You are on page 1of 2

18,579

8 7 6 5 4 3 2 1 825,579

NOTES: ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 77790 ORIGINAL RELEASE 2009MAY15 OWANESIAN B.WARREN


1. STARTER PANEL TO BE WIRED PER IR WIRING SCHEMATIC DRAWING 23382245. 825,561

2. PRINCIPAL COMPONENTS ARE L-S, ABB, OR BENSHAW.

3. PANEL TO BE BUILT IN ACCORDANCE TO UL508A AND MARKED ACCORDINGLY.

4. SUPPLY PRE-WIRED FOR E-STOP, CONTROLLER CONNECTIONS, AND EARTH STRAP


READY FOR MOUNTING TO ENCLOSURE.
24 36 43 3 54691076 SCREW, WHIZ LOCK D
D 5. MARK WITH IR PART NUMBER AND REVISION WHERE SHOWN 35
42 3 93469633 TERMINAL, EARTH M4/6.P
31
41 A/R 67747576 WIRE, MULTICONDUCTOR

1 2
40 1 54766928 THERMOSTAT, NORMALLY CLOSED

27 39 1 54729546 CONNECTOR, 2 WAY


38 2 54729520 CONNECTOR, 12 WAY
22
20 37 2 54729496 CONNECTOR, 8 WAY
30 36 2 54719182 CONNECTOR, 2 WAY
35 1 54719174 FILTER, RFI POWER LINE
18 26 34 2 54689872 BREAKER, CIRCUIT -
42
33 1 54689864 BREAKER, CIRCUIT
36 32 1 54689856 BREAKER, CIRCUIT
25
31 1 54641337 ASSEMBLY, PCB SGN - POWER SUPPLY
39 30 1 54612940 TERMINAL, END PLATE - ENTRELEC 118 368.16
40 16 29 6 54363429 TERMINAL, LOCKING FORK (WIRE RANGE 12-10 STUD SIZE #10)
23
C 37 28 1 39266200 RELAY, K1-2 N37 KW - 300 HP C
14
27 2 39252937 STOP, DIN RAIL N37-75
38
17 26 52 39252903 BLOCK, TERMINAL ba
25 1 39242375 PLUG, 10 POSITION
21 19 4
24 4 39239140 STANDOFF, HEX #4 X .375 LONG ALUMINUM
33
34 23 2 39191655 PLUG, 16 POSITION
15 28 22 1 39186101 PLUG, 4 POSITION
32
21 2 39186093 PLUG, 6 POSITION
12
3 20 1 32342115 BUS, ALUMINIUM GROUNDING ( 7 TAPS )

13 19 1 23668858 DIODE, TVS


34
18 1 23668833 CAPACITOR, PLASTIC FILM
10 17 1 23644743 RELAY, PLUG-IN, DPDT
29
16 1 23644701 RELAY, PLUG-IN, DPDT
11 8 15 2 23644685 SPRING, PULLOVER WIRE
14 2 23644677 SOCKET, DIN RAIL MOUNT
B 43 8 13 1 23580004 BLOCK, FUSE 30A, 600V, 3-POLE B
9
12 3 23541568 FUSE, 30A 600V BUSSMAN JJS-30
6
5 11 1 23505647 CONTACTOR, 22 AMPS
10 1 23467194 CONTACTOR, BLOWER MOTOR KM4, RSC-12-6AC110
9 A/R 23464530 RAIL, 35 MM DIN
7 8 4 23455520 SUPPRESSOR, SURGE
7 1 23436694 PANEL, BACK (VSD)
6 1 23434368 DRIVE, FAN VF (FC51M3) 4KW
5 1 22242390 TRANSFORMER, CONTROL 850VA MULTI-TAP 380-480V
4 1 22135818 BREAKER, CIRCUIT 6A - 1P
3 1 22135800 BREAKER, CIRCUIT 1A - 2P MCB3
2 A/R 22101224 COVER, WIRING DUCT, 1"

ATTACH CUSTOMER GROUND 1 A/R 22101208 DUCT, WIRING, 1" X 3"


CONNECTION DECAL HERE ITEM QTY. PART NO. DESCRIPTION MATL. SHT/Z

A
BOM FOR 23466584 A
DO NOT SCALE DRAWING
402,81 615,81 825,81

STANDARD TOLERANCES WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO
ALL DIMENSIONS ARE IN ASME Y14.5M - 1994
THIRD ANGLE PROJECTION
MILLIMETERS PROPRIETARY NOTICE DRAWN DATE
[INCHES (IF SHOWN)] THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, H.OWANESIAN 2009MAY15
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE
TITLE

UNSPECIFIED TOLERANCES: GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION


AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE UNLESS OTHERWISE SPECIFIED: B.WARREN 2009MAY15 ASSEMBLY, BACKPANEL
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
90-110kW AC VSD 380-575V 60 Hz
- REMOVE ALL BURRS AND SHARP CORNERS APPROVED DATE
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY - WELD SYMBOLS TO BE IN ACCORDANCE
WHOLE : ±1 THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION B.WARREN 2009MAY15
ONE PLACE (.X) : ± 0.5 WITH ANSI/AWS A2.4
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS SIZE ESTIMATED WEIGHT DWG NO. REV
TWO PLACE (.XX) : ± 0.25
A1 23466584 J
EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET (KG UNLESS OTHERWISE SPECIFIED)
ANGLES (.X) : ±1° INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO COPYRIGHT @ 2010
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL INGERSOLL-RAND COMPANY
18,18
Ingersoll-Rand Industrial Technologies 402,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. ALL RIGHTS RESERVED
SCALE:
0.25 UNIT:
90-110KW SHEET
1 OF 2

8 7 6 5 4 3 2 1
23-Jun-2010 09:54:06 (model J.0/J.1+)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED
18,579
18,579
8 7 6 5 4 3 2 1 826,579

ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

B 77894 22135818 BREAKER, CIRCUIT WAS 23063720. 2009AUG07 OWANESIAN B.WARREN


22315618 FUSE, 22315675 BLOCK WAS 54689898.
23505647 CONTACTOR WAS 23467194.
23467194 WAS QTY 1 WAS QTY 2.
23455520 SURPRESSOR QTY 4 WAS QTY 2.
ADDED 93469633 TERMINAL, EARTH.
32342115 ALUM. BUS WAS 22314926 GND BUS.
ADDED 54719182 CONNECTOR, 2 WAY.
ADDED 54729546 CONNECTOR, 2 WAY.
ADDED 54729488 CONNECTOR, 6 WAY.
ADDED 54729496 CONNECTOR, 8 WAY.
ADDED 54729512 CONNECTOR, 10 WAY.
D ADDED 54729520 CONNECTOR, 12 WAY. D
ADDED 54729538 CONNECTOR, 16 WAY.
ADDED 54729090 CONNECTOR, 4 WAY.
ADDED CUST GND DECAL NOTE TO BACKPANEL
C 77948 54766928 CONNECTOR, 2 WAY QTY WAS 2. 2009OCT02 OWANESIAN B.WARREN
54719182 CONNECTOR, 2 WAY QTY WAS 1.
D 78262 39186093 PLUG WAS 54729488 CONNECTOR. 2009NOV12 OWANESIAN B.WARREN
39191655 PLUG WAS 54729538 CONNECTOR.
39242375 PLUG WAS 54729512 CONNECTOR.
39186101 PLUG WAS 54729090 CONNECTOR.
E 78355 ADDED 96751722 SCREW, TAPPING M4 X 10 LG. 2010JAN08 OWANESIAN B.WARREN
23580004 BLOCK WAS 22315675 BLOCK.
F 78355 54691076 SCREW WAS 96751722 . 2010JAN13 OWANESIAN B.WARREN
G 78511 ADDED SHEET 2. 2010APR21 OWANESIAN B.WARREN
MOVED REVISION TABLE TO SHEET 2.
1,C3 ADDED 54363429 TERMINAL.
H 78511 ADDED SHEET 2.. 2010APR29 OWANESIAN B.WARREN
MOVED REVISIONS B, C, D, E, F, & G TO SHT 2.
39266200 RELAY WAS QTY 2.
ADDED 23644685 SOCKET.
ADDED 23644677 SPRING.
ADDED 23644701 RELAY.
ADDED 23644743 RELAY.
MOVED 23434368 DRIVE.
MOVED 22242390 TRANFORMER.
1,B3 J 78740 ADDED 23668858 DIODE. 2010JUN21 OWANESIAN B.WARREN
1,B3 ADDED 23668833 CAPACITOR.
1,D3 ADDED 67747576 WIRE,MULTICONDUCTOR.
1,B3 23541568 FUSE,30A WAS 22315618 FUSE,20A.
C C

B B

A A

636,54 825,54

PROPRIETARY NOTICE TITLE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET


INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND ASSEMBLY, BACKPANEL
90-110kW AC VSD 380-575V 60 Hz
IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY
RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE

23466584
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT SIZE DWG NO. REV
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN A1 J
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE: SHEET
18,18
18,18 636,18
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.25 2 OF 2

8 7 6 5 4 3 2 1
23-Jun-2010 09:54:06 (model J.0/J.1+)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED