Spacer 03
EIGHT-BUNDLE SPACER DAMPER 04

SIX-BUNDLE SPACER DAMPER 05

QUAD SPACER DAMPER 06

TRIPLE SPACER DAMPER 07

TWIN SPACER DAMPER 08

Vibration Damper 10
BOLTED VIBRATION DAMPER FOR CONDUCTOR 11

PREFORMED VIBRATION DAMPER FOR CONDUCTOR 12

SPIRAL VIBRATION DAMPER 13

Splicing Fittings 15
MID-SPAN JOINT SLEEVE 16

PARALLEL GROOVE CLAMP 18

PREFORMED SPLICE ROD 19

REPAIR ROD 20

REPAIR SLEEVES 21

Protective Fittings 23
ARCING HORN 24

ARCING RING 25

ARMOUR ROD 26

COUNTER WEIGHT 27

GRADING RING 28

www.jiangdong-group.com 02
SHIELDING RING 30

Link Fittings 31
ADJUSTER PLATE 32

BALL EYE 33

CHAIN LINK 35

CLEVISES 36

CLEVISES TONGUE 37

EXTENSION ROD 38

EYE LINK 40

SHACKLE 41

SOCKET CLEVIS 42

STRAPS 43

TURNBUCKLET 44

U BOLT 45

YOKE PLATE 46

Tension clamp 48
BOLTED TENSION CLAMP 49

COMPRESSED TENSION CLAMP 50

WEDGE TENSION CLAMP 51

Suspension Clamp 53
ARMOUR GRIP SUSPENSION CLAMP FOR
54
CONDUCTOR
TRUNNION SUSPENSION CLAMP 55

www.jiangdong-group.com 03
ENVELOPE TYPE SUSPENSION CLAMP 56

Insulator 58
COMPOSITE LONG ROD INSULATOR 59

GLASS INSULATOR 69

Arrester 71
HIGH VOLTAGE LINE WITH GAP ARRESTER 72

Conductor 74
CONDUCTOR 75

www.jiangdong-group.com 04
LINE SYSTEM

Spacer

Spacers are installed on


multiple bundle conductors to
keep certain distance among
each other so as to avoid
impact, restrain wind vibration
and sub-span oscillation.

www.jiangdong-group.com 05
LINE SYSTEM SPACER

Products
Eight-Bundle Spacer Damper
Eight-Bundle Spacer Dampers are to control
aeolian vibration and sub-span oscillation. Also
to maintain conductor spacing and restore con-
ductor spacing after a short circuit occurs.

Technical features:
1. Spacer Dampers are available for
eight bundle conductor arrangement
and are suitable for use on all kinds of
conductors constructions including
high temperature conductors;
2. The shape of the clamps has been

designed to be corona free even at the highest voltages;


3. The Material for the frame and the clamps are Al.alloy (Casting or Forging).

Product advantages:
1. We have supplied forged spacer dampers for transmission lines;
2. Computer simulation software TIII , which can do vibration study for installation
scheme of bundle spacer, or the combination of spacer and vibration dampers;
3. We can design the spacer damper according to the special requirements and differ-
ent standards.

Dimensions (mm)
Catalog No. Suitable Conductor (mm)
L D

FJZ-840/31D 30.5~31.4 400 30.5~31.4

FJZ-840/34D 33.5~34.4 400 33.5~34.4

FJZ-840/41D 40.5~41.4 400 40.5~41.4

Remark: *L1, *L2, *C, *M, please refer to related product drawings.

www.jiangdong-group.com 06
LINE SYSTEM SPACER

Six-Bundle Spacer Damper


Six-Bundle Spacer Dampers are to control ae-
olian vibration and sub-span oscillation. Also to
maintain conductor spacing and restore con-
ductor spacing after a short circuit occurs.

Technical features:
1. Spacer Dampers are available for six
bundle conductor arrangement and are
suitable for use on all kinds of conduc-
tors constructions including high tem-
perature conductors;
2. The shape of the clamps has been de-

signed to be corona free even at the highest voltages;


3. The Material for the frame and the clamps are Al.alloy (Casting or Forging).

Product advantages:
1. We have supplied forged spacer dampers for transmission lines;
2. Computer simulation software TIII , which can do vibration study for installation
scheme of bundle spacer, or the combination of spacer and vibration dampers;
3. We can design the spacer damper according to the special requirements and differ-
ent standards.

Dimensions (mm)
Catalog No. Suitable Conductor (mm)
L D

FJZ-645/41D 40.5-41.4 450 40.5-41.4

FJZ-650/43D 42.5-43.4 500 42.5-43.4

Remark: *L, *D, please refer to related product drawings.

www.jiangdong-group.com 07
LINE SYSTEM SPACER

Quad Spacer Damper


Quad Spacer Dampers are to control aeoli-
an vibration and sub-span oscillation. Also to
maintain conductor spacing and restore con-
ductor spacing after a short circuit occurs.

Technical features:
1. Spacer Dampers are available for
quad bundle conductor arrangement
and are suitable for use on all kinds of
conductors constructions including
high temperature conductors;
2. The shape of the clamps has been
designed to be corona free even at the highest voltages;
3. The Material for the frame and the clamps are Al.alloy (Casting or Forging).

Product advantages:
1. We have supplied forged spacer dampers for transmission lines;
2. Computer simulation software TIII , which can do vibration study for installation
scheme of bundle spacer, or the combination of spacer and vibration dampers;
3. We can design the spacer damper according to the special requirements and differ-
ent standards.

Dimensions (mm)
Catalog No. Suitable Conductor (mm)
L1 D

FJZ-440/28D 27.6-28.4 400 27.6-28.4

FJZ-440/29D 28.6-29.4 400 28.6-29.4

FJZ-440/32D 31.5-32.4 400 31.5-32.4

FJZ-445/27D 26.5-27.4 450 26.5-27.4

FJZ-445/29D 28.5-29.4 450 28.5-29.4

FJZ-450/26D 25.5-26.4 500 25.5-26.4

Remark: *L1, *D, please refer to related product drawings.

www.jiangdong-group.com 08
LINE SYSTEM SPACER

Triple Spacer Damper


Triple Spacer Dampers are to control aeoli-
an vibration and sub-span oscillation. Also to
maintain conductor spacing and restore con-
ductor spacing after a short circuit occurs.

Technical features:
1. Spacer Dampers are available for triple
bundle conductor arrangement and are
suitable for use on all kinds of conduc-
tors constructions including high tem-
perature conductors;
2. The shape of the clamps has been de-
signed to be corona free even at the highest voltages;
3. The Material for the frame and the clamps are Al.alloy (Casting or Forging).

Product advantages:
1. We have supplied forged spacer dampers for transmission lines;
2. Computer simulation software TIII , which can do vibration study for installation
scheme of bundle spacer, or the combination of spacer and vibration dampers;
3. We can design the spacer damper according to the special requirements and differ-
ent standards.

Dimensions (mm)
Catalog No. Suitable Conductor (mm)
L1 D

FJZ-340/28D 27.5-28.4 400 27.5-28.4

FJZ-345/31 30.5-31.4 400 30.5-31.4

FJZ-345/28D 27.5-28.4 450 27.5-28.4

FJZ-350/27D 26.5-27.4 500 26.5-27.4

FJZ-350/33D 32.5-33.4 500 32.5-33.4

Remark: *L1, *D, please refer to related product drawings.

www.jiangdong-group.com 09
LINE SYSTEM SPACER

Twin Spacer Damper

Twin Spacer Dampers are used to control aeo-


lian vibration and sub-span oscillation. Also to
maintain conductor spacing and restore con-
ductor spacing after a short circuit occurs.

Technical features:
1. Spacer Dampers are available for twin bundle conductor arrangement and are suitable
for use on all kinds of conductors constructions including high temperature conductors;
2. The shape of the clamps has been designed to be corona free even at the highest volt-
ages;
3. The Material for the frame and the clamps are Al.alloy (Casting or Forging).

Product advantages:
1. We have supplied forged spacer dampers for transmission lines;
2. Computer simulation software TIII, which can do vibration study for installation
scheme of bundle spacer, or the combination of spacer and vibration dampers;
3. We can design the spacer damper according to the special requirements and differ-
ent standards.

Dimensions (mm)
Catalog No. Suitable Conductor (mm)
L D

FJZ-240/22D 21.5-22.4 400 21.5-22.4

FJZ-240/24D 23.5-24.4 400 23.5-24.4

www.jiangdong-group.com 10
LINE SYSTEM SPACER

Dimensions (mm)
Catalog No. Suitable Conductor (mm)
L D

FJZ-240/25D 24.5-25.4 400 24.5-25.4

FJZ-240/26D 25.5-26.4 400 25.5-26.4

FJZ-240/27D 26.5-27.4 400 26.5-27.4

FJZ-240/29D 28.5-29.4 400 28.5-29.4

FJZ-245/27D 26.5-27.4 450 26.5-27.4

Remark: *L, *D, please refer to related product drawings.

www.jiangdong-group.com 11
LINE SYSTEM

Vibration Damper

Vibration Dampers are used


to absorb Aeolian Vibrations
of conductor of transmission
lines, as well as ground
wire, OPGW, and ADSS.

www.jiangdong-group.com 12
LINE SYSTEM VIBRATION DAMPER

Products
Bolted Vibration Damper
for conductor
The vibration damper has been designed
to provide the best possible protection
from aeolian vibration for conductors and
earth wires (including OPGW) used for elec-
tric power transmission and distribution.

Technical features:
1. Vibration dampers are designed to dis-
sipate the maximum amount of vibration
energy to prevent fatigue damage to the
strands of the conductors;
2. Vibration damper has an asymmetric de-
sign that features 4 resonant frequencies.

Product advantages:
1. Computer simulation software TIII. This computer model identifies the optimum
damper placement on the span. Of which the development has been verified by
decades of testing and field measurements.
2. We have own test lab which has CNAS certificate(IEC 17025). We can do all type
tests for vibration damper according to IEC 61897, AS 1154.1, etc. Even damper effec-
tiveness evaluation test for large span.
3. We also can provide breakaway bolt for this vibration dampers as per requirements.

