1.

The power factor at which the transformer operates is

a. Is unity
b. is 0.8 lag
c. Is 0.8 lead
d. Depends upon the power factor of the load

2. Which of the following will improve the mutual coupling between primary
and secondary circuit?

a. Transformer oil of high break down voltage


b. High reluctance magnetic core
c. Winding material of high resistivity
d. Low reluctance magnetic core

3. High leakage transformers are of

a. Small voltage-ampere rating


b. High voltage-ampere rating
c. High voltage rating
d. Low voltage rating

4. Distribution transformers are designed to have maximum efficiency nearly


at

a. 100% of full load


b. 50-70% of full load
c. 25% of full load
d. 10% of full load

5. For welding purpose, the secondary transformer used should be capable of


carrying

a. High Voltage, High Current


b. High voltage, Low Current
c. Low Voltage, High current
d. Low Voltage, Low Current

6. The high-voltage and low-voltage winding resistances of a


distribution transformer of 100 kVA, 1100/220 volts, 50 Hz are 0.1 Ω and
0.004 Ω respectively. The equivalent resistances referred to high-voltage side
and low-voltage side are respectively ?

a. 2.504 Ω and 0.2 Ω


b. 0.2 Ω and 0.08 Ω
c. 0.10016 Ω and 2.504 Ω
d. 0.008 Ω and 0.10016 Ω
7. A 10 Ω resistive load is to be impedance matched by a transformer to a
source with 6250Ω of internal resistance. The ratio of primary to secondary
turns of the transformer should be

a. 25
b. 10
c. 15
d. 20

8. Low voltage windings are placed nearer to the core in the case of concentric
windings because

a. It reduces hysteresis loss


b. It reduces eddy current loss
c. It reduces insulation requirement
d. It reduces leakage fluxes

9. The transformer used in a welding set is

a. Step-up transformer
b. Step-down transformer
c. Constant Current transformer
d. Booster transformer

10. The no-load input power to a transformer is practically equal to ______ loss
in the transformer

a. Windage
b. Eddy current
c. Copper
d. Iron

11. A no-load test is performed on a transformer to determine

a. Magnetizing current only


b. Core losses only
c. Efficiency
d. Magnetizing current and losses

12. In order to minimize loss due to hysteresis, the magnetic material should
have

a. High resistivity
b. Low Hysteresis co-efficient
c. Smaller B-H loop area
d. High retentivity
13. The low voltage winding of a 400/230 V, 1-phase 50 Hz transformer is to be
connected to a 25 Hz supply. In order to keep the magnetization current at
the same level as that for normal 50 Hz, the supply voltage should be

a. 230 V
b. 460 V
c. 115 V
d. 65 V

14. Determine the maximum flux density (in T) of a material having eddy
current coefficient of 2, the thickness of 4 mm, the volume of 20 cu.meter,
which is supplied by the frequency of 50 Hz when the material has eddy
current loss of 6 W.

a. 2.24
b. 3.34
c. 1.94
d. 1.21

15. A short-circuit test on a transformer gives

a. The copper loss at full load


b. The copper loss at any load
c. The copper loss at half load
d. The copper loss at overload

16. Which is to be short-circuited on performing short circuit test on a


transformer?

a. Low voltage side


b. High voltage side
c. Primary side
d. Secondary side

17. What kVA rating is required for a transformer that must handle a
maximum load current of 8 A with a secondary voltage of 2 kV?

a. 4 kVA
b. 0.25 kVA
c. 16 kVA
d. 8 kVA

18. If 25 W of power are applied to the primary of an ideal transformer with a


turns ratio of 10, the power delivered to the secondary load is

a. 25 W
b. 0W
c. 250 W
d. 2.5 W
19. In a certain loaded transformer, the secondary voltage is one-fourth the
primary voltage. The secondary current is

a. one-fourth the primary current


b. four times the primary current
c. equal to the primary current
d. one-fourth the primary current and equal to the primary current

20. The primary of a transformer is connected to a 6 V battery. The turns ratio


is 1:3 and the secondary load, RL, is 100 . The voltage across the load is

a. 0V
b. 6V
c. 18 V
d. 2V

21. A, B and C are the three windings of a transformer having 200, 100 and 60
turns respectively. When a voltage of 100 V is applied across A, the voltage
that develops across xy is _______ Volts.

100

22. A large transformer operating at no-load draws an exciting current I0 = 5 A


when the primary is connected to a 120 V, 60 Hz source as shown in the
figure. If the iron losses are equal to 180 W, the magnetizing reactance will
be.

a. 80 Ω
b. 24 Ω
c. 25.2 Ω
d. 32 Ω

23. A 250 kVA, 11000 V/400 V and 50 Hz single-phase transformer has 80 turns
on the secondary, what is the maximum value of flux?

a. 2475 mWb
b. 0.2 mWb
c. 22.5 mWb
d. 55.2 mWb

24. The rating of primary winding of a transformer, having 60 turns is 250 V, 50


Hz. If the core cross section area is 144 cm2 then the flux density in the core
is _____ T.

25. Consider the transformer shown in the figure. Find reffered impedance
towards primary side?