Karaguzel, PhD 2021 The Praxis of Performance Simulation
Thermal Insulation Thickness Calculator
R-Value (IP) 20 htft2F/Btu Define your required R-Value (IP units) R-Value (SI) 3.52 m^2K/W Thermal Conductance 0.284 W/m^2K Thermal Conductivitiy 0.007 W/mK Thermal Insulation Property (Update for a different insulation material) Required Thickness 0.025 m Use it to create a new material layer 2.5 cm 0.08 ft 1.0 inch
Sample Thermal Insulation Materials R-Value IP Thickness IP Thickness SI
Vacuum Insulation Panel (Variotec) R-20 1 2.5 Basic Thermo-physical Properties Value Units R-30 1.5 3.7 Conductivity 0.007 W/mK R-40 1.9 4.9 Density 256 kg/m3 Specific Heat Capacity 900 J/kgK
EPS Rigid Insulation (IESVE Library)
Basic Thermo-physical Properties Value Units Conductivity 0.025 W/mK Density 20 kg/m3 Specific Heat Capacity 1030 J/kgK