You are on page 1of 32

Lux level Standards in Industry - Perfect Pollucon Services

Welcome To Perfect Pollucon Services


      
Ofce Hours: 10:00am-7:00pm

 Call Us
9967436537  Mail Us
ppshane@gmail.com  Maharashtra, India
3 Krishna Koyna B, Majiwada, Thane W

 Contact Us Now !!REQUEST A QUOTE

First name Last name


Ambient Air Quality Monitoring & Tesing
Email
Indoor Air Quality Monitoring & Tesing
Air Quality Monitoring & Tesing
Stack Emission Monitoring & Stack Emission Tesing
Company Name
Noise Level Monitoring & Tesing
Mobile Number (No Spam. Promise !)
Fugitive Emission Monitoring & Tesing
Perfect Pollucon Services
Soil Tesing & Invesigation Laboratory

Lux level Standards in Indusry


Drinking Water Tesing & Analysis Laboratory Promotional Code (Optional)
Illumination Survey
Lux level Standards in Indusry are
recommendations from IS for sufcient light at
Environmental Impact Assessment
workplace to maintain wellbeing, safety of workers
Environmental Statement
and productive work environment.
MPCB Consent To Esablish, Operate And Renewal
Considering
Operation increasing
And Maintenance Ofindusrial activities
Efuent Treatment Plantin
India,Treatment
Efuent where many people
Plant Design have to work with
attention
Water to details throughout day and night. With
Cess Returns

all diferent
Ventilation visual task’s conditions, lighting
Survey

should be suitable for adequate visibility in any


Get a Quote Now !
wpforms-submit
indusrial processes.
Pharmaceutical Indusries
Chemical Indusries 
Physical hazards can be prevented if sufcient
C s ti / R l Es t I d s

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Search
lighting is available in workplace area. Lighting
condition not only contributes to the safety but also
Search 
make workplace more comforting and productive.

Unit of illumination Download Our Brochure (682 kb)

The sandard unit to measure the intensity level of


Our Work And Clients
light is known as LUX. It is also called as
Tesimonials & Leave Us A Review
Illuminance or illumination.
Careers
Our Features
Locally Recognized Recent Poss
Afordable Pricing
Priority Service Lux level Standards in
Indusry

07,September,2022

Environmental Tesing
Laboratory
Quantity of Illumination in
11,July,2022

indusry
Fugitive Emission Tes
Ideally a lighting sysem should be designed in Procedure
such way that it provides uniform disribution of
09,July,2022
light over entire workplace.

And adequacy of lighting is necessary to avoid


Functions of
occupational eye-srain and accidents due to poor
Environmental
lighting. Adequate lighting also creates aggregable
Laboratories
illuminous work environment.
18,April,2021
Read more about
Efect of Poor lighting at workplace
How to Measure
Depending on the type of activity demand of Indoor Air Quality?

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

degree of illumination difers. For e.g.


20,March,2021

If you are reading, drawing then it is better to


maintain LUX levels around 200 Indoor Air Quality and
Health
To maintain sandard LUX level for ofce,
where people work on computers, laptops it is 31,May,2020

better to increase illumination to 400-500 LUX


CPCB Guidelines for
In Shops, showrooms lex levels should be
Stack Monitoring
maintained at 500 LUX
27,December,2019
At Workshops lux level should be maintained at
600-700 LUX
Professional Air
And for critical works like operation theatre in Quality Tesing
hospitals it is required to maintain LUX levels at
08,December,2019
1000

How to Start a Water


Quality of Illumination in Tesing Laboratory?

indusry 05,May,2019

Here Quality of illumination indusry is referring Efects of Poor


to disribution of brightness in workplace area. It Lighting at Workplace
expects uniform brightness throughout the
14,April,2019
indusrial area. Reduction in glares play major role
in maintaining quality of illumination. Refected
glares can be minimized of eliminated using light
source of low luminance or increasing the angle
from line of vision. There should not be any harsh
shadows in indusry.

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Illumination Standards as
per Factory Act, 1948
(Section 17 – Lighting)
As per factory act, 1948 section 17 there are few
rules and regulations to be followed by all
indusries in India. Few important points from
factory act for lighting are mentioned below:

All part of the factory where employees are


working or passing should have sufcient
lighting either by natural or artifcial source
In every factory all glazed windows and
skylights used for the lighting of the workroom
shall be kept clean on both the sides and so far
as agreement with the requirements of any rules
made under sub-section (3) of section 13 will
allow, free from obsruction.
In all factories, there should not be any glares
from directly any light source or indirectly
polished surface

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

In all factories, there should not be any shadows


which limits the visibility of the employees
which can cause accidents or eye srain
The State Government may prescribe sandards
of adequate and appropriate illumination for
factories or for any class or account of
workshops or for any indusrial process.

