You are on page 1of 7

Station Pt (Pa) Tt (K)

Ambiant Pamb/Tamb 100000 300


Fan inlet P1/T1 142961 332
Fan outlet P2/T2 200145 410
Nozzle Ve (m/s) = 439
Station Pt (Pa) Tt (K)
GG inlet P2/T2 200145 410
Combustion inlet P3/T3 4002908 1062
Combustion outlet P4/T4 3922850 1850
HP Turbine outlet T5/P5 856345 1125
LP turbine outlet T6/P6 510063 219
Cold nozzle Ve (m/s) = 569
M0.8
1bar, 27°C
Pt=Pamb + 1/2 rho V² , Ttt/Tamb=(Pt/Pamb)^((gamma-1)/gamma)
FPR=1.4, if adiabatic : T2ad/T1=FPR^(0.4/1.4) , as efficiency 0.94 : (T2-T1) = (T2ad-T1)/0.94
Ve = sqrt((P2-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T2=(Pamb/P2)^(0.4/1.4)

0.85 efficiency : (T2-T1) = (T2ad-T1)/0.85 ; PR = 20


T4 = 1450K for uncooled turbine (1700 to 1850K for cooled turbines) ; 2% pressure drop
0.9 efficiency : (T4-T5) = (T3-T2)/0.9 ; T5ad = T4-0.9*(T4-T5) = T4-T3+T2
0.94 efficiency : (T5-T6) = (T2-T1).(1+BPR)/0.94
Ve = sqrt((P6-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T6=(Pamb/P6)^(0.4/1.4)
Station Pt (Pa) Tt (K)
Ambiant Pamb/Tamb 100000 300
Fan inlet P1/T1 142961 332
Fan outlet P2/T2 285922 413
Nozzle Ve (m/s) = 571
Station Pt (Pa) Tt (K)
GG inlet P2/T2 285922 413
Combustion inlet P3/T3 2573298 960
Combustion outlet P4/T4 2521832 1800
HP Turbine outlet T5/P5 709704 1192
LP turbine outlet T6/P6 426104 1013
Cold nozzle Ve (m/s) = 1119
1400K nozzle Ve (m/s) = 1316

Station Pt (Pa) Tt (K)


Ambiant Pamb/Tamb 100000 300
Fan inlet P1/T1 142961 332
Fan outlet P2/T2 285922 413
Nozzle Ve (m/s) = 571
Station Pt (Pa) Tt (K)
GG inlet P2/T2 285922 413
Combustion inlet P3/T3 2573298 960
Combustion outlet P4/T4 2521832 1550
HP Turbine outlet T5/P5 549657 942
LP turbine outlet T6/P6 284372 763
Cold nozzle Ve (m/s) = 774
1400K nozzle Ve (m/s) = 1048

0.51763009
M0.8
1bar, 27°C
Pt=Pamb + 1/2 rho V² , Ttt/Tamb=(Pt/Pamb)^((gamma-1)/gamma)
FPR=2, if adiabatic : T2ad/T1=FPR^(0.4/1.4) , as efficiency 0.9 : (T2-T1) = (T2ad-T1)/0.9
Ve = sqrt((P2-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T2=(Pamb/P2)^(0.4/1.4)

0.85 efficiency : (T2-T1) = (T2ad-T1)/0.85


T4 = 1450K for uncooled turbine (1700 to 1850K for cooled turbines) ; 2% pressure drop
0.9 efficiency : (T4-T5) = (T3-T2)/0.9 ; T5ad = T4-0.9*(T4-T5) = T4-T3+T2
0.9 efficiency : (T5-T6) = (T2-T1).(1+1)/0.9
Ve = sqrt((P6-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T6=(Pamb/P6)^(0.4/1.4)
here, Ts/1400=(Pamb/P6)^(0.4/1.4)

M0.8
1bar, 27°C
Pt=Pamb + 1/2 rho V² , Ttt/Tamb=(Pt/Pamb)^((gamma-1)/gamma)
FPR=2, if adiabatic : T2ad/T1=FPR^(0.4/1.4) , as efficiency 0.9 : (T2-T1) = (T2ad-T1)/0.9
Ve = sqrt((P2-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T2=(Pamb/P2)^(0.4/1.4)

