You are on page 1of 1

Data sheet for three-phase motors

MLFB-Ordering data: 1LA8315-4AB60-Z


B31+B32+F28+F83+K45+L00+Y54

Client order no.: Item no.:


Order no.: Consignment no.:
Offer no.: Project:
Remarks:

Electrical data: General data:


Frame size
Type data: 315

Power P Method of cooling


250 kW IC411 - self ventilated open-circuit cooled
Thermal class / utilisation Mode of operation
155(F) to 130(B) Line
Rated voltage U D/Y Type of construction
400/690 VD/Y 50 Hz IM B3
Frequency f
50 Hz Degree of protection
IP55
Speed n
1488 1/min Total weight
1300 kg
Motor torque M
1605 Nm Coating (paint finish)
Special paint finish
Current I VD VY
434 A 252 A Color, paint shade
See options

Rated data: Type of explosion protection


none
Rated power PN:
250 kW Standards/specifications
IEC, DIN, ISO, VDE, EN
Thermal class / utilisation
155(F) to 130(B) Motor protection
Service factor PTC thermistor motor protection using 6 integrated
1.00 temperature sensors for alarm and shutdown
Rated speed nN
1488 1/min
Terminal box:
Rated torque MN
1605 Nm Type of terminal box
1XB1 631
Rated current IN VD VY
Conductor cross section, max. (IEC)
434 A 252 A 240 mm²
Starting / rated current IA/IN
6.50 Contact screw thread
M16
Breakdown/rated torque MK/MN Cable diameter from ... to …
2.80 56,0 ... 68,5

Starting / rated torque MA/MN Cable entry


4 x M80x2 + 2 x M25x1,5
1.80

Efficiency class in acc. to 60034-30-1/NEMA Special design:


IE2

Partial load P/PN B31 Electrical data sheet document


5/4 4/4 3/4 2/4
B32 Order dimension drawing document
Efficiency η in % in acc. to IEC 60034-2-1
95.0 % 95.5 % 95.6 % 95.2 % Type test with heat run for horizontal motors, with acceptance
F83
Power factor cos φ K45 Anti-condensation heating, 230V
0.88 0.87 0.83 0.75
L00 Larger 1XB1 631 terminal box
Mechanical data:
Y54 Special paint finish in other colours:
Moment of inertia Jmot
3.6 kg*m²
Rotor winding material
Al
Bearing DE deep-groove ball
6218 C3
bearing
Bearing NDE deep-groove ball
6218 C3
bearing
Direction of rotation
Both
Relubrication interval/quantity DE | NDE
6000 h / 40 g

Environmental conditions:
Coolant temperature KT
40 °C
Installation altitude
1000 m
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Generated: 11.10.2023 19:22:09