You are on page 1of 11

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 11

STREETLIGHT PHOTOMETRIC TEST REPORT

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

DATA OF LAMP PHOTOMETRIC DATA Eff: 173.88 lm/W


MODEL Imax(cd) 19792 h street_up(%) 0.0
NOMINAL POWER(W) LOR(%) 100.0 h street_down(%) 54.8
RATED VOLTAGE(V) 220 TOTAL FLUX(lm) 34456 h house_up(%) 0.0
NOMINAL FLUX(lm) 34455.7 MAXIMUM @(C,g ) 225,36.0 h house_down(%) 45.2
LAMPS INSIDE 1 h up(%) 0.0 76 FLASHAREA(m2) 0.00100
TEST VOLTAGE(V) 0 h down(%) 100.0 SLI 19.401

INTENSITY DISTRIBUTION DIAGRAM MAX INTENSITY CONE SURFACE


IN C PLANS DISTRIBUTION DIAGRAM

C180 HOUSE SIDE


-/+180
C210 C150
-150 150

-120 120 C240 C120

-90 0 90 C270 0 C90


4000
4000
8000
8000
-60 12000 60
UNIT:cd C300 12000 C60
16000 C0/180,88.7
C30/210,93.7 16000
-30 20000 30 C60/240,92.4
0 C90/270,86.6 C330 C30
AVERAGE BEAM ANGLE(50%):90.3 DEG 20000
C0
Max @ g = 36.0DEG STREET SIDE

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 11

STREETLIGHT ISOCANDELA DIAGRAM

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

180 170
160
Classification:
150

140 IES:Type VS - Very Short


CIE:Narrow - Short
130 IES:Cut-off
CIE:Full cut-off
Max.At80:15.03cd/klm
120
Max.At90:9.825cd/klm
Max.80-90:18.85cd/klm
110
ISOCANDELA DIAGRAM

100 UNIT cd

Imax=100% 19792
270 285 300 315 330 345 C0 15 30 45 60 75 90
90 90% 17813

80% 15833
80 70% 13854

60% 11875
70
50% 9896

60 40% 7917

30% 5938
50
20% 3958
40
10% 1979
30
5% 990
20
g0 10

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 11

COEFFICIENT OF UTILIZATION CURVE


AND ISOLUX DIAGRAM

CU(%) STREETLIGHT COEFFICIENT OF UTILIZATION CURVE


100
TILT ANGLE
0.0(DEG)
90
5.0(DEG)
80 10.0(DEG)
15.0(DEG)
70 20.0(DEG)

60

50

40

30

20

10

0
2 1 0 1 2 3 4
HOUSE SIDE STREET SIDE RATIO OF DISTANCE TO MOUNTING HEIGHT

ROAD SURFACE ISOLUX DIAGRAM


ILLUMINANCE AT MH=10 m,Enadir = 160.49 lx
HOUSE SIDE

TO CONVERT TO OTHER MH,MULTIPLY BY FACTOR IN THE TABLE.


1
HEIGHT FACTOR
5 m 4.000
0
6 m 2.778

1 7 m 2.041
D/MH

8 m 1.563
2 9 m 1.235
STREET SIDE

10 m 1.000
3 11 m 0.826
12 m 0.694
4-7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 13 m 0.592
RATIO OF DISTANCE TO MOUNTING HEIGHT
14 m 0.510
130 96 80 64 48
15 m 0.444
16 8 4.8 1.6 0.8
16 m 0.391

