You are on page 1of 3

20.10.23.

03:37 TL1451A Protection works when the device powers off - Power management forum - Power management - TI E2E support forums

This thread has been locked.


If you have a related question, please click the "Ask a related question" button in the top right corner. The newly
created question will be automatically linked to this question.

TL1451A Protection works when the device powers off


Intellectual 460 points
HM

My customer found protection works unexpectedly when the device power is turning on and off repeatedly for approximately
1s. While in protection mode, it is impossible to control at all, but return to normal work after power cycling.

After changing DTC capacitor value from 1uF to 0.1uF, the phenomenon has been disappeared. But, it may may not be a
corrective action.

https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/444367/tl1451a-protection-works-when-the-devi… 1/3
20.10.23. 03:37 TL1451A Protection works when the device powers off - Power management forum - Power management - TI E2E support forums

https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/444367/tl1451a-protection-works-when-the-devi… 2/3
20.10.23. 03:37 TL1451A Protection works when the device powers off - Power management forum - Power management - TI E2E support forums

(1) What's the cause to enter the protection mode?

(2) Is changing DTC capacitor value to 0.1uF a corrective action on this?

(3) Can you please let me know how to calculate the Dead-Time?

Best Regards,

Hide

over 8 years ago

JohnTucker over 8 years ago TI__Guru**** 191445 points


That part is over 30 years old. I doubt there is much supplemental information available for it. Also, it is not clear from
your partial schematic how the part is being used. Can you provide more details?

https://e2e.ti.com/support/power-management-group/power-management/f/power-management-forum/444367/tl1451a-protection-works-when-the-devi… 3/3