Main Line-sec- Dimensions (mm)


Type tion (mm²) L D h h
FR-1 7.0~12.0 429 48 81 50
FR-2 18.0~22.0 429 48 81 50
FR-3 18.0~28.0 505 57 91 60
FR-4 23.0~36.0 550 64 97 60
FR-4/39 37.0~39.0 550 64 127 60

Remark: *L, *D, *h, *α, please refer to related product drawings.

www.jiangdong-group.com 13
LINE SYSTEM VIBRATION DAMPER

Preformed Vibration Damper


for conductor
The vibration damper is to provide the best possi-
ble protection from aeolian vibration for conduc-
tors and earth wires (including OPGW). It is used
for electric power transmission and distribution.

Technical features:
1. Vibration dampers are to dissipate the
maximum amount of vibration ener-
gy to prevent fatigue damage to the
strands of the conductors;
2. Vibration damper has an asymmetric
design that features 4 resonant fre-
quencies.

Product advantages:
1. Computer simulation software TIII. This computer model identifies the optimum
damper placement on the span whose development has been verified by decades of
testing and field measurements.
2. We have own test lab which has CNAS certificate(IEC 17025). We can do all type
tests for vibration damper according to IEC 61897, AS 1154.1, etc. test standards, even
damper effectiveness evaluation test for large span.
3. This design can avoid stress concentration and it is suitable for stress sensitive con-
ductors.

Dimensions (mm)
Applicable Volt-
Catalog No. age L L1 H L2 D

FRYJ-1/2 95/20 375 55 70 720 4


FRYJ-1/3 150/20 375 55 70 720 4
185/30
FRYJ-2/4 240/30 320 55 70 860 4
240/40
300/25
FRYJ-3/5 380 57 90 860 4
300/40
400/35
FRYJ-4/5 510 60 90 930 4
400/50
www.jiangdong-group.com 14
LINE SYSTEM VIBRATION DAMPER

Dimensions (mm)
Applicable Volt-
Catalog No. age L L1 H L2 D

500/45
FRYJ-4/6 630/45 570 60 90 1020 4
630/55

Remark: *L, *L1, *H, *L2, *D, please refer to related product drawings.

Spiral Vibration Damper


Spiral Vibration dampers are designed to
control vibration on ADSS or small diam-
eter conductors (including OPGW).

Technical features:
1. Vibration dampers do not dissipate
energy, but control vibration to disrupt
vibration build up, by impacting on the
cable or the conductor;
2. Preformed design can hold the cable
tightly without affecting the attenuation
of the fibers in the cable.

Product advantages:
1. For ADSS used in the transmission lines with voltage higher than 110kV, we can provide
anti-E corrosion type;
2. Using a high impact strength, UV resistant plastic. They are suitable for use in all envi-
ronments, and may be used for conductor temperatures up to 75℃;
3. It is easy to install on the cable.

Dimensions
Catalogue number
Range diameter (mm)
Resistance to (mm)
Normal type L1 L2
E-corrosion type
FLP-10 FLN-10 10.39~11.70 300 1050

www.jiangdong-group.com 15
LINE SYSTEM VIBRATION DAMPER

Dimensions
Catalogue number
Range diameter (mm)
Resistance to (mm)
Normal type L1 L2
E-corrosion type
FLP-11 FLN-11 11.71~13.0 300 1050

FLP-12 FLN-12 13.01~14.30 300 1050

FLP-12.5 FLN-12.5 14.31~15.70 300 1050

FLP-13 FLN-13 15.71~17.10 300 1050

FLP-14 FLN-14 17.11~18.50 300 1050

FLP-16 FLN-16 18.51~20.00 300 1050

FLP-17 FLN-17 20.01~21.50 300 1050

FLP-18 FLN-18 21.51~22.90 300 1050

Remark: *L, *D, *h, *α, please refer to related product drawings.

www.jiangdong-group.com 16
LINE SYSTEM

Splicing Fittings

The splicing fittings are used to


join kinds of bare conductors
and lightning conductors, which
bear the same electric load
as conductors. Additionally,
splicing fittings are generally
divided into compression
type and preformed type.

www.jiangdong-group.com 17
LINE SYSTEM SPLICING FITTINGS

Products
Mid-span Joint Sleeve

The splicing fitting is to join kinds of bare conduc-


tors and ground wires. It bears the same electric
load as conductors. Mid-span Joint Sleeve bears
all the tension of conductors and ground wires.
According to the tensile condition, splicing fittings
include the force-bearing type and non-force-
bearing type. Splicing fittings include compression
type and preformed type. And the compression
type includes hydraulic compression, explosive
compression, and compression with pliers.
Technical features:

1. There should be a good contact surface between the splicing fitting and the conduc-
tor wire or ground wires;
2. The splicing fitting should not reduce the conductivity of the wire;
3. The resistance between the compression type splicing fittings and the two ends of
the wire connection should not be greater than the resistance of the same length
wire, and for the non-compression type splicing fittings, it should not be greater than
1.1 times the resistance of the same length wire.

Product advantages:
1. The hydraulic Mid-span Joint Sleeve has sufficient mechanical strength and good
electrical contact performance;
2. It has advantages such as Uniform pressure and material saving.

www.jiangdong-group.com 18
LINE SYSTEM SPLICING FITTINGS

Suitable Conduc- Dimensions (mm) Slip Strength


Catalog No.
tor D D1 L L1 (kN)
JYD-95/15 95/15 30 14 340 70 33.25
JYD-95/55 95/55 36 24 370 120 74.2
JYD-120/20 120/20 34 14 380 80 38.95
JYD-150/20 150/20 30 16 360 80 44.3
JYD-150/25 150/25 30 16 430 85 51.4
JYD-185/25 185/25 34 18 465 90 56.45
JYD-185/30 185/30 34 18 465 110 61.104
JYD-240/30 240/30 36 20 480 100 71.78
JYD-240/40 240/40 36 20 460 100 79.2
JYD-300/25 300/25 40 20 480 90 79.24
JYD-300/40 300/40 40 20 490 100 87.61
JYD-300/50 300/50 40 22 490 120 98.23
JYD-300/70 300/70 40 24 520 130 121.6
JYD-400/35 400/35 45 22 540 100 99
JYD-400/50 400/50 45 24 570 12 117.23
JYD-400/65 400/65 48 26 650 130 128.44
JYD-500/45 500/45 52 24 670 110 121.7
JYD-630/45 630/45 60 24 690 110 141.26
JYD-720/50 720/50 60 24 820 125 161.5

Remark: *D, *D1, *L, *L1, please refer to related product drawings.

www.jiangdong-group.com 19
LINE SYSTEM SPLICING FITTINGS

Parallel Groove Clamp

Parallel Groove Clamp is for parallel non-tension


connection of small and medium section cables.

Technical features:
The fastening pressure of the bolt will be fixed on the upper and lower grooves with the
connecting wire of the bolt, which is made of board and aluminum alloy material.

Product advantages:
1. The surface is smooth and flat without burrs;
2. High-quality aluminum alloy material, strong corrosion resistance, not easy to rust
and age;
3. The product type is different, can apply to multiple cross section cables;
4. It is to connect two kinds of cables that approximate the outside diameter.

Dimensions (mm) Section area


Number of
Catalog No. of cable
Fig.No. L1 L2 M Bolt
(mm2)
JB-1 1 80 43 12 2 25-50

JB-2 2 114 50 12 3 70-95

JB-3 2 140 62 16 3 120-150

JB-4 2 144 70 16 3 185-240

JB-5 3 200 90 16 4 300-460

www.jiangdong-group.com 20
LINE SYSTEM SPLICING FITTINGS

Dimensions (mm) Section area


Number of
Catalog No. of cable
Fig.No. L1 L2 M Bolt
(mm2)
JB-6 3 230 117 16 4 500-630

Remark: *L1, *L2, *M, please refer to related product drawings.

Preformed Splice Rod

The splicing fitting is primarily used to join


kinds of bare conductors and ground wires.
It bears the same electric load as conduc-
tors. Preformed Splice Rod bears all the ten-
sion of conductors and ground wires.

Technical features:
1. There should be a good contact surface between the splicing fitting and the con-
ductor wire or ground wires;
2. The splicing fitting should not reduce the conductivity of the wire.

Product advantages:
1. It has electrical contact performance;
2. With advantages such as uniform pressure and material saving;
3. Can effectively protect the wires and easy to install.

www.jiangdong-group.com 21
LINE SYSTEM SPLICING FITTINGS

Dimensions (mm)
Catalog No. Suitable Conductor
D d L

JL-282LH 282mm² 30.6 6.3 3000

JL-375LH 375mm² 36.5 7.8 3680

JL-470LH 470mm² 39.0 7.8 4400

JL-633LH 633mm² 42.7 7.8 5400

Remark: *D, *d, *L, please refer to related product drawings.

Repair Rod
The Repair Rod is primarily used to join kinds
of bare conductors and ground wires. It bears
the same electric load as conductors.

Technical features:
1. There should be a good contact surface
between the Repair Rod and the con-
ductor wire or ground wires;
2. The splicing fitting should not reduce
the conductivity of the wire.

Product advantages:
1. The repair rod has electrical contact performance;
2. It has advantages such as uniform pressure and material saving;
3. The repair rod can effectively protect the wires and easy to install.

Dimensions (mm)
Catalog No. Suitable Conductor
L D
FYB-120/20 140mm² 3.5 1500

www.jiangdong-group.com 22
LINE SYSTEM SPLICING FITTINGS

Dimensions (mm)
Catalog No. Suitable Conductor
L D
FYB-150/25 175mm² 3.5 1500

FYB-185/30 215mm² 4.6 1800

FYB-200/30 230mm² 4.6 1300

FYB-400/50 450mm² 6.3 2200

Remark: *L1, *D, please refer to related product drawings.

Repair Sleeves
The splicing fitting is primarily used to join kinds
of bare conductors and ground wires. Re-
pair Sleeves bear the same electric load as
conductors.

Technical features:
1. There should be a good contact surface
between the splicing fitting and the
conductor wire or ground wires;
2. The splicing fitting should not reduce
the conductivity of the wire;

3. The resistance between the compression type splicing fittings and the two ends of the
wire connection should not be greater than the resistance of the same length wire, and
for the non-compression type splicing fittings, it should not be greater than 1.1 times the
resistance of the same length wire.

