Model 28102SEXTENDED
JIB 46 FT
FIXED AND
RETRACTED
JIB 26 FT
102 FT
85 FT
68 FT
BOOM LENGTH IN FEET
81 FT
RANGE DIAGRAM
- FULLY EXTENDED OUTRIGGER CONFIGURATION -
75
I
i &
ie
Il .
I a
I co
CI D
|
II
/ c DO NOT
| %.
se
‘7300093-002 NR
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100105
OPERATING RADIUS FROM CENTERLINE OF ROTATION IN FEET
HEIGHT ABOVE GROUND IN FEETTHE FRONT TIRES MUST
BE IN CONTACT WITH
THE GROUND, AND THE
MACHINE LEVEL, WHEN.
OPERATING IN_THIS AREA.
ALLOWABLE LINE PULL WARNING
T PART | 2 PART | 3 PART | 4 PART | 5 PART | 6 PART
UNE | “LINE LINE LINE LINE LINE
ANTI-TWO-8LOCK
° (°) HE g | SYSTEM MUST BE
5g $8] CONDITION BEFORE
y ze 28] OPERATING CRANE.
3
3 & fe y | REFER TO THE
2 3 3 | oWNER’S MANUAL.
za 5 38 a a
2 g 28 ay uy
88 ° i Ps 28| Keep AT LEAST 3
/ oy FS 5®| WRAPS OF LOAD
LINE. ON THE ORUM
‘AT ALL TIMES.
soo | 17000 | 25500 42500 | 51000 56000 | (550/16) MEIC
LBS LBS LBs Ups iss LBS MIN BREAKING STRENGTH|
7490 | 14800 | 22200 37000 | 44400 51800 | SP rT Sor ns
LBS LBs Les tes Lgs LBS MIN BREAKING STRENGTH
AREA OF oo}!
OPERATION STANDARD 360" FULL
CAPACITY WORK AREA
WARNING:
AUXILIARY BLOCK — —- — — — — — — — — — — soles
AUXILIARY SHEAVE — —- — — — — — — — — — — 50 Lbs
OVERHAUL BALL—— ——- —- —— SEE OVERHAUL BALL MANUFACTURER NAMEPLATE
7300093-002 NR
LOAD BLOCK
HOSE
SWING AROUND JIB
— — — — — — — SEE BLOCK MANUFACTURER NAMEPLATE
140 LBS
— — — — — — SEE LOAD CHARTTHIS. OUTRIGGER
[CONFIGURATION
ALL OUTRIGGER,
Beams FULLY
RETRACTED
USE THIS CHART
ONLY WHEN ALL
OUTRIGGERS ARE
FULLY RETRACTED
87.38 REF
(7" 3-3/8" REF)
- FULLY RETRACTED OUTRIGGER CONFIGURATION -
WAIN BOOM LOAD RATINGS IN LES
a coe FS
SASS,
eal LOPES
pr oes
hi s7ee
My A NowIBS ARE TO
_ ie 51 FT| 4 | 68 FT 85 FT| 4/102 FT BE ERECTED IN
THs
OUTRIGGER
To] 71}14590) 78 CONFIGURATION
[2] 67] 10180] 77 [10700 I
15 [60] 6420/73] 6970/70
20] 48 3330[67| 3790] 74] 3050] 76] OsO[ ST] 7000
25 [33] 1620[ 61] 2090] 70] 2250|75| 2330] 78] 2580
30 S4[ 1040|65| 1190] 72| 1270] 76] 1320)
720185 | 250 18S | 220 18S | 180 155 [150 18S [DEDUCTIONS FOR STOWED FRED JB
730 18s | 440 Las | 330 18S | 260 Les | 220 LBS [DEDUCTIONS FOR STOWED TELESCOPIC Jl
7300099-002 NRRANGE DIAGRAM
- FULLY RETRACTED OUTRIGGER CONFIGURATION -
120
102 FT Bole "
110
105
100
86 FT
68 FT
Do NoT 65
POSITION ,
A BOOM 60
INTO THIS 55
‘AREA
51 FT
=
BOOM LENGTH IN FEET
30.5 FT
HEIGHT ABOVE GROUND IN FEET
0 § 10 15 20 25 30 35 40 45 50 55 60 65
OPERATING RADIUS FROM CENTERLINE OF ROTATION IN FEET
NOTE : LIFTING PERSONNEL WITH CRANE IN THIS OUTRIGGER
CONFIGURATION IS STRICTLY PROHIBITED. USE ONLY
FULLY EXTENDED OUTRIGGER CONFIGURATION WHEN
‘7300093-002 NR LIFTING PERSONNEL.PINS MUST BE
ENGAGED FOR THIS
OUTRGGER
CONFIGURATION.
