Water temperature measurement
Optional: 5 water meters size DN25 x 260 mm length In Volumetric Reference Tanks and in Water Reservoir
Temperature transmitters integrated to PLC with display in HMI
Estimated average productivity: 140 meters tested daily
Range: 0-50°C Accuracy ±1% FS Reading Res. 0.1°C
Water pressure at bench Inlet and Outlet:
Volumetric Reference:
Pressure Transmitter Range: 0-150 psi. Accuracy ±0.5% FS
Scale 1: Weighing range
from 10 Kg. to 200 Kg. Reading Resolution: 10 Grams. Integrated Pumping System:

Scale 2: Weighing range


Reading Resolution: 5 Grams.
from 1 Kg. to 30 Kg.
em ipsum
Built-in Pumping System:
Testing Flowrate Range:
Integrated Water Reservoir - 1,200 litre capacity
2.0 l/h to 6,500 l/h
Submersible Pump with Automatic VFD control
Testing branch 1: from 2.0 to 50 l/h
Requires 220 VAC - 25 Amp Power Supply
Testing branch 2: from 20 to 300 l/h
Quiet and automatic operation
Testing branch 3: from 100 to 1,200 l/h

Testing branch 4: from 300 to 6,500 l/h

Flow Measurement:
Electromagnetic Ultrasonic
Additional Instrumentation:
Max. Error: ±0.5% of reading Better than ±1% of reading
Thermo-hygrometer for measurement of ambient reference conditions:
Repeatability: ±0.1% + 0.005% of FS ±0.2% of FS Water Temperature. Ambient Temperature.
Pulse Output integrated in PLC control Athmospheric Pressure and Relative Humidity.
Programmable display unit (metric or Imperial)

GENERAL DIMENSIONS
INSTALLATION AND OPERATION REQUIREMENTS

A minimum available space is required for the installation and operation of

general dimensions of the equipment.

An available 220VAC, 25 Amp Electric Supply is required.

The integrated water reservoir and pumping system makes possible to install
the Model G 15-20 virtually in any place where there is enough available area.
No need for expensive infrastructure or special building construction.

elevated Constant Head Tank provided by IBPCal. See details of this


installation in the Model G 15-20 Operation & Maintenance Manual, or
contact us for installation details information.

5A Old St. Joseph Road, Laventille


EXCLUSIVE REPRESENTATION Trinidad - West Indies
Phone: (868) 624-5617 - (868) 624-5618
FOR ALL CARICOM COUNTRIES email: sales@landwengineering.com
website: www.landwengineering.com