0.85 efficiency : (T2-T1) = (T2ad-T1)/0.85


T4 = 1450K for uncooled turbine (1700 to 1850K for cooled turbines) ; 2% pressure drop
0.9 efficiency : (T4-T5) = (T3-T2)/0.9 ; T5ad = T4-0.9*(T4-T5) = T4-T3+T2
0.9 efficiency : (T5-T6) = (T2-T1).(1+1)/0.9
Ve = sqrt((P6-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T6=(Pamb/P6)^(0.4/1.4)
here, Ts/1400=(Pamb/P6)^(0.4/1.4)
Fan Station Pt (Pa) Tt (K)
Ambiant Pamb/Tamb 100000 300
Fan inlet P1/T1 196662 364
Fan outlet P2/T2 393325 453
Nozzle Ve (m/s) = 718
Core Station Pt (Pa) Tt (K)
GG inlet P2/T2 393325 453
Combustion inlet P3/T3 3539921 1052
Combustion outlet P4/T4 3469122 1800
HP Turbine outlet T5/P5 841238 1134
LP turbine outlet T6/P6 464311 937
Cold nozzle Ve (m/s) = 1124
1400K nozzle Ve (m/s) = 1374

Fan Station Pt (Pa) Tt (K)


Ambiant Pamb/Tamb 100000 300
Fan inlet P1/T1 196662 364
Fan outlet P2/T2 393325 453
Fan afterburning 393325 1400
Nozzle Ve (m/s) = 1263
Core Station Pt (Pa) Tt (K)
GG inlet P2/T2 393325 453
Combustion inlet P3/T3 3539921 1052
Combustion outlet P4/T4 3469122 1800
HP Turbine outlet T5/P5 841238 1134
LP turbine outlet T6/P6 464311 937
Cold nozzle Ve (m/s) = 1124
1400K nozzle Ve (m/s) = 1374
M1.2
1bar, 27°C
Pt=Pamb + 1/2 rho V² , Ttt/Tamb=(Pt/Pamb)^((gamma-1)/gamma)
FPR=2, if adiabatic : T2ad/T1=FPR^(0.4/1.4) , as efficiency 0.9 : (T2-T1) = (T2ad-T1)/0.9
Ve = sqrt((P2-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T2=(Pamb/P2)^(0.4/1.4)

0.85 efficiency : (T2-T1) = (T2ad-T1)/0.85


T4 = 1450K for uncooled turbine (1700 to 1850K for cooled turbines) ; 2% pressure drop
0.9 efficiency : (T4-T5) = (T3-T2)/0.9 ; T5ad = T4-0.9*(T4-T5) = T4-T3+T2
0.9 efficiency : (T5-T6) = (T2-T1).(1+1)/0.9
Ve = sqrt((P6-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T6=(Pamb/P6)^(0.4/1.4)
here, Ts/1400=(Pamb/P6)^(0.4/1.4)

M1.2
1bar, 27°C
Pt=Pamb + 1/2 rho V² , Ttt/Tamb=(Pt/Pamb)^((gamma-1)/gamma)
FPR=2, if adiabatic : T2ad/T1=FPR^(0.4/1.4) , as efficiency 0.9 : (T2-T1) = (T2ad-T1)/0.9

Ve = sqrt((P2-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/1400=(Pamb/P2)^(0.4/1.4)

0.85 efficiency : (T2-T1) = (T2ad-T1)/0.85


T4 = 1450K for uncooled turbine (1700 to 1850K for cooled turbines) ; 2% pressure drop
0.9 efficiency : (T4-T5) = (T3-T2)/0.9 ; T5ad = T4-0.9*(T4-T5) = T4-T3+T2
0.9 efficiency : (T5-T6) = (T2-T1).(1+1)/0.9
Ve = sqrt((P6-Pamb)/0.5rho), to determine rho : Ps=Pamb, Ts/T6=(Pamb/P6)^(0.4/1.4)
here, Ts/1400=(Pamb/P6)^(0.4/1.4)
M0.8 M1.2 M0.8
Station Pt (Pa) Tt (K) Pt (Pa) Tt (K) Pt (Pa) Tt (K)
Ambiant Pamb/Tamb 100000 300 100000 300 100000 300
Fan inlet P1/T1 142961 332 196662 364 142961 332
Fan outlet P2/T2 285922 413 393325 453 285922 413

Nozzle Ve (m/s) = 571 Ve (m/s) = 718 Ve (m/s) = 571


Station Pt (Pa) Tt (K) Pt (Pa) Tt (K) Pt (Pa) Tt (K)
GG inlet P2/T2 285922 413 393325 453 285922 413
Combustion inlet P3/T3 2573298 960 3539921 1052 2573298 960
Combustion outlet P4/T4 2521832 1800 3469122 1800 2521832 1540
HP Turbine outlet T5/P5 709704 1192 841238 1134 542874 932
LP turbine outlet T6/P6 426104 1013 464311 937 278684 753
Cold nozzle Ve (m/s) = 1119 Ve (m/s) = 1124 Ve (m/s) = 759
1200K afterburning Ve (m/s) = 1272
cold 573 cold 513 cold 393
T/q (kN/kg)
afterburned 587
44% 58% 57%
Etaprop
47%