ALL ouTRIGER
Beams MUST BE
EXTENDED To MiD
EXTEND MARK.
USE THIS CHART ONLY WHEN
ALL OUTRIGGERS ARE IN THE
INTERMEDIATE POSITION
WARK
INDICATES
BEAM IS MD
EXTENDED 161.69 REF
—~(13' 5-11/16" REF)
- INTERMEDIATE OUTRIGGER CONFIGURATION -
(MID EXTEND)
TB reo we [TELESCOPE 8
CS/ES Li CODE #10 | Uw cove #11] LMI CODE #12
TAA
EAT So) 2g], glue uencm), glue venom], 8 |v vencr|
RT S PAIL |For au |S 8| "ror a |S O| "FoR AL.
HL ees 5/2 g) fara (23) “acc |g) "ae
ts A RUIGM) uencms [5] uencris [3M] Lencrs
8 IPA wale [5 4] wine [8 A] wan
st St FT 68 FT 5 FT]eo2 Filwe) ¢| nowe* | 6] noree | 6] Nore +
8 Z| 26 FT| A| 26 FT 46 FT
10| 71] 33510] 79 [22500
3267 [29120] 77 22500
5 27| 1980/60] 2160|60| 2260/66| 2310] 45|72| 2390 |72| 2080 | 76] 2590
50, 43[ 1520[56| 1620/63] 1670[ 50 |70| 1750 [70] 1440 [74[ 1930
55 36{ 1070/51] 1110/60] 117055 [6a] 1240 [eel 930 [72[ 1410
60 28| 600/47 700/56| 750/60 [65/820 [es| 510 [70] 990
65 65 68| 640
490 LBS [ 290 LBS | 220 LBS | 780 LBS | 150 LBS [DEDUCTIONS FOR STOWED FIXED JIB
730 LBs | 440 Ls [ 330 LBs | 260 LBs | 220 LBS [DEDUCTIONS FOR STOWED TELESCOPIC JiBl
7300093-002 NRRANGE DIAGRAM
- INTERMEDIATE OUTRIGGER CONFIGURATION -
(MID EXTEND)
20
EXTENDED
JIB 46 FT ft *s
70"
ip .
FXED AND i
RETRACTED |
‘ie 26 FT i
b
i
ui
@
z So:
x i So.
z oasr
9 We
Fe 50 _poNoT
a POSITION
= Boom OR
S wer i “IB INTO
B 4TH
a AREA
If “
oe
I] 3s
| se
30.5 FT L 25°
20
1s
1
7300093-002 NR
0 5 10 15 20 25 30 36 40 45 50 55 60 65 70 75 80 85 90
165
160
195
150
145
140
135
130
125
120
115
110
105
100
95
80
85
80
ay
70
65
60
55
50
45
40
35
30
25
20
15
10
OPERATING RADIUS FROM CENTERLINE OF ROTATION IN FEET
NOTE
LIFTING PERSONNEL WITH CRANE IN THIS OUTRIGGER
CONFIGURATION IS STRICTLY PROHIBITED. USE ONLY
FULLY EXTENDED OUTRIGGER CONFIGURATION WHEN
LIFTING PERSONNEL.