Product advantages:
1. The Repair Sleeves have electrical contact performance;
2. It has advantages such as Uniform pressure and material saving.

www.jiangdong-group.com 23
LINE SYSTEM SPLICING FITTINGS

Dimensions (mm)
Catalog No. Suitable Conductor
D L R

JX-95/55 150mm² 32 180 8.75

JX-150/25 175mm² 30 150 9.25

JX-240/40 280mm² 36 200 11.5

JX-300/40 340mm² 40 250 13

JX-400/50 350mm² 45 320 14.5

JX-500/35 535mm² 52 320 16

JX-630/45 675mm² 60 370 18

JX-720/50 770mm² 60 370 19

JX-50BG 50mm² 20 160 4.8

JX-70BG 70mm² 22 190 5.8

JX-120BG 120mm² 30 200 7.5

JX-185BG-20 185mm² 45 180 9.5

Remark: D, *L, *R, please refer to related product drawings.

www.jiangdong-group.com 24
LINE SYSTEM

Protective Fittings

The protective fittings are


used to protect conductors,
insulators, and so on, including
but not limited to grading ring,
counter weight, armor rod,
etc… Protective fittings can
suffer the aeolian vibration to
make no fatigue damage.

www.jiangdong-group.com 25
LINE SYSTEM PROTECTIVE FITTINGS

Products
Arcing Horn

Arcing Horn is Ring-shaped protective hardware


to prevent arc flash-over along the insulator.

Technical features:
The lightning impulse discharge of the Arcing Horn should be lower than the impulse
intensity of the insulator string, and its power frequency discharge voltage should be
higher than the operating over-voltage of the system.

Product advantages:
1. The surface is polished, smooth without burrs;
2. The Arcing Horn can effectively protect the wires and easy to install.

Dimensions (mm)
Catalog No.
Fig.No. L H Ф1 Ф2 M

ZH1-3517 1 356 177 16 14 12

ZH2-3518 2 356 180 16 14 12

Remark: *L, *H, *ΦФ1, *ΦФ2, *M, please refer to related product drawings.

www.jiangdong-group.com 26
LINE SYSTEM PROTECTIVE FITTINGS

Arcing Ring

Arcing Ring is the Ring-shaped protective hardware,


which can prevent arc flash-over along the insulator.

Technical features:
The lightning impulse discharge of the Arcing Ring should be lower than the impulse
intensity of the insulator string, and its power frequency discharge voltage should be
higher than the operating over-voltage of the system.

Product advantages:
1. The surface is polished, smooth without burrs;
2. The Arcing Ring can effectively protect the wires and easy to install.

Dimensions (mm)
Catalog No.
Fig.No. L L1 H D L2 M

ZH6-4431 4 428 203 337 27 100 12

ZH6-4422 5 445 203 220 27 73 12

ZH6-4430 6 445 100 300 27 320 12

ZH6-4420 7 445 73 200 27 320 12

Remark: *L, *L1, *H, *D, *L2, *M, please refer to related product drawings.

www.jiangdong-group.com 27
LINE SYSTEM PROTECTIVE FITTINGS

Armour Rod
Armour Rod is a spiral wound on the wire to
increase the stiffness and vibration resist-
ance of the wire at the winding location.

Technical features:
Rounded head or duckbill at the end of the
guard line.

Product advantages:
1. Less wear on the wire;
2. Good corrosion resistance;
3. The Armour Rod can effectively protect the wires and easy to install.

Suitable Conduc- Dimensions (mm)


Catalog No. Number
tor D d L
FYH-95/20 95/20 3.6 11.4 1400 13
FYH-150/25 150/25 3.6 13.0 1400 14
FYH-150/25 150/25 3.6 14.2 1500 16
FYH-185/30 185/30 4.6 15.7 1800 14
FYH-240/30 240/30 4.6 17.9 1900 16
FYH-240/40 240/40 4.6 17.9 1900 16
FYH-300/25 300/25 6.3 19.7 2000 13
FYH-300/40 300/40 6.3 19.9 2000 13
FYH-400/35 400/35 6.3 22.3 2200 14
FYH-400/50 400/50 6.3 23.0 2200 14
FYH-400/65 400/65 6.3 23.2 2200 14
FYH-400/95 400/95 6.3 24.8 2500 14

www.jiangdong-group.com 28
LINE SYSTEM PROTECTIVE FITTINGS

Suitable Conduc- Dimensions (mm)


Catalog No. Number
tor D d L
FYH-500/35 500/35 6.3 24.9 2500 16
FYH-500/45 500/45 6.3 24.9 2500 16
FYH-500/65 500/65 6.3 25.7 2500 16
FYH-630/45 630/45 7.8 27.9 2500 15
FYH-630/55 630/55 7.8 28.5 2500 15
FYH-630/80 630/80 7.8 28.9 2500 15
FYH-720/50 720/50 7.8 30.8 3000 15

Remark: *D, *d, *L, please refer to related product drawings.

Counter Weight

Counter weight is a protective fitting used when


the insulation gap between the linear pole tow-
er pendant insulator string or the non-linear pole
tower jumper is insufficient for the pole tower.

Technical features:
Painted or hot-dip galvanized grey iron.

www.jiangdong-group.com 29
LINE SYSTEM PROTECTIVE FITTINGS

Product advantages:
Low cost and environmental protection.

Dimensions (mm)
Catalog No.
L L1 B1 H H1 B D

ZC-12 70 50 15 100 40 32 280

ZC-1 55 65 13 100 30 38 280

ZC-25 70 50 20 100 40 60 280

FZC-10 300 120 130 23 - 20 34

Remark: L, *L1, *B1, *H, *H1,*B, *D, please refer to related product drawings.

Grading Ring

Grading Ring is a ring-shaped protective fit-


ting that does not show corona phenomenon
to other fittings or parts within the shielded
range. It can reduce power loss and prolong
the service life of fittings and insulators.

www.jiangdong-group.com 30
LINE SYSTEM PROTECTIVE FITTINGS

Technical features:
The high voltage can be evenly distributed around the object to ensure that there is
no potential difference between various parts of the ring. So as to achieve the effect of
voltage equalization.

Product advantages:
1. The surface is polished, smooth without burrs;
2. High mechanical strength, no loosening or fatigue damage caused by wind vibration.

Dimensions (mm)
Catalog No.
Fig.No. L L1 L2 H D S M

FJY-32/700/275 1 700 600 - 275 32 80 16

FJY-50/700/340 1 700 600 - 340 50 80 16

FJY-80/1000/375 1 1000 900 - 250 50 80 16

FP-50/800/900 2 800 - - 900 50 80 16

FJY-60/600/360-120 2 600 - - 360 60 80 16

FJY-80/900/360-120 2 900 - - 360 80 80 16

FJ-80/2000/1150 2 2000 - - 1150 80 160 16

FJ-800VD 2 1120 - - 600 120 80 16

FJD-32/1000/215 3 1000 600 - 215 32 60 16

FJD-50/1050/260 3 1050 600 - 260 50 60 16


FJD-60/1200/330-
3 1200 600 - 330 60 60 16
160
FJD-80/1500/330-
3 1500 900 - 330 60 60 16
160
FJ-800VS-650 5 650 1120 1770 800 120 80 16

FJ-800VS-800 5 800 1120 1920 700 120 80 16

FJ-800N3-650/810 4 650 1120 2420 810 120 80 18

FJ-800V3-650 4 650 1120 2420 790 120 80 18

FJ-800V3-800 4 800 1240 2820 585 120 80 18

FJ-800N3-1000 4 1000 1240 3240 585 120 80 18

Remark: *L, *L1, *L2,*H, *D, *S *M, please refer to related product drawings.

www.jiangdong-group.com 31
LINE SYSTEM PROTECTIVE FITTINGS

Shielding Ring

Shielding Ring is a ring-shaped protective fit-


ting that does not show corona phenome-
non to other fittings or parts within the shield-
ed range. It can reduce power loss and prolong
the service life of fittings and insulators.

Technical features:
The high voltage can be evenly distributed around the object to ensure that there is
no potential difference between various parts of the ring, so as to achieve the effect of
voltage equalization.

Product advantages:
1. The surface is polished, smooth without burrs;
2. High mechanical strength, no loosening or fatigue damage caused by wind vibration.

Dimensions (mm)
Catalog No.
Fig.No. L L1 H D S M
FJP-300XL 1 600 800 220 32 80 16

FJPE-32/1050/360/150 1 1050 560 360 32 80 16

FJPE-50/1900/350 2 1900 900 350 50 60 16

FJPE-60/1900/380 2 1900 1080 380 60 60 16

FJPE-80/1900/380 2 1900 1100 380 80 60 16

Remark: *L, *L1, *H, *D, *S, *M, please refer to related product drawings.

www.jiangdong-group.com 32
LINE SYSTEM

Link Fittings

The link fittings is primarily


used for the link of insulators
and the connection of fittings
it bears mechanical load.All
the ferrous should be hot-dip
galvanized. Our link fittings is
smooth and free of burrs with
high mechanical strength.

www.jiangdong-group.com 33
LINE SYSTEM LINK FITTINGS

Products
Adjuster Plate
Adjuster Plate is a connection fit-
ting with adjustable length.

Technical features:
The adjuster plate is generally used on
the tension insulator string to adjust the
string length.

Product advantages:
1. The adjuster plate uses hot-dip galvanizing to prevent corrosion;
2. The mechanical strength of the adjuster plate is high.

