ID Label Start Node Set Invert to Start? Invert (Start) Stop Node
(m)
168 TUB-01 BZ-01 False 26.15 BZ-02
170 TUB-02 BZ-02 False 25.03 BZ-03
172 TUB-03 BZ-03 False 24.69 BZ-04
174 TUB-04 BZ-04 False 24.34 BZ-05
176 TUB-05 BZ-05 False 24.00 BZ-06
178 TUB-06 BZ-06 False 23.67 O-1
Set Invert to Stop? Invert (Stop) Has User Defined Length (User Length (Scaled) Slope (Calculated)
(m) Length? Defined) (m) (%)
(m)
False 25.03 False 71.9 1.554
False 24.69 False 47.2 0.726
False 24.34 False 47.3 0.726
False 24.00 False 66.0 0.526
False 23.67 False 65.9 0.500
False 23.55 False 22.8 0.500
Section Type Diameter Manning's n Flow Velocity Depth (Middle)
(mm) (L/s) (m/s) (m)
Circle 250.0 0.013 1.50 0.60 0.04
Circle 250.0 0.013 3.66 0.60 0.05
Circle 250.0 0.013 3.66 0.60 0.05
Circle 250.0 0.013 5.39 0.60 0.08
Circle 250.0 0.013 12.16 0.74 0.10
Circle 250.0 0.013 16.48 0.81 0.11
Capacity (Full Flow) Flow / Capacity Depth/Rise Tractive Stress Material Notes
(L/s) (Design) (%) (Calculated)
(%) (Pascals)
74.12 2.2 15.5 2.384 PVC
50.68 7.9 18.9 1.970 PVC
50.68 7.9 21.4 1.970 PVC
43.11 13.7 30.3 1.812 PVC
42.05 31.7 40.1 2.464 PVC
42.05 43.0 42.2 2.786 PVC