TEST REPORT
IEC 62368-1
Audio/video, information and communication technology equipment
Part 1: Safety requirements
Report Number .............................. : BCTC2110790788S
Date of issue ................................... : 2022-06-21
Total number of pages .................... : 74
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Miko Li
Tested by (name, function, signature) ........ :
(Project Handler)
Seven Zheng
Approved by (name, function, signature) ... :
(Reviewer)
2800W×4@4Ω
Importer: XXXXXX
Address: XXXXXX
Made in China
Note:
1. Note: The height dimension of CE mark should not less than 5mm, the height dimension of WEEE symbol
should not less than 7mm.
2. The above markings are the minimum requirements required by the safety lab. For the final
production samples, the additional markings which do not give rise to misunderstanding may be
added.
3. The marking plates of other models in this report are identical with above except model name.
4. According to the EU directives which have been aligned with EU NLF (new legislative framework), both of
manufacturer and importer’s name and address shall be affixed on the product or, where that is not possible,
on its packaging or in a document accompanying the product before the product is placed on the EU market.
GENERAL REMARKS:
“(See Enclosure #)” refers to additional information appended to the report.
“(See appended table)” refers to a table appended to the report.
ES PS MS TS RS
OVERVIEW OF EMPLOYEDSAFEGUARDS
Clause Possible Hazard
5.1 Electrically-caused injury
Body Part Energy Source Safeguards
(e.g. Ordinary) (ES3: Primary Filter
Basic Supplementar Reinforced(En
circuit)
y closure)
Ordinary ES3: Primary circuit N/A N/A Enclosure
See 5.4.2,
5.4.3, 5.4.4,
5.5.3 and
5.5.4
Ordinary ES3: Line and Neutral N/A N/A See 5.5.2.2
(Stored energy in X-
Capacitor)
Ordinary ES1: Output port N/A N/A N/A
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4 GENERAL REQUIREMENTS P
4.1.1 Acceptance of materials, components and P
subassemblies
4.1.2 Use of components P
4.1.3 Equipment design and construction P
4.1.15 Markings and instructions .................................. : (See Annex F) P
4.4.4 Safeguard robustness P
4.4.4.2 Steady force tests .............................................. : (See Annex T.2, T.5) P
4.4.4.3 Drop tests .......................................................... : (See Annex T.7) N/A
4.4.4.4 Impact tests ....................................................... : (See Annex T.6) P
4.4.4.5 Internal accessible safeguard enclosure and N/A
barrier tests........................................................ :
4.4.4.6 Glass Impact tests ............................................. : N/A
4.4.4.7 Thermoplastic material tests ............................. : N/A
4.4.4.8 Air comprising a safeguard ................................ : (See Annex T) N/A
4.4.4.9 Accessibility and safeguard effectiveness P
4.5 Explosion P
4.6 Fixing of conductors P
4.6.1 Fix conductors not to defeat a safeguard P
4.6.2 10 N force test applied to ................................. : See appended table 5.4.2.2, P
5.4.2.4 and 5.4.3
4.7 Equipment for direct insertion into mains socket N/A
– outlets
4.7.2 Mains plug part complies with the relevant N/A
standard............................................................. :
4.7.3 Torque (Nm) ...................................................... : N/A
4.8 Products containing coin/button cell batteries No such battery N/A
4.8.2 Instructional safeguard N/A
4.8.3 Battery Compartment Construction N/A
Means to reduce the possibility of children
removing the battery.......................................... :
4.8.4 Battery Compartment Mechanical Tests ........... : N/A
4.8.5 Battery Accessibility N/A
4.9 Likelihood of fire or shock due to entry of See Annex p P
conductive object ............................................... :
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5 ELECTRICALLY-CAUSED INJURY P
5.2.1 Electrical energy source classifications............... : (See appended table 5.2) P
5.2.2 ES1, ES2 and ES3 limits P
5.2.2.2 Steady-state voltage and current ........................ : (See appended table 5.2) P
5.2.2.3 Capacitance limits ................................................ : (See appended table 5.2) P
5.2.2.4 Single pulse limits ................................................ : N/A
5.2.2.5 Limits for repetitive pulses ................................... : N/A
5.2.2.6 Ringing signals .................................................... : N/A
5.2.2.7 Audio signals ....................................................... : See clause E.1 P
5.3 Protection against electrical energy sources P
5.3.1 General Requirements for accessible parts to See only 4.3 and 5.3 to 5.6 which P
ordinary, instructed and skilled persons applies to protection between the
accessible parts and hazardous
parts of other circuits.
