You are on page 1of 4

PJU 9 Meter

Images

1
PJU 9 Meter

Site 1 · Outdoor space 1 (Light scene 1)


Summary

Mounting height 9.000 m

Ground area 140.00 m² Height Working plane 0.000 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

2
PJU 9 Meter

Site 1 · Outdoor space 1 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 22.5 lx ≥ 10.0 lx WP1

Uo (g1 ) 0.42 ≥ 0.10 WP1

Energy estimation(2) Consumption 788 kWh/a max. 4950 kWh/a

Room Lighting power density 0.64 W/m² –

2.86 W/m²/100 lx –

(1) Based on a rectangular space of 20.000 m x 7.000 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: General circulation areas at outdoor workplaces (5.1.2 Traffic areas for slow-moving vehicles (max.10 km/h), e.g. bicycles, excavators)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Not yet a LEDENVO LED ST 90W 757 – 90.0 W 12239 lm 136.0 lm/W
DIALux
member

3
PJU 9 Meter

Site 1 · Outdoor space 1 (Light scene 1)


Working plane (Outdoor space 1)

Properties Ē Emin Emax Uo (g1 ) g2 Index


(Target) (Target)

Working plane (Outdoor space 1) 22.5 lx 9.52 lx 34.5 lx 0.42 0.28 WP1
Perpendicular illuminance (adaptive) (≥ 10.0 lx) (≥ 0.10)
Height: 0.000 m, Wall zone: 0.000 m

Utilisation profile: General circulation areas at outdoor workplaces (5.1.2 Traffic areas for slow-moving vehicles (max.10 km/h), e.g. bicycles, excavators)