Dimensions (mm) Rated Failure


Type
Load (kN)
L0 L1 L2 M d b C L

PT-7 45 30 45 16 18 16 18 225-345 70
PT-10 50 40 50 18 20 16 20 250-390 100
PT-12 60 75 60 22 24 16 24 315-495 120
PT-16 65 50 65 24 26 18 26 325-505 160
PT-21 70 90 70 27 30 26 30 370-580 210
PT-25 80 90 80 30 33 30 34 420-660 250
PT-30 85 100 85 36 39 32 38 455-710 300
PT-50 70 80 100 42 45 38 40 740-1280 500
PT-60 90 80 100 48 51 42 44 820-1390 600
PT-21370-580 70 80 70 24 26 20 24 370-580 210
PT-25420-660 80 90 80 27 30 24 28 420-660 250

www.jiangdong-group.com 34
LINE SYSTEM LINK FITTINGS

Dimensions (mm) Rated Failure


Type
Load (kN)
L0 L1 L2 M d b C L

PT-32420-660 80 90 80 30 33 28 32 420-660 320


PT-42440-680 80 100 80 36 39 32 36 440-680 420
PT-55550-820 90 140 90 36 39 32 36 550-820 550
PT-64600-900 100 150 - 42 45 36 40 600-900 640
PT-84870-1310 110 215 100 48 51 36 44 870-1310 840
PT-110740-1180 110 150 110 52 55 40 48 740-1180 1100
PT-128800-1280 120 160 120 60 64 45 52 800-1280 1280
PT-168690-990 150 240 - 72 76 52 62 690-990 1680

Remark: *L0, *L1, *L2, *M, *d, *b, *C, *L, please refer to related product drawings.

Ball Eye

The ball eye is the fitting used for connec-


tion with the ball & socket insulator.

Technical features:
1. The ball eye is integrally forged from round steel and bears mechanical load;

www.jiangdong-group.com 35
LINE SYSTEM LINK FITTINGS

2. It use hot-dip galvanizing to prevent corrosion;


3. It has high failing load.

Product advantages:
1. The surface is polished, smooth without burrs;
2. High mechanical strength, no loosening or fatigue damage caused by wind vibration.

Dimensions (mm) Designated


Rated Failure
Catalog No. size of cou-
Ф D h d b Load (kN)
pling
QP-4 22.8 12 35 13.5 12 40 11

Q-7 33.3 17 50 22 16 70 16

QP-7 33.3 17 50 20 16 70 16

QP-10 33.3 17 50 20 16 100 16

QP-12 33.3 17 55 24 17 120 16

QP-16 41.0 21 60 26 20 160 20

QP-21D 41.0 21 70 30 24 210 20

QP-25 49.0 25 80 33 28 250 24

QP-30 49.0 25 80 39 28 300 24

QP-16S 33.3 21 60 26 18 160 20

QP-21S 41.0 21 80 26 20 210 20

QP-25S 49.0 25 80 30 24 250 24

QP-32S 49.0 25 80 33 28 320 24

QP-42S 57.0 29 100 39 32 420 28

QP-55110 65 32 110 39 32 550 32

QP-76120 73 37 120 48 36 760 36

QP-84120 81 41 120 51 36 840 40

Remark: *Ф, *D, *h, *d, *b, please refer to related product drawings.

www.jiangdong-group.com 36
LINE SYSTEM LINK FITTINGS

Chain Link
Chain Link is used for the connection of
ring fittings to lengthen the connection size
or change the connection direction.

Technical features:
The chain link is integrally forged from
round steel and bears mechanical load.

Product advantages:
1. The surface is smooth and free of burrs;
2. The chain link uses hot-dip galvanizing to prevent corrosion;
3. The mechanical strength of the chain link is high.

Dimensions (mm) Rated Failure Load


Catalog No.
C D L (kN)
PH-4 18 14 60 40
PH-7 20 16 80 70
PH-10 22 18 100 100
PH-12 24 20 120 120
PH-16 26 22 140 160
PH-21 30 24 160 210
PH-25 34 26 160 250
PH-30 38 30 180 300
PH-16S 26 20 120 160
PH-21S 26 20 130 210
PH-25S 32 24 120 250
PH-32S 34 28 140 320

www.jiangdong-group.com 37
LINE SYSTEM LINK FITTINGS

Dimensions (mm) Rated Failure Load


Catalog No.
C D L (kN)
PH-42S 40 32 160 420
YH-55160 40 32 160 550
YH-64160 42 36 160 640
YH-84190 48 40 190 840
YH-110190 52 48 190 1100

Remark: *C, *D, *L, please refer to related product drawings.

Clevises
Clevises is a steering connection fitting
that changes the connection direction.

Technical features:
Since the connecting directions of the
clevises are at right angles to each other,
they are flexible and adaptable.

Product advantages:
1. The surface is smooth and free of burrs;
2. The clevises uses hot-dip galvanizing to prevent corrosion;
3. The mechanical strength of the clevises is high.

Dimensions (mm) Rated Failure Load


Catalog No.
C1 C2 M1 M2 h (kN)
Z-32135 32 32 30 30 135 320
Z-42150 36 36 36 36 150 420
www.jiangdong-group.com 38
LINE SYSTEM LINK FITTINGS

Dimensions (mm) Rated Failure Load


Catalog No.
C1 C2 M1 M2 h (kN)
Z-50 42 44 42 42 150 500
Z-60 40 40 42 42 180 600
Z-64180 40 40 42 42 180 640
Z-84S 44 44 48 48 180 840
Z-110220 48 48 52 52 220 1100
Z-128220 52 52 60 60 220 1280
Z-168260 62 62 72 72 260 1680

Remark: *C1, *C2, *M1, *M2, *h, please refer to related product drawings.

Clevises Tongue
Clevises Tongue is a steering connection fit-
ting that changes the connection direction.

Technical features:
Since the connecting directions of the clev-
ises tongue are at right angles to each other,
they are flexible and adaptable.

Product advantages:
1. The surface is smooth and free of burrs;
2. The clevises tongue uses hot-dip galvanizing to prevent corrosion;
3. The mechanical strength of the clevises tongue is high.

www.jiangdong-group.com 39
LINE SYSTEM LINK FITTINGS

Dimensions (mm) Rated Failure Load


Catalog No.
C b M d h (kN)
ZBD-0780 20 16 16 18 80 70
ZBD-1080 20 16 18 20 80 100
ZBD-1290 20 16 22 24 90 120
ZBD-16100 24 18 24 26 100 160
ZBD-21100 26 20 24 26 100 210
ZBD-32S 32 28 30 33 136 320

ZBD-42S 38 32 36 39 145 420

ZBD-55150 38 32 36 39 150 550


ZBD-64150 42 36 42 45 150 640
ZBD-84S 44 36 48 51 180 840
ZBD-110250 48 40 52 55 250 1100
ZBD-168S 62 52 72 76 260 1680

Remark: *C, *b, *M, *d, *h, please refer to related product drawings.

Extension Rod
Extension Rod is used for the connection of fittings
to extend the connection distance. The earrings at
both ends of the rod form a 90 angle, and they can
also be used to switch the connection direction.

Technical features:
The extension rod is integrally forged from
round steel and bears a mechanical load.
It can stagger the tension clamps of the
upper and lower conductors of the vertical-
ly arranged split conductors, avoiding the

www.jiangdong-group.com 40
LINE SYSTEM LINK FITTINGS

tension clamps of the upper and lower conductors from colliding or keeping the dis-
tance between the four conductors of the jumper.

Product advantages:
1. The surface is smooth and free of burrs;
2. It uses hot-dip galvanizing to prevent corrosion;
3. The mechanical strength is high.

Dimensions (mm) Rated Failure Load


Catalog No.
D d b L (kN)
YL-0712 18 18 16 120 70
YL-1040 18 20 16 400 100
YL-1243 22 24 18 43 120
YL-1640 22 26 18 400 160
YL-2140S 24 26 20 400 210
YL-2543S 28 30 24 430 250
YL-3253S 30 33 28 530 320
YL-42450 36 39 32 450 420
YL-55350 40 39 32 350 550
YL-64406S 42 45 36 406 640
YL-84426S 50 51 36 426 840
YL-110500S 56 55 42 500 1100

Remark: *D, *d, *b, *L, please refer to related product drawings.

www.jiangdong-group.com 41
LINE SYSTEM LINK FITTINGS

Eye Link
The eye link is the fitting used for the connection
of ring fittings to change the connection direction.

Technical features:
1. The Eye link is integrally forged from
round steel and bears mechanical load;
2. It use hot-dip galvanizing to prevent
corrosion.

Product advantages:
1. The structure is simple;
2. It has high failing load;
3. It can be flexibly rotated without being restricted by direction.

Dimensions (mm) Rated Failure Load


Type
(kN)
D b C d h1 h

ZH-4 12 12.5 18 14 38 70 40
ZH-7 16 16 24 20 57 100 70
ZH-10 18 16 24 20 57 100 100
ZH-12 18 16 22 24 65 115 120
ZH-16 22 18 26 26 75 135 160
ZH-21 24 26 32 30 75 150 210

Remark: *D, *b, *C, *d, *h1, *h, please refer to related product drawings.

www.jiangdong-group.com 42
LINE SYSTEM LINK FITTINGS

Shackle
U shackle is the fitting usually used for installing
insulator strings to the cross arm of a pole or tower.

Technical features:
1. The U shackle is integrally forged from
round steel;
2. It has a wide range of uses.

Product advantages:
1. The structure is simple;
2. It has high failing load;
3. It can be flexibly rotated without being restricted by direction.

Dimensions (mm) Rated Failure Load


Type
(kN)
D b C d h1
U-4 18 12 12 60 16 40
U-7 20 16 16 80 22 70
U-10 22 18 18 85 24 100
U-12 24 22 20 90 30 120
U-16 26 24 22 95 32 160
U-21 30 27 24 100 36 200
U-25 34 30 26 110 40 250
U-30 38 36 30 130 46 300
U-21S 26 24 20 100 32 210
U-25S 30 27 24 110 36 250
U-32S 32 30 28 115 40 320
U-42S 38 36 32 140 45 420

www.jiangdong-group.com 43
LINE SYSTEM LINK FITTINGS

Dimensions (mm) Rated Failure Load


Type
(kN)
D b C d h1
U-50S 40 36 32 150 48 500
U-60G 42 42 36 172 55 600
U-64S 42 42 36 200 55 640
U-64185S 42 42 36 185 55 640
U-84180 44 48 40 180 62 840
U-110200 50 52 48 200 52.5 1100

Remark: *C, *M, *D, *h, *R, please refer to related product drawings.

Socket Clevis
Socket Clevis is the fitting used for connec-
tion with the ball & socket insulator.

Technical features:
1. It uses hot-dip galvanizing to prevent cor-
rosion;
2. It has a high failing load.