5.3.2.1 Accessibility to electrical energy sources and Only ES1 circuit can be accessed P
safeguards for this product.
5.3.2.2 Contact requirements No opening of enclosure, no access P
with test probe to any ES3 circuit or
parts.
a) Test with test probe from Annex V .................. : (See Annex V) N/A
b) Electric strength test potential (V) ................... : N/A
c) Air gap (mm) ................................................... : N/A
5.3.2.4 Terminals for connecting stripped wire N/A
5.4 Insulation materials and requirements P
5.4.1.2 Properties of insulating material P
5.4.1.3 Humidity conditioning ........................................ : Hygroscopic material used as
Sound-deadening material.
Not used as an Insulation Material.
The whole product complies with P
humidity treatment test clause
5.4.8 and electric strength test
clause 5.4.9
5.4.1.4 Maximum operating temperature for insulating (See appended table 5.4.1.4)
P
materials .............................................................. :
5.4.1.5 Pollution degree ................................................... : PD2
5.4.1.5.2 Test for pollution degree 1 environment and for an N/A
insulating compound
5.4.1.5.3 Thermal cycling N/A
5.4.1.6 Insulation in transformers with varying dimensions N/A
5.4.1.7 Insulation in circuits generating starting pulses N/A
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
6.3.1 (a) No ignition and attainable temperature value less (See appended table 5.4.1.4, P
than 90 % defined by ISO 871 or less than 300 C 6.3.2, 9.0, B.2.6)
for unknown materials ....................................... :
6.3.1 (b) Combustible materials outside fire enclosure P
6.4 Safeguards against fire under single fault conditions P
6.4.1 Safeguard Method Control of fire spread P
6.4.2 Reduction of the likelihood of ignition under single N/A
fault conditions in PS1 circuits
6.4.3 Reduction of the likelihood of ignition under single N/A
fault conditions in PS2 and PS3 circuits
6.4.3.1 General N/A
6.4.3.2 Supplementary Safeguards N/A
Special conditions if conductors on printed boards N/A
are opened or peeled
6.4.3.3 Single Fault Conditions ........................................ : N/A
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits P
6.4.5 Control of fire spread in PS2 circuits P
6.4.5.2 Supplementary safeguards .............................. : Compliance detailed as follows: P
− Printed board: rated min. V-0
− All other components: at least V-
2 except for parts mounted on
min. V-1 material or small parts
of combustible material (with
mass less than 4g) or
components complying to
relevant IEC standard.
− Isolating transformer: complying
with G.5.3.
− Parts as in 6.4.5 above including
wiring
Fire enclosure rated V-0 used.
6.4.6 Control of fire spread in PS3 circuit Compliance detailed as follows: P
- see 6.4.5.2
- Fire enclosure rated V-0 used.
