You are on page 1of 9

TIA Selection Tool

Release Notes V2023.9

Unrestricted | © Siemens 2023


Features
Only available in offline version
• Integrated drive dimensioning (see here)
• Control Panel Design - Electrical dimensioning of main circuits according to IEC and
UL (see here)
• Integrated Safety Evaluation - Update SIEMENS VDMA Library V1.24.0

Offline and Cloud Version


• Logged in users
• …have the possibility to enter a project indicator to see the then valid prices.
• …in the regions Austria (AT) and Belgium (BE) now have the possibility to
contact the respective region for project-specific, technical questions via the
support request icon. The functionality will also be set up for other regions.
• Adjustments for SIRIUS 3RM1 motor starter
• Improvements in AML export, Safe Kinematics and plant configuration

Unrestricted | © Siemens 2023


Product updates
New products and updates for …

Controllers and I/O systems


• S7-1500: New CM 1542-1 communication module (6GK7542-1AX10-0XE0)
• S7-1500 / ET 200MP: New analog input module AI 8xHART HF
(6ES7531-7TF00-0AB0)
• New SIMATIC ET 200eco PN, AI 6x U/I + AIQ 2x U/I, M12-L, 8x M12 module
(6ES7146-6HF00-0BB0)

IPC / Panels
• Data updated for articles and accessories

SIPLUS
• Data updated

Unrestricted | © Siemens 2023


Product updates
New products and updates for …

SIMATIC IoT Gateways


• New articles for FDE - Field Data Enablement
(6ES7617-0BA01-0AB0 and 6ES7853-5BE00-0AA0)

Industrial communication
• Addition of accessories for SCALANCE SC6xx-2C

Power Supply
• New addition SITOP PSU4200

Unrestricted | © Siemens 2023


Features of the integrated drive dimensioning
New functionalities and products
• Frequency converters and motor modules can be dimensioned against currents
directly (without load)
• Extension of motion profiles with new pause type: Motoring in standstill
• Harmonization and more transparent representation of the relationships between:
pulse frequency, control mode, control cycle, and output frequency.
• New data: SIMOTICS 1LE5 SD Pro IE4 SH 280-315
• Configuration updates: SIMOTICS 1PH8, SIMOGEAR 2K3
• Data updates: SIMOTICS 1FL2, 1FE1, 1FN3, SIMOGEAR 2KJ3

• Lots of other bug fixes, improvements and internal changes

Not supported
• Help system: There is no special help system provided
• Project import

Unrestricted | © Siemens 2023


Features of the integrated drive dimensioning
Known issues
• Fixed – SIMOGEAR dimensioning requires .NET 6.0.14 installation
• The current calculation for permanent magnet synchronous motors in the field
weakening range (operation to the right of the voltage limit curve) delivers wrong
results in some special cases. Calculation model will be improved in the future
• 1FK2 with planetary gears - Filtering and sorting currently not according to the
system values
• 1FK2 motor at S120 AC/AC at 230V supply system, the 2CC cable connection
cannot be selected
• There are situations in which options that have already been configured cannot
be retained after changing a selected motor

Unrestricted | © Siemens 2023


Features of Control Panel Design
New functionalities

• Support of cable dimensioning for combinations with frequency converter and drive
systems for IEC circuits.
• New combination data for frequency converter and drive systems for IEC circuits.
• Optimized configuration workflow for soft starter combinations for IEC circuits.
• Soft starter configuration for US circuits according to UL508A.
• Minor improvements and bug fixes.

ATTENTION:
Some features are Beta features and not fully tested. They can contain errors. A hint is shown in the
software when you calculate the first device or load feeder combination.

Unrestricted | © Siemens 2023


Features of Control Panel Design
Known issues

• Cable dimensioning for soft starter combinations is not available at the


moment.
• In some cases the start of EPLAN generation is not successful if one or more
combinations in the main circuit are not fully configured (shows a warning
symbol). In this case try to start the EPLAN generation again.
• At the moment there are no soft starter combinations with 3TF contactors
available.

Unrestricted | © Siemens 2023


Disclaimer
© Siemens 2023

Subject to changes and errors. The information given in this document


only contains general descriptions and/or performance features which
may not always specifically reflect those described, or which may
undergo modification in the course of further development of the
products. The requested performance features are binding only when
they are expressly agreed upon in the concluded contract.

All product designations may be trademarks or other rights of


Siemens AG, its affiliated companies or other companies whose use by
third parties for their own purposes could violate the rights of the
respective owner.

Unrestricted | © Siemens 2023

You might also like