You are on page 1of 1

DITEX TECHNOLOGIES - Loc. Mandella - 37019 Peschiera del Garda VR - ITALY info@ditex.it 17/09/2014-16.

44

OK WORKSHOP ALCOA DIESEL


46 2003 CUSTOMER #ID 02.14.0760
0 NOV EMAIL a.alcoadiesel@gmail.com
ORDER #ID

#0445110023 TURAN INJ 1 INJ 2 INJ 3 INJ 4

EQUIPMENT #1 CRI 1000 NEW STYLE V


PIEZO REFILL
EQUIPMENT #2 0 µW
EQUIPMENT #3 DX73615 DINAMIC CAPACITANCE µF
ADAPTOR 0 Bottom L µH
DELIVERY PIPE DX74251+DX74265 Top L µH
BACKLEAKAGE PIPE DX73261 A
COIL LIFT
CURRENT PROFILE 0 µm
INJ TYPE SOLENOID V
PIEZO LIFT
µm
TEST PLAN NOT SUITABLE FOR CODING PURPOSES RESISTANCE Ω
INSULATION MΩ

RAIL PRESSURE CRI 1000 NEW STYLE Q_TARGET ±∆ BL_MAX


_________ _________ _________ _________
NOTES
#
cm3/1000 cm3/1000 cm3/1000
BAR OPENING TIME pos/µsec Q BL Q BL Q BL Q BL
strokes strokes strokes

A 1350 pos 6 3 minutes

B 1400 OFF 30 Leak test

1 1350 950 µsec 31,0 2,4 46


ISO 4113 40°C ± 2°C
2 800 500 µsec 13,2 2,0
3 250 650 µsec 4,8 1,5
4 800 170 µsec 1,3 1,0
5

17/09/2014-16.44 DITEX TECHNOLOGIES reserves the right to change, modify and/or withdraw the information in this TEST DATA at any time without notice. Therefore it is recommended to order latest test plan from