6.4.7 Separation of combustible materials from a PIS N/A
6.4.7.1 General .............................................................. : N/A
6.4.7.2 Separation by distance N/A
6.4.7.3 Separation by a fire barrier N/A
6.4.8 Fire enclosures and fire barriers P
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
8 MECHANICALLY-CAUSED INJURY P
8.1 General P
8.2 Mechanical energy source classifications MS1 P
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
10 RADIATION P
10.2 Radiation energy source classification P
10.2.1 General classification RS1:indicator lights P
10.3 Protection against laser radiation N/A
Laser radiation that exists equipment:
Normal, abnormal, single-fault ............................ : N/A
Instructional safeguard ........................................ :
Tool...................................................................... :
10.4 Protection against visible, infrared, and UV P
radiation
10.4.1 General indicator lights,exempt group P
10.4.1.a) RS3 for Ordinary and instructed persons ............ : N/A
10.4.1.b) RS3 accessible to a skilled person ..................... : N/A
Personal safeguard (PPE) instructional
safeguard............................................................. :
10.4.1.c) Equipment visible, IR, UV does not exceed RS1 . : N/A
10.4.1.d) Normal, abnormal, single-fault conditions ......... : N/A
10.4.1.e) Enclosure material employed as safeguard is N/A
opaque................................................................. :
10.4.1.f) UV attenuation ..................................................... : N/A
10.4.1.g) Materials resistant to degradation UV ................. : N/A
10.4.1.h) Enclosure containment of optical radiation ......... : N/A
10.4.1.i) Exempt Group under normal operating P
conditions ............................................................ :
10.4.2 Instructional safeguard ........................................ : N/A
10.5 Protection against x-radiation N/A
10.5.1 X- radiation energy source that exists equipment : N/A
Normal, abnormal, single fault conditions N/A
Equipment safeguards ........................................ : N/A
Instructional safeguard for skilled person............. : N/A
10.5.3 Most unfavourable supply voltage to give
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
F.3.5.3 Replacement fuse identification and rating Fuse is not replaceable by ordinary P
markings ..............................................................: person, however fuse marking on
PCB adjacent to fuse:
F1 T2A 250V
F.3.5.4 Replacement battery identification marking ........: No such battery N/A
F.3.5.5 Terminal marking location P
F.3.6 Equipment markings related to equipment P
classification
F.3.6.1 Class I Equipment P
F.3.6.1.1 Protective earthing conductor terminal P
F.3.6.1.2 Neutral conductor terminal P
F.3.6.1.3 Protective bonding conductor terminals N/A
F.3.6.2 Class II equipment (IEC60417-5172) P
F.3.6.2.1 Class II equipment with or without functional earth P
F.3.6.2.2 Class II equipment with functional earth terminal N/A
marking
F.3.7 Equipment IP rating marking .............................. : IPX0.
F.3.8 External power supply output marking N/A
F.3.9 Durability, legibility and permanence of marking Marking label is tested in appliance P
F.3.10 Test for permanence of markings After the test, the marking remains P
legible.
F.4 Instructions P
a) Equipment for use in locations where children The accessibility of equipment N/A
not likely to be present – marking isevaluated using the test probe of
Figure V.1
b) Instructions given for installation or initial use The equipment is intended to be P
used for information technology
equipment or audio/video
equipment.
c) Equipment intended to be fastened in place P
d) Equipment intended for use only in restricted N/A
access area
e) Audio equipment terminals classified as ES3 N/A
and other equipment with terminals marked in
accordance F.3.6.1
f) Protective earthing employed as safeguard N/A
g) Protective earthing conductor current exceeding N/A
ES 2 limits
h) Symbols used on equipment N/A
i) Permanently connected equipment not provided N/A
with all-pole mains switch
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
- Excessive discharging rate for any battery (See append table Annex M.3) N/A
M.3.3 Compliance ......................................................... : (See append table Annex M.3) N/A
M.4 Additional safeguards for equipment containing N/A
secondary lithium battery
M.4.1 General N/A
M.4.2 Charging safeguards N/A
M.4.2.1 Charging operating limits N/A
M.4.2.2a) Charging voltage, current and temperature ........ : (See append table Annex M.4)
M.4.2.2 b) Single faults in charging circuitry ........................ : (See append table Annex M.4)
M.4.3 Fire Enclosure PS1 N/A
M.4.4 Endurance of equipment containing a secondary N/A
lithium battery
M.4.4.2 Preparation N/A
M.4.4.3 Drop and charge/discharge function tests N/A
Drop N/A
Charge N/A
Discharge N/A
M.4.4.4 Charge-discharge cycle test N/A
M.4.4.5 Result of charge-discharge cycle test N/A
M.5 Risk of burn due to short circuit during carrying N/A
M.5.1 Requirement N/A
M.5.2 Compliance and Test Method (Test of P.2.3) N/A
M.6 Prevention of short circuits and protection from N/A
other effects of electric current
M.6.1 Short circuits N/A
M.6.1.1 General requirements N/A
M.6.1.2 Test method to simulate an internal fault Component cell complied with N/A
IEC62133 2nd. And UL1642
approved component and
complied with Impact test. whose
test condition and criteria can
cover those in IEC62281 Impact
test.