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 11

ZONAL FLUX DIAGRAM

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

g C0 C45 C90 C135 C180 C225 C270 C315 g F zone F total %lum,lamp

10 1633 1616 1605 1613 1674 1666 1611 1576 0- 10 1530 1530 4.44,4.44

20 1685 1702 1676 1743 1710 1741 1633 1637 10- 20 4694 6224 18.1,18.1

30 1648 1810 1738 1895 1644 1845 1664 1815 20- 30 7987 14212 41.2,41.2

40 1522 1922 1430 1756 1347 1833 1215 1775 30- 40 10873 25084 72.8,72.8

50 212.5 583.8 127.3 370.9 170.3 267.2 110.2 408.3 40- 50 6907 31991 92.8,92.8

60 78.54 118.2 74.88 107.8 70.32 78.88 67.31 103.0 50- 60 1307 33298 96.6,96.6

70 36.25 55.63 51.64 47.89 31.32 40.28 54.82 46.94 60- 70 602.3 33900 98.4,98.4

80 37.13 23.23 49.25 21.33 33.51 20.32 51.79 22.98 70- 80 342.9 34243 99.4,99.4

90 4.238 8.792 33.85 6.169 2.841 4.855 11.36 6.375 80- 90 212.5 34456 100,100

100 90-100

110 100-110

120 110-120

130 120-130

140 130-140

150 140-150

160 150-160

170 160-170

180 170-180

DEG LUMINOUS INTENSITY:×10cd UNIT:lm

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 11

ISOCANDELA DIAGRAM

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

90 5% 988.7
10% 1977
80 15% 2966
20% 3955
70 25% 4943
30% 5932
60 35% 6921
40% 7909
50 45% 8898
50% 9887
40 55% 10876
60% 11864
30 65% 12853
70% 13842
20 75% 14830
VERTICAL(DEG)

80% 15819
10 85% 16808
90% 17796
0 95% 18785

-10

-20

-30 1. AVG=15970,MIN=15642
2. AVG=16020,MIN=15585
-40 3. AVG=16068,MIN=15585

-50

-60

-70
Imax:19774(H-25.0,V27.5)
-80 (At:C=225.0,Gamma=36.0)
UNIT: cd
-90
-90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90
HORIZONTAL(DEG)

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 11

Planar Illuminance Curve

Planar Illuminance Curve


E(lx) MH = 10 m
200

C0/180

180 C90/270

160

140

120

100

80

60

40

20

0
-25 -20 -15 -10 -5 0 5 10 15 20 25
Distance(m)

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 11

LCS REPORT

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

LUMINAIRE CLASSIFICATION SYSTEM(LCS) GRAPH


Uplight
15000(lm)

12000

9000

6000

100 3000 100

90 90

80 80

60 60

Back Front
30 30

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 11

BUG REPORT

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

IESNA Luminaire Flux Distribution Table:


Zone Lumens Luminaire %
FL - Front-Low(0-30) 7595.6 22.0
FM - Front-Medium(30-60) 10593 30.7
FH - Front-High(60-80) 544.1 1.6
FVH - Front-Very High(80-90) 133.8 0.4
Total Forward Light 18867 54.8

BL - Back-Low(0-30) 6616 19.2


BM - Back-Medium(30-60) 8493 24.6
BH - Back-High(60-80) 401.14 1.2
BVH - Back-Very High(80-90) 78.702 0.2
Total Back Light 15589 45.2

UL - Uplight-Low(90-100) 0 0.0
UH - Uplight-High(100-180) 0 0.0
Total Up Light 0 0.0

BUG(Back,Up,Glare) Rating B5-U0-G2

Zone Downward Upward Total


Lumens Lumens Lumens
House Side 15589 0 15589
Street Side 18867 0 18867

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 11

ROAD ISOCANDELA REPORT

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

ROAD SURFACE ISOCANDELA DIAGRAM

V.Short

1MH

Short

2.25MH

Medium

3.75MH

Long

Type I Type II Type III Type IV


6MH
1MH 1MH 1.75MH 2.75MH
Pavement Road
70% 13577
50% 9698.1
20% 3879.2
5% 969.81
2.5% 484.9