HEIGHT ABOVE GROUND IN FEETPINS MUST BE
ENGAGED FoR ‘ALL OUTRIGGER BEAMS
CONFGURATION e YO Putt BAtEND wae
a
USE THIS CHART ONLY —1 ie co —
WHEN ALL OUTRIGGERS =
ARE FULLY EXTENDED THIS WARK
INOWcATES
Beaw is ruwy
EXTENDED
| 236.00 REF
(19° 8” REF)
+ FULLY EXTENDED OUTRIGGER CONFIGURATION -
WAIN BOOM LOAD RATINGS IN LAS IB LOAD RATINGS IN LAS
MI CODE # FIXED JIB LESCOPIC_ JIB
nt coor #2 | um cove #3 | Um CODE Fe
88
Bs
il arly 3Peane"h, Beane, 8) nasi
rs £8199] "Sou |$9| “eon [9 8) "Saou
Ae Ri OM) uenctHs |p M) LENGTHS [9 M] LENGTHS:
a #515 4) with |B 4) wie [F 8] wie
Sos Alsi |Z [6e |Z [as er|Z for 7), |) see |? 8] weer |P 8] eae
5 | 80|56000) er
8 | 75| 39690] A| 26 FT | Z| 26 FT| | 46 FT
io 71]33510] 79172500 5
12 [67|28120)77 [72500 2
15 [6025260] 73] 21710] 76] 20590 5
20] «8| 6530/67 | 16910} 74] 15630] 78] 14470] 81 [705001 70
251 35[ 12410) 6112670) 70[ 12640 75| 12160] 769650) 25 [Bi] 3300 [wr] S100
90 I 29| 880| 90|48| 990 |48| 690 [56] 1150
95 22[ 640 95 [45] 750 s4[_ 910
100] 100) S1{ 700
108| 105) 48,510
490 LBS | 290 LBS | 220 LBS | 180 LAS | 150 LBS |DEDUCTIONS FOR STOWED FIXED JIB
730 LBS | 440 L8S | 330 LBS | 260 LBS | 220 LBS [DEDUCTIONS FOR STOWED TELESCOPIC JIB)
7300099-002 NRLMI OPERATING CODES
SETTING CRANE CONFIGURATION OUTRIGGER CONFIGURATION
#1——MAIN Boom —————— ---------- — FULLY EXTENDED
#2 - Fixed vig. ———————-—---- —----= = FULLY EXTENDED
#3—— TELESCOPIC JIB-RETRACTED. ——————————-— — FULLY EXTENDED
#4— — TELESCOPIC JIB-EXTENDED -——————~— === FULLY EXTENDED
#5—— PERSONNEL LIFTING PLATFORM ON MAIN BOOM FULLY EXTENDED
#6—— PERSONNEL LIFTING PLATFORM ON FIXED JIB) — —————— — FULLY EXTENDED
#7—— PERSONNEL LIFTING PLATFORM ON TELESCOPIC JIB-RETRACTED —— FULLY EXTENDED
#8—— PERSONNEL LIFTING PLATFORM ON TELESCOPIC JIB-EXT FULLY EXTENDED
#2—— MAIN BOOM ——————————————————— INTERMEDIATE,
#10 — Fixed vig. ————————~—--— ——————= INTERMEDIATE
#11 — TELESCOPIC JIB-RETRACTED —————————-—-— —__ INTERMEDIATE
#12 — TELESCOPIC JIB-EXTENDED ~———————— ————=_ INTERMEDIATE
#13 — MAIN BOOM
FULLY RETRACTED
WARNING
1. THE OPERATOR MUST READ AND UNDERSTAND THE OWNER'S MANUAL BEFORE OPERATING
THIS CRANE,
2. POSITIONING OR OPERATION OF CRANE BEYOND AREAS SHOWN ON THIS CHART IS NOT
INTENDED OR APPROVED EXCEPT WHERE SPECIFIED IN OWNER'S MANUAL.