M.6.1.3 Compliance (Specify M.6.1.2 or alternative N/A
method) .............................................................. :
M.6.2 Leakage current (mA) ........................................ : N/A
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
X-capacitor Tenta Electric MEX 0,22 μF, 275VAC, IEC 60384-14 VDE 119119
(C13) Industrial Co. Ltd. 40/100/21B, X2 EN 60384-14
SHENZHEN
WEIDY
0.22UF K310VAC EN/IEC:60384-
(Alternative) INDUSTRIAL MKP UL E334332
X2 40/110 14
DEVELOPMENT
CO., LTD.
Jyh Chung JD Max:2200 pF, IEC 60384-14 VDE
Y-cap (C11) Electronic Co., Ltd. Min:250VAC, EN 60384-14 137027
40/125/21C, Y1
JYA-NAY CO., JN Max:2200 pF EN 60384-14 TUV
(Alternative) LTD. Min:250VAC R50232059
25/125/21C, Y1 UL E201384
Optocoupler (U2) Zhuhai Dapeng Int. Cr / Ext. Cr / IEC 60747-5-5 VDE
Electronics Dti. ≥7,6 mm / ≥7,6 EN 60747-5-5 40038417
DPC-817C
Technology Co. mm / ≥0,4 mm, 110
oC
Ltd.
COSMO Electronics Int. CR / Ext. CR / IEC 60747-5-5 VDE 101347
(Alternative) Corporation Dti. ≥5,2 mm / ≥5,2 EN 60747-5-5
KPC817
mm / ≥0,4 mm, 110
oC
Material of ZHEJIANGJINDA
pluggable ELECTRONICS VH-3A 250VAC,7A IEC/EN 62368-1 UL E237523
connector CO LTD
SHENZHEN PIN N1 (1-4): 0,35 mm
ZHENG WANG T9*5*3 x 1P 14,5Ts, Tested with
Line filter (FL1) EN 60065
ELECTRONIC CO., 800uH N2 (2-3): 0,30 mm appliance
LTD x 1P 14,5Ts
DONG GUAN
- Wire YIDA
xUEW/130 130°C UL 1446 UL E344055
INDUSTRIAL CO
LTD
SHENZHEN
KAIZHONG
- Triple insulated 130°C, reinforced
HEDONG NEW TIW-B UL 2353 UL E357240
wire insulation
MATERIALS CO
LTD
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
N1 (1-4): 0,1 mm x
SHENZHEN HAO 1,0 52Ts,
FENG DA SQ1212 Tested with
Line filter (FL2) N2 (2-3): 0,1 mm x EN 60065
ELECTRONIC CO., 15mH appliance
1,0
LTD
52Ts,
WUXI JUFENG
-Wire COMPOUND xUEW155 155°C UL 1446 UL E206882
LINE CO LTD
CHANG CHUN Phenolic, V-0, Min.
- Bobbin PLASTICS CO T375HF 150°C, min. UL 746, UL 94 UL E59481
LTD 0.75mm
Bleed resistor
resistance:1.5MΩ Tested in
R20,R21,R28,R Interchangeable Interchangeable IEC/EN 62368-1
equipment
POWER:0.125W
26
Electrolytic Max.33μF~68uF,
Tested in
Capacitor Interchangeable Interchangeable Min.105°C, IEC/EN 62368-1
equipment
(C1) Min. 400V
Transformer (T1) SHAN TOU XIN KE PZW-H80C Class B IEC62368-1 Tested with
ELECTRONIC CO., appliance
EC2820-P2620
LTD
- Magnet wire SHENZHEN (x)UEW-E-(&)- 130°C UL UL E227475
CHENGWEI (*)
INDUSTRY CO
LTD
IEC62368-1 UL E332529
-Triple insulated Suzhou Yusheng
TIW-B Min. 130°C Annex J, VDE
wire Electronic Co., Ltd.
UL 60950-1 40033527
CHANG CHUN
Phenolic:V-0,
-BOBBIN PLASTICS T373J/T375J UL94, UL746 UL E59481
Min 150°C
CO.,LTD
JINGJIANG
YAHUA
-Insulating Tape PRESSURE PZ* (b) 130C/ YELLOW UL510A UL E165111
SENSITIVE GLUE
CO LTD
SHENZHEN
WOER HEAT
-Tube SHRINKABLE WF 200°C, VW-1 UL 224 UL E203950
MATERIAL CO
LTD
HANG CHEUNG
-Varnish COATINGS 8562* 155C UL 1446 UL E200154
(HUIYANG) LTD
Glue Interchangeable Interchangeable Min. V-2 UL 94 UL
Supplementary information:
1) Provided evidence ensures the agreed level of compliance. See OD-CB2039.
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
-- -- 1 --
-- -- 2 --
-- -- 3 --
4.8.4.5 TABLE: Impact
Impacts per surface Surface tested Impact energy (Nm) Comments
-- -- -- --
-- -- -- --
4.8.4.6 TABLE: Crush test
Test position Surface tested Crushing Force (N) Duration force
applied (s)
-- -- -- --
-- -- -- --
Supplementary information:
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
4.8.5 TABLE: Lithium coin/button cell batteries mechanical test result N/A
Test position Surface tested Force (N) Duration force
applied (s)
-- -- -- --
Supplementary information:
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
pin1 ,OC
Single fault –U2 0.182mApk 50
--
pin3,OC
Single fault –U1 0.182mApk 50
--
pin2-5,SC
Single fault –U1 0.182mApk 50
--
pin1-5,SC
Single fault – 0.182mApk 50
--
C9,SC
4 253V/50Hz USB “+”, “-” to Normal -- 0.06mApk 50 ES1
earth 0.06mApk 50
Abnormal –
--
Output overload
Single fault –U2 0.06mApk 50
--
pin1-2 ,SC
Single fault –U2 0.06mApk 50
--
pin2-3 ,SC
Single fault –U2 0.06mApk 50
--
pin1 ,OC
Single fault –U2 0.06mApk 50
--
pin3,OC
Single fault –U1 0.06mApk 50
--
pin2-5,SC
Single fault –U1 0.06mApk 50
--
pin1-5,SC
Single fault – 0.06mApk 50
--
C9,SC
5.2.2.3 - Capacitance Limits
Location (e.g. Parameters
Supply
No. circuit Test conditions ES Class
Voltage Capacitance, nF Upk (V)
designation)
1 264 Vac L-N (CX) Normal 0.22uF±10% 310 ES3
5.2.2.4 - Single Pulses
Location (e.g. Parameters
Supply
No. circuit Test conditions ES Class
Voltage Duration (ms) Upk (V) Ipk (mA)
designation)
-- -- -- Normal -- -- --
Abnormal -- -- --
--
Single fault – -- -- --
SC/OC
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:
t1 (°C) R1 () t2 (°C) R2 () T (C) Allowed Insulation
Temperature T of winding:
Tmax (C) class
-- -- -- -- -- -- -- --
-- -- -- -- -- -- -- --
Supplementary information:
Note 1: Tma should be considered as directed by appliable requirement
Note 2: Tma is not included in assessment of Touch Temperatures (Clause 9)
supplementary information:
Different polarity of fuse 420 240 60Hz 1.27 3.2 2.4 3.2
(FUSE1)(BI)
Primary trace to secondary trace 420 240 60Hz 2.54 7.4 4.8 7.4
across C11 on PCB (RI)
Primary trace to secondary trace 420 240 60Hz 2.54 6.4 4.8 6.4
of U2 (RI)
Primary trace to secondary trace 468 248 104.1kHz 2.54 14.9 5.0 14.9
of T1 (RI)
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Primary winding to secondary 468 248 104.1kHz 2.54 13.2 5.0 13.2
pins of T1 (RI)
Secondary pins to core of T1 468 248 104.1kHz 2.54 12.6 5.0 12.6
(RI)
Supplementary information:
F= Functional insulation, B= Basic insulation, S= Supplementary insulation, R= Reinforced insulation.