LUX Level in Indusry as


per Indian Standard (IS
6665)
Keeping this in mind Indian Burau of Indian
Standards had come up with sandards to be
followed for Indusrial lighting in IS:3646 (I –
1966), IS:3646 (II – 1966), IS:3646 (III – 1968).

They have updated those Illumination lux level


sandards for diferent indusries in 1972 as
IS:6665. Please fnd below recommended
Illumination lux level sandards for indusrial
buildings and processes.

Workplace LUX Level Standards in


Indusry

Read more about


Illumination Survey or Lighting assessment

Lux Level sandards for General factory areas:

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Average Limiting
Illumination LUX Glare
Level Standards Index

Canteens 150 –

Cloakrooms 100 –

Entrances, 100 –
corridors,
sairs

Lux Level sandards for Factory outdoor Areas

Average Limiting
Illumination Glare
LUX Level Index
Standards

Stockyards, 20 –
main entrances,
exit roads, car
parking, internal
factory roads

Aircraft factory

Average Limiting
Illumination Glare
LUX Level Index

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Standards

Stock parts 450 25


production

Drilling, riveting, 300 25


screw fasening,
wing sections,
welding, assembly,
sub-assembly,
inspection area

Maintenance and 300 25


repair (hangers)

Illumination levels at Assembly shops

Average Limiting
Illumination Glare
LUX Level Index
Standards

Rough work like 150 28


frame assembly.

Medium work like 300 25


machine parts,
engine assembly,
vehicle body
assembly.

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Fine work like radio 700 22


and telephone
assembly.

Very fne work like 1500* 19


assembly of very
small insruments

Boiler houses

Average Limiting
Illumination LUX Glare
Level Standards Index

Coal and 100 –


Ash handling

Boiler front 100 –


and
operating
areas

Others area 20 to 25 –

Catwalks 20 –

Platforms 50 –

Boot and Shoes Manufacturing factories

Average Limiting

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Illumination Glare
LUX Level Index
Standards

Sorting and 1000* 19


grading

Clicking and 700 22


closing,
preparatory
operations

Bottom sock 700 22


preparation,
lasing and
bottoming

Cutting table and 1000 22


presses, sitching

Shoe rooms 700 22

Brewers and Disillers

Average Limiting
Illumination Glare
LUX Level Index
Standards

General 150 25
working areas

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Brewhouse, 200 25
bottling and
canning plants

Bottle Special lighting –


inspection

Canning and preserving Factories

Average Limiting
Illumination Glare
LUX Level Index
Standards

Inspection of 450 22
beans, rice, barley,
etc

Preparation: Kettle 300 25


areas, mechanical
cleaning, dicing,
trimming

Canned and bottled 200 25


goods: Retorts

High speed 300 25


labelling lines

Can inspection 450 –

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Lux Level sandards for Carpet Factory

Average Limiting
Illumination Glare
LUX Level Index
Standards

Winding, 200 25
beaming

Designing, 450 22
jacquard card
cutting, setting
pattern,
tufting, topping,
cutting,
hemming,
fringing

Weaving, 450 22
mending,
inspection

Lux Level sandards for Chemical


manufacturing Factories:

Average Limiting
Illumination Glare
LUX Level Index

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Standards

Hand furnaces, 150 28


boiling tanks,
sationery driers,
sationery or gravity
crysallizers,
mechanical driers,
evaporators,
fltration plants,
mechanical
crysallizing
bleaching,
extractors,
percolators,
nitrators, electrolytic
cells

Controls, gauged, 100 –


values; etc

Lux level Standards in Indusry : Clothing


Manufacturing Factories

Average Limiting
Illumination LUX Glare
Level Standards Index

Cutting, 300-700 22-20

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

sewing

Inspection 450-100 19

Hand 450-1500 19
Tailoring

Lux Level sandards for Electricity Generating


Station

Average Limiting
Illumination Glare
LUX Level Index
Standards

Turbine halls 200 25

Auxiliary 100 –
equipment;
battery rooms,
blowers,
auxiliary
generators,
switchgear and
transformer
chambers

Boiler houses 70-100 –


(including
operating foors)

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

platforms,
coal conveyors,
pulverisers,
feeders,
precipitators,
soot and slag
blowers