Product advantages:
1. It has no direction and can be turned;
2. It is easy to load and unload.

Dimensions (mm) Designated


Rated Failure
Catalog No. size of cou-
C h d b Load (kN)
pling
W-7TG 19.2 70 18 16 70 16

www.jiangdong-group.com 44
LINE SYSTEM LINK FITTINGS

Dimensions (mm) Designated


Rated Failure
Catalog No. size of cou-
C h d b Load (kN)
pling
W-10TG 19.2 70 18 16 100 16

W-12TG 19.2 70 18 16 120 16

W-16TG 23 80 22 18 160 20

W-21TG 23 80 22 18 210 20

Remark: *C, *M, *D, *h, *R, please refer to related product drawings.

Straps
The strap is the fitting used for the connec-
tion of the fittings with the clevis. The straps can
be used to change the string length. It can not
be used to change the connection direction.

Technical features:
It is cut from a steel plate and bears a me-
chanical load.

Product advantages:
1. The surface is smooth and free of burrs;
2. It use hot-dip galvanizing to prevent corrosion;
3. It has high failing load.

Dimensions (mm) Rated Failure


Catalog No.
d b S L Load (kN)
PD-7 18 16 40 70 70
PD-10 20 16 45 80 100

www.jiangdong-group.com 45
LINE SYSTEM LINK FITTINGS

Dimensions (mm) Rated Failure


Catalog No.
d b S L Load (kN)
PD-12 24 16 50 100 120
PD-16 26 22 60 130 160
PD-20 30 26 70 110 200
PD-3012 39 32 80 120 300
PD-50 45 38 110 130 500
PD-16100 26 18 60 100 160
PD-21S 26 20 60 130 210
PD-25400S 30 24 70 400 250
PD-3209S 33 28 78 90 320
PD-42120S 39 32 85 120 420
PD-55151S.1 39 32 94 151 550
PD-64S 45 36 100 135 640
PD-84230S 51 36 122 230 840

Remark: *d, *b, *S, *L, please refer to related product drawings.

Turnbucklet
A connection fitting with adjustable length.

Technical features:
The turnbuckle is generally used on the
tension insulator string to adjust the string
length.

www.jiangdong-group.com 46
LINE SYSTEM LINK FITTINGS

Product advantages:
1. The surface is smooth and free of burrs;
2. The turnbuckle uses hot-dip galvanizing to prevent corrosion;
3. The mechanical strength of the turnbuckle is high.

Dimensions (mm)
Type Rated Failure Load (kN)
d L L1 D b

TB-70ET 17.5 460-640 64 20 16 70


TB-120ET 17.5 460-640 64 20 16 120
TB-160ET 22.0 460-640 64 20 16 160
TB-210ET 22.0 460-640 64 20 19 210

Remark: *d, *L, *L1, *D, *b, please refer to related product drawings.

U Bolt
A connection fitting is used for installing insula-
tor strings to the cross arm of the pole or tower.

Technical features:
Bears mechanical load.

Product advantages:
1. The surface is smooth and free of burrs;
2. The U bolt uses hot-dip galvanizing to prevent corrosion;
3. The mechanical strength of the U bolt is high.

www.jiangdong-group.com 47
LINE SYSTEM LINK FITTINGS

Dimensions (mm)
Catalog No.
C M D h h1
UJ-1880 80 18 18 105 50
UJ-2080 80 20 20 120 60
UJ-2280 80 22 22 126 65
U-1650 50 16 16 100 80
U-1670 70 16 16 122 80
U-1680 80 16 16 122 80
U-1690 90 16 16 140 80
U-1870 70 18 18 122 85
U-1880 80 18 18 122 80
U-2070 70 20 20 135 95
U-2080 80 20 20 130 90
U-2090 90 20 20 145 90
U-2280 80 22 22 118 90

Remark: *C, *M, *D, *h, *h1, please refer to related product drawings.

Yoke Plate

www.jiangdong-group.com 48
LINE SYSTEM LINK FITTINGS

Yoke Plate is a connection fitting used for


the parallel assembly of double insula-
tor strings and multiple insulator strings.

Technical features:
It is cut from a steel plate and bears a mechanical load.

Product advantages:
1. The surface is smooth and free of burrs;
2. The yoke plate uses hot-dip galvanizing to prevent corrosion;
3. The mechanical strength of the yoke plate is high.

Dimensions (mm)
Type Rated Failure Load (kN)
b h d1 d2 L

L-1040 16 70 20 18 400 100


L-1050 16 130 20 18 500 100
L-1060 16 100 20 18 600 100
L-1240 16 70 24 18 400 120
L-1245-1 16 70 24 18 450 120
L-1640 18 100 26 20 400 160
L-1650S 18 130 26 20 500 160
L-1660 18 100 26 20 600 160

Remark: *b, *h, *d1, *d2, *L, please refer to related product drawings.

www.jiangdong-group.com 49
LINE SYSTEM

Tension clamp

The tension clamp is used to


fix the conductor, ground wire
terminals on tension towers of
overhead lines, distribution lines,
and distribution equipments
in substations, power plants,
as well as fixing the guy
wire terminals on poles.

www.jiangdong-group.com 50
LINE SYSTEM TENSION CLAMP

Products
Bolted Tension Clamp
Bolted Tension Clamp is used for fixing the ter-
minal of the conductor and ground wire on the
tension tower. They can bear all or part of the
tension of the conductor and ground wire.

Technical features:
There is no need to cut the wire, and it is fixed
with several U-shaped screws, but the grip
strength is not as good as the compression
type.

Product advantages:
1. Installation is easy, there is no need hydraulic equipment;
2. Each type is applicable to a wide range of conductors.

Suitable diam- Dimensions (mm)


Quantity of U
Type eter of Conduc- Failure load (kN)
bolt
tor (mm) L1 L2 C M

NLL-1 Ø7.6~Ø16.2 128 105 19 16 2 40


NLL-2 Ø8.2~Ø17.0 210 160 22 16 3 70
NLL-3 Ø14.1~Ø18.0 220 213 22 16 3 70
NLL-4 Ø13.6~Ø25.0 320 220 30 18 4 90
NLL-5 Ø16.0~Ø32.0 380 280 36 22 5 100
NLL-6 Ø28.5~Ø46.5 480 380 50 22 6 100

Remark:
1. *L1, *L2, *C, *M, please refer to related product drawings.
2. When the cable diameter range overlaps, it is preferable to use small type.

www.jiangdong-group.com 51
LINE SYSTEM TENSION CLAMP

Compressed Tension Clamp

Compressed Tension Clamps are used for fixing


the terminal of the conductor and ground wire
on the tension tower. They can bear all or part of
the tension of the conductor and ground wire.

Technical features:
Compression type is generally divided into hydraulic pressure and explosion pressure,
and its connection types is ring connection and clevis connection.

Product advantages:
1. The grip strength is high enough, and can bear all the tension of the conductor and
ground wire at most;
2. Steel anchor has high mechanical strength and strong corrosion resistance;
3. The direction of the jumper clamp can be flexibly adjusted according to customer
requirements.

Suitable Con- Dimensions (mm) Slip Strength


Catalog No. ductor section Fig. No.
mm² D1 D2 D3 L1 L2 L3 R (kN)

NY-95/15 95/15 30 14 16 425 55 220 10 33.0 1


NY-95/55 95/55 34 22 18 416 50 220 11 74.0 1
NY-150/25 150/25 26 14 16 480 55 230 8.5 51.4 1
NY-185/30 185/30 34 16 16 470 55 220 9.0 62.0 1
NY-240/30 240/30 36 16 18 500 55 240 10 72.0 1

www.jiangdong-group.com 52
LINE SYSTEM TENSION CLAMP

Suitable Con- Dimensions (mm) Slip Strength


Catalog No. ductor section Fig. No.
mm² D1 D2 D3 L1 L2 L3 R (kN)

NY-240/40 240/40 36 16 18 515 55 240 10 79.0 1


NY-240/55 240/55 36 20 18 535 55 250 11 97.0 1
NY-300/15 300/15 40 14 16 490 50 265 11 65.0 1
NY-300/20 300/20 40 14 18 505 55 265 11 72.0 1
NY-300/25 300/25 40 14 18 515 55 265 11 79.0 1
NY-300/40 300/40 40 16 18 535 55 265 11 88.0 1
NY-400/50 400/50 45 20 20 590 65 280 13 117.0 1
NY-500/35 500/35 52 16 20 620 65 245 14 114.0 2
NY-500/65 500/65 52 22 22 660 70 245 15 146.0 2
NY-630/45 630/45 60 18 22 660 70 290 16 141.0 2
NY-800/55 800/55 65 20 26 740 80 335 19 182.0 2
NY-800/70 800/70 65 22 26 745 85 335 19 197.0 2
NY-800/100 800/100 65 26 30 780 85 335 19 229.0 2

Remark: *D1, *D2, *D3, *L1, *L2, *L3, *R, please refer to related product drawings.

Wedge Tension Clamp


Wedge Tension Clamps are used for fixing the
terminal of the conductor and ground wire
on the tension tower. It bears all or part of the
tension of the conductor and ground wire.

Technical features:
Due to its internal wedge-shaped struc-
ture, it can be pulled more and more
tightly in the line. Thus can meet the re-
quirement of standard holding strength of
95% RTS of the conductor.
www.jiangdong-group.com 53
LINE SYSTEM

Product advantages:
1. The construction is convenient without special tools and instruments, one wrench
can complete the installation;
2. Free maintence of bolt looseness and heating of the jumper plate. Free maintence of
the looseness of the jumper plate during long-term operation.