Supplementary information:
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Functional:
Line and neutral after current fuse opened DC 2500 No
L/N to metal enclosure with metal foil DC 2500 No
Basic/supplementary:
-- -- -- --
Reinforced:
Primary winding to secondary winding of T1 DC 4000 No
Core to secondary winding of T1 DC 4000 No
One layer insulation tape of T1 DC 4000 No
Routine Tests:
-- -- -- --
Supplementary information:
1. Core of transformers T1 is considered as primary part.
2. Above test performed immediately after the humidity test.
3. All materials listed in table 4.1.2 are tested.
4. For the unit, test performed immediately following temperature test in 5.4.1.4
5. The DC voltage source was performed on all testing once in forward and once in reverse.
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
2* --
3 --
4 --
5 --
6 --
8 --
Supplementary Information:
Notes:
[1] Supply voltage is the anticipated maximum Touch Voltage
[2] Earthed neutral conductor [Voltage differences less than 1% or more]
[3] Specify method used for measurement as described in IEC 60990 sub-clause 4.3
[4] IEC60990, sub-clause 6.2.2.7, Fault 7 not applicable.
[5] (*) IEC60990, sub-clause 6.2.2.2 is not applicable if switch or disconnect device (e.g., appliance coupler)
provided.
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary Information:
(*) Measurement taken only when limits at 3 seconds exceed PS1 limits.
(**) For worst case power source fault results are shut down.
SC=Short circuit, OC=Open circuit
An Arcing PIS requires a minimum of 50 V (peak) a.c. or d.c. An Arcing PIS is established when the product of
the open circuit voltage (Vp) and normal operating condition rms current (Irms) is greater than 15.
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:
Test table is provided to record abnormal and fault conditions for all applicable energy sources including
Thermal burn injury. Column “Abnormal/Fault.” Specify if test condition by indicating “Abnormal” then the
condition for a Clause B.3 test or “Single Fault” then the condition for Clause B.4.
[x] During single fault operating condition test, the output voltage did not increase by more than 3V or 10%
which one is higher of its rated output voltage under normal operating condition (For USB outlet or connector),
[] During single fault operating condition test, the output voltage did not increase by more than 10% of its rated
output voltage under normal operating condition (For other outlet or connector at ES1)
F1 opened
253V/50Hz 0.109 immediately, no
FUS
D1 pin AC to“+” SC 1s -- -- hazard.
E1 →0
Touch current:
0.182mApk
F1 opened
0.109 immediately, no
FUS
C11 SC 253V/50Hz 1s -- -- hazard.
E1 →0
Touch current:
0.182mApk
F1 opened
FUS 0.109 immediately, no
U1 pin2-5 SC 1s -- --
253V/50Hz E1 →0 hazard.
Touch current:
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
0.182mApk
F1 opened
0.109 immediately, no
FUS
U1 pin1-5 SC 253V/50Hz 1s -- -- hazard.
E1 →0
Touch current:
0.182mApk
F1 opened
0.109 immediately, no
FUS
Q1 pin G-D SC 253V/50Hz 1s -- -- hazard.
E1 →0
Touch current:
0.182mApk
F1 opened
0.109 immediately, no
FUS
Q1 pin S-D SC 253V/50Hz 1s -- -- hazard.
E1 →0
Touch current:
0.182mApk
Unit shutdown
immediately, no
253V/50Hz FUS 0.109 damage, no
Q1 pin G-S SC 1s -- -- hazard.
E1 →0.002
Touch current:
0.182mApk
Unit shutdown
immediately, no
253V/50Hz FUS 0.109 damage, no
U2 pin1-2 SC 10mins -- -- hazard.
E1 →0.002
Touch current:
0.182mApk
Unit shutdown
immediately, no
253V/50Hz FUS 0.109 damage, no
U2 pin2-3 SC 10mins -- -- hazard.