Boiler house and 100 –


turbine house

Basements 70 –

Conveyor houses, 70-100 –


conveyor genets,
junction
towers

Control rooms 200-300 19

Nuclear reactors 150-200 25


and seam raising
plants

Electricity Generating Stations: Outdoor


Locations

Average Limiting
Illumination Glare
LUX Level Index

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Standards

Coal 20 –
unloading
areas

Coal sorage 20 –
areas

Conveyors 50 –

Fuel oil 50 –
delivery
headers

Oil sorage 50 –
tanks

Catwalks 50 –

Platforms, 50 –
boiler and
turbine decks

Transformers 100 –
and outdoor
switchgear

Lux level Standards in Indusry: Engineering

Average LUX Limiting Glare


Level Index

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Hand 1000 19

Machine – –

Foam Building

Average Limiting
Illumination LUX Glare
Level Standards Index

Boiler 50 –
houses

Milk room 150 25

Washing and 150 25


serilizing
rooms

Stables 50 –

Milking 150 25
parlours

Flour Mills

Average Limiting
Illumination Glare
LUX Level Index
Standards

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Roller, purifer, 150 25


silks and
packing foors

Wetting tables 300 25

Lux Level sandards for Foundries

Average Limiting
Illumination Glare
LUX Level Index
Standards

Charging foors; 150 28


tumbling
cleaning,
pouring, shaking
out, rough
molding and
rough core
making

Fine moulding 300 25


and core making,
inspection

Lux Level sandards for Garages

Average Limiting
Illumination Glare

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

LUX Level Index


Standards

Parking areas 70 28
(interior)

Washing and 150 28


polishing,
greasing, general
servicing,
pits

Repairs 300 25

Gas Work

Average Limiting
Illumination Glare
LUX Level Index
Standards

Retort houses, oil 30 to 50 28


gas plants, Water
gas plants, coke
handling plant

Governor, meter, 100 25


booser

Open type plants

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Average Limiting
Illumination LUX Glare
Level Standards Index

Catwalks 20 –

Platforms 50 –

Gauge and 700 19


Tool
Rooms

Glass Works and Processes

Average Limiting
Illumination Glare
LUX Level Index
Standards

Furnace rooms, 100 28


bending,
annealing

Mixing rooms, 150 28


forming
(blowing,
drawing,
pressing,
rolling)

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Cutting to size, 200 25


grinding,
polishing,
toughening

Finishing 300 22
(bevelling,
decorating,
etching,
silvering)

Brilliant cutting 700 19

Inspection 200 and 700 19


(General and
fne)

Inspection shops (Engineering)

Average Limiting
Illumination Glare
LUX Level Index
Standards

Rough work, for 150 28


example, counting,
rough

Medium work, for 300 25


example, ‘Go’ and

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

‘No-go’
gauges, sub-
assemble

Fine work, for 700 22


example, radio and
telecommunication
equipment,
calibrated scales,
precision
mechanisms,
insruments

Very fne work, for 1500 19


example, gauging
and inspection-
of small intricate
parts

Minute work, for 3000 10


example, very small
insruments

Lux Level sandards for Iron and seelworks

Average Limiting
Illumination Glare
LUX Level Index
Standards

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Mars-balling and 10-20 –


outdoor
sockyards

Stain, gangways, 100 –


basements,
quarries, loading
docks

Slab yards, 100 28


melting shops!
ingot sripping
soaking
pits, blas furnace
working areas,
picking and
cleaning lines,
mechanical
plants, pump
houses

Mould 150 28
preparation;
rolling and wire
mills, mill
motor rooms,
power and
blower houses

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Slab inspection 200 28


and conditioning,
cold srip mills,
sheet and plate
fnishing, tinning,
galvanizing,
machine and roll
shops

Plate inspection 300 –

Tinplate Special lighting


inspection

Motor Vehicle Plants

Average Limiting
Illumination Glare
LUX Level Index
Standards

General sub- 300 25


assemblies,
chassis assembly,
car assembly

Final inspection 450 25

Trim shops, body 300 25


sub-assembly,

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

body assembly

Spray booths 450 –

Rubber Processing

Average Limiting
Illumination Glare
LUX Level Index
Standards

Fabric 200 25
preparation
creels

Dipping, 150 25
moulding,
compounding
calendars

Tyre and tube 200 25


making

Sheet Metal Works

Average Limiting
Illumination Glare
LUX Level Index
Standards

Benchwork, 200 25

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

scribing, pressing,
punching, shearing,
samping, spinning,
folding

Sheet inspection Special –


lighting

Warehouses and Bulk Stores

Average Limiting
Illumination LUX Glare
Level Standards Index

Large 100 28
material,
loading
bays

Small 150 25
material,
racks

Packing and 150 25


dispatch

Lux Level sandards for Welding and Soldering

Average Limiting
Illumination Glare

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

LUX Level Index


Standards

Gas and arc 150 28


welding, rough spot
welding

Medium soldering, 300 25


brazing, and spot
welding, for
example, domesic
hardware

Fine soldering and 700 22


spot welding, for
example,
insruments, radio
set assembly

Very fne soldering 150 19


and spot welding,
for example, radio
valves

Woodworking Shops

Average Limiting
Illumination Glare
LUX Level Index
Standards

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Rough sawing, 150 22


and bench work

Sizing, planning, 200 22


rough sanding,
medium machine
and bench work,
gluing,
veneering,
cooperage

Fine bench and 300 22


machine work,
fne sanding and
fnishing

Perfect Pollucon Services ofers Illumination


Survey or LUX Level monitoring / tesing and
provide LUX Monitoring report for our clients.
Feel free to contact our Environmental executive
for more information.