3. LOADED BOOM ANGLES AT SPECIFIED BOOM LENGTHS GIVE ONLY AN APPROXIMATION OF THE
OPERATING RADIUS. THE BOOM ANGLE SEFORE LOADING SHOULD BE GREATER TO ACCOUNT
FOR DEFLECTIONS. DO NOT EXCEED THE OPERATING RADIUS FOR RATED LOADS,
4, THE OPERATING RADIUS SHOWN IN THE JIB RATING CHART IS FOR FULLY EXTENDED BOOM
ONLY. WHEN. BOOM IS _NOT FULLY EXTENDED, USE ONLY LOADED BOOM ANGLE TO
DETERMINE LOAD RATING OF JIB.
5. FOR BOOM ANGLES NOT SHOWN ON JIB LOAD RATING CHART, USE RATING OF NEXT LOWER
BOOM ANGLE,
6. FOR BOOM LENGTHS NOT SHOWN, USE RATING OF NEXT SHORTER OR LONGER BOOM
LENGTH, WHICHEVER IS LESS. FOR RADII NOT SHOWN, USE RATING OF NEXT LONGER
7. CRANE LOAD RATINGS ON QUTRIGGERS ARE BASED ON FRE!
MACHINE. LEVEL
SHALL
LY SUSPENDED LOADS WITH THE
ED AND STANDING ON A FIRM UNIFORM SUPPORTING SURFACE. NO ATTEMPT
& MADE TO MOVE A LOAD HORIZONTALLY ON THE GROUND IN ANY DIRECTION,
7300093-002 NRWARNING (CONTINUED)
8. PRACTICAL WORKING LOADS DEPEND ON SUPPORTING SURFACE, WIND, AND OTHER FACTORS
AFFECTING STABILITY SUCH AS HAZARDOUS SURROUNDINGS, EXPERIENCE OF PERSONNEL,
AND PROPER HANDLING, ALL OF WHICH MUST BE TAKEN INTO ACCOUNT BY THE OPERATOR.
9, THE MAXIMUM LOAD WHICH MAY BE TELESCOPED IS LIMITED 8Y HYDRAULIC PRESSURE,
BOOM ANGLE, AND BOOM LUBRICATION. IT IS SAFE TO ATTEMPT TO TELESCOPE ANY LOAD
WITHIN THE LIMITS OF THE LOAD RATING CHART.
10. LIFTING OFF THE MAIN BOOM POINT WHILE THE SWING AROUND JIB IS ERECTED IS NOT
INTENDED OR APPROVED,
INFORMATION
1. DEDUCTIONS MUST BE MADE FROM RATED LOADS FOR STOWED JIB, OPTIONAL
ATTACHMENTS, HOOKS, AND LOADBLOCKS (SEE DEDUCTION CHART). WEIGHTS OF SLINGS
AND ALL OTHER LOAD HANDLING DEVICES SHALL BE CONSIDERED A PART OF THE LOAD,
2. LOAD RATINGS ABOVE THE HEAVY LINE ARE STRUCTURALLY LIMITED CAPACITIES. LOAD
RATINGS BELOW THE HEAVY LINE ARE STABILITY LIMITED CAPACITIES AND DO NOT EXCEED
85% OF TIPPING.
DEFINITIONS
1, OPERATING RADIUS IS THE HORIZONTAL DISTANCE FROM THE AXIS OF ROTATION TO THE
CENTER OF THE VERTICAL HOIST LINE OR TACKLE WITH LOAD APPLIED.
2. LOADED BOOM ANGLE AS SHOWN IN THE COLUMN HEADED BY , IS THE INCLUDED.
ANGLE BETWEEN THE HORIZONTAL AND LONGITUDINAL AXES OF THE BOOM BASE AFTER
LIFTING RATED LOAD AT RATED RADIUS.
7300093-002 NR