E1 →0.002
Touch current:
0.182mApk
Unit shutdown
253V/50Hz immediately, no
FUS 0.109 damage, no
U2 pin1 SC 10mins -- -- hazard.
E1 →0.002
Touch current:
0.182mApk
Unit shutdown
immediately, no
253V/50Hz FUS 0.109 damage, no
U2 pin3 SC 10mins -- -- hazard.
E1 →0.002
Touch current:
0.182mApk
FUS Unit shutdown
C18 SC 10mins 0.109 -- -- immediately, no
E1
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
[] During single fault operating condition test, the output voltage did not increase by more than 10% of its rated
output voltage under normal operating condition (For other outlet or connector at ES1)
Annex M.4 Table: Additional safeguards for equipment containing secondary lithium N/A
batteries
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Annex Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS) N/A
Note: Measured UOC (V) with all load circuits disconnected:
Output Components Uoc (V) Isc (A) S (VA)
Circuit
Meas. Limit Meas. Limit
8 100
8 100
Supplementary Information:
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Supplementary information:N/A.
10.5.1 Add the following after the first paragraph: Added. N/A
For RS 1 compliance is checked by
measurement under the following conditions:
In addition to the normal operating conditions,
all controls Bluetooth headphonefrom the
outside by hand, by any object such as a tool
or a coin, and those internal adjustments or
presets which are not locked in a reliable
manner, are adjusted so as to give maximum
radiation whilst maintaining an intelligible
picture for 1 h, at the end of which the
measurement is made.
NOTE Z1 Soldered joints and paint lockings are
examples of adequate locking.
The dose-rate is determined by means of a
radiation monitor with an effective area of 10
cm², at any point 10 cm from the outer surface
of the apparatus.
Moreover, the measurement shall be made
under fault conditions causing an increase of
the high-voltage, provided an intelligible
picture is maintained for 1 h, at the end of
which the measurement is made.
For RS1, the dose-rate shall not exceed 1
μSv/h taking account of the background level.
NOTE Z2 These values appear in Directive
96/29/Euratom of 13 May 1996.
10.6.1 Add the following paragraph to the end of the Added. N/A
subclause:
EN 71-1:2011, 4.20 and the related tests
methods and measurement distances apply.
10.Z1 Add the following new subclause after 10.6.5. N/A
10.Z1 Non-ionizing radiation from radio
frequencies in the range 0 to 300 GHz
The amount of non-ionizing radiation is
regulated by European Council
Recommendation 1999/519/EC of 12 July
1999 on the limitation of exposure of the
general public to electromagnetic fields (0 Hz
to 300 GHz).
For intentional radiators, ICNIRP guidelines
should be taken into account for Limiting
Exposure to Time-Varying Electric, Magnetic,
and Electromagnetic Fields (up to 300 GHz).
For hand-held and body-mounted devices,
attention is drawn to EN 50360 and EN 50566
G.7.1 Add the following note: Added. N/A
NOTE Z1 The harmonized code designations
corresponding to the IEC cord types are given in Annex
ZD.
Product photos
EUT PHOTO 1
EUT PHOTO 2
EUT PHOTO 3
EUT PHOTO 4
EUT PHOTO 5
EUT PHOTO 6
EUT PHOTO 7
EUT PHOTO 8
EUT PHOTO 9
EUT PHOTO 10
EUT PHOTO 11
EUT PHOTO 12
STATEMENT
2.The test report can not be partially copied unless prior written approval is issued from our lab.
4.The test report is invalid without signature of person(s) testing and authorizing.
5.The test process and test result is only related to the Unit Under Test.
7.If there is any objection to report, the client should inform issuing laboratory within 15 days from
the date of receiving test report.
Address:
1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Tangwei, Fuhai Subdistrict,
Bao'an District, Shenzhen, Guangdong, China
TEL:400-788-9558
P. C.: 518103
FAX:0755-33229357
Website:http://www.chnbctc.com
E-Mail:bctc@bctc-lab.com.cn