Suitable diame- Dimensions (mm)


Failure
Catalog No. ter of Conductor
L1 L2 C M load (kN)
(mm)
NX-0512 9.5-12 84 180 18 16 50

NX-0514 12.1-14 84 180 18 16 50

NX-1015 13.1-15 125 300 20 18 100

NX-1017 15.1-17 125 300 20 18 100

NX-1019 17.1-19 125 300 20 18 100

NX-1221 18.1-21 155 450 20 22 120

NX-1224 21.1-24 155 450 20 22 120

NX-1627 24.1-27 155 450 24 24 160

NX-1629 26.1-29 155 450 24 24 160

NX-2130 28.1-30 195 600 24 24 210

NX-2132 30.1-32 195 600 24 24 210

NX-2135 32.1-35 195 600 24 24 210

NX-2537 35.1-37 255 580 28 27 250

NX-2539 37.1-39 255 580 28 27 250

NX-3242 39.1-42 255 580 32 30 320

Remark: *L1, *L2, *C, *M, please refer to related product drawings.

www.jiangdong-group.com 54
LINE SYSTEM

Suspension Clamp

The suspension clamp is primarily


used to fix conductors to
insulator strings or hang lightning
conductors on straight-line
towers, as well as transposition
towers to support conductors,
and tension towers or angle
poles to fix the jumper wires.

www.jiangdong-group.com 55
LINE SYSTEM SUSPENSION CLAMP

Products
Armour Grip Suspension
Clamp For Conductor
Armour Grip Suspension Clamp is primarily used
to fix conductors to insulator strings or hang light-
ning conductors on straight-line towers. Moreo-
ver, it also can be used for transposition towers to
support transposition conductors and for tension
towers or angle poles to fix the jumper wires.

Technical features:
1. The rubber wraps the conductor to form an elastic buffer, which avoids the rigid con-
tact between the suspension clamp and the conductor, ensures the grip strength of
the clamp and effectively eliminates the harmful centripetal pressure;
2. The ARMOR-GRIP Suspension is superior to bolted alternative combinations for
3. protecting conductors from bending, compression stress and abrasion.

Product advantages:
1. The material of clamp is forged aluminum alloy,has high mechanical strength and
strong corrosion resistance;
2. Simple structure, convenient installation, no special tools and maintenance free;
3. Minimal heat transferred to mating hardware and insulators.

Conductor Dia Dimensions (mm) Vertical Failure load


Catalog No.
(mm) C M H (kN)
CL-**** 15.9~22.9 24 18 65 120
CL-**** 18.0~24.9 22 20 70 160
CL-**** 23.9~29.9 26 20 75 160

www.jiangdong-group.com 56
LINE SYSTEM SUSPENSION CLAMP

Conductor Dia Dimensions (mm) Vertical Failure load


Catalog No.
(mm) C M H (kN)
CL-**** 30.0~43.9 36 24 80 210

Remark:
1. *C, *M, *H, please refer to related product drawings;
2. ****: Section of conductor
(AAAC add “LH”; AAC add “L”; ACSR section of AL/STEEL ; ACAR section of AL/AL alloy)
For example: AAAC Flint: Aluminum-Alloy wire 37/3.59 : CL-375LH;
AAC Carnation:Aluminum wire 61/3.891: CL-725L;
ACSR Olive:Aluminum wire -Steel wire 54/3.5-7/3.5: CL-520/67;
ACAR 1024.5MCM-30/7:Aluminum-Alloy Wire-Aluminum Wire 30/4.227-7/4.227: CL-410/100

Trunnion Suspension Clamp


Trunnion Suspension Clamp is primarily used to
fix conductors to insulator strings or hang light-
ning conductors on straight-line towers. Moreo-
ver, it also can be used for transposition towers
to support transposition conductors and for ten-
sion towers or angle poles to fix the jumper wires.

Technical features:
The rotating shaft of the clamp and con-
ductor are on the same axis, the rotation
is flexible.

Product advantages:
1. It has the characteristics of large grip force and flexible rotation;
2. It has the characteristics of high strength, light weight;
3. The surface is polished, smooth without burrs.

Conductor Dia Dimensions (mm) Vertical Failure load


Catalog No.
(mm) H L R C M (kN)
PSC-30 18.0~30.0 116 217 15 24 16 80

www.jiangdong-group.com 57
LINE SYSTEM SUSPENSION CLAMP

Conductor Dia Dimensions (mm) Vertical Failure load


Catalog No.
(mm) H L R C M (kN)
PSC-45 30.0~45.0 120 267 22.5 24 16 100
XGZ-7 45.0~54.0 160 360 27 27 20 120

Remark:
1. *H, *L, *R, *C, *M, please refer to related product drawings;
2. Suitable Dia=Conductor Dia+2*Armour Rods Dia;
3. Usually, armour rods should be used in Suspension String, jumper String is unnecessary to use;
4. Armour Rods Dia will be customized for different conductor.

Envelope Type Suspension Clamp


Envelope Type Suspension clamp is primar-
ily used to fix conductors to insulator strings
or hang lightning conductors on straight-
line towers. Moreover, it also can be used
for transposition towers to support trans-
position conductors and for tension tow-
ers or angle poles to fix the jumper wires.

Technical features:
The body and keeper are made of aluminum alloy, the hanging point is located above
the conductor axis.

Product advantages:
1. It has the characteristics of high strength, light weight;
2. It has the characteristics of simple structure, convenient installation;
3. The surface is polished, smooth without burrs.

www.jiangdong-group.com 58
LINE SYSTEM SUSPENSION CLAMP

Conductor Dia Dimensions (mm) Vertical Failure load


Catalog No.
(mm) H L R C M (kN)
XGF-4X 20.2~25.0 129 300 14 20 16 60
XGF-5X 24.2~33.0 130 300 17 20 16 60
XGF-6X 34.0~43.0 157 300 23 20 18 90

Remark:
1. *H, *L, *R, *C, *M, please refer to related product drawings;
2. Suitable Dia=Conductor Dia+2*Armour Rods Dia;
3. Usually, armor rods be used in Suspension String, unnecessary be used in Jumper String;
4. Armour Rods Dia will be customized for different conductor.

www.jiangdong-group.com 59
LINE SYSTEM

Insulator

Insulator plays the role of electrical


insulation and mechanical
fixing, and it is an important
component of the power system.

www.jiangdong-group.com 60
LINE SYSTEM INSULATOR

Products
Composite Long Rod Insulator
Composite Long Rod Insulator is composed
of end fittings and composite insulating ma-
terials. It plays the role of electrical insulation
and mechanical fixing. Moreover, it is an im-
portant component of the power system

Technical features:
The creepage distance is provided through
the combined and arranged extended insu-
lating rubber shed. Of which has good insu-
lation performance. It has good mechanical
performance through the crimping of excel-
lent rod materials and fittings.

Product advantages:
1. The connection of the fittings is protected by a zinc layer, ultrasonic monitoring,
computer-controlled coaxial pressure crimping process. The crimping after crimping
is bright as new, and the effect is stable and reliable;
2. The aerodynamically designed silicone rubber shed is applied with the integral
shaping technology of the sheath. Thus to ensure that all creepage distances are ef-
fective under any climate and pollution conditions. And to improve the self-cleaning
ability of the synthetic insulator in the air;
3. The use of ECR high temperature reinforced acid-resistant mandrel;
4. The connection between the fitting and the rod adopts a labyrinth-type waterproof
design. Also adopts an outsourcing glue technology, which greatly improves the
waterproof and anti-seepage performance of the product.

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
10(11) 70 16 310±15 145 350 75 —— 42
10(11)/70
FXBW-
10(11) 100 16 410±15 190 350 75 —— 42
10(11)/100

