You are on page 1of 4

YORK® YHAU-CG DIRECT FIRED

ABSORPTION CHILLERS/HEATERS
Increasing Efficiency and Reliability through Innovation
&RROLQJ &RROLQJ
:DWHU :DWHU
2XWOHW ,QOHW

Advancing Efficiency Double-effect direct fired cycle with innovative


YORK
:DWHU two-step evaporator and absorber design
&KLOOHG® (YDSRUDWRU
$EVRUEHU &RQGHQVHU

by Design
9
2XWOHW
/RZ7HPS
*HQHUDWRU

&KLOOHG
Compared to conventional designs, the YORK® YHAU-CG :DWHU
,QOHW
Double-Effect Direct Fired absorption chiller/heater uses
/*
9 9*
/*
69

an innovative two-step evaporator and absorber cycle 9+

that splits the absorption process into two steps, similar


+LJK7HPS
+HDW([FKDQJHU
5HIULJHUDQW3XPS

to how a series-counter-flow arrangement splits the work &KLOOHG


&RROLQJ
9

(YD
:DWHU
9

between two chillers. This, along with the parallel flow cycle, 2XWOHW
enables lower lithium-bromide solution concentrations, 5
:DWHU
2XWOHW
6ROXWLRQ /RZ7HPS

which reduces crystallization risk, reduces the potential for &LUFXODWLRQ3XPS

6ROXWLRQ6SUD\
+HDW([FKDQJHU
0
&RQWURO

&KLOOHG
3XPS

corrosion and improves efficiency, in conjunction with these &KLOOHG:DWHU


0RWRU

&RROLQJ:DWHU :DWHU
advanced components: ,QOHW
5HIULJHUDQW * 3

Low- and high-temperature solution plate heat 'LOXWHG6ROXWLRQ


&RQFHQWUDWHG6ROXWLRQ &KLQD2QO\
exchangers that optimize efficiency by enabling effective
heat transfer between the diluted and the concentrated
Condition ranges 5HIULJHUDQW3XPS

lithium-bromide solutions.
TYPICAL TYPICAL
Refrigerant drain plate heat exchanger that utilizes the heat CONDITIONS 1 CONDITIONS 2

of the warm refrigerant, saving energy. Chilled Water In 12°C 12°C


Chilled Water Out 7°C 7°C
Variable-frequency drive (VFD) solution pump that
Cooling Water In 30°C 32°C 1
provides superior part-load performance to reduce fuel
Cooling Water Out 35°C 37°C
consumption verses constant speed pumps. &KLOOHG:DWHU
&RROLQJ:DWHU
5HIULJHUDQW
'LOXWHG6ROXWLRQ
&KLOOHG (YDSRUDWRU
$EVRUEHU &RQGHQVHU
&RQFHQWUDWHG6ROXWLRQ
Flexible Operating
:DWHU
2XWOHW
Envelope /RZ7HPS
*HQHUDWRU

The YORK® YHAU-CG absorption chiller/heater design


combines the flexibility of a wide operating envelope with
&KLOOHG
the efficiency and reliability made possible by innovative
technology. The advanced YHAU-CG design is optimally suited
:DWHU
for natural gas or light oil energy sources commonly available
,QOHW
in commercial cooling and industrial process applications. /*
9 9*
/*
69
1. Two-step evaporator and absorber design has two pressure
YHAU-CG application flexibility
levels that uniquely divide the absorption process into two9+
DESIGN PARAMETERS TEMPERATURE RANGE steps. The chilled water flows through the tubes in series
through the two evaporators while the concentrated lithium-
Leaving chilled-water temperature As low as 4°C (39°F)
bromide solution is distributed in the absorber shell side
5HIULJHUDQW3XPS
in the opposite direction. This enhances absorption of the
Entering cooling-water temperature As high as 37°C (99°F) refrigerant into the concentrated solution, reducing solution 9
concentrations and overall pressure. This makes the unit
more efficient and reliable than conventional designs.
YORK® YHAU-CG DIRECT FIRED
ABSORPTION CHILLERS
422 - 5,626 kW (120 - 1,600 TR)
&RROLQJ &RROLQJ
:DWHU :DWHU
2XWOHW ,QOHW

Minimizing Total
Cost of Ownership
World-class YORK® engineering, support
3 and service reduce the cost of ownership by
/RZ7HPS
*HQHUDWRU'UDLQ simplifying startup and chiller operation over the
+HDW([FKDQJHU

life of the system. Here’s how:


$EVRUEHU &RQGHQVHU
DSRUDWRU
9
Better optimized for low condenser or
/RZ7HPS 4
*HQHUDWRU
9
cooling water flow thanks to the two-step
design and parallel flow cycle that minimizes
cooling water flow rates — series flow designs
/*
require higher flow rates.
9 9*
/*
69

Fully automatic purging system provides


9+ %851(5

([KDXVW
2 +LJK7HPS *DV2XWOHW
trouble-free operation by purging and
+HDW([FKDQJHU

removing non-condensable gases without


9

9 +LJK7HPS
operator intervention.
*HQHUDWRU

Superior hermetic integrity is ensured by


6ROXWLRQ /RZ7HPS
high quality processes and rigorous helium leak
&LUFXODWLRQ3XPS +HDW([FKDQJHU

6ROXWLRQ6SUD\
0
3LORW3LSLQJ
detection technique.
3XPS &RQWURO
0RWRU

*DV,QOHW
Control Center with graphical animated LCD
display lets the user see several operating
0DLQ3LSLQJ

* 3 parameters at once. Present and past


operational status, data recording and chiller
&KLQD2QO\
safeties are accessible at a touch.

/'D Isolation valves on the suction and discharge


2. Parallel flow cycle divides 4. High-temperature generator uses
of the solution and refrigerant pumps allow
the solution flow between the a water-tube design that contains
quick and easy servicing of pumps, which
low-temperature and high- the lithium-bromide solution inside
typically have a 60,000-hour life.
temperature generators into two the tubes and the flue gas (exhaust
parallel, balanced paths. The gas) on the shell side. This efficient,
result is safer and more efficient compact design provides a lower Factory functional testing on single-piece
operation at a much lower exhaust gas pressure drop than shipment assures control-panel and safety-
pressure than conventional series- conventional smoke-tube designs. device operation to reduce on-site startup time
flow designs. It also reduces the required amount in the field.
of lithium-bromide solution to speed
3. Gravity-fed low-temperature startup time and eliminates a ceramic
generator provides superior refractory to enhance reliability.
heat transfer compared to a
flooded generator and reduces 5. Gravity-fed distribution system for
the required amount of lithium the evaporator/absorber employs
bromide solution, decreasing stainless steel material that prevents
startup time from a cold start. corrosion and ensures performance
and long unit life.
Why install anything but YORK®?
You want high performance. You expect efficiency. And you need a chiller that gives you confidence.

When your reputation is at stake, it’s smart to demand nothing less than YORK® technology and service. That’s because we provide
local service and parts to keep your equipment operating at peak performance year after year. Enjoy the peace of mind knowing that
trained service experts and Original Equipment Manufacturer parts are available from Johnson Controls – the largest HVAC service and
preventative maintenance organization in the world.

Johnson Controls, the Johnson Controls logo, YORK and Metasys are registered trademarks of Johnson Controls, Inc. in the United States of America and other countries.
Other trademarks used herein may be trademarks or registered trademarks of other companies.
© 2017 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201. All rights reserved worldwide. Printed in USA PUBL-7959-B-0817. Supersedes: PUBL-7959-A-0216.

FOR MORE INFORMATION VISIT JOHNSONCONTROLS.COM

You might also like