You are on page 1of 1

DITEX TECHNOLOGIES - Loc. Mandella - 37019 Peschiera del Garda VR - ITALY info@ditex.it 23/04/2013-10.

10

OK WORKSHOP ALCOA DIESEL


46 2012 CUSTOMER #ID 02.14.0760
0 JUL EMAIL a.alcoadiesel@gmail.com
ORDER #ID

#0445110029 TURAN INJ 1 INJ 2 INJ 3 INJ 4

EQUIPMENT #1 CRI 1000 NEW STYLE V


PIEZO REFILL
EQUIPMENT #2 0 µW
EQUIPMENT #3 DX73614 DINAMIC CAPACITANCE µF
ADAPTOR 0 Bottom L µH
DELIVERY PIPE DX74251+DX74265 Top L µH
BACKLEAKAGE PIPE DX73261 A
COIL LIFT
CURRENT PROFILE 0 µm
INJ TYPE CRIP 1 V
PIEZO LIFT
µm
TEST PLAN NOT SUITABLE FOR CODING PURPOSES RESISTANCE Ω
INSULATION MΩ

RAIL PRESSURE CRI 1000 NEW STYLE Q_TARGET ±∆ BL_MAX


_________ _________ _________ _________
NOTES
#
cm3/1000 cm3/1000 cm3/1000
BAR OPENING TIME pos/µsec Q BL Q BL Q BL Q BL
strokes strokes strokes

A 1350 pos 6 3 minutes

B 1400 OFF 30 Leak test

1 1300 1000 µsec 59,0 4,0 46


ISO 4113 40°C ± 2°C
2 500 675 µsec 18,2 3,0
3 230 725 µsec 2,8 1,4
4 500 250 µsec 1,6 1,3
5

23/04/2013-10.10 DITEX TECHNOLOGIES reserves the right to change, modify and/or withdraw the information in this TEST DATA at any time without notice. Therefore it is recommended to order latest test plan from