www.jiangdong-group.com 61
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
35 70 16 650±15 450 1050 230 —— 95
35/70
FXBW-
35 70 16 670±15 450 1050 230 —— 95
35/70
FXBW-
35 100 16 650±15 450 1050 230 —— 95
35/100
FXBW-
35 100 16 670±15 450 1050 230 —— 95
35/100
FXBW-
66 70 16 870±15 700 1900 410 —— 185
66/70
FXBW-
66 100 16 940±15 700 1920 410 —— 185
66/100
FXBW-
66 120 16 940±15 700 1920 410 —— 185
66/120
FXBW-
69 70 16 870±15 700 1900 410 —— 185
69/70
FXBW-
69 100 16 870±15 700 1920 410 —— 185
69/100
FXBW-
69 100 16 940±15 700 1920 410 —— 185
69/100
FXBW-
69 120 16 870±15 700 1920 410 —— 185
69/120
FXBW-
69 120 16 940±15 700 1920 410 —— 185
69/120
FXBW-
110 70 16 1240±15 1000 3300 550 —— 230
110/70
FXBW-
110 70 16 1340±15 1000 3300 550 —— 230
110/70
FXBW-
110 70 16 1440±15 1000 3520 550 —— 230
110/70
FXBW-
110 100 16 1240±15 1000 3300 550 —— 230
110/100
FXBW-
110 100 16 1340±15 1000 3300 550 —— 230
110/100
FXBW-
110 100 16 1440±15 1000 3520 550 —— 230
110/100
www.jiangdong-group.com 62
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
110 120 16 1240±15 1000 3300 550 —— 230
110/120
FXBW-
110 120 16 1340±15 1000 3300 550 —— 230
110/120
FXBW-
110 120 16 1440±15 1000 3520 550 —— 230
110/120
FXBW-
110 160 20 1240±15 1000 3150 550 —— 230
110/160
FXBW-
110 160 20 1340±15 1000 3300 550 —— 230
110/160
FXBW-
110 160 20 1440±15 1000 3600 550 —— 230
110/160
FXBW-
115 70 16 1240±15 1000 3150 550 —— 230
115/70
FXBW-
115 100 16 1240±15 1000 3150 550 —— 230
115/100
FXBW-
115 120 16 1240±15 1000 3150 550 —— 230
115/120
FXBW-
115 160 20 1340±15 1000 3150 550 —— 230
115/160
FXBW-
132 70 16 1240±15 1000 3150 550 —— 230
132/70
FXBW-
132 100 16 1240±15 1000 3150 550 —— 230
132/100
FXBW-
132 120 16 1240±15 1000 3150 550 —— 230
132/120
FXBW-
132 160 20 1340±15 1000 3150 550 —— 230
132/160
FXBW-
220 100 16 2150±30 1900 6300 1000 —— 395
220/100
FXBW-
220 100 16 2240±30 1900 6340 1000 —— 395
220/100
FXBW-
220 100 16 2350±30 1900 6340 1000 —— 395
220/100
FXBW-
220 120 16 2240±30 1900 6340 1000 —— 395
220/120
www.jiangdong-group.com 63
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
220 120 16 2350±30 1900 6340 1000 —— 395
220/120
FXBW-
220 120 16 2350±30 1900 6800 1000 —— 395
220/120
FXBW-
220 120 16 2470±30 1900 7040 1000 —— 395
220/120
FXBW-
220 160 20 2150±30 1900 6300 1000 —— 395
220/160
FXBW-
220 160 20 2240±30 1900 6300 1000 —— 395
220/160
FXBW-
220 160 20 2350±30 1900 6340 1000 —— 395
220/160
FXBW-
220 160 20 2470±30 1900 7040 1000 —— 395
220/160
FXBW-
220 180 20 2560±30 1900 7200 1000 —— 395
220/180
FXBW-
220 210 20 2240±30 1900 6340 1000 —— 395
220/210
FXBW-
220 210 20 2350±30 1900 6340 1000 —— 395
220/210
FXBW-
220 210 20 2470±30 1900 7040 1000 —— 395
220/210
FXBW-
220 240 24 2240±30 1900 6800 1000 —— 395
220/240
FXBW-
220 240 24 2470±30 1900 7040 1000 —— 395
220/240
FXBW-
220 300 24 2350±30 1900 6800 1000 —— 395
220/300
FXBW-
220 300 24 2470±30 1900 7040 1000 —— 395
220/300
FXBW-
230 100 16 2350±30 1900 6340 1000 —— 395
230/100
FXBW-
230 120 16 2350±30 1900 6340 1000 —— 395
230/120
FXBW-
230 160 20 2350±30 1900 6340 1000 —— 395
230/160
www.jiangdong-group.com 64
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
230 210 20 2350±30 1900 6340 1000 —— 395
230/210
FXBW-
330 100 16 2930±40 2600 7260 1425 950 570
330/100
FXBW-
330 100 16 2990±40 2600 9075 1425 950 570
330/100
FXBW-
330 100 16 3150±40 2600 9240 1425 950 570
330/100
FXBW-
330 100 16 3350±40 2600 10560 1425 950 570
330/100
FXBW-
330 120 16 2930±40 2600 9075 1425 950 570
330/120
FXBW-
330 120 16 2990±40 2600 9075 1425 950 570
330/120
FXBW-
330 120 16 3150±40 2600 9240 1425 950 570
330/120
FXBW-
330 120 16 3350±40 2600 10560 1425 950 570
330/120
FXBW-
330 160 20 2930±40 2600 9075 1425 950 570
330/160
FXBW-
330 160 20 2990±40 2600 9200 1425 950 570
330/160
FXBW-
330 160 20 3150±40 2600 9240 1425 950 570
330/160
FXBW-
330 160 20 3350±40 2600 10560 1425 950 570
330/160
FXBW-
330 180 20 2930±40 2600 9075 1425 950 570
330/180
FXBW-
330 180 20 2990±40 2600 9200 1425 950 570
330/180
FXBW-
330 180 20 3350±40 2600 10560 1425 950 570
330/180
FXBW-
330 210 20 2930±40 2600 9075 1425 950 570
330/210
FXBW-
330 210 20 2990±40 2600 9075 1425 950 570
330/210
www.jiangdong-group.com 65
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
330 210 20 3150±40 2600 9240 1425 950 570
330/210
FXBW-
330 210 20 3350±40 2600 10560 1425 950 570
330/210
FXBW-
330 240 24 2930±40 2600 9800 1425 950 570
330/240
FXBW-
330 240 24 2990±40 2600 10000 1425 950 570
330/240
FXBW-
330 240 24 3350±40 2600 10560 1425 950 570
330/240
FXBW-
330 300 24 2990±40 2600 9800 1425 950 570
330/300
FXBW-
330 300 24 3350±40 2600 10560 1425 950 570
330/300
FXBW-
345 100 16 3690±40 3400 11300 1425 950 570
345/100
FXBW-
345 120 16 3690±40 3400 11300 1425 950 570
345/120
FXBW-
345 160 20 3750±40 3400 11300 1425 950 570
345/160
FXBW-
345 210 20 3800±40 3400 11300 1425 950 570
345/210
FXBW-
400 120 16 3335±40 3040 13020 1550 1050 680
400/120
FXBW-
400 160 20 3910±40 3580 13020 1550 1050 680
400/160
FXBW-
400 210 20 3910±40 3520 13020 1550 1050 680
400/210
FXBW-
400 300 24 3910±40 3440 13020 1550 1050 680
400/300
FXBW-
500 100 16 4030±50 3600 12000 2050 1240 740
500/100
FXBW-
500 100 16 4450±50 4000 14000 2250 1240 740
500/100
FXBW-
500 100 16 4900±50 4000 15000 2250 1240 740
500/100
www.jiangdong-group.com 66
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
500 120 16 4030±50 3600 12000 2050 1240 740
500/120
FXBW-
500 120 16 4450±50 4000 14000 2250 1240 740
500/120
FXBW-
500 120 16 4900±50 4000 15000 2250 1240 740
500/120
FXBW-
500 160 20 4030±50 3600 12000 2050 1240 740
500/160
FXBW-
500 160 20 4450±50 4000 14000 2250 1240 740
500/160
FXBW-
500 160 20 4900±50 4000 15000 2250 1240 740
500/160
FXBW-
500 180 20 4030±50 3600 12000 2050 1240 740
500/180
FXBW-
500 180 20 4450±50 4000 14000 2250 1240 740
500/180
FXBW-
500 180 20 4900±50 4000 15000 2250 1240 740
500/180
FXBW-
500 210 20 4030±50 3600 12000 2050 1240 740
500/210
FXBW-
500 210 20 4450±50 4000 14000 2250 1240 740
500/210
FXBW-
500 210 20 4900±50 4000 15000 2250 1240 740
500/210
FXBW-
500 240 20 4030±50 3600 13750 2050 1240 740
500/240
FXBW-
500 240 20 4450±50 4000 14000 2250 1240 740
500/240
FXBW-
500 240 20 4900±50 4000 16000 2250 1240 740
500/240
FXBW-
500 300 24 4030±50 3600 13750 2050 1240 740
500/300
FXBW-
500 300 24 4450±50 4000 14000 2250 1240 740
500/300

www.jiangdong-group.com 67
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
500 300 24 4900±50 4000 16000 2250 1240 740
500/300
FXBW-
500 400 28 4450±50 4000 14000 2250 1240 740
500/400
FXBW-
500 400 28 4900±50 4000 16000 2250 1240 740
500/400
FXBW-
500 420 28 4450±50 4000 14000 2250 1240 740
500/420
FXBW-
500 420 28 4900±50 4000 16000 2250 1240 740
500/420
FXBW-
500 530 32 4600±50 4000 14000 2250 1240 740
500/530
FXBW-
500 530 32 4900±50 4000 16000 2250 1240 740
500/530
FXBW-
500 550 32 4600±50 4000 14000 2250 1240 740
500/550
FXBW-
500 550 32 4900±50 4000 16000 2250 1240 740
500/550
FXBW-
750 120 16 7150±50 6000 23500 2700 1800 1125
750/120
FXBW-
750 120 16 7350±50 6000 24150 2700 1800 1125
750/120
FXBW-
750 160 20 7150±50 6000 23500 2700 1800 1125
750/160
FXBW-
750 160 20 7350±50 6000 24150 2700 1800 1125
750/160
FXBW-
750 180 20 7150±50 6000 23500 2700 1800 1125
750/180
FXBW-
750 180 20 7350±50 6000 24150 2700 1800 1125
750/180
FXBW-
750 210 20 7150±50 6000 23500 2700 1800 1125
750/210
FXBW-
750 210 20 7350±50 6000 24150 2700 1800 1125
750/210

www.jiangdong-group.com 68
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
750 240 20 6550±50 6000 23500 2700 1800 1125
750/240
FXBW-
750 300 24 6550±50 6000 23500 2700 1800 1125
750/300
FXBW-
750 300 24 7150±50 6000 23500 2700 1800 1125
750/300
FXBW-
750 300 24 7350±50 6000 24150 2700 1800 1125
750/300
FXBW-
750 400 28 6550±50 6000 23500 2700 1800 1125
750/400
FXBW-
750 400 28 7150±50 6000 23500 2700 1800 1125
750/400
FXBW-
750 400 28 7350±50 6000 24150 2700 1800 1125
750/400
FXBW-
750 420 28 6550±50 6000 23500 2700 1800 1125
750/420
FXBW-
750 420 28 7150±50 6000 23500 2700 1800 1125
750/420
FXBW-
750 420 28 7350±50 6000 24150 2700 1800 1125
750/420
FXBW-
750 530 32 6550±50 6000 23500 2700 1800 1125
750/530
FXBW-
750 530 32 7150±50 6000 23500 2700 1800 1125
750/530
FXBW-
750 530 32 7350±50 6000 24150 2700 1800 1125
750/530
FXBW-
750 550 32 6550±50 6000 23500 2700 1800 1125
750/550
FXBW-
750 550 32 7150±50 6000 24150 2700 1800 1125
750/550
FXBW-
750 550 32 7350±50 6000 27000 2700 1800 1125
750/550
FXBW-
1000 160 20 9000±50 8000 32000 3600 2200 1450
1000/160

www.jiangdong-group.com 69
LINE SYSTEM INSULATOR

Dry Wet Wet


lightning
Specified Dry Minimum switching power
Rated Cou- impulse
mechan- Length arcing creepage with- frequency
Type voltage pling with-
ical load (mm) distance distance stand withstand
(kV) size stand
(kN) (mm) (L/mm) voltage voltage
voltage (kV) (kV)
(kV)
FXBW-
1000 160 20 9750±50 9000 36000 3600 2200 1450
1000/160
FXBW-
1000 180 20 9000±50 8000 32000 3600 2200 1450
1000/180
FXBW-
1000 180 20 9750±50 9000 36000 3600 2200 1450
1000/180
FXBW-
1000 210 20 9000±50 8000 32000 3600 2200 1450
1000/210
FXBW-
1000 210 20 9750±50 9000 36000 3600 2200 1450
1000/210
FXBW-
1000 240 20 9000±50 8000 32000 3600 2200 1450
1000/240
FXBW-
1000 240 20 9750±50 9000 36000 3600 2200 1450
1000/240
FXBW-
1000 300 24 9000±50 8000 32000 3600 2200 1450
1000/300
FXBW-
1000 300 24 9750±50 9000 36000 3600 2200 1450
1000/300
FXBW-
1000 400 28 9000±50 8000 32000 3600 2200 1450
1000/400
FXBW-
1000 400 28 9750±50 9000 36000 3600 2200 1450
1000/400
FXBW-
1000 420 28 9000±50 8000 32000 3600 2200 1450
1000/420
FXBW-
1000 420 28 9750±50 9000 36000 3600 2200 1450
1000/420
FXBW-
1000 530 32 9000±50 8000 32000 3600 2200 1450
1000/530
FXBW-
1000 530 32 9750±50 9000 36000 3600 2200 1450
1000/530
FXBW-
1000 550 32 9000±50 8000 32000 3600 2200 1450
1000/550
FXBW-
1000 550 32 9750±50 9000 36000 3600 2200 1450
1000/550

www.jiangdong-group.com 70
LINE SYSTEM

Glass Insulator
Glass Insulator is a device used to support
and insulate wires. Its main material is glass.