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 10 Of 11

LUMINOUS DISTRIBUTION INTENSITY DATA

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

Table--1 UNIT: ×10cd


C(DEG)
g (DEG) 0 15 30 45 60 75 90 105 120 135 150 165 180 195 210 225 240 255 270
0 1615 1608 1602 1597 1592 1587 1583 1578 1575 1570 1567 1564 1615 1608 1602 1597 1592 1587 1583
5 1612 1604 1597 1591 1587 1584 1582 1582 1584 1584 1585 1586 1640 1634 1631 1624 1616 1605 1594
10 1633 1628 1623 1616 1610 1606 1605 1607 1610 1613 1616 1619 1674 1673 1673 1666 1652 1632 1611
15 1661 1665 1666 1660 1646 1635 1636 1648 1662 1665 1660 1651 1701 1703 1708 1703 1687 1656 1625
20 1685 1697 1708 1702 1682 1666 1676 1710 1741 1743 1715 1680 1710 1715 1734 1741 1721 1676 1633
25 1685 1711 1745 1752 1724 1704 1727 1786 1839 1836 1773 1690 1693 1708 1756 1784 1759 1695 1644
30 1648 1705 1785 1810 1764 1720 1738 1819 1898 1895 1797 1667 1644 1688 1785 1845 1814 1725 1664
35 1578 1692 1834 1869 1783 1698 1691 1770 1874 1891 1787 1636 1613 1723 1892 1966 1881 1720 1635
40 1522 1712 1928 1922 1716 1501 1430 1499 1670 1756 1616 1374 1347 1468 1752 1833 1627 1358 1215
45 911 1199 1560 1560 1213 853 665 843 1069 1138 859 561 493 594 825 961 812 514 328
50 213 293 548 584 361 197 127 217 339 371 269 195 170 175 232 267 226 120 110
55 115 141 179 198 149 98.3 98.5 107 162 183 143 123 103 109 124 139 120 137 98.4
60 78.5 99.8 105 118 96.3 95.7 74.9 101 101 108 87.8 83.2 70.3 71.7 74.5 78.9 73.9 65.0 67.3
65 50.8 64.3 67.6 74.0 63.7 63.7 58.3 57.9 65.6 69.5 59.9 55.7 41.6 52.0 56.0 59.6 55.9 52.6 57.8
70 36.2 38.7 47.0 55.6 46.2 44.1 51.6 41.8 45.8 47.9 41.0 33.1 31.3 31.2 37.1 40.3 39.5 38.9 54.8
75 32.2 27.5 28.7 34.5 33.9 33.9 50.7 32.5 33.4 28.8 26.4 24.6 28.0 23.0 23.3 25.5 30.6 32.4 53.5
80 37.1 21.0 22.3 23.2 25.7 28.9 49.2 27.5 24.1 21.3 20.2 18.7 33.5 17.4 19.1 20.3 23.0 27.9 51.8
85 24.8 16.2 17.8 18.1 19.2 22.0 44.4 20.4 17.2 16.5 16.0 14.1 20.3 13.5 14.7 14.9 16.0 17.9 64.9
90 4.24 8.32 7.69 8.79 9.71 9.98 33.9 7.85 7.46 6.17 5.63 5.23 2.84 4.49 4.69 4.86 5.50 6.19 11.4

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 11 Of 11

LUMINOUS DISTRIBUTION INTENSITY DATA

Test:U:221.24V I:0.9205A P:198.16W PF:0.9781 Freq:0Hz Lamp Flux:34455.7x1 lm

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

Table--2 UNIT: ×10cd


C(DEG)
g (DEG) 285 300 315 330 345
0 1578 1575 1570 1567 1564
5 1582 1573 1566 1563 1560
10 1593 1582 1576 1575 1578
15 1605 1598 1598 1600 1605
20 1616 1628 1637 1637 1632
25 1647 1689 1718 1693 1651
30 1682 1762 1815 1761 1651
35 1663 1788 1870 1796 1619
40 1307 1559 1775 1754 1545
45 508 894 1239 1243 920
50 129 274 408 374 234
55 128 136 179 168 136
60 73.4 84.5 103 98.4 89.1
65 54.4 60.4 70.3 65.6 61.9
70 40.5 42.5 46.9 44.8 37.9
75 34.2 32.8 29.6 28.1 27.8
80 29.7 24.8 23.0 22.4 21.1
85 20.1 18.0 17.8 18.1 16.4
90 6.93 6.61 6.38 6.92 6.72

C Range: 0 - 360DEG g Range: 0 - 90DEG


C Interval: 15.0DEG g Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-3000H_V1 SYSTEM V2.00.411
Temperature:25.3DEG Humidity:65.0%
Operators:ADMIN Test Distance:9.000m [K=1.0000]
Test Date:2019-03-25 Remarks:

You might also like