F2

TCI INS
cable number note cable number note cable number note

CC

CB
CA

cable number note cable number note cable number note

HC
HB
HA

TB

TA1 TA2
CN6 Plug
CN7 Plug

CN2 Plug
Plug
CN8 Plug

Plug

Note:
The encoder signal line must be laid separately from the main circuit and other power lines,(If it allows, encoder wire can be weared in
the pipe alone), Close parallel lines are prohibited,The connection of the encoder must adopt shielding wire to ensure that the shielding layer
at the side of the motor is suspended;If the user's ground wire is reliable and meets relevant requirements, connect one end of the encoder
line shielding layer (control cabinet side) to PE, and the other end is suspended;If the user's ground wire is unstable or does not meet the
relevant requirements, connect the encoder line shielding layer (control cabinet side) to PGM.For the synchronous tractor, the user is
recommended to select the SIN/COS encoder.
switch

( )

( )

Instalation instruction,
The special power box of the interphone is recommended to be
installed on the top of the car
TOP
MACHINE
CAR PIT MONITOR ROOM
PHONE PHONE PHONE PHONE
CAR PHONE
DOOR
CONTROLER
19 12

串行通讯板
楼按钮 楼按钮
HB
AMP- 48076-0

RNBS2-5 HA
AMP-48078-0

SNBS1-4

Remark :1.Shaft switch cable HA plug, standard cable is RVV6*0.75 (6 cores Cable )
2.Shaft switch HA Plug, if increase second grade deceleration switch, use RVV8*0.75 (8cores
cable), just as the list shows.
3.Shaft Cable length:hoisting height +6M (without machine room)
4.Shaft Cable: hoisting height +10M (with machine room)

CN10
AMP-171892-1

25 22

井道固定电缆
RNBS2-5

SNBS1-4

25 22

井道固定电缆