What are recommended lux levels for an ofce?


In general, Ofces are required to have LUX level
at 500. In case of screen based devices such as
Computers / laptops LUX levels can vary from
300-500.

What is the minimum illumination or Lux level


is required in workplace i.e. working area?
The minimum level of illumination recommended

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

for work in general ofces is 200 lux. it is assumed


that tasks like reading in general ofces. in case of
any detailed work is done then minimum
illumination level needs to be around 500 LUX.

What is Standard lux level for residential?


At homes recommended illumination levels is
often 150 lux. The living and dining rooms may
work pretty well with about 25 to 50 lux. If you are
doing tasks like reading then Lux level needs to be
around 200.

What is the recommended lux level for a


warehouse?
For warehouses, it is recommended to have LUX
level around 150 at foor level and 200 LUX at
rack level.

What are the Lux level sandards for visual


inspection?
For normal activities in any ofce should be 200
Lux, but for the work which requires scrutiny and
detailing i.e. visual inspection lux level should be
at leas 500. Along with Lux level periodic res is
also required to the person who is performing
inspection to avoid fatigue.

What are minimum lux level for consruction


sites?
At consruction site where only movement of
people, machinery and raw materials are involved
then lux level 50 is more than sufcient. In case of
any detailed work is being done then it is
recommended to maintain lux levels minimum at

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

200 Lux at consruction site at all the time.

What is lux level calculation?


The LUX level in a room is calculated from the
following formula
E(LUX) = F(lm) x UF x MF / A
Where
lm is required lumens
E is the the LUX level achieved
UF is utilization factor
MF Maintenance factor
F is the average lumens value form the light source

Which activity requires the highes level of


illumination?
Activities which involve detailed work, demand
the highes level of illumination. Those activities
can be operation theatre in hospitals, color
inspection on paper or fabric, Autopsy table and
dissecting table, etc.

What are sandard lux level for bedrooms?


It is recommended that generally bedroom needs to
have lux levels between 100 to 300 Lux. Incase of
any activities like reading or painting LUX level
should be more than 500 Lux.

Source1

Source2

Source3

Source4

Source5

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Source6

Read More from Related


poss:

Environmental Monitoring Indoor Air Quality:The


Methods Ultimate Guide

Sound Level Measuring EHS Environmental Health


using smartphones? Think and Safety Roles &
twice Responsibilities

Lighting Assessment: The VOC Monitoring & Tesing:


Ultimate Guide Benefts of Sampling &
Analysis

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Sewage Treatment Plant How to Get MPCB


Process STP Consent?

Professional Air Quality Classifcation of Indusries


Tesing for Consent Management

How to Measure Indoor Air Mold Tesing for Homes


Quality?

Environmental
 Tesing
Laboratory

ENVIRONMENTAL ENVIRONMENTAL ABOUT US REGISTERED OFFICE


CONSULTANCY MONITORING
Home Perfect Pollucon
SERVICES SERVICES
Blog
Services –
Environmental Ambient Air Quality About Us
Environmental
Monitoring and Monitoring & Tesing Indusries We Serve
Consultancy

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]
Lux level Standards in Industry - Perfect Pollucon Services

Assessment Indoor Air Quality Save our Contact By


Environmental Monitoring & Tesing Scanning below Image Company
Impact Assessment Air Quality Monitoring &
Efuent Treatment Tesing 3 Krishna Koyna B,
Plant Fugitive Emission Majiwada Thane,
Efuent Treatment Monitoring & Tesing Maharashtra, India
Plant Design Stack Emission
400601
Consent to Monitoring & Stack
Esablish, Consent Emission Tesing
Email:
to Operate and Noise Level Monitoring
Renewal & Tesing ppshane@gmail.com
Ventilation Survey Air Quality Tesing at
Ofce Phone :
Tools
HTML Sitemap Corrosion Control at +91-9967-436-537
Data Center In IT
Indusry +91-9930-180-059

HOME ABOUT US CAREERS ENVIRONMENTAL BLOG CONTACT US

     

@Copyright Perfect Pollucon Services

https://www.ppsthane.com/blog/lux-level-standards-industry[16/01/2023 15:45:15]

You might also like