SpaceOAR™ System
Absorbable Perirectal Hydrogel Spacer
SO-1010
Introduction
SpaceOAR is a temporary implant. The implant is a soft, water-based gel (a hydrogel). It is meant to be used with
patients who will undergo prostate radiation therapy.
A trained doctor will use a needle to inject the implant between the prostate and the rectum to create space. The
space is intended to reduce the radiation delivered to the rectum, as well as bowel problems that can happen as a
result.
Your doctor will decide the best type of anesthesia to use. During your procedure, an ultrasound probe will be
placed in your rectum. The probe guides the needle placement and injection. After the injection, the needle and
probe will be removed.
Expected Lifetime of Implant
SpaceOAR maintains space for about 3 months. It is absorbed and passed naturally by the body in about 6 months.
What to Expect After the SpaceOAR Injection Procedure
After the procedure, you might feel some discomfort at the injection site. This should not last.
Check with your doctor about what to avoid after the procedure and during your radiation treatments.
Information on Safe Use
Listed below are some side effects that could happen with SpaceOAR. Ask your doctor for help to understand this
information, and to decide if this procedure is right for you.
BSC (MB Product Information for Patients Template 8.2677 x 11.6929 A4, 92340842I) ePIP, MB, SPACEOAR SYSTEM, EN, 51485445-01A
Indications For Use
SpaceOAR is intended to reduce the amount of radiation that is delivered to the rectum during radiotherapy for
prostate cancer. It does this by creating more space between the prostate and the rectum.
Contraindications
None known.
Precaution
• The implant contains Polyethylene Glycol (PEG). The use of this product in patients who are sensitive or allergic
to PEG has not been studied.
BSC (MB Product Information for Patients Template 8.2677 x 11.6929 A4, 92340842I) ePIP, MB, SPACEOAR SYSTEM, EN, 51485445-01A
Substituted Polyethylene Glycol (PEG) <10%
Phosphate Buffer Solutions
<4%
Amine Salt
Borate Buffer Solution <1%
MR MR Safe
BSC (MB Product Information for Patients Template 8.2677 x 11.6929 A4, 92340842I) ePIP, MB, SPACEOAR SYSTEM, EN, 51485445-01A
Australian
Sponsor Address
Boston Scientific (Australia) Pty Ltd
PO Box 332
BOTANY NSW 1455 Australia
Free Phone 1800 676 133
Free Fax 1800 836 666
bostonscientific.com
0344
© 2022 Boston Scientific Corporation or its affiliates.
All rights reserved.
2022-05
Your doctor’s Instructions for Use is 51455263-01A, issued 2022-01. < en >
51485445-01