Technical features:
It is made of tempered glass and pro-
vides creepage distance by extending
the shed. Other main components are
steel caps and pins.

Product advantages:
1. Glass insulator has good electron-mechanical performance;
2. It has the characteristics of zero value self explosion, which can reduce a large num-
ber of zero value detection and other operation and maintenance work;
3. Its service life cycle is long.
Lighting Impulse Withstand

Radio Interference Voltage


Mechanical Routine Test
Mechanical Failing Load

Power Frequency With-

Power Frequency With-

Min Power Frequency


Creepage Distance *L

stand Voltage (WET)


stand Voltage (DRY)

Corona Test (pin&cap)


Puncture Voltage
Insulator type(IEC)

Size of Coupling
Diameter *D

(10kV,1MHz)
Spacing *H

Voltage

U70BL/146 255 146 320 16 70 35 70 40 100 130 ≤50 18/22

U70BS/127 255 127 320 16 70 35 70 40 100 130 ≤50 18/22

U100BL/146 255 146 320 16 100 50 70 40 100 130 ≤50 18/22

U100BS/127 255 127 320 16 100 50 70 40 100 130 ≤50 18/22

U120B/146 255 146 320 16 120 60 70 40 100 130 ≤50 18/22

U120B/127 255 127 320 16 120 60 70 40 100 130 ≤50 18/22

U160BL/170 280 170 400 20 160 80 75 45 110 130 ≤50 18/22

www.jiangdong-group.com 71
LINE SYSTEM INSULATOR

Lighting Impulse Withstand

Radio Interference Voltage


Mechanical Routine Test
Mechanical Failing Load

Power Frequency With-

Power Frequency With-

Min Power Frequency


Creepage Distance *L

stand Voltage (WET)


stand Voltage (DRY)

Corona Test (pin&cap)


Puncture Voltage
Insulator type(IEC)

Size of Coupling
Diameter *D

(10kV,1MHz)
Spacing *H

Voltage
U160B/155 280 155 450 20 160 80 75 45 110 130 ≤50 18/22

U160B/155 280 155 400 20 160 80 75 45 110 130 ≤50 18/22

U160BS/146 280 146 400 20 160 80 75 45 110 130 ≤50 18/22

U210B/170 280 170 460 20 210 105 85 45 125 130 ≤50 18/22

U210B/170 280 170 400 20 210 105 75 45 110 130 ≤50 18/22

U240B/170 280 170 400 24 240 120 75 45 110 130 ≤50 18/22

U240B/170 280 170 460 24 240 120 85 50 110 130 ≤50 18/22

U300B/195 320 195 485 24 300 150 85 50 130 130 ≤50 18/22

U420/205 360 205 550 28 420 210 90 55 140 130 ≤50 18/22

Remark: *D, *H, *L, please refer to related product drawings.

www.jiangdong-group.com 72
LINE SYSTEM

Arrester

Surge arrester is also called


overvoltage protector and
overvoltage limiter. It is connected
in parallel to the front end of the
protected equipment to protect
other electrical equipment from
lightning overvoltage, operating
overvoltage and power frequency
transient overvoltage impact.

www.jiangdong-group.com 73
LINE SYSTEM ARRESTER

Products
High Voltage Line with Gap Arrester
Surge arrester is also called over-voltage pro-
tector and over-voltage limiter. It is connect-
ed in parallel to the front end of the protected
equipment to protect other electrical equip-
ment. In case they are damaged from lightning
over-voltage, operating over-voltage, and pow-
er frequency transient over-voltage impact.

Technical features:
High Voltage Line With Gap Arrester is mainly composed of insulating housing (compos-
ite or ceramic material), resistor, end accessories, and composite insulator gap.

Product advantages:
1. The resistors are manufactured with high-quality raw materials and strict process-
es. The comprehensive performance of the resistors has reached China’s advanced
level. Especially the current capacity, high current impact and residual voltage ratio
performance have reached China’s leading level.
2. The use of duration encapsulating materials or epoxy composite casing fundamen-
tally solves the problem of product failure caused by moisture intrusion. Even in a
high temperature environment with a humidity of more than 90%, there will not be
any failures.
3. Silicone rubber material is highly hydrophobic, it can prevent rainwater from form-
ing continuous channels and prevent any pollutants from accumulating during use.
Make the product corrosion resistant and cut off the leakage current path. Moreover,
the flame retardant and self-extinguishing properties of the material can realize the
product cleaning-free function.

www.jiangdong-group.com 74
LINE SYSTEM ARRESTER

System voltage 110kV 220kV 330kV 500kV

YH20CX-396/1050

YH20CX-396/1050
YH10CX-204/592

YH10CX-288/775
YH10CX-108/320
YH10CX-102/296

YH10CX-192/560
Type

Electric pa-
Rated voltage UR (kV) 102 108 192 204 288 396
rameters

Electric pa- 1mA DC reference volt-


148 160 280 296 408 561
rameters age U1mA (kV)

Electric pa- Nominal discharge cur-


10 10 10 10 10 20
rameters rent (kA)

Electric pa- Steep current impulse


331 358 628 662 817 1171
rameters residual voltage(kV)

Electric pa- Lightning impulse resid-


296 320 560 592 775 1050
rameters ual voltage (kV)

Electric pa- Square wave impulse 500/ 500/ 600/ 600/ 800/ 1200/
rameters withstand Current (A) 600 600 800 800 1200 1800

Electric pa- High Current impulse


100 100 100 100 100 100
rameters withstand Current (kA)

Electric pa- Power frequency dis-


185 185 370 370 510 567
rameters charge voltage(kV)

Electric pa- Impulse discharge volt-


525 525 900 900 1300 1760
rameters age(kV)

Structural
Overall height H (mm) 1256 1256 3783 3783 4757 6971
parameters

Structural Cree-page distance


3946 3946 8018 8018 11526 17289
parameters (mm)

Structural
Shed diameter Φ (mm) 195 195 195 195 252 252
parameters

www.jiangdong-group.com 75
LINE SYSTEM

Conductor

Conductor Type:
• AAC-All Aluminum Conductors
• AAAC -All Aluminum Alloy Conductors
• ACSR- Aluminum Conductors Steel Reinforced
• ACSR/AW -Aluminum Conductors
Aluminum Clad Steel Reinforced
• ACAR-All Aluminum Conductor Alloy Reinforced
• AACSR-Aluminum Alloy Conductors Steel Reinforced
• GSW-Zinc-Coated (Galvanized) Steel
Overhead Ground Wire Strand
• ACS-aluminum-clad steel conductors

www.jiangdong-group.com 76
LINE SYSTEM CONDUCTOR

Products
Conductor

Technical details:
Invar Conductor made is a kind of special overhead conductor stranded with high-
strength aluminum-clad invar core and super thermal resistant aluminum alloy wire. It
takes advantage of the low linear expansion coefficient of invar material to make “low
sag” and uses a thermal resistant aluminum alloy to have “ large-capacity”, making full
use of original transmission line and tower resources and saving space. It has the feature
of doubling capacity with the same diameter and the same sag, which can ensure power
transmission at peak season.

Characteristics:
• 2 times current carrying capacity without increasing sag.
• More economical for fittings.
• Easier installation than ACCC Conductor.
• More reliable operation experience.
• In compliance with or exceeding the industry’s most stringent requirements, including:
• IEC 62004
• IEC 61089
• IEC 62219
• Q/320623-AP25

www.jiangdong-group.com 77
LINE SYSTEM

Typical Parameters (Trapezoid structure)

DC
Structure Current capacity
Diam- Breaking resis-
Areas Weight
eter load tance at
Code
Al Steel 20ºC TACIR ZTACIR

Nos./mm mm2 mm kN Ω/km Kg/km A

160/40 18/3.37 7/2.65 199.16 17.04 65.06 0.1759 730 771 957

200/45 17/3.87 7/2.85 244.62 18.87 76.87 0.1412 883 890 1105

200/50 17/3.87 7/2.95 247.81 19.01 80.39 0.1409 906 892 1110

250/45 18/4.20 7/2.85 294.04 20.64 82.64 0.1141 1019 1017 1268

250/40 18/4.13 7/2.75 290.96 20.51 81.12 0.1143 996 1014 1264

240/55 18/4.13 7/3.20 297.43 20.82 93.12 0.1169 1083 1007 1138

240/50 18/4.71 7/3.00 290.62 20.55 88.13 0.1157 1032 1000 1131

315/55 18/4.71 7/3.20 396.92 23.15 104.06 0.0907 1266 1182 1479

315/50 18/4.71 7/3.00 363.10 22.91 97.20 0.0910 1232 1176 1471

330/60 18/4.81 7/3.30 386.95 23.68 109.70 0.0869 1329 1216 1522

350/55 20/4.71 7/3.20 404.77 24.19 109.33 0.0819 1379 1262 1580

Overseas References

Country Total Length


USA 2600km
Finland 2130km
Chile 6800km
Peru 5000km
Thailand 5200km
Malaysia 9000km
Kenya 1700km
Nigeria 600km
Saudi Arabia 2100km
Indonesia 800km

www.jiangdong-group.com 78